Program Sheet |
(Usually no programming below is needed) |
|
* + # + 10 + 1234 + # |
Enters Interrogator Programming |
|
* + # + 11 + # + 0 or 1 |
Turn Aux Output OFF (0) or ON (1) |
|
* + # + 30 + ???? + # |
Set Interrogator Login Password |
|
* + # + 31 + 0 or 1 + # |
Set Dialing format for Pulse (0) or DTMF (1) |
|
* + # + 32 + ??? + # |
Phone Number (up to 20 digits, for pause hold 7 for 5 seconds) |
|
* + # + 33 + 0 or 1 + # |
Off site Accessing OFF (0) or ON (1) |
|
* + # + 34 + 0 to 7 + # |
Sets Unit ID number (Caretaker Plus and SX-V only) |
|
* + # + 35 + ?? + X + # |
Determine which sensor activates which microphone
?? |
= Sensor Number (01 to 63) |
X |
= Which microphone (1 to 3) for microphone 1 to 3) |
|
|
* + # + 36 + ?? + # |
Delete sensor mapping done by above command
?? = Sensor Number (01 to 63)
|
|
* + # + 38 + ???? + # |
Interrogator 5-digit Account Number (never used) |
|
* + # + 39 + ? + # |
Set Control panel type (1 to 2) connected to Interrogator
1 = Caretaker Plus (these settings not applicable to SX-V)
2 = Commander 2000
|
|
* + # + 40 + X + Y + # |
Trip Input and Trip Action
X |
= Trip Input |
Y |
= Trip Action |
0 |
= Falling edge |
0 |
= Instant ON, Activation Beeps |
1 |
= Rising edge (SX-V) |
1 |
= Instant ON, no Activation Beeps |
2 |
= ITI Trip |
2 |
= Callback, answer on 1st ring |
|
(Caretaker +, Com 2000) |
3 |
= Dial out after trip detect |
4 |
= Callback, No On-site phone ring |
|
|
* + # + 41 + > + # |
Interrogator Aux output option Disabled (0) or Enabled (1) |
|
* + # + 42 + X + Y + # |
Auxiliary Output Time/Recording Save Time |
V1.5 |
* + # + 42 + X + Y + + Z + # |
Auxiliary Output Time/Recording Save Time/CS Hold Time
X |
= Aux Output Time |
Y |
= Recording Save Time |
0 |
= 5 seconds |
0 |
= 10 minutes) |
1 |
= 10 seconds |
1 |
= 20 minutes |
2 |
= 5 minutes |
2 |
= 1 hour |
3 |
= 10 minutes |
3 |
= 5 hours |
Z |
= Central Station Hold Time (v1.5 and higher only) |
0 |
= 1 minute |
1 |
= 2 minutes |
2 |
= 3 minutes |
3 |
= 4 minutes |
|
|
* + # + 43 + ??? + # |
Sets House Code (001 to 255, must match Control panel) |
|
* + # + 44 + ? + # |
Switches hot-key assignments (0 or 1 default is 0)
Default |
is 0 = 0 Listen 4 Talk 7 Extend 9 Terminate |
Switched |
is 1 = 1 Talk 3 Listen 7 Extend 9 Terminate |
|
|
* + # + 49 + # |
Clears Memory, defaults Interrogator |
Press 99 to exit Important! Move vertical jumper Up, horizontal jumper Right |