DTI Sears 665 / 670 Basics

System programs with a Napco 410 Chip Programmer
Zones 7 + 1 fire zone
Resistors 4.7k
Fuses 3 Amp
Battery 12 volt rechargeable Gel-Cell inside main panel
Wireless No
Downloadable Not sure
Panic Buttons Police, Fire and Medical
Arm Enter 4-digit code (Must have READY light)
Quick-Arm (If Enabled) Press 0
Instant Arm Not available with this system
Disarm 4 digit code
Silence Alarm 4-digit code
Bypass Press # 1 to display zone status, press zone # to bypass (1 to 8), then press # 0
Alarm Memory Press # 2 to display last alarm, press # 0 to exit
Or Press # 3

Light 1 = Fire Zone Alarm
Light 2 = Duress Code Activated
Light 3 = Fire Panic Activated
Light 4 = Medical Panic Activated
Light 5 = Police Panic Activated
Light 6 = Low Panel Battery
Light 7 = AC Power Loss
Press # 0 to exit
Reset # 8
Door Chimes Not available with this system
Phone Test # 7, TRANSMIT light will turn on, flash if test failed
Sensor Test # 4, alarm will sound briefly if a zone is violated, press # 0 to exit