GE / ITI / UC Concord V2 Program

Click HERE for Programming Keys
Must be programmed with 60-746 Alpha Keypad (Green backlight)
Enter Program
1. While powered up plug in Programmer Keypad
2. Enable Programmer Keypad by entering 8 + Installer Code + 02
3. 8 + Installer Code + 00, keypad says “SYSTEM PROGRAMMING”
(Do not power up with Programmer connected to avoid Bus Errors later)
Move to Location From any menu (like SECURITY or GLOBAL) enter 4 or 5 digit “Shortcut”
(you cannot do this while IN a location)
Exit Program 1. Press * until “SYSTEM PROGRAMMING” appears
2. Press A or B keys until Keypad shows “EXIT PROGRAMMING” press #
3. Remove Programmer Keypad from connector on circuit board
Enable
Downloading
1. Press 9 + Master Code (“SYSTEM MENU” then “USER CODES”)
2. Press * + 40 + 2 + # (“Display shows “DOWNLOADING ON”)
3. Press * + 7 + # to exit
Send to
Downloader
Press 8 + Master or Installer Code + 7 + 0
Rescan Bus 8 + Installer Code + 01

Learn Sensor 1. Use shortcuts to go to location 080 (LEARN SENSORS) then press #
2. At “Sensor Partition” enter 1 or 2 then #
3. At “SENSOR GROUP” enter 2-digit Zone type then press #
CLICK HERE FOR COMPLETE LIST OF SENSOR TYPES
4. At “TRIP SENSOR xx” either learn by below or enter new Zone number then below

Door Sensor Remove cover (hardwired contacts learn while open)
Glassbreaks Make a lot of noise (keys, clap etc)
Motions Remove cover, may require pressing button
Heat Sensor Rub hands until warm, place on sensor 30 seconds
Smoke Hold Test button 30 seconds until Panel beeps
Keyfobs Hold LOCK and UNLOCK buttons 3 seconds
Encrypted Keyfob Unlock twice then HOLD until LED flashes, do this 3 times
Touchpads Press BYPASS button for 3 seconds
Hardwired Zones Open Zone (Any Hardwire Zone can be Zones 01 to 24)
5. If learned correctly keypad will say “Sensor OK” and go to next sensor
(Panel continues to learn same group, to change press ** then re-enter group)

Delete Sensor 1. Use shortcuts to go to location 082 (DELETE SENSORS) then press #
2. At “DELETE SENSOR xx” enter 2-digit sensor to delete press #
3 . Display will show “DELETE SENSOR xx DONE” press * to exit

Address Keypad 1. Press and hold D and 6 at same time
2. Display should show DA xx (xx = current address)
3. Press #, enter new 3-digit address (000 to 015 then press #
4. Press * to exit, then rescan bus with 8 + Installer Code + 01

Delete Unit ID (If Programmer was learned into system by power-up)
1. Enter programming, at “System Programming” press #
2. Press B key to move to “Accessory Modules” press #
3. Display shows “Bus Devices” press #
4. Display shows “Unit Type”
Second line shows “00 – LTP” (for LED Keypad) or “00 – ATP” (Alpha Keypad)

LTP = LED Keypad
ATP = Alpha Keypad
ESM = Energy Saver Module
HIM = Hardwire Input Module
HOM = Hardwire Output Module
PIV = Phone Interface & Voice Module
RCVR = Wireless Receiver
5. Press B to move to “01 – ATP” (should be location for Alpha programmer)
6. Press D to delete then * to exit
(If not sure which device it is delete everything (0 to 15), power down & back up)

Below locations are NOT COMPLETE but enough to do basic programming

SECURITY
GLOBAL (# saves, * exits)
Location Description Values Use Instead
0000 Downloader Code 12345
0001 Installer Code 4321
0002 Dealer Code None

PARTITION 1
(Press and Hold 1 to 6 for A to F)
Location Description Values Use Instead
0010 Partition 1 Account # (up to 10 digits) 00000 4 or 5-digits
0011 Quick Arm (1=OFF 2=ON) OFF
0012 Quick Exit (1=OFF 2=ON) ON
0013 Exit Extension (1=OFF 2=ON) ON
0014 Auto Stay Arming (1=OFF 2=ON) ON
0015 Keyswitch Sensor (ZONE 1 to 76) NONE
0016 Keyswitch Style 1=TRANSITION
2=STATE
TRANSITION
0017 Duress Code (1=OFF 2=ON) None

PARTITION 2
(Press and Hold 1 to 6 for A to F)
0020 Partition 2 Account # (up to 10 digits) 00000 4 or 5-digits
0021 Quick Arm (1=OFF 2=ON) OFF
0022 Quick Exit (1=OFF 2=ON) ON
0023 Exit Extension (1=OFF 2=ON) ON
0024 Auto Stay Arming (1=OFF 2=ON) ON
0025 Keyswitch Sensor (ZONE 1 to 76) NONE
0026 Keyswitch Style 1=TRANSITION
2=STATE
TRANSITION
0027 Duress Code (1=OFF 2=ON) NONE

PHONES
CS PHONE 1 (# saves, * exits)
Location Description Values Use Instead
0100 CS Phone Number (up to 24 digits) None
(Press C for 3 second pause, D deletes, hold 7 for *, hold 9 for # )
0101 High Level Reports (1=OFF 2=ON) ON
0102 Low Level Reports (1=OFF 2=ON) ON
0103 Exception Reports (1=OFF 2=ON) ON
0104 Opening/Closing Reports (1=OFF 2=ON) OFF
0105 Backup Reporting (1=OFF 2=ON) ON
0106 Report Format (1=SIA 2=CID) CID SIA

CS PHONE 2 (# saves, * exits)
Location Description Values Use Instead
0110 CS Phone Number (up to 24 digits) NONE
(Press C for 3 second pause, D deletes, hold 7 for *, hold 9 for # )
0111 High Level Reports (1=OFF 2=ON) ON
0112 Low Level Reports (1=OFF 2=ON) ON
0113 Exception Reports (1=OFF 2=ON) ON
0114 Opening/Closing Reports (1=OFF 2=ON) OFF
0115 Backup Reporting (1=OFF 2=ON) ON
0116 Report Format (1=SIA 2=CID) CID SIA

CS PHONE 3 (# saves, * exits)
Location Description Values Use Instead
0120 CS Phone Number (up to 24 digits) NONE
(Press C for 3 second pause, D deletes, hold 7 for *, hold 9 for # )
0121 High Level Reports (1=OFF 2=ON) ON
0122 Low Level Reports (1=OFF 2=ON) ON
0123 Exception Reports (1=OFF 2=ON) ON
0124 Opening/Closing Reports (1=OFF 2=ON) OFF
0125 Backup Reporting (1=OFF 2=ON) ON
0126 Report Format (1=SIA 2=CID) CID SIA

PAGER PHONE 1 (# saves, * exits)
Location Description Values Use Instead
0130 Phone Number (up to 24 digits) NONE
(Press C for 3 second pause, D deletes, hold 7 for *, hold 9 for # )
0131 High Level Reports (1=OFF 2=ON) OFF
0132 Low Level Reports (1=OFF 2=ON) OFF
0133 Exception Reports (1=OFF 2=ON) OFF
0134 Opening/Closing Reports (1=OFF 2=ON) OFF
0135 Latchkey Reports (1=OFF 2=ON) ON
0136 Streamlining (1=SIA 2=CID) ON
0137 Partition Assignment (1, 2 or 1 & 2) 1

PAGER PHONE 2 (# saves, * exits)
Location Description Values Use Instead
0140 Phone Number (up to 24 digits) NONE
(Press C for 3 second pause, D deletes, hold 7 for *, hold 9 for # )
0141 High Level Reports (1=OFF 2=ON) OFF
0142 Low Level Reports (1=OFF 2=ON) OFF
0143 Exception Reports (1=OFF 2=ON) OFF
0144 Opening/Closing Reports (1=OFF 2=ON) OFF
0145 Latchkey Reports (1=OFF 2=ON) ON
0146 Streamlining (1=SIA 2=CID) ON
0147 Partition Assignment (1, 2 or 1 & 2) 1

PAGER PHONE 3 (# saves, * exits)
Location Description Values Use Instead
0150 Phone Number (up to 24 digits) NONE
(Press C for 3 second pause, D deletes, hold 7 for *, hold 9 for # )
0151 High Level Reports (1=OFF 2=ON) OFF
0152 Low Level Reports (1=OFF 2=ON) OFF
0153 Exception Reports (1=OFF 2=ON) OFF
0154 Opening/Closing Reports (1=OFF 2=ON) OFF
0155 Latchkey Reports (1=OFF 2=ON) ON
0156 Streamlining (1=SIA 2=CID) ON
0157 Partition Assignment (1, 2 or 1 & 2) 1

PAGER PHONE 4 (# saves, * exits)
Location Description Values Use Instead
0160 Phone Number (up to 24 digits) NONE
(Press C for 3 second pause, D deletes, hold 7 for *, hold 9 for # )
0161 High Level Reports (1=OFF 2=ON) OFF
0162 Low Level Reports (1=OFF 2=ON) OFF
0163 Exception Reports (1=OFF 2=ON) OFF
0164 Opening/Closing Reports (1=OFF 2=ON) OFF
0165 Latchkey Reports (1=OFF 2=ON) ON
0166 Streamlining (1=SIA 2=CID) ON
0167 Partition Assignment (1, 2 or 1 & 2) 1

PAGER PHONE 5 (# saves, * exits)
Location Description Values Use Instead
0170 Phone Number (up to 24 digits) NONE
(Press C for 3 second pause, D deletes, hold 7 for *, hold 9 for # )
0171 High Level Reports (1=OFF 2=ON) OFF
0172 Low Level Reports (1=OFF 2=ON) OFF
0173 Exception Reports (1=OFF 2=ON) OFF
0174 Opening/Closing Reports (1=OFF 2=ON) OFF
0175 Latchkey Reports (1=OFF 2=ON) ON
0176 Streamlining (1=SIA 2=CID) ON
0177 Partition Assignment (1, 2 or 1 & 2) 1
DOWNLOADER PHONE
0180 Phone Number (up to 24 digits) NONE
(Press C for 3 second pause, D deletes, hold 7 for *, hold 9 for # )

PHONE OPTIONS
GLOBAL (# saves, * exits)
Location Description Values Use Instead
02000 Phone Test (1=OFF 2=ON) ON
02001 Auto Phone Test (1=OFF 2=ON) OFF
02002 Auto Test Reset (1=OFF 2=ON) ON
02003 Comm Failure (1=OFF 2=ON) ON
02004 DTMF Dialing (1=OFF 2=ON) ON
02005 Dialer Abort (1=OFF 2=ON) ON
02005 Pager Delay (0 to 255 sec) 15
02006 Dial Abort Delay (15 to 120 sec) 30
02007 Cancel Message (1=OFF 2=ON) ON
02008 Pager Delay (0 to 30 sec) 15
02009 Call Wait Cancel/Prefix NONE
(Press CC for pause, Hold 7 for 1 sec for *, hold 9 for 1 sec for # )
02010 Dial Tone Detect (1=OFF 2=ON) ON

PARTITION 1 (# saves, * exits)
Location Description Values Use Instead
0210 Local Phone Control (1=OFF 2=ON) ON
0211 Remote Access (1=OFF 2=ON) ON
0212 Ring/Hang/Ring (1=OFF 2=ON) ON
0213 Line Fail Delay (10 to 240 sec) NONE
0213 Toll Saver (1=OFF 2=ON) ON
0214 Phone Panic (1=OFF 2=ON) OFF
0215 Phone ACC (Access) Key (1 = * 2 = #) #

PARTITION 2 (# saves, * exits)
Location Description Values Use Instead
0220 Local Phone Control (1=OFF 2=ON) ON
0221 Remote Access (1=OFF 2=ON) ON
0222 Ring/Hang/Ring (1=OFF 2=ON) ON
0224 Toll Saver (1=OFF 2=ON) ON
0225 Phone Panic (1=OFF 2=ON) OFF
0226 Phone ACC (Access) Key (# or *) #

TIMERS
GLOBAL (# saves, * exits)
Location Description Values Use Instead
0300 Supervisory Time (00:00 to 23:99) 00:00
0301 RF Tx Timeout (2 to 24 Hours) 12
0302 Phone Test Frequency (01 to 255 Days) 07
0303 Next Phone Test (01 to 255 Days) 07
0304 Output Trip Time (01 to 12 sec) 04
0305 Activity Timeout (01 to 42 Hours) 24
0306 Daylight Savings (1=OFF 2=ON) ON

PARTITION 1 (# saves, * exits)
Location Description Values Use Instead
0310 Entry Delay (32 to 240 sec) 32
0311 Exit Delay (48 to 184 sec) 64
0312 Extended Delay (1 to 8 min) 4
0313 Siren Timeout (1 to 30 min) 4

PARTITION 2 (# saves, * exits)
Location Description Values Use Instead
0320 Entry Delay (32 to 240 sec) 32
0321 Exit Delay (48 to 184 sec) 64
0322 Extended Delay (1 to 8 min) 4
0323 Siren Timeout (1 to 30 min) 4

LIGHT CONTROL
PARTITION 1 (# saves, * exits)
Location Description Values Use Instead
0400 Entry Lights 23456789
0401 House Code 01-B

PARTITION 2 (# saves, * exits)
Location Description Values Use Instead
0410 Entry Lights 23456789
0411 House Code 01-B

TOUCHPAD OPTIONS
GLOBAL (# saves, * exits)
Location Description Values Use Instead
0500 Latchkey Zones (Zone 1 to 76) NONE

PARTITION 1 (# saves, * exits)
Location Description Values Use Instead
0510 Fire Panic (1=OFF 2=ON) ON
0511 Auxiliary Panic (1=OFF 2=ON) ON
0512 Police Panic (1=OFF 2=ON) ON
0513 Keychain Touchpad (1=OFF 2=ON) OFF
0514 Keychain Star is No Delay (1=OFF 2=ON) OFF

PARTITION 2 (# saves, * exits)
Location Description Values Use Instead
0520 Fire Panic (1=OFF 2=ON) ON
0521 Auxiliary Panic (1=OFF 2=ON) ON
0522 Police Panic (1=OFF 2=ON) ON
0523 Keychain Touchpad (1=OFF 2=ON) OFF
0524 Keychain Star is No Delay (1=OFF 2=ON) OFF

REPORTING
GLOBAL (# saves, * exits)
Location Description Values Use Instead
06000 24 Hour Tamper (1=OFF 2=ON) OFF
06001 Buffer Control (1=OFF 2=ON) OFF
06002 AC Back in Service (1=OFF 2=ON) ON
06003 Bypass Reports (1=OFF 2=ON) OFF
06004 Low CPU Battery (1=OFF 2=ON) ON
06005 Battery Restoral (1=OFF 2=ON) OFF
06006 Buffer Full Report (1=OFF 2=ON) OFF
06007 Zone Restorals (1=OFF 2=ON) OFF (Only wireless smokes will send restores)
06008 Two Trip Error (1=OFF 2=ON) OFF
06009 TP (Touchpad) Panic Report (1=OFF 2=ON) OFF
06010 AC Failure (1=OFF 2=ON) OFF
06011 Receiver Fail (1=OFF 2=ON) OFF
06012 RF Low Battery Report (1=DAY 2=WEEK) WEEKLY
06013 RF Supervisory Report (1=DAY 2=WEEK) WEEKLY
06014 Swinger Limit (1=1 Rpt 2=2) 1 Report per Armed Period
06015 Program (Installer) Report (1=OFF 2=ON) OFF

PARTITION 1 (# saves, * exits)
Location Description Values Use Instead
06100 Opening Reports (1=OFF 2=ON) OFF
06101 Closing Reports (1=OFF 2=ON) OFF
06102 Recent Closings (1=OFF 2=ON) ON
06103 No Activity (1=OFF 2=ON) OFF
06104 Duress Option (1=OFF 2=ON) OFF
06105 Force Armed (1=OFF 2=ON) OFF
06106 Latchkey Format (1=OFF 2=ON) OFF
06106 Freeze Alarm (1=OFF 2=ON) OFF
06107 Alarm Verify (1=OFF 2=ON) OFF
06108 System Tamper (1=OFF 2=ON) OFF

PARTITION 2 (# saves, * exits)
Location Description Values Use Instead
06200 Opening Reports (1=OFF 2=ON) OFF
06201 Closing Reports (1=OFF 2=ON) OFF
06102 Recent Closings (1=OFF 2=ON) ON
06203 No Activity (1=OFF 2=ON) OFF
06204 Duress Option (1=OFF 2=ON) OFF
06205 Force Armed (1=OFF 2=ON) OFF
06206 Latchkey Format (1=OFF 2=ON) OFF
06207 Freeze Alarm (1=OFF 2=ON) OFF
06208 Alarm Verify (1=OFF 2=ON) OFF
06209 System Tamper (1=OFF 2=ON) OFF

SIREN OPTIONS
GLOBAL (# saves, * exits)
Location Description Values Use Instead
0700 Immediate Trouble Beeps (1=OFF 2=ON) OFF
0701 Disable Trouble Beeps (1=OFF 2=ON) OFF
0702 UL 98 Option (1=OFF 2=ON) OFF
0703 SWS Supervision Code (1 to 255) ON
(System House Code for Supervised Wireless Sirens)
0704 Global Fire Siren (1=OFF 2=ON) OFF

PARTITION 1 (# saves, * exits)
Location Description Values Use Instead
0710 Siren Verify (1=OFF 2=ON) OFF

SENSORS
Location Description
080 Learn Sensors
081 Sensor Text Click HERE for all Alpha Zone List
Display shows Sn 01 ITEM 00
Enter 3-digit description from list or scroll list with B and A
Press # to save and move to next word or character (up to 16 total)
When finished press * to save and exit
082 Delete Sensor (Enter sensor then # to delete, * to exit)
083 Edit Sensor Group (Enter sensor, edit sensor Group, # saves, * exits)

Hardwire Defaults
Zone 1 10 Entry Exit
Zone 2 17 InteriorFollower
Zone 3 13 Instant Perimeter
Zone 4 13 Instant Perimeter
Zone 5 13 Instant Perimeter
Zone 6 13 Instant Perimeter
Zone 7 13 Instant Perimeter
Zone 8 13 Instant Perimeter
Learn Sensor
1 . Use shortcuts to go to location 080 (LEARN SENSORS) then press #
2. At “Sensor Partition” enter 1 or 2 then #
3. At “SENSOR GROUP” enter 2-digit Zone type then press #
CLICK HERE FOR COMPLETE LIST OF SENSOR TYPES
4. At “TRIP SENSOR xx” either learn by below or enter new Zone number then below

Door Sensor Remove cover (hardwired contacts learn while open)
Glassbreaks Make a lot of noise (keys, clap etc)
Motions Remove cover, may require pressing button
Heat Sensor Rub hands until warm, place on sensor 30 seconds
Smoke Hold Test button 30 seconds until Panel beeps
Keyfobs Hold LOCK and UNLOCK buttons 3 seconds
Encrypted Keyfob Unlock twice then HOLD until LED flashes, do this 3 times
Touchpads Press BYPASS button for 3 seconds
Hardwired Zones Open Zone (Any Hardwire Zone can be Zones 01 to 24)
4. If learned correctly keypad will say “Sensor OK” and go to next sensor
(Panel continues to learn same group, to change press ** then re-enter group)
Delete Sensor 1. Use shortcuts to go to location 082 (DELETE SENSORS) then press #
2. At “DELETE SENSOR xx” enter 2-digit sensor to delete press #
3. Display will show “DELETE SENSOR xx DONE” press * to exit

AUDIO VERIFICATION
PARTITION 1 (# saves, * exits)
Location Description Values
0900 Audio Verify (1=OFF 2=ON) Off
0901 Audio Mode (B selects) 01 01 = Instant
02 = Callback
03 = Silent Callback
0902 Fire Shutdown (1=OFF 2=ON) Off
0903 Silent Talkback (1=OFF 2=ON) Off
0904 Access Timeout (30 to 300 sec) 90
0905 Beep Delay (0 to 300 sec) 02
0906 AVM Callback Access Code (4 Digits) None
BUS DEVICES
DELETE UNIT ID 1. Enter programming, at “System Programming” press #
2. Press B key to move to “Accessory Modules” press #
3. Display shows “Bus Devices” press #
(Unit ID will match label on device or back-inside of keypads)
100000 Unit ID 1 (4 Digits) None
to
100015 Unit ID 15 None
(Press # to show below options)
Change ID ←A B → Device Partition ← A B → Keypad Options ← A B → Energy Options ← A B → Outputs
#↓ *↑ #↓ *↑ #↓ *↑ #↓ *↑ #↓ *↑
Device ID
?-??????
(? = Device)
(????? = Serial)
(Press D to delete)
Partition Assign
1 or 2
Status Beeps
On/Off
#↓ *↑
Key Beeps
On/Off
Freeze Temp
40 to 90F
#↓ *↑
Temperature
40 to 90F
Output
1 or 2
#↓ *↑
Partition Assign
1 or 2
#↓ *↑
Configuration
LTP = LED Keypad
ATP = Alpha Keypad
ESM = Energy Saver Module
HIM = Hardwire Input Module
HOM = Hardwire Output Module
PIV = Phone Interface & Voice Module
RCVR = Wireless Receiver
ONBOARD OPTIONS
OUTPUT 1 (# saves, * exits)
Location Description Values
11100 Partition Assign (1=1 2=1) 1
11001 Configuration 01614
1120 Output 1 Text

OUTPUT 2 (# saves, * exits)
Location Description Values
11110 Partition Assign (1=1 2=1) 1
11111 Configuration 01710
1121 Output 2 Text

First 3 digits = Trigger Click HERE for Trigger Options
Last 2 digits = Response Click HERE for Response Options

INPUTS (# saves, * exits)
Location Description Values
1100 Smoke Verify (1=OFF 2=ON) OFF
101001 Two-Wire Smoke (1=OFF 2=ON) OFF
10110 Output 1 Text
(If enabling 2-Wire Smoke this option must be enabled first before learning sensors!)

ACCESSORY MODULES
(If SuperBus Output Relay Module 60-770 is installed)
RELAY 1 (# saves, * exits)
Location Description Values
00100 Config Number 00100

RELAY 2 (# saves, * exits)
Location Description Values
00500 Config Number 00500

RELAY 3 (# saves, * exits)
Location Description Values
00200 Config Number 00100

RELAY 4
Location Description Values
00300 Config Number 00100

OUTPUT 1 (# saves, * exits)
Location Description Values
101000 Partition Assign (1=1 2=1) 1
101001 Configuration 01400
10110 Output 1 Text

OUTPUT 2 (# saves, * exits)
Location Description Values
101010 Partition Assign (1=1 2=1) 1
101011 Configuration 01400
10111 Output 2 Text

OUTPUT 3 (# saves, * exits)
Location Description Values
101020 Partition Assign (1=1 2=1) 1
101021 Configuration 00903
10112 Output 3 Text

OUTPUT 4 (# saves, * exits)
Location Description Values
101030 Partition Assign (1=1 2=1) 1
101031 Configuration 01003
10113 Output 4 Text