GE / ITI / UC Life Guard Basics

Mainly used as a Health Monitor although it can be Armed/Disarmed with a Keyfob, it does talk
Zones 17 Total, up to 17 wireless, 1 hardwire (Zone 18)
Wireless Yes
AC Transformer 9-volts screwed into outlet somewhere in house
Batteries
Panel 6 “AA” Alkaline or 6 Ni-Cad 1.2 volt Lithium
(Replace with same type, Lithium with Lithium, or it WILL be messy!)
Door/Window 3.6-volt Lithium
Motions 3.6-volt Lithium
Smoke Detector 2 9-volt Alkaline
Panic Buttons Police and Fire, Press each pair twice or hold down large Medical Panic
Downloadable Yes, customer MUST be home
Arm command isn’t really Arming but telling panel your gone, its more Health Monitor than Alarm
Arm Away Press ACTIVITY LEVEL Button until AWAY light turns ON and says “Goodbye”
Or press LOCK Button on Keyfob until AWAY light turns ON
Arm Stay Press ACTIVITY LEVEL Button until DAY light turns ON and system says “Hello”
or press LOCK Button on Keyfob until DAY light turns ON
Arm Night Press ACTIVITY LEVEL Button until NIGHT Light turns ON and says “Hello”
Or Press LOCK Button on Keyfob until NIGHT Light turns ON
Status Press STATUS, panel will beep and speak current status
Monitor System can remind customer to take medication
panel will beep once every 2 seconds or if CANCEL Buttons
are pressed when this pre-programmed time elapses
No-Activity If no motion is sensed for a programmed time system will beep and
flash DAY and NIGHT Lights, press any key to reset
Sensor Test Press TEST Button once, there will be 15 minutes to activates all sensors
Press both CANCEL Buttons to end Sensor Test
(Wireless motions require no movement for 4 minutes prior to testing)
Phone Test Press and hold TEST Button for 3 seconds, system will say “Phone test is ON”
(System says “Phone Test is OK” or “Phone Test Failure”)
Alarm Memory Press STATUS and TEST Buttons at same time for 3 seconds
Clear Memory 1. Press TEST Button, system will say “Sensor Test is ON”,
2. Press both CANCEL keys, system will say “Sensor Test is OFF”
3. Alarm Memory is now Empty
Volume hold both CANCEL Buttons until desired volume found