GE / ITI / UC Concord Express Program

Click HERE for Programming Keys
Must be programmed with 60-746 Alpha Keypad (Green backlight)
60-820 Fixed English keypad (Amber backlight) will not work!
Enter Program 1. While powered up plug in Programmer Keypad
2. Enable Programmer Keypad by entering 8 + Installer Code + 02
3. Press 8 + Installer Code + 00, keypad says “SYSTEM PROGRAMMING”
(Do not power up with Programmer connected to avoid Bus Errors later)
Move to Location Enter 4 or 5 digit “Shortcut” (you can’t do this while IN a location)
or press A and B to move through options (this is the slow way to move around)
Press # to enter a location
Press # to save data within a location
Press * to exit a location
Exit Program 1. Press * until “SYSTEM PROGRAMMING” appears
2. Press A or B keys until Keypad shows “EXIT PROGRAMMING” press #
3. Remove Programmer Keypad from connector on circuit board
(Do not power up system with Programmer keypad attached!)
Enable
Downloading
1. Press 9 + Master Code (“SYSTEM MENU” then “TIME/DATE”)
2. Press 2 + 0
3. Press 2 + # (“Display shows “DOWNLOADING ON”)
4. Press * + 4 + #
Send to
Downloader
8 + Master or Installer Code + 7 + 0
Scan Bus
Device
8 + Installer Code + 01 (Do not do this if programmer is attached)
Default Panel Short 2 solder points on main board for 20 seconds (will not default if phone lock enabled)
X-10 This panel does not support any X-10 devices directly however limited functions
can work if PowerFlash module is used

Learn Sensor
1. Use shortcuts to go to Location 070 (LEARN SENSORS) then press #
2. At “SENSOR GROUP” enter 2-digit Zone type then press #
3. At “TRIP SENSOR xx” either learn by below or enter new Zone number then below

Door Sensor Remove cover (hardwired contacts learn while open)
Glassbreaks Make a lot of noise (keys, clap etc)
Motions Remove cover, may require pressing button
Heat Sensor Rub hands until warm, place ON sensor 30 secONds
Smoke Hold Test buttON 30 seconds until Panel beeps
Keyfobs Hold LOCK and UNLOCK buttons 3 seconds
Encrypted Keyfob Unlock twice then HOLD until LED flashes, do this 3 times
Touchpads Press BYPASS buttON for 3 seconds
Hardwired Zones Open Zone (Any Hardwire Zone can be Zones 01 to 24)
4. If learned correctly keypad will say “Sensor OK” and go to next sensor
(Panel continues to learn same group, to change press ** then re-enter group)
Delete Sensor 1. Use shortcuts to go to Location 072 (DELETE SENSORS) then press #
2. At “DELETE SENSOR xx” enter 2-digit sensor to delete press #
3. Display will show “DELETE SENSOR xx DONE” press * to exit
Delete Unit ID (If Programmer was learned into system by power-up)
1. Enter programming, at “System Programming” press #
2. Press B key to move to “Accessory Modules” press #
3. Display shows “Bus Devices” press #
4. Display shows “Unit Type” , second line shows 0 + Serial number of device 0
5. Press D to delete serial number, display should show “Unit Type + NONE”
6. Press B to move to 1 + Serial Number of Device 1 and press D to delete
The below Locations are in no particular order other than ease of finding
CODES (# saves, * exits)
Location Description Default Suggested
0000 Downloader Code 12345 12345
0001 Installer Code 4321 4321
0002 Dealer Code None
0011 Quick Arm (1=OFF 2=ON) OFF
0012 Keyswitch Arming (1=OFF 2=ON) OFF
0013 Exit Extension (1=OFF 2=ON) ON
0014 Auto Stay Arm (1=OFF 2=ON) ON
0015 Keyswitch Sensor None
0016 Duress Code None 2580

RECEIVER PHONE 1 (# saves, * exits)
Location Description Default Suggested
0100 CS Phone Number (24 digits) None
(Press C for 3 second pause, D deletes, hold 7 for *, hold 9 for # )
0010 Partition One Account Number (up to 10 digits) 00000
(Press and Hold 1 to 6 for A to F)
0101 High Level Report Phone (1=OFF 2=ON) ON
0102 Low Level Report Phone (1=OFF 2=ON) ON
0103 Open/Close Report Phone (1=OFF 2=ON) OFF
0104 Backup Reporting Phone (1=OFF 2=ON) ON
0105 Report Format CS Phone (1=SIA 2=CID) CID SIA
0510 Opening Reports (1=OFF 2=ON) OFF
0511 Closing Reports (1=OFF 2=ON) OFF
0512 Recent Closings (1=OFF 2=ON) ON
0513 No Activity Reports (1=OFF 2=ON) OFF
0514 Duress Option (On Enables) (1=OFF 2=ON) OFF ON
0515 Force Armed Reports (1=OFF 2=ON) OFF
0516 Alarm Verify (1=OFF 2=ON) OFF
0517 System Tamper (1=OFF 2=ON) OFF
05010 AC Failure (1=OFF 2=ON) OFF ON
05004 Low CPU Battery (1=OFF 2=ON) ON
05007 Zone Restorals (1=OFF 2=ON) OFF

PAGER PHONE 1 (# saves, * exits)
Location Description Default Suggested
0120 Pager Phone Number (1=OFF 2=ON) None
0121 High Level Reports Pager (1=OFF 2=ON) OFF
0122 Low Level Reports Pager (1=OFF 2=ON) OFF
0123 Open/Close Reports Pager (1=OFF 2=ON) OFF
0124 Latchkey Reports (1=OFF 2=ON) ON
0125 Streamlining (Account won’t show in Pager) ON
02008 Pager Delay (0 – 30 Sec) 15 Seconds
(Sets delay between pager number dialed and actual paging signal)

DOWNLOAD OPTIONS (# saves, * exits)
Location Description Default Suggested
0150 Downloader Phone Number (24 digits) None
0210 Remote Access (1=OFF 2=ON) ON
0211 Ring/Hang/Ring (1=OFF 2=ON) ON
If needed enter Download Number and have tech send panel to you with 8 + Installer + 7 + 0

SYSTEM TIMES (# saves, * exits)
Location Description Default Suggested
0310 Entry Delay (32 to 240 sec) 32
0311 Exit Delay (48 to 184 sec) 64
0312 Extended Delay (1 to 8 min) 4
0313 Siren Timeout (1 to 30 min) 4

PHONE OPTIONS (# saves, * exits)
Location Description Default Suggested
02000 Phone Test (1=OFF 2=ON) ON
02001 Auto Phone Test (1=OFF 2=ON) OFF
02002 Auto Test Reset (1=OFF 2=ON) ON
02003 Comm Failure (1=OFF 2=ON) ON
02004 DTMF Dialing (1=OFF 2=ON) ON
02005 Dialer Abort (1=OFF 2=ON) ON
02006 Dialer Abort Delay (15 to 120 sec) 30 Seconds
02007 Cancel Message (1=OFF 2=ON) ON
02009 Call Wait Cancel (1=OFF 2=ON) OFF

KEYPAD OPTIONS (# saves, * exits)
Location Description Default Suggested
0400 Fire Panic Enable (1=OFF 2=ON) ON
0401 Auxiliary Panic Enable (1=OFF 2=ON) ON
0402 Police Panic Enable (1=OFF 2=ON) ON
0403 Keyfob Touchpad Arm (1=OFF 2=ON) OFF
0404 Star key is No Delay (1=OFF 2=ON) OFF

ONBOARD OPTIONS (# saves, * exits)
Location Description Default Suggested
0900 Smoke Verify (1=OFF 2=ON) OFF
0901 Zone 6 2-Wire Smoke Enable (1=OFF 2=ON) OFF
(Program this first before learning 2-Wire smoke)
09100 Output 1 (+ Output) 00410 (Default for regular Siren)
09110 Output 2 (- Open Collector) 01710 (Status & Alarm Tones)
Program Output 2 as —>
01500 for 4-wire Smoke Detectors
01800 for Interrogator 2-Way Voice
01400 if X-10 Universal Module with Garage Door
(Uses keyfob * to activate, location 0404 must be OFF)
01401 if X-10 Universal Module with Lamp Module
(This only turns Lamp on for 3 minutes)
00402 if X-10 Universal Module with X-10 PowerHorn
(Sounds for length of Siren Timeout in location 303)
Note: System has very primative X-10 capabilities, can’t do timed Lights
First 3 digits = Trigger Click HERE for Trigger Options
Last 2 digits = Response Click HERE for Response Options

SENSORS (# saves, * exits)
Location Description
070 Learn Sensors
071 Sensor Text Click HERE for all Alpha Zone List
Display shows Sn 01 ITEM 00
Enter 3-digit description from list or scroll list with B and A
Press # to save and move to next word/haracter (up to 16)
When finished press * to save and exit
072 Delete Sensor (Enter sensor then # to delete, * to exit)
073 Edit Sensor Group (Enter sensor, edit sensor Group, # saves, * exits)
Hardwire Defaults
Zone 1 10 Entry Exit
Zone 2 17 InteriorFollower
Zone 3 13 Instant Perimeter
Zone 4 13 Instant Perimeter
Zone 5 13 Instant Perimeter
Zone 6 13 Instant Perimeter
Add Sensor
1. Go to “Learn Sensors” by entering shortcut 070 then press #
2. At “Enter Group Number” enter sensor type then #
CLICK HERE FOR COMPLETE LIST OF SENSOR TYPES
3. Select Sensor (01 to 24) by pressing A or B key then #
4. At “Trip Sensor” prompt open hardwired door or trip wireless tamper
5. Keypad should beep and ask to trip next sensor
6. If done press * * to exit or * once to “Enter Group” and learn next sensor
(If mistake is made with Group Number go to 073 to change without deleting sensor)
Erase Sensor 1. Go to “Learn Sensors” by entering shortcut 072 then press #
2. At “Delete Sensor” press A or B to move to desired sensor (01 to 24) then #
3. Keypad should say “Delete Sensor (01 to 24) Done”
4. Press * to exit

*****Usually the below options do not need programming*****
RECEIVER PHONE 2 (# saves, * exits)
Location Description Default Suggested
0110 CS Phone Number 2 (24 digits) None
0111 High Level Reports Phone 2 (1=OFF 2=ON) ON
0112 Low Level Reports Phone 2 (1=OFF 2=ON) ON
0113 Open/Close Reports Phone 2 (1=OFF 2=ON) OFF
0114 Backup Reporting Phone 2 (1=OFF 2=ON) ON
0115 SIA/CID Reporting Phone 2 (1=SIA 2=CID) CID SIA

PAGER PHONE 2 (# saves, * exits)
Location Description Default Suggested
0130 Pager Phone Number 2 (24 digits) None
0131 High Level Reports Pager 2 (1=OFF 2=ON) OFF
0132 Low Level Reports Pager 2 (1=OFF 2=ON) OFF
0133 Open/Close Reports Pager 2 (1=OFF 2=ON) OFF
0134 Latchkey Reports (1=OFF 2=ON) ON
0135 Streamlining (Account won’t show in Pager) ON

PAGER PHONE 3 (# saves, * exits)
Location Description Default Suggested
0140 Pager Phone Number 1 (24 digits) None
0141 High Level Reports Pager 1 (1=OFF 2=ON) OFF
0142 Low Level Reports Pager 1 (1=OFF 2=ON) OFF
0143 Open/Close Reports Pager 1 (1=OFF 2=ON) OFF
0144 Latchkey Reports (1=OFF 2=ON) ON
0145 Streamlining (Account won’t show in Pager) ON

MISC TIMERS (# saves, * exits)
Location Description Default Suggested
0300 Supervisory Time (HH:MM) 00:00
0301 RF Tx Timeout (nn hours) 12
0302 Phone Test Frequency (nn days) 7
0303 Next Phone Test (nn days) 1 – 255
0304 Output Trip Time (nn sec) 4
0305 Activity Timeout (nn hours) 24
0306 Daylight Savings Time Enable (1=OFF 2=ON) ON

MISC REPORTING (# saves, * exits)
Location Description Default Suggested
05000 24 Hour Tamper (1=OFF 2=ON) OFF
05001 Buffer Control (1=OFF 2=ON) OFF
05002 CPU Back in Service (1=OFF 2=ON) ON
05003 Bypass Reports (1=OFF 2=ON) OFF
05005 Battery Restoral (1=OFF 2=ON) OFF
05006 Buffer Full Report (1=OFF 2=ON) OFF
05008 Two Trip Error (1=OFF 2=ON) OFF
05009 TouchPad Panic Report Fmt (1=OFF 2=ON) OFF
05011 Receiver Failure Report (1=OFF 2=ON) OFF
05012 RF Low Bat Report (ON=Week OFF=Day) ON
05013 RF Supervisory Report (ON=Day OFF=Week) OFF
05014 Swinger Limit (1 – 2 alarms) 1

SIREN OPTIONS (# saves, * exits)
Location Description Values Use Instead
0600 Immediate Beeps (1=OFF 2=ON) OFF
0601 Disable Trouble Beeps (1=OFF 2=ON) OFF
0602 UL 98 Options (1=OFF 2=ON) OFF
0610 Siren Verify (1=OFF 2=ON) OFF

UNIT ID (Press D to delete a module)
Location Description Values
0800 Unit 0 ID (this is usually fixed english keypad) 1 – nnnnnnnn
0801 Unit 1 ID (this is usually programmer keypad) 2 – nnnnnnnn
0802 Unit 2 ID 3 – nnnnnnnn
0803 Unit 3 ID 4 – nnnnnnnn
IF Bus Failure occures it’s likely the tech has learned programming keypad into panel
and must be deleted here, if unsure which Unit ID it learned into delete them all,
then power down system, remove program keypad and power up