Communications |
|
|
Question |
Suggest |
Variables |
001 |
Callback Number |
Leave Blank |
Up to 32 digits |
002 |
Dump Telephone Number |
Leave Blank |
Up to 32 digits |
003 |
CS 1 Receiver Telephone Number
SHIFT + 2 (B) = *
SHIFT + 3 (C) = 3 second delay
SHIFT + 4 (D) = #
|
18xxxxxxx |
Up to 32 digits |
|
To erase move cursor to beginning of number by pressing CODE then * 8 |
004 |
CS 1 Receiver Type |
Ademco Point ID |
FBII Super 1400Hz
FBII Super 2300Hz
Ademco Point ID
4/2 Express
BFSK 2300
The rest is all 4/2
|
005 |
CS 1 Acc Size (Account length)
(Press 0 to toggle)
|
4-Digit Account |
3-Digit Account Number
4-Digit Account Number
|
006 |
CS 1 Parity Selection |
No |
Yes = Report Parity Enabled
No = Report Parity Disabled
|
007 |
CS 1 Sescoa Format |
No |
Yes = Sescoa Format Enabled
No = Sescoa Format Disabled
|
008 |
CS 2 Receiver Telephone Number |
18xxxxxxx |
Up to 32 digits |
009 |
CS 2 Receiver Type |
Ademco Point ID |
FBII Super 1400Hz
FBII Super 2300Hz
Ademco Point ID
4/2 Express
BFSK 2300
The rest is all 4/2
|
010 |
CS 2 3/4 Digit Account Select |
4-Digit Account |
3-Digit Account
4-Digit Account
|
011 |
CS 2 Parity Selection |
No |
Yes = Report Parity Enabled
No = Report Parity Disabled
|
012 |
CS 2 Sescoa Format |
No |
Yes = Sescoa Format Enabled
No = Sescoa Format Disabled
|
013 |
Installer Code |
123456 |
Leave alone |
014 |
Dialing Type |
Tone |
Tone
Fast Tone
Pulse
Adaptive (Tone w/Pulse backup)
|
015 |
Dial Tone Detection |
No |
Yes = Wait for dial tone before dialing
No = No wait for dial tone before dialing
|
016 |
CS Dialer Enable |
Yes |
Yes = Communicator Enabled
No = Communicator Disabled
|
017 |
Remote Commands Enable
(Downloader Arm/Disarm etc)
|
Yes |
Yes = Allow Remote Commands
No = No Remote Commands
|
018 |
Remote Disarm Enable |
Yes |
Yes = Remote Disarming Enabled
No = Remote Disarming Disabled
|
019 |
Remote Arming Enable |
Yes |
Yes = Remote Arming Enabled
No = Remote Arming Disabled
|
020 |
Remote Bypass Enable |
Yes |
Yes = Remote Bypassing Enabled
No = Remote Bypassing Disabled
|
021 |
# Attempts (Dialing Attempts) |
08 |
01 to 16 Attempts (08 = Default) |
022 |
# of Rings to Pickup |
08 |
01 to 16 Rings (08 = Default) |
023 |
Extended Antijam |
No |
Yes = 4 Second wait until Dialing
No = 30 Second wait until Dialing
|
024 |
Extended Ack |
No |
Yes = 120 Sec wait for Ack from CS
No = 30 sec wait for Ack from CS
|
|
|
|
User Attributes |
(Pick a user in 025 and program individual attributes) |
|
|
Question |
Suggest |
Suggest |
025 |
Select User Number |
01 to 64, 000 = Skip |
|
026 User Authorization Level |
Level 1 |
(Super User, does almost everything) |
Level 2 |
(Arm/Disarm/Bypass/Program Users, Change Partition) |
Level 3 |
(Arm/Disarm/Bypass/Program Users) |
Level 4 |
(Arm/Disarm/Bypass) |
Level 5 |
(Arm/Disarm) |
Level 6 |
(Duress) |
Level 7 |
(Arm Only, Maid Code) |
|
|
027 User CS ID |
001 to 255 |
(User Number for Open/Closings) |
|
028 User Partition Assignment |
YNNNNNNN |
(Use INSTANT and CODE to move left/right)
(0 toggles Y/N for each of the 8 partitions)
|
|
029 OC Partition Enable |
YYYYYYYY |
(Use INSTANT and CODE to move left/right)
(0 toggles Y/N for each of the 8 partitions)
|
|
030 User Master Partition |
Not Sure |
1 to 8 |
|
|
|
System Attributes |
|
|
Question |
Suggest |
Suggest |
031 |
Zone Expansion Modules
(Zones 9 to 72)
|
No Expand |
NO EXPAND |
(No Expansion Module) |
8 ZONE EXP |
(7105 Zone Expander) |
MUX EXPAND 1 |
(7120/7126 Multiplexer) |
MUX EXPAND 2 |
|
032 |
Xtrig Mode |
No |
(Yes if XL-4705 Relay Module used) |
033 |
Open/Close Report Path |
CS#1 Only |
CS#1 Only
CS#2 Only
CS#1 & CS#2
CS#1 BU CS#2 (CS2 as Backup)
CS#2 BU CS#1 (CS1 as Backup)
None (Reports)
|
034 |
Enable Autoarm |
NNNNNNNN |
(INSTANT/CODE moves Left/Right)
(0 toggles Y/N for each of 8 partitions)
|
035 |
Clock Path |
None |
CS#1 Only
CS#2 Only
CS#1 & CS#2
CS#1 BU CS#2 (CS2 as Backup)
CS#2 BU CS#1 (CS1 as Backup)
None (Reports)
|
036 |
Test CS Path |
None |
037 |
Test Frequency |
Sunday |
12 Hour |
Wednesday |
24 Hour |
Thursday |
Sunday |
Friday |
Monday |
Saturday |
Tuesday |
|
038 |
Test Time Hr |
02 |
00 to 23 Hours |
039 |
Test Time Mn |
00 |
00 to 59 Minutes |
040 |
Down Path
(Download OK signal)
|
None |
CS#1 Only
CS#2 Only
CS#1 & CS#2
CS#1 BU CS#2 (CS2 as Backup)
CS#2 BU CS#1 (CS1 as Backup)
None (Reports)
|
041 |
Bypass Path |
None |
042 |
Dis Byp Stay |
No |
Yes = Bypassed Zns not Transmitted to CS
No = Bypassed Zns Transmitted to CS
|
043 |
Xmit Bypass |
On Bypass |
On Bypass = Sends signal on Bypass
On Arming = Sends signal on Arming
|
044 |
Auto Unby En |
Yes |
Yes = Bypassed Zns unbypass w/Disarm
No = Bypassed Zns Manually Unbypassed
|
045 |
Arm Out Lev |
High |
High = Trigger Voltage High on Arming
Low = Trigger Voltage Low on Arming
|
046 |
Bell Tst Arm |
No |
Yes = Bell Test on Arming
No = No Bell Test on Arming
|
047 |
Bell Rbak |
No |
Yes = Bell Ringback at Closing
No = No Bell Ringback at Closing
|
048 |
Sound Rbak |
Yes |
Yes = Keypad Ringback on all Signals
No = No Keypad Ringback
|
049 |
Fire Verif |
Yes |
Yes = Relay 2 used as Fire Reset
No = Relay 2 not used for Smokes
|
050 |
Enable Reset |
No |
Yes = * Key resets Fire
No = User Code resets Fire
|
051 |
Enable Restore to Follow Loop |
No |
Yes = All Rest Signals follow Loop
No = Restores after Bell Cutoff
|
052 |
Action on Abort |
No Abort |
Abort Code (Sends Abort Code)
Stop Dialing (Kills Communicator)
No Abort
Restore (Transmits Restore Code)
|
053 |
Cross Partition |
Yes |
Yes = # 0 allows User to other Partitions
No = No User access to other Partitions
|
054 |
Enable Quick Arming |
Yes |
Yes = # 1 Quick Arms
No = No Quick Arming allowed
|
055 |
Enable Quick Forced Arming |
Yes |
Yes = # 2 Quick Force Arms
No = No Quick Force Arming Allowed
|
056 |
Secure Forced Arm Enable |
Yes |
Yes = User Code to Force Arm
No = No User Code to Force Arm
|
057 |
Enable Zone Directory |
Yes |
Yes = # 4 can scroll Zone Descriptions
No = No scrolling Zone Descriptions
|
058 |
Quick Bypass |
Yes |
Yes = # 5 Bypassing Enabled
No = Quick Bypassing Disabled
|
059 |
Chime Control |
Yes |
Yes = # 6 Enables Door Chimes
No = Door Chimes not Allowed
|
060 |
Enable Super User (Level 0) |
Yes |
Yes = Level 1 Users alter Partition info
No = No Users can alter Partition info
|
061 |
Multi Partition Arm/Disarm |
Arm/Disarm |
Arm/Disarm = Allows multi Part Arming
Disabled = # 0 is not permitted
|
062 |
User # + Code |
No |
Yes = 7 digit User Codes
No = 4 digit User Codes
|
063 |
CS/Inst Def |
No |
Yes = CSID & Installer Code Lockout
No = Not Locked out
|
064 |
Kpad Prog |
Yes |
Yes = Allow Keypad Programming
No = No Keypad Programming
|
065 |
Daylte Sav |
Yes |
Yes = Switch Time automatically
No = No Daylight Savings
|
066 |
AC Freq |
60 Hz |
50 Hz AC Line Frequency
60 Hz AC Line Frequency
|
|
|
|
System Timing |
|
|
Question |
Suggest |
Suggest |
067 |
Bell Delay 15S |
00 |
00 (No Delay) to 15 x15 Seconds
Before Bell activation from Relay #1
|
068 |
Dialer Delay 15S |
01 |
00 (No Delay) to 15 x15 Seconds
Before Dialer activation
|
069 |
Exit Del 1 15S |
04 (60 seconds) |
00 (None) to 15 x15 Seconds |
070 |
Exit Del 2 15S |
04 (60 seconds) |
00 (None) to 15 x15 Seconds |
071 |
Entry Del 1 15S |
02 (30 seconds) |
00 (None) to 15 x15 Seconds |
072 |
Entry Del 2 15S |
04 (60 seconds) |
00 (None) to 15 x15 Seconds |
073 |
AC Loss 15MN |
04 (60 minutes) |
00 (None) to 15 x15 Minutes |
074 |
Exit Triggers |
NNNNNNNN |
(INSTANT/CODE moves Left/Right)
(0 toggles Y/N for each of 8 Triggers)
|
075 |
Entry Triggers |
NNNNNNNN |
(INSTANT/CODE moves Left/Right)
(0 toggles Y/N for each of 8 Triggers)
|
076 |
Timeout1 1MN (Timeout for Relay 1) |
14 (14 minutes) |
00 (None) to 15 Minutes |
077 |
Timeout2 2MN (Timeout for Relay 2) |
15 (15 minutes) |
00 (None) to 15 Minutes |
078 |
Timeout3 3MN (Timeout for Relay 3) |
03 (3 minutes) |
00 (None) to 15 Minutes |
079 |
Global Bell Lockout |
15 (15 Activations) |
00 to 15 Activations |
080 |
Local Bell Lockout |
15 (15 Activations) |
00 to 15 Activations |
081 |
Global Dialer Lockout |
15 (15 Activations) |
00 to 15 Activations |
082 |
Local Dialer Lockout |
15 (15 Activations) |
00 to 15 Activations |
|
|
|
System Fuction Codes |
|
|
Question |
Suggest |
Suggest |
083 |
En Zone Tamper |
Yes |
Yes = Zone Tamper sends Report
No = Zone Tamper doesn’t send
|
084 |
Bypass Code |
0 |
0 to F, 6 = Default
This report auto sends if Contact ID
|
085 |
Bypass Restore Code |
0 |
0 to F, E = Default
This report auto sends if Contact ID
|
086 |
Abort Code |
D |
0 to F, D = Default
This report auto sends if Contact ID
|
087 |
Open Code |
0 |
0 to F, B = Default
This report auto sends if Contact ID
|
088 |
Close Code |
0 |
0 to F, C = Default
This report auto sends if Contact ID
|
089 |
Clock Code |
0 |
0 to F, 0 = Default
This report auto sends if Contact ID
|
090 |
Cancel Code |
0 |
0 to F, F = Default
This report auto sends if Contact ID
|
091 |
Cancel Path |
CS#1 Only |
CS#1 Only
CS#2 Only
CS#1 & CS#2
CS#1 BU CS#2 (CS2 as Backup)
CS#2 BU CS#1 (CS1 as Backup)
None (No Reports)
|
092 |
CS Test Code |
8 |
0 to F, 8 = Default
This report depends on Location 093
|
093 |
Test ID Code |
253 |
000 to 255, 253 = Default
This report auto sends if Contact ID
|
094 |
AC ID Code |
250 |
000 to 255, 250 = Default
This report auto sends if Contact ID
|
095 |
Low Batt ID |
251 |
000 to 255, 251 = Default
This report auto sends if Contact ID
|
096 |
System Error ID Code |
254 |
000 to 255, 254 = Default
This report auto sends if Contact ID
|
097 |
Download Code (End Download) |
F |
0 to F, F = Default
This report auto sends if Contact ID
|
098 |
Down ID Code |
255 |
000 to 255, 255 = Default
This report auto sends if Contact ID
|
099 |
Buzzer on AC Loss |
Yes |
Yes = Keypad Buzzer on AC Loss
No = No Buzzer on AC Loss
|
100 |
Buzzer on Low Battery |
Yes |
Yes = Keypad Buzzer on Low Battery
No = No Buzzer on Low Battery
|
101 |
Buzzer on System Error |
Yes |
Yes = Keypad Buzzer on System Error
No = No Buzzer on System Error
|
102 |
24 Hour AC Loss |
Yes |
Yes = Buzzer on AC Loss if Armed
No = No Buzzer on AC Loss if Armed
|
103 |
24 Hour Low Battery |
Yes |
Yes = Buzzer on Low Battery if Armed
No = No Buzzer on Low Battery if Armed
|
104 |
24 Hour System Error |
Yes |
Yes = Buzzer on System Error if Armed
No = No Buzzer on System Error if Armed
|
105 |
Trouble Type AC Loss |
1 |
1 to 4, 1 = Default (see loc 129 to 141) |
106 |
Trouble Type Low Battery |
2 |
1 to 4, 2 = Default (see loc 129 to 141) |
107 |
Trouble Type System Error |
4 |
1 to 4, 4 = Default (see loc 129 to 141) |
|
|
|
Alarm Types |
(These are not pre-defined that I know of, you must set them up) |
|
|
Question |
Suggest |
Suggest |
108 |
Select Alarm Type |
01 to 16, 00 = Skips |
|
109 Description |
(enter Delay, Instant, Interior etc here)
INSTANT |
advances within a programming location |
CODE |
moves backwards within a programming location |
* 8 |
erases everything from cursor to end of field |
7 |
scrolls letters for text questions |
|
|
110 CS Code |
? |
0 to F
If contact ID Click Here
|
|
111 CS Restore Code |
0 |
0 to F |
|
112 CS Reporting Path |
CS#1 Only |
CS#1 Only
CS#2 Only
CS#1 & CS#2
CS#1 BU CS#2 (CS2 as Backup)
CS#2 BU CS#1 (CS1 as Backup)
None (No Reports)
|
|
113 Bell Delay |
No |
Yes = Bell Delays per Location 067
No = No Bell Delay
|
|
114 Dialer Delay |
No |
Yes = Dialer Delays per Location 067
No = No Dialer Delay
|
|
115 Buzzer Enabled
(No if Silent Alarms & Holdup)
|
Yes |
Yes = Keypad Buzzer on Alarm
No = No Keypad Buzzer Delay
|
|
116 Display Alarm
(No if Silent Alarms & Holdup)
|
Yes |
Yes = Keypad Display on Alarm
No = No Keypad Display Delay
|
|
117 Timeout Selection |
? |
1 to 3 (see Timeouts in Loc 076 to 078) |
|
118 Alarm Priority |
? |
01 (Highest) to 16 (Lowest)
Example: Fire, Duress = highest (16)
Burg would be next highest 15?
Supervisory orTroubles could be 14?
|
|
119 Momentary Triggers
(Trigger 1 to 8 activated by alarm)
|
NNNNNNNN |
(INSTANT/CODE moves Left/Right)
(0 toggles Y/N for 8 Triggers)
|
|
120 Latched Triggers
(Trigger 1 to 8 Latched alarm)
|
NNNNNNNN |
(INSTANT/CODE moves Left/Right)
(0 toggles Y/N for each of 8 Triggers)
|
|
Triggers 7 and 8 must be N if XL4705 External Relay is NOT used |
|
121 Relay 1 (Bell) Select |
NONE |
NONE (0 toggles selection)
PULSED
LATCHED
|
|
122 Relay 2 Select |
NONE |
|
Questions 123 to 127 only if XL4705 External Relay is used |
|
123 Xtrig 1 ATxx (Relay Address) |
00 |
00 to 40 |
|
124 Xtrig 2 ATxx (Relay Address) |
00 |
00 to 40 |
|
125 Xtrig 3 ATxx (Relay Address) |
00 |
00 to 40 |
|
126 Xtrig 4 ATxx (Relay Address) |
00 |
00 to 40 |
|
127 Mom Trig
(which Trigger 1 to 4 is Momentary)
|
NNNN |
(INSTANT/CODE moves Left/Right)
(0 toggles Y/N for each of 8 Triggers)
|
|
128 24Hr Trigger
(which Trigger 1 to 4 is Maintained)
|
NNNN |
(INSTANT/CODE moves Left/Right)
(0 toggles Y/N for each of 8 Triggers)
|
|
|
|
Trouble Types |
|
|
(Trouble Attributes) |
|
|
Question |
Suggest |
Suggest |
129 |
Select Trouble Type |
01 to 8, 0 = Skips to next Location |
|
130 Description |
(enter Fire Trouble, Zone Trouble etc here)
INSTANT |
advances within a programming location |
CODE |
moves backwards within a programming location |
* 8 |
erases everything from cursor to end of field |
7 |
scrolls letters for text questions |
|
|
131 CS Code Trouble |
? |
0 to F |
|
132 CS Trouble Restore |
? |
0 to F |
|
133 CS Rep (Transmission Path) |
CS#1 Only |
CS#1 Only
CS#2 Only
CS#1 & CS#2
CS#1 BU CS#2 (CS2 as Backup)
CS#2 BU CS#1 (CS1 as Backup)
None (No Reports)
|
|
134 CS Dial Del (Trouble Dialer Delay) |
Yes |
Yes = Dialer Delay per Loc 68
No = No Dialer Delay
|
|
136 Timeout |
? |
1 to 3 (see locations 076 to 078) |
|
137 Priority |
? |
0 (Highest) to F (Lowest) |
|
138 Mom Trg
(1 to 8 is Temp activated by Trbl)
|
NNNNNNNN |
(INSTANT/CODE moves Left/Right)
(0 toggles Y/N for each of 8 Triggers)
|
|
139 Lat Trg
(1 to 8 is activated by Trbl)
|
NNNNNNNN |
(INSTANT/CODE moves Left/Right)
(0 toggles Y/N for each of 8 Triggers)
|
|
140 Relay 1 (Bell) Select |
NONE |
NONE (0 toggles selection)
PULSED
LATCHED
|
|
141 Relay 2 Select |
NONE |
|
|
|
Zone Attributes |
|
|
Question |
Suggest |
Suggest |
142 |
Select Zone |
001 to 008, 000 Skips to next Location
009 to 128 if Zone Expander Used
|
|
143 Zone Type |
? |
Instant (0 toggles options)
Entry/Exit
Interior EE Follower
Interior
Fire – Smoke
Fire – Pull Station
Keyswitch
|
|
144 Description |
(enter Living Room, Den, Hall, Front Door etc here)
INSTANT |
advances within a programming location |
CODE |
moves backwards within a programming location |
* 8 |
erases everything from cursor to end of field |
7 |
scrolls letters for text questions |
|
|
145 CS Report Code (if 4/2 Format) |
000 |
000 to 255 (000 disables) |
|
146 CS PID (if Contact ID Format) |
??? |
001 to 422 |
|
147 Right Loop Zone |
No |
Yes = This is a Multiplex Zone
No = This is not a Multiplex Zone
|
|
148 Enable Bypassing
(Yes if Burg, No if Fire)
|
Yes |
Yes = User can bypass this Zone
No = User cannot bypass this Zone
|
|
149 Auto Bypass
(Arm away and Entry Zone not open)
|
No |
Yes = Auto Bypass Enabled
No = Auto Bypass not Enabled
|
|
150 Arm if Faulted
(Zone must close before E/E Delay)
|
No |
Yes = Arm if Faulted
No = Don’t Arm if Faulted
|
|
151 En Vent
(Auto Bypasses open Zns on Arm)
|
No |
Yes = Arm and Auto Bypass if Faulted
No = Don’t Arm if Faulted
|
|
152 Group Enabled |
No |
Yes = Add to Group for Bypassing etc
No = Don’t add to Group
|
|
153 CS Trouble |
Yes |
Yes = Report Zone Troubles
No = Do not report Zone Troubles
|
|
154 CS Restores (Alarms/Troubles) |
No |
Yes = Report Zone Restores
No = Don’t report Zone Restores
|
|
155 Partition |
? |
1 to 8 (1 if no partitions enabled) |
|
156 Enable 24 Hour Zone |
No |
Yes = Zone is a 24 Hr Zone (Fire/Holdup)
No = Zone is a normal Zone
|
|
157 Enable 24 Hour Trouble |
No |
Yes = 24 Hour Zone Trouble (Fire)
No = Zone is a normal Zone
|
|
158 Alarm Type |
? |
01 to 16 (defined in Loc 108 to 128) |
|
159 Trouble Type |
? |
1 to 8 (defined in loc 129 to 141) |
|
160 Al Open
(No for Smoke Detector)
|
Yes |
Yes = Alarm on Open Circuit
No = No Alarm on Open Circuit
|
|
161 Al Shrt
(Yes for Keyswitch and Smoke Det)
|
Yes |
Yes = Alarm on Short Circuit
No = No Alarm on Short Circuit
|
|
162 Tr Open
(Yes for Smoke Detector)
|
No |
Yes = Trouble on Open Circuit
No = No Trouble on Open Circuit
|
|
163 Tr Short
(No for Smoke Detector)
|
No |
Yes = Trouble on Short Circuit
No = No Trouble on Short Circuit
|
|
164 Exit Delay
(only on E/E and Interior Zones)
|
Delay 1 |
Delay 1 (0 toggles selection)
Delay 2
|
|
165 Entry Delay
(only on E/E and Interior Zones)
|
Delay 1 |
Delay 1 (0 toggles selection)
Delay 2
|
|
166 EN Lock (Swinger Shutdown) |
Yes |
Yes = Lockout (Specified in Loc 79 to 82)
No = No Bell/Dialer Lockout
|
|
167 CS Bypass (Bypass Reporting) |
No |
Yes = Will send Bypass Code to CS
No = Will not send Bypass Code to CS
|
|
168 Trouble Buzzer |
Yes |
Yes = Zone Troubles sound KP Buzzer
No = No KP Buzzer if Zone Trouble
|
|
169 En Chime |
? |
Yes = Enable Chime for this Zone
No = No Chime for this Zone
|
|
170 En 750M (Hardwire Zones only) |
Yes |
Yes = Zone has 750ms Response
No = Zone has 250ms Response
|
|
171 Pulse Count |
15 |
1 to 14 Mins, per activation 15 = Disabled |
|
172 # Pulse |
00 |
00 to 15 activations per period
defined in Location 171
|
|
|
|
Keypad Conditions |
|
|
Question |
Suggest |
Suggest |
173 |
Select Keypad Type |
1 to 4, 0 = Skips |
1 = * + # Alarm
2 = * + 1 Alarm
3 = 3 + # Alarm
4 = Duress Signal
|
|
174 CS Code (4/2 Format only) |
000 |
00 to 255, 000 Disables |
|
175 CS PID (if Contact ID Format) |
??? |
001 to 422 |
|
176 Description |
(enter Fire Trouble, Zone Trouble etc here)
INSTANT |
advances within a programming location |
CODE |
moves backwards within a programming location |
* 8 |
erases everything from cursor to end of field |
7 |
scrolls letters for text questions |
|
|
177 Al TY KP (Alarm Type) |
? |
01 to 16 (specified in Loc 108) |
|
178 CS Rest |
No |
Yes = Sends Restore after Alarm
No = Doesn’t send Restore
|
|
|
|
Partitions |
|
|
Question |
Suggest |
Suggest |
179 |
Select Partition |
1 to 8, 0 = Skips |
|
180 Keypad Partition
Keypads 1 to 8 are LED
Keypads 9 to 16 are LCD
|
NNNNNNNNYNNNNNNN |
(INSTANT/CODE moves Left/Right)
(0 toggles Y/N for each of 8 Triggers)
|
|
181 Description Partition |
(enter Warehouse, Store Room, Apartment etc here)
INSTANT |
advances within a programming location |
CODE |
moves backwards within a programming location |
* 8 |
erases everything from cursor to end of field |
7 |
scrolls letters for text questions |
|
|
182 CS1 Account Number |
???? |
SHIFT 1 = A
SHIFT 2 = B
SHIFT 3 = C
SHIFT 4 = D
SHIFT 5 = E
SHIFT 6 = F
|
|
183 CS2 Account Number |
???? |
|
|
|
Auto Dump |
|
|
(normally leave alone) |
|
|
Question |
Suggest |
Suggest |
184 |
Auto Dump |
None |
None (0 toggles options)
Daily
Weekly
Monthly
|
185 |
Day of Month |
01 |
01 to 31 Days |
186 |
Day of Week |
Sunday |
Sunday
Monday
Tuesday
Wednesday
Thursday
Friday
Saturday
|
187 |
Report Hour |
00 |
00 to 23 |
188 |
Report Minute |
00 |
00 to 59 |
189 |
Dump Max |
99 |
00 to 99 Events |
190 |
Auto Dump Account |
???? |
4-Digit Account Number to Identify |
191 |
Auto Dump Description 1 |
(enter whatever you want etc here)
INSTANT |
advances within a programming location |
CODE |
moves backwards within a programming location |
* 8 |
erases everything from cursor to end of field |
7 |
scrolls letters for text questions |
|
192 |
Auto Dump Description 2 |
193 |
Auto Dump Description 3 |
193 |
Auto Dump Description 4 |