FBI XL4800 Basics
Zones | 16 Hardwired | ||||||||||||
Battery | 12 volt rechargeable Gel-Cell inside main panel | ||||||||||||
AC Transformer | 16.5 volts (not 12 like other FBII panels) | ||||||||||||
Wireless | No | ||||||||||||
Downloading | Yes | ||||||||||||
Partitions | 2 | ||||||||||||
Panic Buttons |
|
||||||||||||
Arm | 4-digit Code (READY light MUST be ON) | ||||||||||||
Silence Alarm | 4-digit Code, enter code again to reset display | ||||||||||||
Stay Arm | STAY + 4-digit Code (Can also press INSTANT & STAY + 4-digit Code) | ||||||||||||
Instant Arm | INSTANT + 4-digit Code (Can also press INSTANT & STAY + 4-digit Code) | ||||||||||||
Force Arm | # 2 (Bypasses open zones while Arming) | ||||||||||||
Disarm | 4-digit Code | ||||||||||||
Bypass |
BYPASS + Zone (01 to 16) (If needing to bypass more zones press BYPASS + (01 to 16) again) |
||||||||||||
Quick Bypass | (If enabled) Press BYPASS + Zone (01 to 16) | ||||||||||||
Reset Smoke |
4-digit code + * (If this does NOT reset smoke set for service, smoke is bad) |
||||||||||||
Multi-Partition |
# 0 + Master Code + 1 for Partition 1 or 2 for Partition 2 (Allows Master Code to go to another Partition) |
||||||||||||
Door Chimes | # 6 + 0 to toggle On/Off, press * to exit | ||||||||||||
Quick-Arm | # 1 | ||||||||||||
Siren Test | There is no Siren Test | ||||||||||||
Below Commands only work with LCD keypads | |||||||||||||
Zone Directory | Press # 4, keypad will scroll names of all zones then exit | ||||||||||||
Set Time |
|
||||||||||||
View Time | # 3 # | ||||||||||||
Event Buffer |
CODE key + * + <Installer Code> + 6 use STAY to go backwards through buffer, BYPASS to move forward System with LED Keypads must be downloaded |