GE / ITI / UC Commander 2000 Program

Format ITI or 4/2 (Always use ITI)
Enter Program 1. Loosen screws under keypad
2. Lower bottom tray
3. Press 4321, all lights should flash, if not Installer Code was Changed
(Download with CS-4000 Receiver to change code back to default)
Exit Program Raise battery tray and tighten screws (Lights stop flashing)

Default Panel POLICE + POLICE + MEDICAL + MEDICAL (“Memory Goodbye”)
House Code FIRE + FIRE + [001 to 254] (Use only with X-10 devices)
Duress Code POLICE + POLICE + [00 to 99] (use 99) (“xx OK!”)
Siren Timeout MEDICAL + MEDICAL + [2 to 9] minutes (“xx OK!”)
Entry Delay POLICE + POLICE + STATUS + [8 to 88 sec] (“xx OK!”)
Exit Delay POLICE + POLICE + BYPASS + [8 to 88 sec] (“xx OK!”)
Account Number FIRE + FIRE + STATUS + Last 5 of Account
(A to F can only be added by CS-4000 Receiver)
(0 as 1st digit if 4-digit account)
Receiver Number FIRE + FIRE + BYPASS + [up to 18 digits] (If you cannot change this Phone Lock is enabled) (for pause press FIRE FIRE)
Read Phone FIRE + FIRE + BYPASS (“Phone 1 8 x x etc”)
Delete Phone FIRE + FIRE + BYPASS + 1 (“Phone OFF”)
Report Format COMMAND + AUX + AUX + [00 to 03] 00 = ITI (Default)
01 = 4/2 2300 HZ
03 = 4/2 1400 Hz
Installer Code AUX + AUX + BYPASS + New Code twice (Also enables Phone Lock)
Hear All Sensors Press STATUS
Do not use Simon sensors with AA batteries, use only older “Crystal” 3.5 Lithium Sensors!
Learn Sensor 1. Press STATUS + Group [00 to 29] (Keypad says “Sensory Level xx”)
Common Groups
01 = Audible Panic 17 = Motions
03 = Silent Panic 20 = Delayed Motion
10 = Entry Exit 26 = Fire
13 = Instant
CLICK HERE FOR COMPLETE LIST OF SENSOR TYPES
2. Enter Zone Number [01 to 17] (Keypad says “Sensor xx”)
3. Learn sensor by doing the following

Door Sensor Remove cover (hardwired contacts learn while open)
Glassbreaks Make a lot of noise (keys, clap etc)
Motions Remove cover, may require pressing button
Heat Sensor Rub hands until warm, place on sensor 30 seconds
Smoke Hold Test button 30 seconds until Panel beeps
Keyfobs Hold LOCK and UNLOCK buttons 3 seconds
Touchpads Press BYPASS button for 3 seconds
Hardwired Zn 18 If normally closed sensor learn with door open (close then open)
If normally open sensor learn with door closed (open then close)
4. If learned correctly keypad will say “Sensor OK” and go to next sensor
(Panel continues to learn in same group, to change group go back to step 1)
Erase Sensor Press BYPASS + Sensor [01 to 18] (Keypad says “Sensor xx Goodbye!”)
Learn Keyfob 1. Learn like standard Sensor using Group 01 (Audible Panic) or 03 (Silent Panic)
or
2. STATUS + STATUS + [1 to 4] + press LOCK & UNLOCK on keyfob
Delete Keyfob 1. BYPASS + Sensor [01 to 17] or
2. BYPASS + BYPASS [1 to 4]
(if learned by Step 1 above)

(if learned by Step 2 above)

Featured
Numbers
(Normally not needed, For Interrogator 2-way support turn ON F20 & F27)
(Press AUX + AUX + STATUS + [20 to 27] to Enable or Disable)

F20 ON = Interrogator support OFF = Disabled (Default=OFF)
F21 ON = Battery power only OFF = AC Power (Default=OFF)
F22 ON = Tone Dialing OFF = Pulse Dialing (Default=ON)
F23 ON = Open/Close Reports OFF = Only in Event Buffer (Default=OFF)
F24 ON = Hardwire Zone N/O OFF = N/C (Default=OFF)
F26 ON = COMMAND 1 disarms OFF = Code Required (Default=OFF)
F27 ON = Panel Sounds disabled OFF = Sounds enabled (Default=OFF)
Signals ITI
01 to 18 Zone alarms
80 Touchpad Fire Panic
81 Touchpad Police Panic
82 Touchpad Auxiliary Panic
83 Phone Test (Level 8)
84 Opening Report (Optional)
85 Closing Report (Optional)
86 Duress Alarm Report
87 Force Armed/ Auto Force Arm
90 AC Failure
91 Low Battery
92 CPU Tamper
93 Auto Phone Test
94 Receiver Failure
95 CPU Back in Service (AC Restored)
96 Fail To Communicate
97 Wiring problem with Exterior Siren (v5.3 only)
98 Auto Event Buffer
Signals 4/2
Description Zone   Alarm   Trouble   Cancel   Restore
Wireless 01 01 B1 39
Wireless 02 02 B2 40
Wireless 03 03 B3 41
Wireless 04 04 B4 42
Wireless 05 05 B5 43
Wireless 06 06 B6 44
Wireless 07 07 B7 45
Wireless 08 08 B8 46
Wireless 09 09 B9 47
Wireless 10 10 C0 48
Wireless 11 11 C1 49
Wireless 12 12 C2 50
Wireless 13 13 C3 51
Wireless 14 14 C4 52
Wireless 15 15 C5 53
Wireless 16 16 C6 54
Wireless 17 17 C7 55
Hardwire 18 18 C8 56
Keypad Fire 80 F2
Keypad Police 81 81 F3
Keypad Medical 82 82 F4
Phone Test 83 83
Opening 84 84
Closing 85 95
Duress 86 86
Force Arm 87 87
RF low Battery 89 F9
AC Failure 90 90 FC
Panel Low Batt 91 91 FD
Panel Tamper 92 92 F3?
Auto Phone Test 93 93
Receiver Failure 94 94
Back in Service 95 95
Phone Failure 96 97
Auto Event Dump 98 98

CS-4000 Commands
ACCT or
ACCOUNT

<XX-XX>

Account Number (0 as 1st digit if 4-digit account)
ACCESS <4-digits> Programs Master Code
ALARMQ Views last 6 events of Alarm history
ANS 1 Connects CS-4000 to Panel
BATTLIFE <1 to 30> Battery Life? in Hours
BYPASS or
BYP

(00 to 16)

Bypasses Sensors
DELETE or
DEL

(00 to 16)

Deletes Sensors
DURESS <00 to 99> Hostage/Duress Code (usually 99)
ENTRY <8 to 88> Entry Delay (seconds)
EXIT <8 to 88> Exit Delay (seconds)
GROUP <zone>
<zone type>
Changes Zone type (Commander 17 2.6 only)
Freeze GROUP <zone> 01 L
Fire GROUP <zone> 02 D
Delay GROUP <zone> 04 L
Instant GROUP <zone> 05 L
Interior Inst Follower GROUP <zone> 06 L
Interior Follower GROUP <zone> 06 I
Silent Police Panic GROUP <zone> 12 A
Audible Medical Panic GROUP <zone> 01 B
HOUSE <1 to 255> Views House Code
INIT <00 to 16> Initializes Sensors
MACCESS <2 to 6>
<4 digits>
Programs Secondary Codes
(Commander 8 only has 1 secondary Code)
OPTION <20 to 27>
<ON or OFF>
Turns Functions ON/OFF (xx = 20 to 27)

F20 ON = Enable Interrogator OFF = Disables
F21 ON = DC Power Monitored OFF = Not Monitored
F22 ON = Dialing Format OFF = Pulse
F23 ON = Retain O/C only OFF = Retain All Events
F24 ON = Hardwire Loop NO OFF = Normally Closed OFF
F26 ON = Quick Disarm Enabled OFF = Disabled
F27 ON = Panel Alarm Mute OFF = Alarm Output Normal
Note: F20 and F27 must be ON for Interrogator
PLOCK ????
%XXXXXXXX
Changes Installer Code
???? = Old Installer Code
XXXX = New Installer Code Twice
PFORMAT <0 to 2> Report Format (0=ITI, 1=4×2, 1400hz, 2=4/2, 2300hz)
PHONE <7 to 4 digits> Primary Receiver (D = Pause)
PHONE2 <7 to 4 digits> Secondary Receiver (Commander 17 only)
PLEVEL <1 to 3< Changes Arming Level
PLEVEL 1 = Disarm
PLEVEL 2 = Arm Home
PLEVEL 3 = Arm Away
RECALL Causes panel to disconnect then call back to CS receiver
REL Releases Panel from CS-4000 receiver
SIREN <1 to 9> Siren Timeout in Minutes
STIME <hh:mm> Supervisory Report Time
UPD Sends updated programming to panel
ZONES Lists all Zones including Panics & Supervisory