GE / ITI / UC Concord 4 Trouble

Bus Failure A Keypad or other Module has trouble communicating with Panel
AC Power
Failure
No Power to the panel
Low Batt Panel battery is low
Sensor
Supervisory
There is a problem with how the sensor is communicating with the panel.
1. Test the sensor in Test Mode.   8 + CODE + 3 (CODE + 1 to exit)
2. If testing the sensor does not clear the trouble condition, the sensor may need to be replaced.
Sensor Trouble Sensor may have internal problem or fire/smoke may not have properly reset, or sensor may be dirty
1. Test the sensor in Test Mode.   8 + CODE + 3 (CODE + 1 to exit)
2. If testing the sensor does not clear the trouble condition, the sensor may need to be replaced.
Sensor xx
Low Battery
A sensor has a low battery.
1. Disarm the system.
2. Remove the sensor cover. If the battery is an Alkaline AA or AAA, change the battery.
Sensor xx
Tamper
A sensor cover is off or open. Secure the cover and trip the sensor to clear the tamper condition.
Phone Failure
Trouble
The system can’t communicate with the central monitoring station.
Receiver
Failure
There is a receiver failure or receiver interference problem. Service required
Memory
Failure
There is a system memory failure. Service required
Auxiliary Phone
Trouble x
There is a problem with the cellular backup reporting portion of your system.
Aux Power
Fail
There is a problem with the power supplied to parts of the system. Call your security dealer for service.
Sensor Failure If displays SENSOR FAILURE and sirens sound a long, low- pitched beep when a zone or sensor is tripped,
indicates the wireless sensor signal strength is below acceptable limits.
Distance from receiver, installation environment, or both, are affecting the sensor signal strength