FBI XL20 Basics

Zones 4 Hardwire, up to 8 with Wireless
Fuses 3 Amp for Bell, 1 Amp for Aux
Resistors 2.2K
AC Transformer 16 volt 25VA
Batteries
Main Panel 12 volt rechargeable Gel-Cell inside
Door/Windows 3-Volt Lithium
Motion Sensor 2 3-Volt Lithium
Smoke Detector 2 9-volt Alkalines
Remote Keypads 3-Volt Lithium
Keyfobs 3-Volt Lithium
Remote Panics 9-Volt Lithium
Wireless Yes, uses Ademco Transmitters
Downloadable Yes
Panic Buttons
Police Panic * and #
Fire Panic 7 and 9
Medical Panic 1 and 3
Arming 4-digit code (Ready light MUST be on)
Stay Arming STAY key + 4-digit code
Instant Arm INSTANT key + 4-digit code (Can be used with STAY key)
Disarm 4-digit code
Silence Alarm 4-digit code to turn off siren, and again to stop keypad flashing
Bypass BYPASS + 4-digit code + Zone (1 to 8) (Bypassed Zone will slowly blink)
(to bypass more press BYPASS + zone)
Quick Bypass BYPASS + Zone (1 to 8) (if enabled) (Bypassed Zone will slowly blink)
Quick Exit Press STAY if armed for Exit delay (if enabled)
Reset Smoke Enter 4-digit code or enter 4-digit code + *
(If this does NOT reset smoke detector set for service, smoke is bad)
Door Chimes # 6
Quick Arm # 1 (if enabled)
Quick
Force Arm
# 2 (if enabled)
Alarm Memory There is no Alarm Memory
Set Time
1. Press # 3
2. Enter 2-digit Hours (01 to 23)
3. Enter 2-digit Minutes (00 to 59)
4. Enter 2-digit Month (01 to 12)
5. Enter 2-digit Day (01 to 31)
6. Enter 2-digit Year (00 to 99)
7. Keypad will beep and exit
View Time # 7 (LCD keypads only)
Siren Test There is no Siren Test