Location |
Suggest |
Options |
01 – |
Dialing Type |
0 toggles to Touch Tone |
Touch Tone
Pulse Dial
|
02 – |
Phone 1 Number |
(16 digits) I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I
* 3 (C) = 3 Second Pause * 6 (F) erases entire line
|
03 – |
Phone 1 Receiver Type |
0 toggles to 20PPS 2300HZ |
1400HZ
2300HZ
|
04 – |
Phone 1 Format |
0 toggles to 4×2 |
Standard
4×2
Partial Extended
Extended
FBIII
BFSK
|
05 – |
Phone 2 Number |
(16 digits) I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I
* 3 (C) = 3 Second Pause * 6 (F) erases entire line
|
06 – |
Phone 2 Receiver Type |
Do not Program |
1400HZ
2300HZ
|
07 – |
Phone 2 Format |
Do not Program |
Standard
4×2
Partial Extended
Extended
FBIII
BFSK
|
08 – |
Partitioning |
0 toggles No |
Yes = Partition 2 Enabled
No = 1 Partition only
|
|
(Keypad Partitioning is set by Switch 4 on keypad) |
09 – |
Cross Partition |
0 toggles to Yes |
Yes = User 1 valid in both Partitions
No = User Code 1 Partition 1 only
|
|
(Allows User Code #1 access to both partitions) |
10 – |
Partition 1 Account to Phone 1 |
I_ _I_ _I_ _I_ _I |
*+1 = A *+2 = B
*+3 = C *+4 = D
*+5 = E *+6 = F
|
11 – |
Partition 1 Account to Phone 2 |
I_ _I_ _I_ _I_ _I |
12 – |
Partition 2 Account to Phone 1 |
I_ _I_ _I_ _I_ _I |
13 – |
Partition 2 Account to Phone 2 |
I_ _I_ _I_ _I_ _I |
14 – |
Installer Code |
I_1_I_2_I_3_I_4_I_5_I_6_I |
15 – |
Callback Number |
(Do not use) I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I
* 3 (C) = 3 Second Pause * 6 (F) erases entire line
|
16 – |
Bell Ringback |
0 toggles to No |
Yes = Bell Ringback on Arm
No = No Bell Ringback
|
17 – |
Open Close Type |
0 toggles to No Transmission |
No Transmission
CS#1 with Backup CS#2
Split Reporting
|
18 – |
Test Type |
0 toggles to No Transmission |
No Transmission
Sunday to Saturday
12 Hours
24 Hours
|
19 – |
Test Time |
00 |
00 = Disabled
01 to 23 Hours
|
20 – |
Siren Lockout |
0 toggles to No |
Yes = Enabled
No = Disabled
|
21 – |
Bell Test on Arming |
0 toggles to No |
Yes = Siren on Arming
No = No Siren on Arming
|
22 – |
Restore Follows Loop |
0 toggles to No |
Yes = Restores follow Loop
No = Restores follow Bell Timeout
|
23 – |
Exit Delay |
0 toggles to 60 Seconds |
15 to 50 seconds |
24 – |
Entry Delay |
0 toggles to 30 Seconds |
15 to 120 seconds |
25 – |
Burg Cut-Off Time |
0 toggles to 6 Minutes |
3 to 42 minutes, Infinite
Infinite = No Cutoff
|
26 – |
Fire Cut-Off Time |
0 toggles to 6 Minute |
s 2 to 28 minutes, Infinite
Infinite = No Cutoff
|
27 – |
Abort Transmission |
0 toggles to No Abort |
No Abort
Stop on Abort
|
28 – |
Trouble Report Code |
7 |
0 = No Report, 1 to F
2nd digit = Zone
|
29 – |
Bypass Report Code |
0 |
0 = No Report, 1 to F
2nd digit = Zone
|
30 – |
Opening Report Code |
0 |
0 = No Report, 1 to F
2nd digit = Zone
|
31 – |
Closing Report Code |
0 |
0 = No Report, 1 to F
2nd digit = Zone
|
32 – |
Test Code |
00 |
00 = No Report, 1 to F
2nd digit = Zone
|
33 – |
AC Loss Report Codes |
|
00 = No Report, 1 to F |
|
# toggles between fields |
 |
|
Trouble is digit programming in Location 28 + 1st digit here (79)
Restore is 2nd digit + 1st digit (E9)
|
34 – |
Low Bat Report Code |
|
00 = No Report, 1 to F |
|
# toggles between fields |
 |
|
Trouble is digit programming in Location 28 + 1st digit here (78)
Restore is 2nd digit + 1st digit (E8)
|
35 – |
Zone 1 to 16 Type |
|
This is Multiple Entry in this order ZONE TYPE SENSOR TYPE CHIME |
|
|
# |
toggles between options |
0 |
changes individual option |
INSTANT |
moves to next Zone |
CODE |
moves to previous Zone |
|
|
Zone Types |
Sensor Type |
Chime |
Delay Zone |
EOL |
YES |
Interior |
N/O |
NO |
Interior Follower |
N/C |
|
Perimeter |
|
|
Silent Panic |
|
|
Audible Panic |
|
|
Day Trouble |
|
|
24 Hr Trouble |
|
|
Fire Zone |
|
|
|
36 – |
Zone 1 to 16 Alarm/Restore Report Codes |
|
This is Multiple Entry in this order ALARM RESTORE |
|
Screen shows (ex: Zone 12) |
 |
|
# |
toggles between options |
Burg Zones should be |
31 to 39, 41 to 47 |
0 |
changes individual option |
Fire Zones should be |
16 |
INSTANT |
moves to next Zone |
Panic Zones should be |
25 |
CODE |
moves to previous Zone |
Restore should always be |
0 (Disabled) |
|
37 – |
KP Police, Fire and Medical Panics & Duress Characteristics |
|
This is Multiple Entry in this order AUD/SILENT REPORT CODE |
|
Screen shows (ex: Police Panic) |
 |
|
# |
toggles between options |
Panics appear in this order |
0 |
changes individual option |
1 Panic |
INSTANT |
moves to next Panic |
2 Fire (must always be Audible) |
CODE |
moves to previous Panic |
3 Auxiliary/Medical |
|
|
4 Duress (must always be Silent) |
|