DSC WLS900 Basics

Zones 10 Wireless zones
Batteries
Main Panel Module 6 volt 1.2 Amp mini Gel Cel
Keypad 4 AA Alkalines
Siren Modules 4 AA Alkalines
Door/Windows 3 to 4 AAA Alkalines
Motion Sensor 4 AAA Alkalines
Smoke Detector 6 AA Alkalines
4-button Keyfob Button type batteries (LR44)
Pendant Panic Non-Replaceable
Downloadable Yes
Panic Buttons Police, Fire and Medical
(Keypad is usually in sleep mode, press # to wake up)
“System
Not Ready”
1. Press ↑ key if Displayed “View Open Zones Y/N?”
2. Press ↑ again to scroll “View Open Zones Y/N?”
3. If finished press ↓ key “Bypass/Unbypass Zones Y/N?”
4. Press ↑ to Bypass or ↓ to exit
Arm Away 1. Enter 4-Digit User Code “Arm System in Away Mode Y/N?”
2. Press ↑ key for Yes “System Armed Exit Delay On”
Arm Home 1. Enter 4-Digit User Code “Arm System in Away Mode Y/N?”
2. Press ↓ key for No “Arm System in Stay Mode Y/N?”
3. Press ↑ key for Yes “System Armed Exit Delay On”
Arm Instant 1. Enter 4-Digit User Code “Arm System in Away Mode Y/N?”
2. Press ↓ key for No “Arm System in Stay Mode Y/N?”
3. Press ↑ key for Yes “Arm with Entry Delay Y/N?”
4. Press ↑ key for Yes “System Armed Exit Delay On”
Disarm Away Enter 4-digit User Code (Press # if any mistake is made)
Disarm Home 1. Enter 4-digit User Code “Disarm System Y/N?”
2. Press ↑ key for Yes “System Disarmed No Alarm Memory”
Silence Alarm Enter 4-digit User Code
Quick Exit
If Home Armed
1. Enter 4-digit User Code “Disarm System Y/N?”
2. Press ↓ key for No “Arm Quick Exit from System Y/N?”
3. Press ↑ key for Yes (You have 2 minutes to exit)
Bypass Zones 1. Enter Master Code
2. Press ↓ to scroll to “Bypass/Unbypass Zones Y/N?”
3. ↑ for Yes or ↓ for No (If ↓ for No display moves to next Zone)
4. If ↑ for Yes display shows “Unbypass Zone Y/N?”
5. Press ↓ for No then # to Exit
Door Chimes 1. Enter Master Code
2. Press ↓ to scroll to “Turn Door Chime On Y/N?”
3. Press ↑ for Yes “Door Chime Has Been Turned On”
4. Press # to exit (Repeat steps to turn Chimes Off)
Alarm Memory 1. Disarm with 4-Digit Code “System Disarmed Alarm in Memory”
2. Wait a few seconds “View Alarm Memory Y/N?”
3. Press ↑ key for Yes “Zone XX Continue Y/N?”
4. Press ↑ for for Next or # to Exit
Sensor Test None, Arm system then trip sensors
(Wireless motions require no movement for 4 minutes prior to testing)
Set Clock 1. Enter Master Code
2. Press ↓ to scroll to “Reset Clock Y/N”
3. Press ↑ and enter Month/Day/Year (July 2 2000 would be 070200)
4. Enter Time in Hours/Minutes (1:30PM would be 1300)
5. Display again shows “Reset Clock Y/N”
6. Press ↓ or # to exit