DSC SCW 9045 / 9047 Trouble
View Trouble | Press * 2, Zone light will turn on showing trouble, press # to exit | |
Service Required | (Press 1 to see exact trouble) | |
Loss of AC Power | (Check transformer) | |
Telephone Line Fault | (Phone line disconnected) | |
Failure to Communicate | (Signal did not go thru) | |
Sensor Fault | (Press 5 to display zone) | |
Sensor Tamper | (Press 6 to display zone) | |
Sensor Low Battery | (Press 7 to display zone, press 7 again to display keyfobs) | |
Loss of Time & Date | (Reprogram time with * 6 + Master Code + 1 + Time + Date) |