FBI Star XL4600 Program

Says STAR XL4600 on inside panel cover
Enter Program CODE key + * + 4600
Move to location * + 2 digit location
Program location After every digit press # to move to next program location
Example: To program phone number enter 1#8#0#0# etc
Exit Program STAY
Default Panel Short “EEPROM RESET” pins on panel and power up system
Hex Program CODE+1 = A, CODE+2 = B, CODE+3 = C, CODE+4 = D, CODE+5 = E, CODE+6 = F
Zone Page 4*2 Std Click HERE for List of what below programming will report

CLICK ON PROGRAM LOCATIONS TO SHOW ALL POSSIBLE VALUES
*00 Installer Code
I _4_ I _8_ I _5_ I _0_ I
L1 L2 L3 L4
*01 Primary Phone
I _ _ I _ _ I _ _ I _ _ I _ _ I _ _ I _ _ I _ _ I _ _ I _ _ I _ _ I _ _ I
L1 L2 L3 L4 L5 L6 L7 L8 L9 L10 L11 L12
B = *, C = 3 second pause, A = End of Phone Number
*02 Secondary Phone
I _ N _ I _ O _ I _ T _ I _ _ I _ U _ I _ S _ I _ E _ I _ D _ I _ _ I _ _ I _ _ I _ _ I
L1 L2 L3 L4 L5 L6 L7 L8 L9 L10 L11 L12
*03 Dialer Information – (Click to show details)
I _ 1 _ I _ 6 _ I _ 4 _ I _ 1 _ I
L1 L2 L3 L4
*04 Account 1
I _ _ I _ _ I _ _ I _ _ I
L1 L2 L3 L4
*05 Account 2 – (Not programmed)
I _ A _ I _ A _ I _ A _ I _ A _ I
L1 L2 L3 L4
*06 System Timeouts – (Click to show details)
I _ 2 _ I _ 4 _ I _ 2 _ I _ F _ I
L1 L2 L3 L4
*07 Zone 1 Programming – (Sends 31)
I _ ? _ I _ ? _ I _ 3 _ I _ 1 _ I
L1 L2 L3 L4
*08 Zone 2 Programming – (Sends 32)
I _ ? _ I _ ? _ I _ 3 _ I _ 2 _ I
L1 L2 L3 L4
*09 Zone 3 Programming – (Sends 33)
I _ ? _ I _ ? _ I _ 3 _ I _ 3 _ I
L1 L2 L3 L4
*10 Zone 4 Programming – (Sends 34)
I _ ? _ I _ ? _ I _ 3 _ I _ 4 _ I
L1 L2 L3 L4
*11 Zone 5 Programming
(Sends 35)
I _ ? _ I _ ? _ I _ 3 _ I _ 5 _ I
L1 L2 L3 L4
*12 Zone 6 Programming – (Sends 36, If Smoke use 9416)
I _ ? _ I _ ? _ I _ 3 _ I _ 6 _ I
L1 L2 L3 L4
*13 Ambush/AC Loss – (Ambush = 22. AC Loss = 79)
I _ 2 _ I _ 2 _ I _ 7 _ I _ 9 _ I
L1 L2 L3 L4
*14 Panic/Low Battery – (Panic = 21. Low Battery = 78)
I _ 2 _ I _ 1 _ I _ 7 _ I _ 8 _ I
L1 L2 L3 L4
*15 Open/Close/Test – (For O/Cl use 5 6 A A)
I _ A _ I _ A _ I _ A _ I _ A _ I
L1 L2 L3 L4
*16 Bypass/Restore/Trouble – (Restore sends 9 + Zn, Fire Trouble sends 7 + Zn)
I _ A _ I _ 9 _ I _ 7 _ I _ A _ I
L1 L2 L3 L4