FBI XL2 Program

XL4600DL should say XL4600DL on Panel Wiring Diagram
XL-2 has Sticker on curcuit board that says XL-2 or XL-2LT
Enter Program CODE key + * + 4600
Move to location * + 2 digit location
Program location After every digit press # to move to next program location
Example: To program phone number enter 1#8#0#0# etc
Exit Program STAY
Default Panel Short “EEPROM RESET” pins on panel and power up system
Download Info
Hex Program CODE+1 = A, CODE+2 = B, CODE+3 = C, CODE+4 = D, CODE+5 = E, CODE+6 = F
Zone Page 4/2 4*2 Std Click HERE for List of what below programming will report

CLICK ON PROGRAM LOCATIONS TO SHOW ALL POSSIBLE VALUES
*00 Installer Code
I _ 4 _ I _ 8 _ I _ 5 _ I _ 0 _ I
L1 L2 L3 L4
*01 Primary Phone Number
I _   _ I _   _ I _   _ I _   _ I _   _ I _   _ I _   _ I _   _ I _   _ I _   _ I _   _ I _   _ I
L1 L2 L3 L4 L5 L6 L7 L8 L9 L10 L11 L12
B = * C = 3 second pause A = End of Phone Number
*02 Secondary Phone Number
I _ N _ I _ O _ I _ T _ I _   _ I _ U _ I _ S _ I _ E _ I _ D _ I _   _ I _   _ I _   _ I _   _ I
L1 L2 L3 L4 L5 L6 L7 L8 L9 L10 L11 L12
*03 Download Phone Number
I _ N _ I _ O _ I _ T _ I _   _ I _ U _ I _ S _ I _ E _ I _ D _ I _   _ I _   _ I _   _ I _   _ I
L1 L2 L3 L4 L5 L6 L7 L8 L9 L10 L11 L12
*04 Dialer Information
Click to show details >>>>
I _ 1 _ I _ 6 _ I _ 6 _ I _ 1 _ I
L1 L2 L3 L4
*05 Keypad Conditions
Click to show details >>>>
(X = Not Used)
I _ F _ I _ 6 _ I _ 6 _ I _ X _ I
L1 L2 L3 L4
*06 Account 1
I _   _ I _   _ I _   _ I _   _ I
L1 L2 L3 L4
*07 Account 2
(Not programmed)
I _ A _ I _ A _ I _ A _ I _ A _ I
L1 L2 L3 L4
*08 System Timeouts
Click to show details >>>>
I _ 2 _ I _ 4 _ I _ 2 _ I _ F _ I
L1 L2 L3 L4
*09 Zone 1 Programming
Click to show details >>>>
(Sends 31)
I _ ? _ I _ ? _ I _ 3 _ I _ 1 _ I
L1 L2 L3 L4
*10 Zone 2 Programming
Click to show details >>>>
(Sends 32)
I _ ? _ I _ ? _ I _ 3 _ I _ 2 _ I
L1 L2 L3 L4
*11 Zone 3 Programming
Click to show details >>>>
(Sends 33)
I _ ? _ I _ ? _ I _ 3 _ I _ 3 _ I
L1 L2 L3 L4
*12 Zone 4 Programming
Click to show details >>>>
(Sends 34)
I _ ? _ I _ ? _ I _ 3 _ I _ 4 _ I
L1 L2 L3 L4
*13 Zone 5 Programming
Click to show details >>>>
(Sends 35)
I _ ? _ I _ ? _ I _ 3 _ I _ 5 _ I
L1 L2 L3 L4
*14 Zone 6 Programming
Click to show details >>>>
(Sends 36, If Smoke use 9416)
I _ ? _ I _ ? _ I _ 3 _ I _ 6 _ I
L1 L2 L3 L4
*15 Ambush/AC Loss
(Ambush = 22. AC Loss = 79)
I _ 2 _ I _ 2 _ I _ 7 _ I _ 9 _ I
L1 L2 L3 L4
*16 Panic/Low Battery
(Panic = 21. Low Battery = 78)
I _ 2 _ I _ 1 _ I _ 7 _ I _ 8 _ I
L1 L2 L3 L4
*17 Open/Close/Test
(For Open/Close use 5 6 A A)
I _ A _ I _ A _ I _ A _ I _ A _ I
L1 L2 L3 L4
*18 Bypass/Restore/Trbl/Rng Cnt
(Restore sends 9 + Zone)
(Fire Trouble sends 7 + Zone)
I _ A _ I _ 9 _ I _ 7 _ I _ A _ I
L1 L2 L3 L4
*19 Keypad Fire/Medical Panics
(Fire Panic = 23)
(Medical Panic = 26)
I _ 2 _ I _ 3 _ I _ 2 _ I _ 6 _ I
L1 L2 L3 L4

Alpha Keypad Zone Description Programming
*21 Zone 1 Alpha Description Up to 12 Digits
*22 Zone 2 Alpha Description Up to 12 Digits
*23 Zone 3 Alpha Description Up to 12 Digits
*24 Zone 4 Alpha Description Up to 12 Digits
*25 Zone 5 Alpha Description Up to 12 Digits
*26 Zone 6 Alpha Description Up to 12 Digits

0 Inserts Space and moves cursor one space right
CODE Mose cursor left one space
INSTANT Moves cursor right one space
7 Moves up through all characters
*7 Scrolls rapidly up through all characters
9 Moves down through all characters
*9 Scrolls rapidly down through all characters
STAY Moves to next zone description
BYPASS Moves to previous zone description