GE / ITI / UC Interrogator Program

Program
Caretaker +
None although book says to enable Sensor 77 (Keypad Tamper) I don’t recommend it
Program
Commander 2000
(Must do)

Enter Commander 2000 programming
1. Press AUX + AUX + STATUS + 20 (Tells Commander that Interrogator is there)
2. Press AUX + AUX + STATUS + 27 (Mutes speaker during two-way activation)
For Commander 2000 V5.3’s
Remove 97 trouble with “BYPASS 97” then wire Interrogator normally
Program
Concord Express
(Must do)
Set location 09110 (Output 2) as 01800 (AVM enable)
Program
Interrogator
(Normally the below is not needed)

Locally 1. Connect butt-set to Program Post and Diode on Interrogator (See diagram)
2. Buttset must be clipped to loop of wire that extends from top of diode down to circuit board
3. Power up panel and Interrogator
4. Move programming jumpers to programming positions
(Move vertical jumper down. Move horizontal jumper to left)
5. Enter Programming by * + # + 10 + 1234 + # (see program sheet on bottom of page)
6. Press 99 to exit Important! Move vertical jumper Up, horizontal jumper Right

Remote (if tech forgot butt-set, if you don’t get this right must wait 15 minutes to try again)
1. Call panel on regular phone, let ring three times then hang up or let ring 8 times
2. Wait 10 seconds and call back, Interrogator picks up on 1st or 2nd ring and beeps
3. Press * and enter login command * + # + 10 + 1234 + #
4. You can now go 2-way by pressing 1 or 4 to Talk, 3 or 0 to Listen, 99 to Hang up
or program the system by below Program Sheet
Program Sheet (Usually no programming below is needed)
* + # + 10 + 1234 + # Enters Interrogator Programming
* + # + 11 + # + 0 or 1 Turn Aux Output OFF (0) or ON (1)
* + # + 30 + ???? + # Set Interrogator Login Password
* + # + 31 + 0 or 1 + # Set Dialing format for Pulse (0) or DTMF (1)
* + # + 32 + ??? + # Phone Number (up to 20 digits, for pause hold 7 for 5 seconds)
* + # + 33 + 0 or 1 + # Off site Accessing OFF (0) or ON (1)
* + # + 34 + 0 to 7 + # Sets Unit ID number (Caretaker Plus and SX-V only)
* + # + 35 + ?? + X + # Determine which sensor activates which microphone

?? = Sensor Number (01 to 63)
X = Which microphone (1 to 3) for microphone 1 to 3)
* + # + 36 + ?? + # Delete sensor mapping done by above command
?? = Sensor Number (01 to 63)
* + # + 38 + ???? + # Interrogator 5-digit Account Number (never used)
* + # + 39 + ? + # Set Control panel type (1 to 2) connected to Interrogator
1 = Caretaker Plus (these settings not applicable to SX-V)
2 = Commander 2000
* + # + 40 + X + Y + # Trip Input and Trip Action

X = Trip Input Y = Trip Action
0 = Falling edge 0 = Instant ON, Activation Beeps
1 = Rising edge (SX-V) 1 = Instant ON, no Activation Beeps
2 = ITI Trip 2 = Callback, answer on 1st ring
(Caretaker +, Com 2000) 3 = Dial out after trip detect
4 = Callback, No On-site phone ring
* + # + 41 + > + # Interrogator Aux output option Disabled (0) or Enabled (1)
* + # + 42 + X + Y + # Auxiliary Output Time/Recording Save Time
V1.5 * + # + 42 + X + Y + + Z + # Auxiliary Output Time/Recording Save Time/CS Hold Time

X = Aux Output Time Y = Recording Save Time
0 = 5 seconds 0 = 10 minutes)
1 = 10 seconds 1 = 20 minutes
2 = 5 minutes 2 = 1 hour
3 = 10 minutes 3 = 5 hours
Z = Central Station Hold Time (v1.5 and higher only)
0 = 1 minute
1 = 2 minutes
2 = 3 minutes
3 = 4 minutes
* + # + 43 + ??? + # Sets House Code (001 to 255, must match Control panel)
* + # + 44 + ? + # Switches hot-key assignments (0 or 1 default is 0)

Default is 0 = 0 Listen 4 Talk 7 Extend 9 Terminate
Switched is 1 = 1 Talk 3 Listen 7 Extend 9 Terminate
* + # + 49 + # Clears Memory, defaults Interrogator
Press 99 to exit Important! Move vertical jumper Up, horizontal jumper Right