GE / ITI / UC Concord 4 Basics
Zones | 8 on board, up to 96 | ||||||
Wireless | Yes | ||||||
Transformer | 16.5 VAC 40 VA | ||||||
Battery | 12 VDC 4.5/7 AH Lead-Acid battery | ||||||
Downloadable | Yes Note: Cannot be armed/disarmed through download | ||||||
Event Log | Yes Up to 250 Events | ||||||
Partitions | 8 | ||||||
Panics |
|
||||||
Arm Stay | 2 + User Code | ||||||
Arm Away | 3 + User Code | ||||||
Stay Instant | 2 + User Code + 4 | ||||||
Away Instant | 3 + User Code + 4 | ||||||
Disarm | 1 + User Code (Do twice to reset fire) | ||||||
Quick Arm |
(If enabled) Hold 2 for 2 seconds for Away Hold 3 for 2 seconds for Stay |
||||||
Arm Silently | Press 5 before arming | ||||||
Status | * once for short status * + * for full status | ||||||
Silence Trouble |
1.Press * 2. 1 + User Code 3. Press * 4. 1 + User Code Note: Beeping will start again either 4 or 10 hours later |
||||||
Door Chime | 7 + 1 | ||||||
Force Arm |
2 + User Code + # for Stay 3 + User Code + # for Away |
||||||
Bypass |
Close all sensors, Arm System, Press # + User Code + Zone Number OR Leave open what you want to bypass, Arm system, press # |
||||||
Sensor Test | 8 + CODE + 3 (CODE + 1 to exit) | ||||||
Set Time |
1. Enter the programming menus by pressing 9 + System or Partition master code 2. Press 020. 3. Enter the correct time in 24-hour format then press # (For example, if the current time is 7:23 a.m., press 0723 + #) 4. Press * + 00 + # to exit the programming Menus |
||||||
Set Date |
1. Enter the programming menus by pressing 9 + System or Partition master code. 2. Press 021. 3. Enter the current date as 6 digits (mm/dd/yy) then press #. (For example, if the current date is January 15, 2000, press 011500 + #) 4. Press * + 00 + # to exit the programming menus |
||||||
View Event History |
8 + User Code + 8 A Key goes Back, B Key goes Forward C Key Toggles between Date/Time and Details * to exit |
||||||
Keypad Pitch |
Press and hold * + 0 until you hear a steady tone then release Press 1 and hold to lower the pitch Press 2 and hold to raise the pitch It will exit after 15 seconds of no buttons being pressed |
||||||
Voice Volume |
(This is only for Voice Modules) 1. 9 + Master Code + 044 2. Select Volume level 1 thru 7 (7 being the loudest) and press # 3. Press * + 00 + # to exit |
||||||
Keypad Brightness |
1. 9 + Master Code + 043 2. Select a brightness level: 0 + # Off 1 + # Low 2 + # Medium 3 + # High 4. Press * + 00 + # to exit the programming menus. Note: After pressing a button or during an alarm the keypad will return to full brightness for 15 seconds |