[01] |
Zone Definitions (Underlined are most common)
Default |
|
|
First Digit |
Second Digit |
00 |
I_ _I_ _I |
Zone 1 |
0 Audible/ Steady |
0 = Delay |
00 |
I_ _I_ _I |
Zone 2 |
1 Silent/Pulsed |
1 = Delay 2 |
00 |
I_ _I_ _I |
Zone 3 |
2 Silent |
2 = Instant |
00 |
I_ _I_ _I |
Zone 4 |
3 = Interior |
00 |
I_ _I_ _I |
Zone 5 |
4 = 24-Hr Zone |
00 |
I_ _I_ _I |
Zone 6 |
5 = 24-hour Buzzer |
00 |
I_ _I_ _I |
Zone 7 |
6 = For Future Use |
00 |
I_ _I_ _I |
Zone 8 |
7 = For Future Use |
00 |
I_ _I_ _I |
Zone 9 |
8 = Keyswitch Arm |
00 |
I_ _I_ _I |
Zone 10 |
9 = Fire |
|
[02] |
System Times |
Default |
030 |
I_ _I_ _I_ _I |
Entry Delay (seconds) |
045 |
I_ _I_ _I_ _I |
Entry Delay 2 (seconds) |
120 |
I_ _I_ _I_ _I |
Exit Delay (seconds) |
004 |
I_ _I_ _I_ _I |
Burglar Alarm Cut-off (minutes) |
004 |
I_ _I_ _I_ _I |
Fire Alarm Cut-off (minutes) |
|
[03] |
Installer Code |
Default |
0900 |
I_0_I_9_I_0_I_0_I (Older boards use 1550, ADT v4.2 is 8999)
|
[04] |
Master Code |
Default |
1234 |
I_?_I_?_I_?_I_?_I
|
[05] |
First System Option |
Default |
|
ON |
OFF |
OFF |
I_OFF_I |
1 Quick Exit Disabled |
Quick Exit Enabled |
OFF |
I_OFF_I |
2 Auto Interior Enabled (stay) |
Auto Interior Disabled |
OFF |
I_OFF_I |
3 Door Chime Option Not Available |
Door Chime Option Available |
OFF |
I_OFF_I |
4 Access Code 9 is One Time Use |
Access Code 9 is Normal Code |
OFF |
I_OFF_I |
5 Sounder Shutdown Enabled |
Sounder Shutdown Disabled |
OFF |
I_OFF_I |
6 Second Sounder for Alarms Only |
Second Sounder Functions Normally |
OFF |
I_OFF_I |
7 Pre-Alert Volume is Medium |
Pre-Alert Volume is Low |
OFF |
I_OFF_I |
8 AC Failure Excluded from Troubles |
AC Failure Included in Troubles
|
[06] |
Second System Options |
Default |
|
ON |
OFF |
OFF |
I_OFF_I |
1 Keypad Fire Key Disabled |
Keypad Fire Key Enabled |
OFF |
I_OFF_I |
2 Keypad Police Key Disabled |
Keypad Police Key Enabled |
OFF |
I_OFF_I |
3 Keypad Medical Key Disabled |
Keypad Medical Key Enabled |
OFF |
I_OFF_I |
4 Keypad Police Panic Audible |
Keypad Police Panic Silent |
OFF |
I_OFF_I |
5 Keypad Fire Steady Alarm |
Keypad Fire Sounds Pulsed Alarm |
OFF |
I_OFF_I |
6 Bypassing Disabled |
Bypassing Enabled |
OFF |
I_OFF_I |
7 Keypad Lockout Enabled |
Keypad Lockout Disabled |
OFF |
I_OFF_I |
8 AC Frequency 50Hz (Europe) |
AC Frequency 60Hz (N. America)
|
[07] |
Third System Options |
Default |
|
ON |
OFF |
OFF |
I_OFF_I |
1 Entry Delay Off Arming |
Entry Delay Off Disabled |
ON |
I_ON_I |
2 Silent Sprvsry Fault/Trbls |
Silent Supervisory Fault Disabled |
OFF |
I_OFF_I |
3 Tampers Transmit Only Armed |
Tampers Always Transmit |
OFF |
I_OFF_I |
4 Interior Zone with Delay |
Interior Zone with Delay Disabled |
OFF |
I_OFF_I |
5 Exit Delay Termination |
Exit Delay Termination Disabled |
OFF |
I_OFF_I |
6 Audible Home Mode Arming |
Audible Home Mode Arming Disabled |
OFF |
I_OFF_I |
7 For Future Use |
OFF |
I_OFF_I |
8 For Future Use
|
[20] |
Receiver Phone 1 (15 Digits Maximum)
I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I
* 2 * = HEX B – to dial *
* 3 * = HEX C – Insert a 4-second pause
* 4 * = HEX D – Wait for Dial-Tone
* 5 * = HEX E – to dial #
* 6 * = Erases Phone Number
|
[21] |
Receiver Phone 2 (15 Digits Maximum)
I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I
|
[22] |
Account Number 1 (Any 0 must be entered as *1* 00 is *11*)
I_ _I_ _I_ _I_ _I
A = * 1 * B = * 2 * C = * 3 * D = * 4 * E = * 5 * F = * 6 *
|
[23] |
Alarm Reporting Codes |
|
I_3_I_1_I |
Zone 1 Alarm |
I_3_I_6_I |
Zone 6 Alarm |
|
I_3_I_2_I |
Zone 2 Alarm |
I_3_I_7_I |
Zone 7 Alarm |
|
I_3_I_3_I |
Zone 3 Alarm |
I_3_I_8_I |
Zone 8 Alarm |
|
I_3_I_4_I |
Zone 4 Alarm |
I_3_I_9_I |
Zone 9 Alarm |
|
I_3_I_5_I |
Zone 5 Alarm |
I_4_I_1_I |
Zone 10 Alarm
|
[24] |
Restoral Reporting Codes |
|
I_0_I_0_I |
Zone 1 Restoral |
I_0_I_0_I |
Zone 6 Restoral |
|
I_0_I_0_I |
Zone 2 Restoral |
I_0_I_0_I |
Zone 7 Restoral |
|
I_0_I_0_I |
Zone 3 Restoral |
I_0_I_0_I |
Zone 8 Restoral |
|
I_0_I_0_I |
Zone 4 Restoral |
I_0_I_0_I |
Zone 9 Restoral |
|
I_0_I_0_I |
Zone 5 Restoral |
I_0_I_0_I |
Zone 10 Restoral
|
[25] |
Closing (Arming) Reporting Codes |
|
I_0_I_0_I |
Access Code 0 |
I_0_I_0_I |
Access Code 5 |
|
I_0_I_0_I |
Access Code 1 |
I_0_I_0_I |
Access Code 6 |
|
I_0_I_0_I |
Access Code 2 |
I_0_I_0_I |
Access Code 7 |
|
I_0_I_0_I |
Access Code 3 |
I_0_I_0_I |
Access Code 8 |
|
I_0_I_0_I |
Access Code 4 |
I_0_I_0_I |
Access Code 9
|
[26] |
Opening (Disarming) Reporting Codes |
|
I_0_I_0_I |
Access Code 0 |
I_0_I_0_I |
Access Code 5 |
|
I_0_I_0_I |
Access Code 1 |
I_0_I_0_I |
Access Code 6 |
|
I_0_I_0_I |
Access Code 2 |
I_0_I_0_I |
Access Code 7 |
|
I_0_I_0_I |
Access Code 3 |
I_0_I_0_I |
Access Code 8 |
|
I_0_I_0_I |
Access Code 4 |
I_2_I_6_I |
Access Code 9 (Hostage)
|
[27] |
Tamper Reporting Codes |
|
I_0_I_0_I |
Zone 1 Tamper |
I_0_I_0_I |
Zone 6 Tamper |
|
I_0_I_0_I |
Zone 2 Tamper |
I_0_I_0_I |
Zone 7 Tamper |
|
I_0_I_0_I |
Zone 3 Tamper |
I_0_I_0_I |
Zone 8 Tamper |
|
I_0_I_0_I |
Zone 4 Tamper |
I_0_I_0_I |
Zone 9 Tamper |
|
I_0_I_0_I |
Zone 5 Tamper |
I_0_I_0_I |
Zone 10 Tamper
|
[28] |
Tamper Restoral Reporting Codes |
|
I_0_I_0_I |
Zone 1 Tamper Restoral |
I_0_I_0_I |
Zone 6 Tamper Restoral |
|
I_0_I_0_I |
Zone 2 Tamper Restoral |
I_0_I_0_I |
Zone 7 Tamper Restoral |
|
I_0_I_0_I |
Zone 3 Tamper Restoral |
I_0_I_0_I |
Zone 8 Tamper Restoral |
|
I_0_I_0_I |
Zone 4 Tamper Restoral |
I_0_I_0_I |
Zone 9 Tamper Restoral |
|
I_0_I_0_I |
Zone 5 Tamper Restoral |
I_0_I_0_I |
Zone 10 Tamper Restoral
|
[29] |
Zone Low Battery Reporting Codes |
|
I_0_I_0_I |
Zone 1 Low Battery |
I_0_I_0_I |
Zone 6 Low Battery |
|
I_0_I_0_I |
Zone 2 Low Battery |
I_0_I_0_I |
Zone 7 Low Battery |
|
I_0_I_0_I |
Zone 3 Low Battery |
I_0_I_0_I |
Zone 8 Low Battery |
|
I_0_I_0_I |
Zone 4 Low Battery |
I_0_I_0_I |
Zone 9 Low Battery |
|
I_0_I_0_I |
Zone 5 Low Battery |
I_0_I_0_I |
Zone 10 Low Battery
|
[30] |
Zone Low Battery Restoral Reporting Codes |
|
I_0_I_0_I |
Zone 1 Low Battery Restoral |
I_0_I_0_I |
Zone 6 Low Battery Restoral |
|
I_0_I_0_I |
Zone 2 Low Battery Restoral |
I_0_I_0_I |
Zone 7 Low Battery Restoral |
|
I_0_I_0_I |
Zone 3 Low Battery Restoral |
I_0_I_0_I |
Zone 8 Low Battery Restoral |
|
I_0_I_0_I |
Zone 4 Low Battery Restoral |
I_0_I_0_I |
Zone 9 Low Battery Restoral |
|
I_0_I_0_I |
Zone 5 Low Battery Restoral |
I_0_I_0_I |
Zone 10 Low Battery Restoral
|
[31] |
Zone Supervisory Reporting Codes |
|
I_0_I_0_I |
Zone 1 Supervisory |
I_0_I_0_I |
Zone 6 Supervisory |
|
I_0_I_0_I |
Zone 2 Supervisory |
I_0_I_0_I |
Zone 7 Supervisory |
|
I_0_I_0_I |
Zone 3 Supervisory |
I_0_I_0_I |
Zone 8 Supervisory |
|
I_0_I_0_I |
Zone 4 Supervisory |
I_0_I_0_I |
Zone 9 Supervisory |
|
I_0_I_0_I |
Zone 5 Supervisory |
I_0_I_0_I |
Zone 10 Supervisory
|
[32] |
Zone Supervisory Restoral Reporting Codes |
|
I_0_I_0_I |
Zone 1 Supervisory Restoral |
I_0_I_0_I |
Zone 6 Supervisory Restoral |
|
I_0_I_0_I |
Zone 2 Supervisory Restoral |
I_0_I_0_I |
Zone 7 Supervisory Restoral |
|
I_0_I_0_I |
Zone 3 Supervisory Restoral |
I_0_I_0_I |
Zone 8 Supervisory Restoral |
|
I_0_I_0_I |
Zone 4 Supervisory Restoral |
I_0_I_0_I |
Zone 9 Supervisory Restoral |
|
I_0_I_0_I |
Zone 5 Supervisory Restoral |
I_0_I_0_I |
Zone 10 Supervisory Restoral
|
[33] |
Priority Alarms and Restorals Reporting Codes |
|
I_1_I_9_I |
Keypad Fire Panic Alarm |
I_0_I_0_I |
Keypad Fire Panic Restoral |
|
I_4_I_9_I |
Keypad Medical Panic Alarm |
I_0_I_0_I |
Keypad Medical Panic Restoral |
|
I_2_I_9_I |
Keypad Police Panic Alarm |
I_0_I_0_I |
Keypad Police Panic Restoral |
|
I_7_I_6_I |
Fire Zone Trouble |
I_0_I_0_I |
Fire Zone Trouble Restoral
|
[34] |
System Trouble Reporting Codes |
|
I_7_I_9_I |
Controller AC Fail Trouble |
I_7_I_9_I |
Sounder 2 AC Fail Trouble |
|
I_7_I_8_I |
Controller Low Bat Trouble |
I_7_I_8_I |
Sounder 2 Low Bat Trouble |
|
I_7_I_9_I |
Sounder 1 AC Fail Trouble |
I_7_I_8_I |
Keypad 1 Low Bat Trouble |
|
I_7_I_8_I |
Sounder 1 Low Bat Trouble |
I_7_I_8_I |
Keypad 2 Low Bat Trouble
|
[35] |
System Trouble Restoral Reporting Codes |
|
I_0_I_0_I |
Controller AC Fail Restoral |
I_0_I_0_I |
Sounder 2 AC Fail Restoral |
|
I_0_I_0_I |
Controller Low Bat Restoral |
I_0_I_0_I |
Sounder 2 Low Bat Restoral |
|
I_0_I_0_I |
Sounder 1 AC Fail Restoral |
I_0_I_0_I |
Keypad 1 Low Bat Restoral |
|
I_0_I_0_I |
Sounder 1 Low Bat Restoral |
I_0_I_0_I |
Keypad 2 Low Bat Restoral
|
[36] |
Keypad and Sounder Tamper Reporting Codes |
|
I_0_I_0_I |
Sounder 1 Tamper |
I_0_I_0_I |
Keypad 1 Tamper |
|
I_0_I_0_I |
Sounder 2 Tamper |
I_0_I_0_I |
Keypad 2 Tamper |
|
I_0_I_0_I |
Sounder 1 Supervisory |
I_0_I_0_I |
Keypad 1 Supervisory |
|
I_0_I_0_I |
Sounder 2 Supervisory |
I_0_I_0_I |
Keypad 2 Supervisory
|
[37] |
Keypad and Sounder Restoral Reporting Codes |
|
I_0_I_0_I |
Sounder 1 Tamper Restoral |
I_0_I_0_I |
Keypad 1 Tamper Restoral |
|
I_0_I_0_I |
Sounder 2 Tamper Restoral |
I_0_I_0_I |
Keypad 2 Tamper Restoral |
|
I_0_I_0_I |
Sounder 1 Superv Restoral |
I_0_I_0_I |
Keypad 1 Superv Restoral |
|
I_0_I_0_I |
Sounder 2 Superv Restoral |
I_0_I_0_I |
Keypad 2 Superv Restoral
|
[38] |
Additional Reporting Codes |
|
I_0_I_0_I |
Failure to Communicate |
I_0_I_0_I |
Downloading Lead-In Code |
|
I_0_I_0_I |
RF Jam Detect |
I_0_I_0_I |
Downloading Lead-Out Code |
|
I_E_I_E_I |
Periodic Test |
I_0_I_0_I |
Partial Closing Code |
|
I_0_I_0_I |
Installer Lead-In Code |
I_D_I_1_I |
Opening After Alarm |
|
I_0_I_0_I |
Installer Lead-Out Code |
I_0_I_0_I |
Telephone Line Monitor Restoral
|
|
[39] |
Communication Variables
Default |
003 |
I_ _I_ _I_ _I |
Swinger Shutdown Counter |
000 |
I_ _I_ _I_ _I |
Transmission Delay before Dial |
(001-255 seconds) |
030 |
I_ _I_ _I_ _I |
AC Failure Communication Delay |
(001-255 minutes) |
030 |
I_ _I_ _I_ _I |
Test Transmission Cycle |
(001-255 days) |
030 |
I_ _I_ _I_ _I |
Fire Safety Transmission Delay |
(001 – 255 seconds) |
007 |
I_ _I_ _I_ _I |
Zone Low Battery Transmission |
(001 – 255 days) |
|
[40] |
Test Transmission Time Of Day (1st 2 digits Hours, 2nd 2 digits Minutes) |
Default |
0100 |
I_0_I_0_I_0_I_0_I
|
[41] |
Communication Format (Any Underlined format will work) |
Default |
01 |
I_0_I_1_I
[00] Silent Knight/Ademco Slow 10 BPS (1400 Hz handshake) 3/1, 4/1, 4/2 non-extended
[01] Sescoa/Franklin/DCI/Vertex 20 BPS (2300 Hz handshake) 3/1, 4/1 and 4/2 non-extended
[02] Sescoa/Franklin/DCI/Vertex 20 BPS, 1400 Hz Handshake
[03] Radionics 40 BPS 1400 Hz Handshake
[04] Radionics 40 BPS Parity 2300 Hz Handshake
[05] Radionics 40 BPS with Parity, 2300 Hz Handshake
[06] Radionics 40 BPS with Parity, 2300 Hz Handshake
|
[42] |
First Communicator Options |
Default |
|
ON |
OFF |
OFF |
I_OFF_I |
1 Communicator Disabled |
Communicator Enabled |
OFF |
I_OFF_I |
2 Pulse Dialing |
DTMF Dialing |
OFF |
I_OFF_I |
3 Pulse Dial 67/33 Ratio |
Pulse Dial 60/40 Ratio |
OFF |
I_OFF_I |
4 xmissions to 24 Hr Period |
Transmissions Limited to Armed Period |
OFF |
I_OFF_I |
5 TLM Disabled |
TLM Enabled |
OFF |
I_OFF_I |
6 TLM Silent when Armed |
TLM Alarm Audible when Armed |
OFF |
I_OFF_I |
7 For Future Use |
OFF |
I_OFF_I |
8 For Future Use
|
[43] |
Second Communicator Options |
Default |
|
ON |
OFF |
ON |
I_ON_I |
1 Restorals Follow Zone Enabled |
Restorals Follow Zone Disabled |
OFF |
I_OFF_I |
2 Restore on Sounder Timeout |
Restorals on Sounder Timeout Disabled |
OFF |
I_OFF_I |
3 Restorals on Disarming Enabled |
Restoral on Disarming Disabled |
OFF |
I_OFF_I |
4 For Future Use |
OFF |
I_OFF_I |
5 For Future Use |
OFF |
I_OFF_I |
6 For Future Use
|
[70] |
Downloading Option Code (Toggle Options ON/OFF, Press # to Exit) |
Default |
|
ON |
OFF |
OFF |
I_ON_I |
1 Ring Detect Enabled |
Download Disabled |
ON |
I_ON_I |
2 Answer Machine Override |
Disabled |
OFF |
I_OFF_I |
3 Callback Enabled |
Callback Disabled |
OFF |
I_OFF_I |
4 User Initiated Call-Up |
Disabled |
OFF |
I_OFF_I |
5 Periodic Downloading |
Disabled |
OFF |
I_OFF_I |
6 For Future Use |
OFF |
I_OFF_I |
7 For Future Use |
OFF |
I_OFF_I |
8 For Future Use
|
[71] |
Downloading Computer’s Telephone Number
I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I
|
[72] |
Downloading Access Code |
Default |
9090 |
I_9_I_0_I_9_I_0_I
|
[73] |
Panel Identification Code |
Default |
0909 |
I_0_I_9_I_0_I_9_I
|
[74] |
Number of Rings before Answering |
Default |
012 |
I_0_I_1_I_2_I (Valid entries are 001-255 seconds)
|
[75] |
Installer Initiated Downloading (No Value Required) |
[80] |
Installer Buzzer Walk Test |
[81] |
Module Placement Test |
[82] |
Sounder Test |
[83] |
Manual Dialer Test |
[90] |
Installer Lockout Enable |
[91] |
Installer Lockout Disable |