L1 |
Dialer Formats |
L2 |
Receiver Type |
0 |
Pulse Dialing, Standard Format or 4×2 |
0 |
10PPS 1400Hz No Parity |
1 |
TouchTone, Standard Format or 4×2 |
1 |
10PPS 1400Hz Parity |
2 |
Pulse Dialing, Extended Format |
2 |
10PPS 2300Hz No Parity |
3 |
TouchTone, Extended Format |
3 |
10PPS 2300Hz Parity |
4 |
Pulse Dialing, Partial Extended Format |
4 |
20PPS 1400Hz No Parity |
5 |
TouchTone, Partial Extended Format |
5 |
20PPS 1400Hz, Parity |
8 |
No Dialer, Local Only System |
6 |
20PPS 2300Hz No Parity |
|
|
7 |
20PPS 2300Hz Parity |
|
|
8 |
40PPS 1400Hz No Parity |
|
|
A |
40PPS 2300Hz No Parity |
|
|
B |
40PPS 2300Hz Parity
|
L3 |
Message Type |
L4 |
System Options |
0 |
3×1, No Bell Lockout |
0 |
Silent Panic |
2 |
4×1, No Bell Lockout |
1 |
Audible Panic |
6 |
4×2, No Bell Lockout |
2 |
Silent Panic, Split Report |
|
|
3 |
Audible Panic, Split Report |
|
|
4 |
Silent Panic, 24Hr Test Signal |
|
|
5 |
Audible Panic, 24Hr Test Signal |
|
|
6 |
Silent Panic, Split Report, 24Hr Test Signal |
|
|
7 |
Audible Panic, Split Report, 24Hr Test Signal |
|
|
8 |
Silent Panic, Bell Test on Arm |
|
|
9 |
Audible Panic, Bell Test on Arm |
|
|
A |
Silent Panic, Split Report, Bell Test on Arm |
|
|
B |
Audible Panic, Split Report, Bell Test on Arm |
|
|
C |
Silent Panic, 24Hr Test Signal |
|
|
D |
Audible Panic, 24Hr Test Signal, Bell Test on Arm |
|
|
E |
Silent Panic, Plit Report, 24Hr Test Signal, Bell Test |
|
|
F |
Audible Panic, Spit Report, 24Hr Test Signal, Bell Test
|