DSC PC 5020 / Power864 Program

Report Format SIA, Contact ID, 4/2, 3/1, SIA preferred
Enter Program * 8 5010 (PROGRAM or SYSTEM light should flash, if long beep Code incorrect)
Exit Program #
Move to location Enter 3-digit location, some areas may require # to exit
Default Panel 1. Power down then up, if board clicks panel is locked out (replace board)
2. If no clicks jumper from Zone 1 to PGM1, power up, wait 10 seconds
Enable Download * + 6 + Master Code + 5 (Enables for 6 hours)
(System also enables downloading for 1 hour if powered down then up)
Hex Program A = * 1 * B = * 2 * C = * 3 * D = * 4 * E = * 5 * F = * 6 *

[000] Keypad Assignment (must be done at each keypad)
[0] Slot (Valid entries 0 (Global) or 1 to 2 for Partition 1 to 8 and 1 to 8 for Slot)
[1] Function Key 1 Assignment (Default = 03)
[2] Function Key 2 Assignment (Default = 04)
[3] Function Key 3 Assignment (Default = 06)
[4] Function Key 4 Assignment (Default = 14)
[5] Function Key 5 Assignment (Default = 16)
00 Null Key (Not Used)   11 * 5 User Programming 22 Active Camera Monitor Selection
01 Select Partition 1 12 * 6 User Functions 23 Bypass Recall
02 Select Partition 2 13 * 7 1 Command Output #1 24 Recall Bypass Group
03 Stay Arm 14 * 7 2 Command Output #2 25 For future use
04 Away Arm 15 General Voice Prompt Help 26 For future use
05 * 9 No-Entry Arm (Voice prompts require ESCORT)   27 Select Partition 3
06 * 4 Chime On/Off 16 * 0 Quick Exit 28 Select Partition 4
07 * 6 4 System Test 17 * 1 Reactivate Stay/Away’s 29 Select Partition 5
08 * 1 Bypass Mode 18 Identified Voice Prompt Help 30 Select Partition 6
09 * 2 Trouble Display 19 * 7 3 Command Output #3 31 Select Partition 7
09 * 2 Trouble Display 20 For future use 32 Select Partition 8
10 * 3 Alarm Memory 21 * 7 4 Command Output #4
If multiple LCD keypads one must be set to slot 8 to program Zone description by downloading

[001] Zone 1-8 Definitions
Default Default
01 I_ _I_ _I Zone 01 00 I_ _I_ _I        Zone 09
03 I_ _I_ _I Zone 02 00 I_ _I_ _I Zone 10
03 I_ _I_ _I Zone 03 00 I_ _I_ _I Zone 11
03 I_ _I_ _I Zone 04 00 I_ _I_ _I Zone 12
04 I_ _I_ _I Zone 05 00 I_ _I_ _I Zone 13
04 I_ _I_ _I Zone 06 00 I_ _I_ _I Zone 14
04 I_ _I_ _I Zone 07 00 I_ _I_ _I Zone 15
04 I_ _I_ _I Zone 08 00 I_ _I_ _I Zone 16
00 = Null Zone 11 = 24 Hr Burglary 22 = Momentary Keyswitch Arm
01 = Delay 1 12 = 24 Hr Holdup 23 = Maintained Keyswitch Arm
02 = Delay 2 13 = 24 Hr Gas 24 = Links Answer
03 = Instant 14 = 24 Hr Heat 25 = Links Answer
04 = Interior 15 = 24 Hr Medical 26 = 24 Hr Non-alarm
05 = Interior Stay/Away 16 = 24 Hr Panic 27 = Delayed 24 Hr Waterflow
06 = Delay Stay/Away 17 = 24 Hr Emergency 28 = Instant 24 Hr Waterflow
07 = Delay 24hr Fire 18 = 24 Hr Sprinkler 29 = Auto Verified Fire Zone
08 = Standard 24hr Fire 19 = 24 Hr Water 30 = Fire Supervisory Zone
09 = 24 Hr Supervisory (Links) 20 = 24 Hr Freeze 31 = Day Zone
10 = 24 Hr Supervisory Buzzer 21 = 24 Hr Latching Tamper 87 = Delayed 24 Hr Fire (Wireless)
88 = Standard 24 Hr Fire (Wireless)
[002] Zone 17-32 Definitions
Default Default
00 I_ _I_ _I Zone 17 00 I_ _I_ _I Zone 25
00 I_ _I_ _I Zone 18 00 I_ _I_ _I Zone 26
00 I_ _I_ _I Zone 19 00 I_ _I_ _I Zone 27
00 I_ _I_ _I Zone 20 00 I_ _I_ _I Zone 28
00 I_ _I_ _I Zone 21 00 I_ _I_ _I Zone 29
00 I_ _I_ _I Zone 22 00 I_ _I_ _I Zone 30
00 I_ _I_ _I Zone 23 00 I_ _I_ _I Zone 31
00 I_ _I_ _I Zone 24 00 I_ _I_ _I Zone 32

[003] Zone 33-48 Definitions
Default Default
00 I_ _I_ _I Zone 33 00 I_ _I_ _I Zone 41
00 I_ _I_ _I Zone 34 00 I_ _I_ _I Zone 42
00 I_ _I_ _I Zone 35 00 I_ _I_ _I Zone 43
00 I_ _I_ _I Zone 36 00 I_ _I_ _I Zone 44
00 I_ _I_ _I Zone 37 00 I_ _I_ _I Zone 45
00 I_ _I_ _I Zone 38 00 I_ _I_ _I Zone 46
00 I_ _I_ _I Zone 39 00 I_ _I_ _I Zone 47
00 I_ _I_ _I Zone 40 00 I_ _I_ _I Zone 48

[004] Zone 49-64 Definitions
Default Default
00 I_ _I_ _I Zone 49 00 I_ _I_ _I Zone 57
00 I_ _I_ _I Zone 50 00 I_ _I_ _I Zone 58
00 I_ _I_ _I Zone 51 00 I_ _I_ _I Zone 59
00 I_ _I_ _I Zone 52 00 I_ _I_ _I Zone 60
00 I_ _I_ _I Zone 53 00 I_ _I_ _I Zone 61
00 I_ _I_ _I Zone 54 00 I_ _I_ _I Zone 62
00 I_ _I_ _I Zone 55 00 I_ _I_ _I Zone 63
00 I_ _I_ _I Zone 56 00 I_ _I_ _I Zone 64

[005] Partition System Times
Default
030 I_ _I_ _I_ _I Entry Delay 1 [000-255 seconds]
045 I_ _I_ _I_ _I Entry Delay 2 [000-255 seconds]
120 I_ _I_ _I_ _I Exit Delay [000-255 seconds]
006 I_ _I_ _I_ _I Bell Cut-off [000-255 minutes]
[006] Installer’s Code
Default
5555 I_ _I_ _I_ _I_ _I

[007] Master Code
Default
1234 I_ _I_ _I_ _I_ _I

[008] Maintenance Code
Default
AAAA I_ _I_ _I_ _I_ _I

[009] PCS5020 PGM Output Programming (PGM 1 & 2)
Default
19 I_ _I_ _I PGM 01
10 I_ _I_ _I PGM 02
Programmable Output Options

00 = Not Used 14 = Ground Start Pulse
01 = Burg/Fire Bell Output 15 = Remote Operation
02 = For Future Use 16 = Links 1000 Support
03 = Sensor Reset (4-wire Smokes *72) 17 = Away Armed Status
04 = 2-wire Smoke Support (PGM2 only) 18 = Stay Armed Status
05 = System Armed Status 19 = Command Output 1 *71
06 = Ready To Arm 20 = Command Output 2 *72
07 = Keypad Buzzer Follow Mode 21 = Command Output 3 *73
08 = Courtesy Pulse (Entry/Exit time + 2 minutes) 22 = Command Output 4 *74
09 = System Trouble Output 23 = 24 Hr Silent Input
10 = Latched System Event/Strobe 24 = 24 Hr Audible Input
11 = System Tamper 25 = Delayed Fire and Burg Output
12 = TLM and Alarm
13 = Kissoff Output
[010] PC5020 / PC5208 PGM Output Programming (PGM 3-10)
Default Default
01 I_ _I_ _I PGM 03 (PC5020/PC5208) 01 I_ _I_ _I PGM 07 (PC5208)
01 I_ _I_ _I PGM 04 (PC5020/PC5208) 01 I_ _I_ _I PGM 08 (PC5208)
01 I_ _I_ _I PGM 05 (PC5208) 01 I_ _I_ _I PGM 09 (PC5208)
01 I_ _I_ _I PGM 06 (PC5208) 01 I_ _I_ _I PGM 10 (PC5208)

[011] PCS5204 PGM Output Programming (PGM 11-14)
Default Default
01 I_ _I_ _I PGM 11 01 I_ _I_ _I PGM 13
01 I_ _I_ _I PGM 12 01 I_ _I_ _I PGM 14

[012] Keypad Lockout Options
Default
000 I_0_I_0_I_0_I   Number of Invalid Codes Before Lockout
000 I_0_I_0_I_0_I Lockout Duration (in minutes)

[013] First System Option Code
Default Option ON OFF
OFF I_OFF_I 1 Normally Closed Loops End-of-Line Resistors
OFF I_OFF_I 2 Double End-of-Line Resistors Single End-of-Line Resistors
ON I_ON_I 3 Panels shows Trbl when Armed Panel shows Fire Trouble only when Armed
OFF I_OFF_I 4 Tamper/Fault don’t show open Tampers/Fault show open
OFF I_OFF_I 5 For Future Use
ON I_ON_I 6 Audible Exit Fault Enabled Audible Exit Fault Disabled
ON I_ON_I 7 Event Buffer follows Swinger Event Buf Logs Events Past swinger
OFF I_OFF_I 8 Temporal Three Fire Signal Standard Pulsed Fire

[014] Second System Option Code
Default Option ON OFF
OFF I_OFF_I 1 Arm/Disarm Bell Squawk Arm/Disarm Bell Squawk disable
OFF I_OFF_I 2 Bell Squawk During Auto Arm No Bell Squawk
ON I_OFF_I 3 Bell Squawk On Exit Delay No Bell Squawk
OFF I_OFF_I 4 Bell Squawk On Entry Delay No Bell Squawk
OFF I_OFF_I 5 Bell Squawk On Trouble No Bell Squawk
ON I_ON_I 6 Audible Exit Beeps Silent Exit Delay
OFF I_OFF_I 7 Exit Delay Termination Exit Del. Termination Disabled
OFF I_OFF_I 8 Fire Bell is Continuous Fire Bell follows Bell Cut-Off

[015] Third System Option Code
Default Option ON OFF
ON I_ON_I 1 [F] Keys Enabled Fire Keys Disabled
OFF I_ON_I 2 Panic Keys Audible Panic Keys Silent
OFF I_ON_I 3 Quick Exit Enabled Quick Exit Disabled
ON I_ON_I 4 Quick Arming Enabled
Func Keys do not require Code
Function Keys Disabled
Function Keys require Code
OFF I_OFF_I 5 Code to Bypass Code not Required
OFF I_OFF_I 6 Master Code Not Changable Master Code Changable
ON I_ON_I 7 TLM Enabled (Phone Monitor) TLM Disabled
OFF I_OFF_I 8 TLM Audible When Armed TLM Trouble Only W/Armed

[016] Fourth System Option Code
Default Option ON OFF
ON I_ON_I 1 AC Trouble Displayed AC Trouble not Displayed
OFF I_OFF_I 2 Trouble Flashes if AC Fails Trouble doesn’t follow AC
ON I_OFF_I 3 Blank KP When Not Used Keypad always Active
OFF I_OFF_I 4 Code Req. to Stop KP Blanking No Code Required
OFF I_ON_I 5 Keypad Backlight Enabled Keypad Backlighting Disabled
OFF I_OFF_I 6 Power Save Mode Enabled Power Save Mode Disabled
OFF I_OFF_I 7 Bypass Shows while Armed Bypass doesn’t show/Armed
OFF I_OFF_I 8 Keypad Tampers enabled Keypad Tampers disabled

[017] Fifth System Option Code
Default Option ON OFF
ON I_ON_I 1 WLS Keyfob does not use Code WLS Keyfob uses Code
ON I_ON_I 2 Auto Arm chedule in *6 In Installer Programming Only
ON I_ON_I 3 Audible RF Jam Trouble Beeps Silent RF Trouble Jam Beeps
ON I_ON_I 4 Double Hit Enabled Disabled
OFF I_OFF_I 5 Late to Close Enabled Disabled
OFF I_OFF_I 6 Daylight Savings Time Enabled Disabled
ON I_ON_I 7 Periodic Camera Test Enabled Disabled
OFF I_OFF_I 8 Squawk on Away O/C only Bell Squawk on all Arm/Disarms

[018] Sixth System Option Code (Version 2.3 Only)
Default Option ON OFF
OFF I_OFF_I 1 Test Transmission Exception Enabled Test Transmission Exception Disabled
OFF I_OFF_I 2 Verbal Chime is Enabled Verbal Chime is Disabled
OFF I_OFF_I 3 Verbal Alarm is Enabled Verbal Alarm is Disabled
OFF I_OFF_I 4 Water-Flow Silence Inhibit Water-Flow Silence Inhibit Disabled
OFF I_OFF_I 5 Keypad Buzzer Follows Bell Keypad Buzzer Follows Bell Disabled
ON I_ON_I 6 Cross Zoning is Enabled Police Code is Enabled
OFF I_OFF_I 7 Exit Delay Restart Enabled Exit Delay Restart Disabled
OFF I_OFF_I 8 For Future Use

[020] Keypad Zone Assignments (If using Z type keypads)
Default
00 I_ _I_ _I Keypad (Slot 1) Zone Valid entries are 01-64
00 I_ _I_ _I Keypad (Slot 2) Zone
00 I_ _I_ _I Keypad (Slot 3) Zone First assign keypad slot in 000 section 0 (11 to 18)
00 I_ _I_ _I Keypad (Slot 4) Zone (Keypad added as 11 would be Slot 1 here, 18 is Slot 8)
00 I_ _I_ _I Keypad (Slot 5) Zone then add Zone number here in proper slot
00 I_ _I_ _I Keypad (Slot 6) Zone (Ex: Zone 07 to Keypad 12 enter 00 07 00 00 00 00 00 00)
00 I_ _I_ _I Keypad (Slot 7) Zone (Keypad zones over-ride regular hardwire zones)
00 I_ _I_ _I Keypad (Slot 8) Zone Click HERE for Keypad Zone Wiring

[030] Zone Loop Response
Default Option ON OFF
ON I_ON_I 1 Zone 1 is Fast Loop Zone 1 is Normal Loop Response
ON I_ON_I 2 Zone 2 is Fast Loop Zone 2 is Normal Loop Response
ON I_ON_I 3 Zone 3 is Fast Loop Zone 3 is Normal Loop Response
ON I_ON_I 4 Zone 4 is Fast Loop Zone 4 is Normal Loop Response
ON I_ON_I 5 Zone 5 is Fast Loop Zone 5 is Normal Loop Response
ON I_ON_I 6 Zone 6 is Fast Loop Zone 6 is Normal Loop Response
ON I_ON_I 7 Zone 7 is Fast Loop Zone 7 is Normal Loop Response
ON I_ON_I 8 Zone 8 is Fast Loop Zone 8 is Normal Loop Response

Zone Attributes
Opt 1 Opt 2 Opt 3 Opt 4 Opt 5 Opt 6 Opt 7 Opt 8 Opt 9
ON  Audible   Steady   Chime   Bypass   Force   Swinger   Tx Delay   Wireless   Cross Zone 
OFF Silent Pulsed No No No No No No No
[101] Zone 1 I_ _I I_ _I I_ _I I_ _I I_ _I I_ _I I_ _I I_ _I I_ _I
all the way to
[164] Zone 64 I_ _I I_ _I I_ _I I_ _I I_ _I I_ _I I_ _I I_ _I I_ _I
* Option 8 enables wireless in PC5010 v1.2, Future use with v1 and 1.1 systems

[160] Maximum Dialing Attempts to Each Phone Number
Default
008 I_ _I_ _I_ _I Valid entries are 001-255 attempts (Do not enter 000)

[161] Post Dial Wait for Handshake
Default
040 I_ _I_ _I_ _I Valid entries are 001-255 seconds

[164] PGM Output Timer
Default
005 I_ _I_ _I_ _I Valid entries are 001-255 seconds

[170] Auto ARm Postpone Timer
Default
000 I_ _I_ _I_ _I Valid entries are 001-255 minutes, 000 disables

[176] Burglary Verified Timer (Cross Zone timer)
Default
000 I_ _I_ _I_ _I Valid entries are 001-255 minutes

[177] Waterflow Delay Timer
Default
000 I_ _I_ _I_ _I Valid entries are 001-255 seconds

[178] Alarm time Period for Verbal Alarm
Default
015 I_ _I_ _I_ _I Valid entries are 001-255 seconds

Auto-Arm Schedule (Valid entries are 0000-2359 Default: 9999)
[181] Partition 1 Arm Shedule     [185] Partition 5 Arm Shedule
Sunday I_ _I_ _I_ _I_ _I_ _I Sunday I_ _I_ _I_ _I_ _I_ _I
Monday I_ _I_ _I_ _I_ _I_ _I Monday I_ _I_ _I_ _I_ _I_ _I
Tuesday I_ _I_ _I_ _I_ _I_ _I Tuesday I_ _I_ _I_ _I_ _I_ _I
Wednesday I_ _I_ _I_ _I_ _I_ _I Wednesday I_ _I_ _I_ _I_ _I_ _I
Thursday I_ _I_ _I_ _I_ _I_ _I Thursday I_ _I_ _I_ _I_ _I_ _I
Friday I_ _I_ _I_ _I_ _I_ _I Friday I_ _I_ _I_ _I_ _I_ _I
Saturday I _ _I_ _I_ _I_ _I_ _I Saturday I_ _I_ _I_ _I_ _I_ _I

[182] Partition 2 Arm Shedule [186] Partition 6 Arm Shedule
Sunday I_ _I_ _I_ _I_ _I_ _I Sunday I_ _I_ _I_ _I_ _I_ _I
Monday I_ _I_ _I_ _I_ _I_ _I Monday I_ _I_ _I_ _I_ _I_ _I
Tuesday I_ _I_ _I_ _I_ _I_ _I Tuesday I_ _I_ _I_ _I_ _I_ _I
Wednesday I_ _I_ _I_ _I_ _I_ _I Wednesday I_ _I_ _I_ _I_ _I_ _I
Thursday I_ _I_ _I_ _I_ _I_ _I Thursday I_ _I_ _I_ _I_ _I_ _I
Friday I_ _I_ _I_ _I_ _I_ _I Friday I_ _I_ _I_ _I_ _I_ _I
Saturday I_ _I_ _I_ _I_ _I_ _I Saturday I_ _I_ _I_ _I_ _I_ _I

[183] Partition 3 Arm Shedule [187] Partition 7 Arm Shedule
Sunday I_ _I_ _I_ _I_ _I_ _I Sunday I_ _I_ _I_ _I_ _I_ _I
Monday I_ _I_ _I_ _I_ _I_ _I Monday I_ _I_ _I_ _I_ _I_ _I
Tuesday I_ _I_ _I_ _I_ _I_ _I Tuesday I_ _I_ _I_ _I_ _I_ _I
Wednesday I_ _I_ _I_ _I_ _I_ _I Wednesday I_ _I_ _I_ _I_ _I_ _I
Thursday I_ _I_ _I_ _I_ _I_ _I Thursday I_ _I_ _I_ _I_ _I_ _I
Friday I_ _I_ _I_ _I_ _I_ _I Friday I_ _I_ _I_ _I_ _I_ _I
Saturday I_ _I_ _I_ _I_ _I_ _I Saturday I_ _I_ _I_ _I_ _I_ _I

[184] Partition 4 Arm Shedule [188] Partition 8 Arm Shedule
Sunday I_ _I_ _I_ _I_ _I_ _I Sunday I_ _I_ _I_ _I_ _I_ _I
Monday I_ _I_ _I_ _I_ _I_ _I Monday I_ _I_ _I_ _I_ _I_ _I
Tuesday I_ _I_ _I_ _I_ _I_ _I Tuesday I_ _I_ _I_ _I_ _I_ _I
Wednesday I_ _I_ _I_ _I_ _I_ _I Wednesday I_ _I_ _I_ _I_ _I_ _I
Thursday I_ _I_ _I_ _I_ _I_ _I Thursday I_ _I_ _I_ _I_ _I_ _I
Friday I_ _I_ _I_ _I_ _I_ _I Friday I_ _I_ _I_ _I_ _I_ _I
Saturday I_ _I_ _I_ _I_ _I_ _I Saturday I_ _I_ _I_ _I_ _I_ _I
[190] No Activity Arming Pre-Alert Time (All Partitions)
Default
001 I_ _I_ _I_ _I Valid entries are 001-255 seconds, 000 = no Pre-alert

[191] Partition 1 No Activity Timer
Default
000 I_ _I_ _I_ _I Valid entries are 001-255 seconds, 000 = Disable

[192] Partition 2 No Activity Timer
Default
000 I_ _I_ _I_ _I Valid entries are 001-255 seconds, 000 = Disable

[193] Partition 3 No Activity Timer
Default
000 I_ _I_ _I_ _I Valid entries are 001-255 seconds, 000 = Disable

[194] Partition 4 No Activity Timer
Default
000 I_ _I_ _I_ _I Valid entries are 001-255 seconds, 000 = Disable

[195] Partition 5 No Activity Timer
Default
000 I_ _I_ _I_ _I Valid entries are 001-255 seconds, 000 = Disable

[196] Partition 6 No Activity Timer
Default
000 I_ _I_ _I_ _I Valid entries are 001-255 seconds, 000 = Disable

[197] Partition 7 No Activity Timer
Default
000 I_ _I_ _I_ _I Valid entries are 001-255 seconds, 000 = Disable

[198] Partition 8 No Activity Timer
Default
000 I_ _I_ _I_ _I Valid entries are 001-255 seconds, 000 = Disable

[201] Partition Mask
Default Option ON OFF
ON I_ON_I 1 Partition 1 is Enabled Partition 1 is Disabled
OFF I_OFF_I 2 Partition 2 is Enabled Partition 2 is Disabled
OFF I_OFF_I 3 Partition 3 is Enabled Partition 3 is Disabled
OFF I_OFF_I 4 Partition 4 is Enabled Partition 4 is Disabled
OFF I_OFF_I 5 Partition 5 is Enabled Partition 5 is Disabled
OFF I_OFF_I 6 Partition 6 is Enabled Partition 6 is Disabled
OFF I_OFF_I 7 Partition 7 is Enabled Partition 7 is Disabled
OFF I_OFF_I 8 Partition 8 is Enabled Partition 8 is Disabled

[202] Partition 1 Selection Mask (Zn 01 to 18) [203] Partition 1 Selection Mask (Zn 09 to 16)
Default Option ON Default Option ON
ON I_ON_I 1 Zone 1 Enabled OFF I_OFF_I 1 Zone 9 Enabled
ON I_ON_I 2 Zone 2 Enabled OFF I_OFF_I 2 Zone 10 Enabled
ON I_ON_I 3 Zone 3 Enabled OFF I_OFF_I 3 Zone 11 Enabled
ON I_ON_I 4 Zone 4 Enabled OFF I_OFF_I 4 Zone 12 Enabled
ON I_ON_I 5 Zone 5 Enabled OFF I_OFF_I 5 Zone 13 Enabled
ON I_ON_I 6 Zone 6 Enabled OFF I_OFF_I 6 Zone 14 Enabled
ON I_ON_I 7 Zone 7 Enabled OFF I_OFF_I 7 Zone 15 Enabled
ON I_ON_I 8 Zone 8 Enabled OFF I_OFF_I 8 Zone 16 Enabled

[204] Partition 1 Selection Mask (Zn 17 to 24) [205] Partition 1 Selection Mask (Zn 251 to 32)
Default Option ON Default Option ON
OFF I_OFF_I 1 Zone 17 Enabled OFF I_OFF_I 1 Zone 25 Enabled
OFF I_OFF_I 2 Zone 18 Enabled OFF I_OFF_I 2 Zone 26 Enabled
OFF I_OFF_I 3 Zone 19 Enabled OFF I_OFF_I 3 Zone 27 Enabled
OFF I_OFF_I 4 Zone 20 Enabled OFF I_OFF_I 4 Zone 28 Enabled
OFF I_OFF_I 5 Zone 21 Enabled OFF I_OFF_I 5 Zone 29 Enabled
OFF I_OFF_I 6 Zone 22 Enabled OFF I_OFF_I 6 Zone 30 Enabled
OFF I_OFF_I 7 Zone 23 Enabled OFF I_OFF_I 7 Zone 31 Enabled
OFF I_OFF_I 8 Zone 24 Enabled OFF I_OFF_I 8 Zone 32 Enabled

[206] Partition 1 Selection Mask (Zn 33 to 40) [207] Partition 1 Selection Mask (Zn 41 to 48)
Default Option ON Default Option ON
OFF I_OFF_I 1 Zone 33 Enabled OFF I_OFF_I 1 Zone 41 Enabled
OFF I_OFF_I 2 Zone 34 Enabled OFF I_OFF_I 2 Zone 42 Enabled
OFF I_OFF_I 3 Zone 35 Enabled OFF I_OFF_I 3 Zone 43 Enabled
OFF I_OFF_I 4 Zone 36 Enabled OFF I_OFF_I 4 Zone 44 Enabled
OFF I_OFF_I 5 Zone 37 Enabled OFF I_OFF_I 5 Zone 45 Enabled
OFF I_OFF_I 6 Zone 38 Enabled OFF I_OFF_I 6 Zone 46 Enabled
OFF I_OFF_I 7 Zone 39 Enabled OFF I_OFF_I 7 Zone 47 Enabled
OFF I_OFF_I 8 Zone 40 Enabled OFF I_OFF_I 8 Zone 48 Enabled

[208] Partition 1 Selection Mask (Zn 49 to 56) [209] Partition 1 Selection Mask (Zn 57 to 64)
Default Option ON Default Option ON
OFF I_OFF_I 1 Zone 49 Enabled OFF I_OFF_I 1 Zone 57 Enabled
OFF I_OFF_I 2 Zone 50 Enabled OFF I_OFF_I 2 Zone 58 Enabled
OFF I_OFF_I 3 Zone 51 Enabled OFF I_OFF_I 3 Zone 59 Enabled
OFF I_OFF_I 4 Zone 52 Enabled OFF I_OFF_I 4 Zone 60 Enabled
OFF I_OFF_I 5 Zone 53 Enabled OFF I_OFF_I 5 Zone 61 Enabled
OFF I_OFF_I 6 Zone 54 Enabled OFF I_OFF_I 6 Zone 62 Enabled
OFF I_OFF_I 7 Zone 55 Enabled OFF I_OFF_I 7 Zone 63 Enabled
OFF I_OFF_I 8 Zone 56 Enabled OFF I_OFF_I 8 Zone 64 Enabled

Partition 2 Zone Assignments
[210] Partition 2 Selection Mask (Zn 01 to 18) [211] Partition 2 Selection Mask (Zn 09 to 16)
Default Option ON Default Option ON
OFF I_OFF_I 1 Zone 1 Enabled OFF I_OFF_I 1 Zone 9 Enabled
OFF I_OFF_I 2 Zone 2 Enabled OFF I_OFF_I 2 Zone 10 Enabled
OFF I_OFF_I 3 Zone 3 Enabled OFF I_OFF_I 3 Zone 11 Enabled
OFF I_OFF_I 4 Zone 4 Enabled OFF I_OFF_I 4 Zone 12 Enabled
OFF I_OFF_I 5 Zone 5 Enabled OFF I_OFF_I 5 Zone 13 Enabled
OFF I_OFF_I 6 Zone 6 Enabled OFF I_OFF_I 6 Zone 14 Enabled
OFF I_OFF_I 7 Zone 7 Enabled OFF I_OFF_I 7 Zone 15 Enabled
OFF I_OFF_I 8 Zone 8 Enabled OFF I_OFF_I 8 Zone 16 Enabled

[212] Partition 2 Selection Mask (Zn 17 to 24) [213] Partition 2 Selection Mask (Zn 251 to 32)

[214] Partition 2 Selection Mask (Zn 33 to 40) [215] Partition 2 Selection Mask (Zn 41 to 48)

[216] Partition 2 Selection Mask (Zn 49 to 56) [217] Partition 2 Selection Mask (Zn 57 to 64)

Partition 3 Zone Assignments
[218] Partition 3 Selection Mask (Zn 01 to 18) [219] Partition 3 Selection Mask (Zn 09 to 16)
Default Option ON Default Option ON
OFF I_OFF_I 1 Zone 1 Enabled OFF I_OFF_I 1 Zone 9 Enabled
OFF I_OFF_I 2 Zone 2 Enabled OFF I_OFF_I 2 Zone 10 Enabled
OFF I_OFF_I 3 Zone 3 Enabled OFF I_OFF_I 3 Zone 11 Enabled
OFF I_OFF_I 4 Zone 4 Enabled OFF I_OFF_I 4 Zone 12 Enabled
OFF I_OFF_I 5 Zone 5 Enabled OFF I_OFF_I 5 Zone 13 Enabled
OFF I_OFF_I 6 Zone 6 Enabled OFF I_OFF_I 6 Zone 14 Enabled
OFF I_OFF_I 7 Zone 7 Enabled OFF I_OFF_I 7 Zone 15 Enabled
OFF I_OFF_I 8 Zone 8 Enabled OFF I_OFF_I 8 Zone 16 Enabled

[220] Partition 3 Selection Mask (Zn 17 to 24) [221] Partition 3 Selection Mask (Zn 251 to 32)

[222] Partition 3 Selection Mask (Zn 33 to 40) [223] Partition 3 Selection Mask (Zn 41 to 48)

[224] Partition 3 Selection Mask (Zn 49 to 56) [225] Partition 3 Selection Mask (Zn 57 to 64)

Partition 4 Zone Assignments
[226] Partition 4 Selection Mask (Zn 01 to 18) [227] Partition 4 Selection Mask (Zn 09 to 16)
Default Option ON Default Option ON
OFF I_OFF_I 1 Zone 1 Enabled OFF I_OFF_I 1 Zone 9 Enabled
OFF I_OFF_I 2 Zone 2 Enabled OFF I_OFF_I 2 Zone 10 Enabled
OFF I_OFF_I 3 Zone 3 Enabled OFF I_OFF_I 3 Zone 11 Enabled
OFF I_OFF_I 4 Zone 4 Enabled OFF I_OFF_I 4 Zone 12 Enabled
OFF I_OFF_I 5 Zone 5 Enabled OFF I_OFF_I 5 Zone 13 Enabled
OFF I_OFF_I 6 Zone 6 Enabled OFF I_OFF_I 6 Zone 14 Enabled
OFF I_OFF_I 7 Zone 7 Enabled OFF I_OFF_I 7 Zone 15 Enabled
OFF I_OFF_I 8 Zone 8 Enabled OFF I_OFF_I 8 Zone 16 Enabled

[228] Partition 4 Selection Mask (Zn 17 to 24) [229] Partition 4 Selection Mask (Zn 251 to 32)

[230] Partition 4 Selection Mask (Zn 33 to 40) [231] Partition 4 Selection Mask (Zn 41 to 48)

[232] Partition 4 Selection Mask (Zn 49 to 56) [233] Partition 4 Selection Mask (Zn 57 to 64)

Partition 5 Zone Assignments
[234] Partition 5 Selection Mask (Zn 01 to 18) [235] Partition 5 Selection Mask (Zn 09 to 16)
Default Option ON Default Option ON
OFF I_OFF_I 1 Zone 1 Enabled OFF I_OFF_I 1 Zone 9 Enabled
OFF I_OFF_I 2 Zone 2 Enabled OFF I_OFF_I 2 Zone 10 Enabled
OFF I_OFF_I 3 Zone 3 Enabled OFF I_OFF_I 3 Zone 11 Enabled
OFF I_OFF_I 4 Zone 4 Enabled OFF I_OFF_I 4 Zone 12 Enabled
OFF I_OFF_I 5 Zone 5 Enabled OFF I_OFF_I 5 Zone 13 Enabled
OFF I_OFF_I 6 Zone 6 Enabled OFF I_OFF_I 6 Zone 14 Enabled
OFF I_OFF_I 7 Zone 7 Enabled OFF I_OFF_I 7 Zone 15 Enabled
OFF I_OFF_I 8 Zone 8 Enabled OFF I_OFF_I 8 Zone 16 Enabled

[236] Partition 5 Selection Mask (Zn 17 to 24) [237] Partition 5 Selection Mask (Zn 251 to 32)

[238] Partition 5 Selection Mask (Zn 33 to 40) [239] Partition 5 Selection Mask (Zn 41 to 48)

[240] Partition 5 Selection Mask (Zn 49 to 56) [241] Partition 5 Selection Mask (Zn 57 to 64)

Partition 6 Zone Assignments
[242] Partition 6 Selection Mask (Zn 01 to 18) [243] Partition 6 Selection Mask (Zn 09 to 16)
Default Option ON Default Option ON
OFF I_OFF_I 1 Zone 1 Enabled OFF I_OFF_I 1 Zone 9 Enabled
OFF I_OFF_I 2 Zone 2 Enabled OFF I_OFF_I 2 Zone 10 Enabled
OFF I_OFF_I 3 Zone 3 Enabled OFF I_OFF_I 3 Zone 11 Enabled
OFF I_OFF_I 4 Zone 4 Enabled OFF I_OFF_I 4 Zone 12 Enabled
OFF I_OFF_I 5 Zone 5 Enabled OFF I_OFF_I 5 Zone 13 Enabled
OFF I_OFF_I 6 Zone 6 Enabled OFF I_OFF_I 6 Zone 14 Enabled
OFF I_OFF_I 7 Zone 7 Enabled OFF I_OFF_I 7 Zone 15 Enabled
OFF I_OFF_I 8 Zone 8 Enabled OFF I_OFF_I 8 Zone 16 Enabled

[244] Partition 6 Selection Mask (Zn 17 to 24) [245] Partition 6 Selection Mask (Zn 251 to 32)

[246] Partition 6 Selection Mask (Zn 33 to 40) [247] Partition 6 Selection Mask (Zn 41 to 48)

[248] Partition 6 Selection Mask (Zn 49 to 56) [249] Partition 6 Selection Mask (Zn 57 to 64)

Partition 7 Zone Assignments
[250] Partition 7 Selection Mask (Zn 01 to 18) [251] Partition 7 Selection Mask (Zn 09 to 16)
Default Option ON Default Option ON
OFF I_OFF_I 1 Zone 1 Enabled OFF I_OFF_I 1 Zone 9 Enabled
OFF I_OFF_I 2 Zone 2 Enabled OFF I_OFF_I 2 Zone 10 Enabled
OFF I_OFF_I 3 Zone 3 Enabled OFF I_OFF_I 3 Zone 11 Enabled
OFF I_OFF_I 4 Zone 4 Enabled OFF I_OFF_I 4 Zone 12 Enabled
OFF I_OFF_I 5 Zone 5 Enabled OFF I_OFF_I 5 Zone 13 Enabled
OFF I_OFF_I 6 Zone 6 Enabled OFF I_OFF_I 6 Zone 14 Enabled
OFF I_OFF_I 7 Zone 7 Enabled OFF I_OFF_I 7 Zone 15 Enabled
OFF I_OFF_I 8 Zone 8 Enabled OFF I_OFF_I 8 Zone 16 Enabled

[252] Partition 7 Selection Mask (Zn 17 to 24) [253] Partition 7 Selection Mask (Zn 251 to 32)

[254] Partition 7 Selection Mask (Zn 33 to 40) [255] Partition 7 Selection Mask (Zn 41 to 48)

[256] Partition 7 Selection Mask (Zn 49 to 56) [257] Partition 7 Selection Mask (Zn 57 to 64)

Partition 8 Zone Assignments
[258] Partition 8 Selection Mask (Zn 01 to 18) [259] Partition 8 Selection Mask (Zn 09 to 16)
Default Option ON Default Option ON
OFF I_OFF_I 1 Zone 1 Enabled OFF I_OFF_I 1 Zone 9 Enabled
OFF I_OFF_I 2 Zone 2 Enabled OFF I_OFF_I 2 Zone 10 Enabled
OFF I_OFF_I 3 Zone 3 Enabled OFF I_OFF_I 3 Zone 11 Enabled
OFF I_OFF_I 4 Zone 4 Enabled OFF I_OFF_I 4 Zone 12 Enabled
OFF I_OFF_I 5 Zone 5 Enabled OFF I_OFF_I 5 Zone 13 Enabled
OFF I_OFF_I 6 Zone 6 Enabled OFF I_OFF_I 6 Zone 14 Enabled
OFF I_OFF_I 7 Zone 7 Enabled OFF I_OFF_I 7 Zone 15 Enabled
OFF I_OFF_I 8 Zone 8 Enabled OFF I_OFF_I 8 Zone 16 Enabled

[260] Partition 8 Selection Mask (Zn 17 to 24) [261] Partition 8 Selection Mask (Zn 251 to 32)

[262] Partition 8 Selection Mask (Zn 33 to 40) [263] Partition 8 Selection Mask (Zn 41 to 48)

[264] Partition 8 Selection Mask (Zn 49 to 56) [265] Partition 8 Selection Mask (Zn 57 to 64)

Communicator Programming
[301] First Telephone Number (32 Digits)
I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I
*2* (B) = * *3* (C) = # *4* (D) = Wait for Dial Tone *5* (E) = 2 Sec Pause *6* (F) = End Number
(If adding more than one hex digit Example: *555* gives 3 2-second pauses)

[302] Second Telephone Number (32 Digits)
I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I
If Pager program Number + pauses *5555* gives 4 2-second pauses
Pager will not send properly if Hex Characters A C D F are in Account Number

[303] Third Telephone Number (32 Digits)
I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I

[304] Call Waiting Cancel String
Default
DB70EF I_ _I_ _I_ _I_ _I_ _I_ _I

[310] System Account Identifier Code (6 Digits)
I_ _I_ _I_ _I_ _I_ _I_ _I
If SIA enter 0 if any 0 in Account Number
Only SIA will support 6 digit account numbers.
If using a 4 digit account number, enter FF after the account number
If 4/2 or Contact ID use *1* for any 0 in Account Number
Pager will not send properly if Hex Characters A C D F are in Account Number

[311] Partition 1 Account Identifier Code (4 Digits)
I_ _I_ _I_ _I_ _I

[313] Partition 2 Account Identifier Code (4 Digits)
I_ _I_ _I_ _I_ _I

[314] Partition 3 Account Identifier Code (4 Digits)
I_ _I_ _I_ _I_ _I

[315] Partition 4 Account Identifier Code (4 Digits)
I_ _I_ _I_ _I_ _I

[316] Partition 5 Account Identifier Code (4 Digits)
I_ _I_ _I_ _I_ _I

[317] Partition 6 Account Identifier Code (4 Digits)
I_ _I_ _I_ _I_ _I

[318] Partition 7 Account Identifier Code (4 Digits)
I_ _I_ _I_ _I_ _I

[319] Partition 8 Account Identifier Code (4 Digits)
I_ _I_ _I_ _I_ _I

[320] Alarm Report Codes Zone 01 to 16
I_F_I_F_I Zone 01 Alarm I_F_I_F_I Zone 09 Alarm
I_F_I_F_I Zone 02 Alarm I_F_I_F_I Zone 10 Alarm
I_F_I_F_I Zone 03 Alarm I_F_I_F_I Zone 11 Alarm
I_F_I_F_I Zone 04 Alarm I_F_I_F_I Zone 12 Alarm
I_F_I_F_I Zone 05 Alarm I_F_I_F_I Zone 13 Alarm
I_F_I_F_I Zone 06 Alarm I_F_I_F_I Zone 14 Alarm
I_F_I_F_I Zone 07 Alarm I_F_I_F_I Zone 15 Alarm
I_F_I_F_I Zone 08 Alarm I_F_I_F_I Zone 16 Alarm

[321] Alarm Report Codes Zone 17 to 32
I_F_I_F_I Zone 17 Alarm I_F_I_F_I Zone 25 Alarm
I_F_I_F_I Zone 18 Alarm I_F_I_F_I Zone 26 Alarm
I_F_I_F_I Zone 19 Alarm I_F_I_F_I Zone 27 Alarm
I_F_I_F_I Zone 20 Alarm I_F_I_F_I Zone 28 Alarm
I_F_I_F_I Zone 21 Alarm I_F_I_F_I Zone 29 Alarm
I_F_I_F_I Zone 22 Alarm I_F_I_F_I Zone 30 Alarm
I_F_I_F_I Zone 23 Alarm I_F_I_F_I Zone 31 Alarm
I_F_I_F_I Zone 24 Alarm I_F_I_F_I Zone 32 Alarm

[322] Alarm Report Codes Zone 33 to 48
I_F_I_F_I Zone 33 Alarm I_F_I_F_I Zone 41 Alarm
I_F_I_F_I Zone 34 Alarm I_F_I_F_I Zone 42 Alarm
I_F_I_F_I Zone 35 Alarm I_F_I_F_I Zone 43 Alarm
I_F_I_F_I Zone 36 Alarm I_F_I_F_I Zone 44 Alarm
I_F_I_F_I Zone 37 Alarm I_F_I_F_I Zone 45 Alarm
I_F_I_F_I Zone 38 Alarm I_F_I_F_I Zone 46 Alarm
I_F_I_F_I Zone 39 Alarm I_F_I_F_I Zone 47 Alarm
I_F_I_F_I Zone 40 Alarm I_F_I_F_I Zone 48 Alarm

[323] Alarm Report Codes Zone 49 to 64
I_F_I_F_I Zone 49 Alarm I_F_I_F_I Zone 57 Alarm
I_F_I_F_I Zone 50 Alarm I_F_I_F_I Zone 58 Alarm
I_F_I_F_I Zone 51 Alarm I_F_I_F_I Zone 59 Alarm
I_F_I_F_I Zone 52 Alarm I_F_I_F_I Zone 60 Alarm
I_F_I_F_I Zone 53 Alarm I_F_I_F_I Zone 61 Alarm
I_F_I_F_I Zone 54 Alarm I_F_I_F_I Zone 62 Alarm
I_F_I_F_I Zone 55 Alarm I_F_I_F_I Zone 63 Alarm
I_F_I_F_I Zone 56 Alarm I_F_I_F_I Zone 64 Alarm

[324] Alarm Restoral Report Codes Zones 01 to 16
I_F_I_F_I Zone 01 Alarm Restore I_F_I_F_I Zone 09 Alarm Restore
I_F_I_F_I Zone 02 Alarm Restore I_F_I_F_I Zone 10 Alarm Restore
I_F_I_F_I Zone 03 Alarm Restore I_F_I_F_I Zone 11 Alarm Restore
I_F_I_F_I Zone 04 Alarm Restore I_F_I_F_I Zone 12 Alarm Restore
I_F_I_F_I Zone 05 Alarm Restore I_F_I_F_I Zone 13 Alarm Restore
I_F_I_F_I Zone 06 Alarm Restore I_F_I_F_I Zone 14 Alarm Restore
I_F_I_F_I Zone 07 Alarm Restore I_F_I_F_I Zone 15 Alarm Restore
I_F_I_F_I Zone 08 Alarm Restore I_F_I_F_I Zone 16 Alarm Restore

[325] Alarm Restoral Report Codes Zone 17 to 32
I_F_I_F_I Zone 17 Alarm Restore I_F_I_F_I Zone 25 Alarm Restore
I_F_I_F_I Zone 18 Alarm Restore I_F_I_F_I Zone 26 Alarm Restore
I_F_I_F_I Zone 19 Alarm Restore I_F_I_F_I Zone 27 Alarm Restore
I_F_I_F_I Zone 20 Alarm Restore I_F_I_F_I Zone 28 Alarm Restore
I_F_I_F_I Zone 21 Alarm Restore I_F_I_F_I Zone 29 Alarm Restore
I_F_I_F_I Zone 22 Alarm Restore I_F_I_F_I Zone 30 Alarm Restore
I_F_I_F_I Zone 23 Alarm Restore I_F_I_F_I Zone 31 Alarm Restore
I_F_I_F_I Zone 24 Alarm Restore I_F_I_F_I Zone 32 Alarm Restore

[326] Alarm Restoral Report Codes Zone 33 to 48
I_F_I_F_I Zone 33 Alarm Restore I_F_I_F_I Zone 41 Alarm Restore
I_F_I_F_I Zone 34 Alarm Restore I_F_I_F_I Zone 42 Alarm Restore
I_F_I_F_I Zone 35 Alarm Restore I_F_I_F_I Zone 43 Alarm Restore
I_F_I_F_I Zone 36 Alarm Restore I_F_I_F_I Zone 44 Alarm Restore
I_F_I_F_I Zone 37 Alarm Restore I_F_I_F_I Zone 45 Alarm Restore
I_F_I_F_I Zone 38 Alarm Restore I_F_I_F_I Zone 46 Alarm Restore
I_F_I_F_I Zone 39 Alarm Restore I_F_I_F_I Zone 47 Alarm Restore
I_F_I_F_I Zone 40 Alarm Restore I_F_I_F_I Zone 48 Alarm Restore

[327] Alarm Restoral Report Codes Zone 49 to 64
I_F_I_F_I Zone 49 Alarm Restore I_F_I_F_I Zone 57 Alarm Restore
I_F_I_F_I Zone 50 Alarm Restore I_F_I_F_I Zone 58 Alarm Restore
I_F_I_F_I Zone 51 Alarm Restore I_F_I_F_I Zone 59 Alarm Restore
I_F_I_F_I Zone 52 Alarm Restore I_F_I_F_I Zone 60 Alarm Restore
I_F_I_F_I Zone 53 Alarm Restore I_F_I_F_I Zone 61 Alarm Restore
I_F_I_F_I Zone 54 Alarm Restore I_F_I_F_I Zone 62 Alarm Restore
I_F_I_F_I Zone 55 Alarm Restore I_F_I_F_I Zone 63 Alarm Restore
I_F_I_F_I Zone 56 Alarm Restore I_F_I_F_I Zone 64 Alarm Restore

[328] Miscellaneous Alarm Report Codes
I_F_I_F_I Duress I_F_I_F_I Zone Expander Supervisory Restore
I_F_I_F_I Opening After Alarm I_F_I_F_I Cross Zone Police Code Alarm
I_F_I_F_I Recent Closing/Exit Alarm I_F_I_F_I Burglary Not Verified
I_F_I_F_I Zone Expander Superv. I_F_I_F_I Alarm Cancelled

[329] Priority Alarm and Restoral Report Codes
I_F_I_F_I Keypad Fire Alarm I_F_I_F_I Keypad Fire Restoral
I_F_I_F_I Keypad Aux Alarm I_F_I_F_I Keypad Aux Restoral
I_F_I_F_I Keypad Panic Alarm I_F_I_F_I Keypad Panic Restoral
I_F_I_F_I Auxiliary Input Alarm I_F_I_F_I Auxiliary Input Restore

[330] Tamper Report Codes, Zone 01 to 16
I_F_I_F_I Zone 01 Tamper I_F_I_F_I Zone 09 Tamper
I_F_I_F_I Zone 02 Tamper I_F_I_F_I Zone 10 Tamper
I_F_I_F_I Zone 03 Tamper I_F_I_F_I Zone 11 Tamper
I_F_I_F_I Zone 04 Tamper I_F_I_F_I Zone 12 Tamper
I_F_I_F_I Zone 05 Tamper I_F_I_F_I Zone 13 Tamper
I_F_I_F_I Zone 06 Tamper I_F_I_F_I Zone 14 Tamper
I_F_I_F_I Zone 07 Tamper I_F_I_F_I Zone 15 Tamper
I_F_I_F_I Zone 08 Tamper I_F_I_F_I Zone 16 Tamper

[331] Tamper Report Codes Zone 17 to 32
I_F_I_F_I Zone 17 Tamper I_F_I_F_I Zone 25 Tamper
I_F_I_F_I Zone 18 Tamper I_F_I_F_I Zone 26 Tamper
I_F_I_F_I Zone 19 Tamper I_F_I_F_I Zone 27 Tamper
I_F_I_F_I Zone 20 Tamper I_F_I_F_I Zone 28 Tamper
I_F_I_F_I Zone 21 Tamper I_F_I_F_I Zone 29 Tamper
I_F_I_F_I Zone 22 Tamper I_F_I_F_I Zone 30 Tamper
I_F_I_F_I Zone 23 Tamper I_F_I_F_I Zone 31 Tamper
I_F_I_F_I Zone 24 Tamper I_F_I_F_I Zone 32 Tamper

[332] Tamper Report Codes Zone 33 to 48
I_F_I_F_I Zone 33 Tamper I_F_I_F_I Zone 41 Tamper
I_F_I_F_I Zone 34 Tamper I_F_I_F_I Zone 42 Tamper
I_F_I_F_I Zone 35 Tamper I_F_I_F_I Zone 43 Tamper
I_F_I_F_I Zone 36 Tamper I_F_I_F_I Zone 44 Tamper
I_F_I_F_I Zone 37 Tamper I_F_I_F_I Zone 45 Tamper
I_F_I_F_I Zone 38 Tamper I_F_I_F_I Zone 46 Tamper
I_F_I_F_I Zone 39 Tamper I_F_I_F_I Zone 47 Tamper
I_F_I_F_I Zone 40 Tamper I_F_I_F_I Zone 48 Tamper

[333] Tamper Report Codes Zone 49 to 64
I_F_I_F_I Zone 49 Tamper I_F_I_F_I Zone 57 Tamper
I_F_I_F_I Zone 50 Tamper I_F_I_F_I Zone 58 Tamper
I_F_I_F_I Zone 51 Tamper I_F_I_F_I Zone 59 Tamper
I_F_I_F_I Zone 52 Tamper I_F_I_F_I Zone 60 Tamper
I_F_I_F_I Zone 53 Tamper I_F_I_F_I Zone 61 Tamper
I_F_I_F_I Zone 54 Tamper I_F_I_F_I Zone 62 Tamper
I_F_I_F_I Zone 55 Tamper I_F_I_F_I Zone 63 Tamper
I_F_I_F_I Zone 56 Tamper I_F_I_F_I Zone 64 Tamper

[334] Tamper Restoral Report Codes, Zone 01 to 16
I_F_I_F_I Zone 01 Tamper Restore I_F_I_F_I Zone 09 Tamper Restore
I_F_I_F_I Zone 02 Tamper Restore I_F_I_F_I Zone 10 Tamper Restore
I_F_I_F_I Zone 03 Tamper Restore I_F_I_F_I Zone 11 Tamper Restore
I_F_I_F_I Zone 04 Tamper Restore I_F_I_F_I Zone 12 Tamper Restore
I_F_I_F_I Zone 05 Tamper Restore I_F_I_F_I Zone 13 Tamper Restore
I_F_I_F_I Zone 06 Tamper Restore I_F_I_F_I Zone 14 Tamper Restore
I_F_I_F_I Zone 07 Tamper Restore I_F_I_F_I Zone 15 Tamper Restore
I_F_I_F_I Zone 08 Tamper Restore I_F_I_F_I Zone 16 Tamper Restore

[335] Tamper Restoral Report Codes Zone 17 to 32
I_F_I_F_I Zone 17 Tamper Restore I_F_I_F_I Zone 25 Tamper Restore
I_F_I_F_I Zone 18 Tamper Restore I_F_I_F_I Zone 26 Tamper Restore
I_F_I_F_I Zone 19 Tamper Restore I_F_I_F_I Zone 27 Tamper Restore
I_F_I_F_I Zone 20 Tamper Restore I_F_I_F_I Zone 28 Tamper Restore
I_F_I_F_I Zone 21 Tamper Restore I_F_I_F_I Zone 29 Tamper Restore
I_F_I_F_I Zone 22 Tamper Restore I_F_I_F_I Zone 30 Tamper Restore
I_F_I_F_I Zone 23 Tamper Restore I_F_I_F_I Zone 31 Tamper Restore
I_F_I_F_I Zone 24 Tamper Restore I_F_I_F_I Zone 32 Tamper Restore

[336] Tamper Restoral Report Codes Zone 33 to 48
I_F_I_F_I Zone 33 Tamper Restore I_F_I_F_I Zone 41 Tamper Restore
I_F_I_F_I Zone 34 Tamper Restore I_F_I_F_I Zone 42 Tamper Restore
I_F_I_F_I Zone 35 Tamper Restore I_F_I_F_I Zone 43 Tamper Restore
I_F_I_F_I Zone 36 Tamper Restore I_F_I_F_I Zone 44 Tamper Restore
I_F_I_F_I Zone 37 Tamper Restore I_F_I_F_I Zone 45 Tamper Restore
I_F_I_F_I Zone 38 Tamper Restore I_F_I_F_I Zone 46 Tamper Restore
I_F_I_F_I Zone 39 Tamper Restore I_F_I_F_I Zone 47 Tamper Restore
I_F_I_F_I Zone 40 Tamper Restore I_F_I_F_I Zone 48 Tamper Restore

[337] Tamper Restoral Report Codes Zone 49 to 64
I_F_I_F_I Zone 49 Tamper Restore I_F_I_F_I Zone 57 Tamper Restore
I_F_I_F_I Zone 50 Tamper Restore I_F_I_F_I Zone 58 Tamper Restore
I_F_I_F_I Zone 51 Tamper Restore I_F_I_F_I Zone 59 Tamper Restore
I_F_I_F_I Zone 52 Tamper Restore I_F_I_F_I Zone 60 Tamper Restore
I_F_I_F_I Zone 53 Tamper Restore I_F_I_F_I Zone 61 Tamper Restore
I_F_I_F_I Zone 54 Tamper Restore I_F_I_F_I Zone 62 Tamper Restore
I_F_I_F_I Zone 55 Tamper Restore I_F_I_F_I Zone 63 Tamper Restore
I_F_I_F_I Zone 56 Tamper Restore I_F_I_F_I Zone 64 Tamper Restore

[338] Miscellaneous Tamper Reporting Codes
I_0_I_0_I General System Tamper
I_0_I_0_I General System Tamper Restoral
I_0_I_0_I Keypad Lockout

[339] Closing (Arming) Report Codes, Access Codes 01 to 16
I_0_I_0_I User Code 01 I_0_I_0_I User Code 09
I_0_I_0_I User Code 02 I_0_I_0_I User Code 10
I_0_I_0_I User Code 03 I_0_I_0_I User Code 11
I_0_I_0_I User Code 04 I_0_I_0_I User Code 12
I_0_I_0_I User Code 05 I_0_I_0_I User Code 13
I_0_I_0_I User Code 06 I_0_I_0_I User Code 14
I_0_I_0_I User Code 07 I_0_I_0_I User Code 15
I_0_I_0_I User Code 08 I_0_I_0_I User Code 16

[340] Closing (Arming) Report Codes, Access Codes 17 to 32
I_0_I_0_I User Code 17 I_0_I_0_I User Code 25
I_0_I_0_I User Code 18 I_0_I_0_I User Code 26
I_0_I_0_I User Code 19 I_0_I_0_I User Code 27
I_0_I_0_I User Code 20 I_0_I_0_I User Code 28
I_0_I_0_I User Code 21 I_0_I_0_I User Code 29
I_0_I_0_I User Code 22 I_0_I_0_I User Code 30
I_0_I_0_I User Code 23 I_0_I_0_I User Code 31
I_0_I_0_I User Code 24 I_0_I_0_I User Code 32

[341] Miscellaneous Closing (Arming) Report Codes
I_0_I_0_I Closing Duress 33 I_0_I_0_I Closing Master42
I_0_I_0_I Closing Duress 34 I_0_I_0_I Partial Closing
I_0_I_0_I Closing Master 40 I_0_I_0_I Special Closing
I_0_I_0_I Closing Master 41 I_0_I_0_I Late to Close

[342] Opening (Disarming) Report Codes, Access Codes 01 to 16
I_0_I_0_I User Code 01 I_0_I_0_I User Code 09
I_0_I_0_I User Code 02 I_0_I_0_I User Code 10
I_0_I_0_I User Code 03 I_0_I_0_I User Code 11
I_0_I_0_I User Code 04 I_0_I_0_I User Code 12
I_0_I_0_I User Code 05 I_0_I_0_I User Code 13
I_0_I_0_I User Code 06 I_0_I_0_I User Code 14
I_0_I_0_I User Code 07 I_0_I_0_I User Code 15
I_0_I_0_I User Code 08 I_0_I_0_I User Code 16

[343] Opening (Disarming) Report Codes, Access Codes 17 to 32
I_0_I_0_I User Code 17 I_0_I_0_I User Code 25
I_0_I_0_I User Code 18 I_0_I_0_I User Code 26
I_0_I_0_I User Code 19 I_0_I_0_I User Code 27
I_0_I_0_I User Code 20 I_0_I_0_I User Code 28
I_0_I_0_I User Code 21 I_0_I_0_I User Code 29
I_0_I_0_I User Code 22 I_0_I_0_I User Code 30
I_0_I_0_I User Code 23 I_0_I_0_I User Code 31
I_0_I_0_I User Code 24 I_0_I_0_I User Code 32

[344] Miscellaneous Opening (Disarming) Report Codes
I_0_I_0_I Opening Duress 33 I_0_I_0_I Opening Master42
I_0_I_0_I Opening Duress 34 I_0_I_0_I Auto Arm Cancellation
I_0_I_0_I Opening Master 40 I_0_I_0_I Special Opening

I_0_I_0_I Opening Master 41
[345] Maintenance Alarm Report Codes
I_F_I_F_I Battery Trouble I_F_I_F_I Auxiliary Power Supply Trouble
I_F_I_F_I AC Failure Trouble I_F_I_F_I TLM Trouble (via LINKS)
I_F_I_F_I Bell Circuit Trouble I_F_I_F_I General System Trouble
I_F_I_F_I Fire Trouble Alarm I_F_I_F_I General System Supervisory

[346] Maintenance Restoral Report Codes
I_0_I_0_I Battery Restore I_0_I_0_I Auxiliary Power Supply Restore
I_0_I_0_I AC Failure Restoral I_0_I_0_I TLM Restoral
I_0_I_0_I Bell Circuit Restoral I_0_I_0_I General System Trouble Restore
I_0_I_0_I Fire Trouble Restore I_0_I_0_I General System Supervisory Restore

[347] Miscellaneous Maintenance Report Codes
I_0_I_0_I Phone Number 1 Fail to Communicate
I_0_I_0_I Phone Number 2 Fail to Communicate
I_0_I_0_I Event Buffer 75% Full Since Last Upload
I_0_I_0_I DLS Lead IN
I_0_I_0_I DLS Lead OUT
I_0_I_0_I General Zone Trouble Alarm
I_0_I_0_I General Zone Trouble Restore
I_0_I_0_I Delinquency Code

[348] Test Transmission Report Codes
I_F_I_F_I Walk Test End I_F_I_F_I Periodic Test Transmission
I_F_I_F_I Walk Test Begin I_F_I_F_I System Test
I_F_I_F_I TLM Line 1 Trouble I_F_I_F_I LINKS 1000 Test Transmission Code

[350] Communicator Format Options (Third telephone number follows format of First)
Default
02 I_0_I_4_I 1st Phone Number
01 = 4/2 20 BPS 1400 HZ 05 = Pager
02 = 4/2 20 BPS 2300 HZ 06 = Residential Dial
03 = DTMF CONTACT ID 07 = 10 BPS, 1400Hz
04 = SIA FSK 08 = 10 BPS, 2300Hz
02 I_0_I_5_I 2nd Phone Number

Alarms/Restoral Communicator Call Directions
Zone Light 1 Zone Light 2 Zone Light 3 Zone Light 4 Zone Light 5
 1st Telephone   2nd Telephone   1st Telephone   2nd Telephone   Alternate 
Number Number via Links 1000 via Links Communicator
[351] Partition 1 I_ON_I I_OFF_I I_OFF_I I_OFF_I I_OFF_I
[352] Partition 2 I_ON_I I_OFF_I I_OFF_I I_OFF_I I_OFF_I
[353] Partition 3 I_ON_I I_OFF_I I_OFF_I I_OFF_I I_OFF_I
[354] Partition 4 I_ON_I I_OFF_I I_OFF_I I_OFF_I I_OFF_I
[355] Partition 5 I_ON_I I_OFF_I I_OFF_I I_OFF_I I_OFF_I
[356] Partition 6 I_ON_I I_OFF_I I_OFF_I I_OFF_I I_OFF_I
[357] Partition 7 I_ON_I I_OFF_I I_OFF_I I_OFF_I I_OFF_I
[358] Partition 8 I_ON_I I_OFF_I I_OFF_I I_OFF_I I_OFF_I

Tamper/Restore Communicatior Call Directions
Zone Light 1 Zone Light 2 Zone Light 3 Zone Light 4 Zone Light 5
 1st Telephone   2nd Telephone   1st Telephone   2nd Telephone   Alternate 
Number Number via Links 1000 via Links Communicator
[359] Partition 1 I_ON_I I_OFF_I I_OFF_I I_OFF_I I_OFF_I
[360] Partition 2 I_ON_I I_OFF_I I_OFF_I I_OFF_I I_OFF_I
[361] Partition 3 I_ON_I I_OFF_I I_OFF_I I_OFF_I I_OFF_I
[362] Partition 4 I_ON_I I_OFF_I I_OFF_I I_OFF_I I_OFF_I
[363] Partition 5 I_ON_I I_OFF_I I_OFF_I I_OFF_I I_OFF_I
[364] Partition 6 I_ON_I I_OFF_I I_OFF_I I_OFF_I I_OFF_I
[365] Partition 7 I_ON_I I_OFF_I I_OFF_I I_OFF_I I_OFF_I
[366] Partition 8 I_ON_I I_OFF_I I_OFF_I I_OFF_I I_OFF_I

Opening/Closing Communicatior Call Directions
Zone Light 1 Zone Light 2 Zone Light 3 Zone Light 4 Zone Light 5
 1st Telephone   2nd Telephone   1st Telephone   2nd Telephone   Alternate 
Number Number via Links 1000 via Links Communicator
[367] Partition 1 I_ON_I I_OFF_I I_OFF_I I_OFF_I I_OFF_I
[368] Partition 2 I_ON_I I_OFF_I I_OFF_I I_OFF_I I_OFF_I
[369] Partition 3 I_ON_I I_OFF_I I_OFF_I I_OFF_I I_OFF_I
[370] Partition 4 I_ON_I I_OFF_I I_OFF_I I_OFF_I I_OFF_I
[371] Partition 5 I_ON_I I_OFF_I I_OFF_I I_OFF_I I_OFF_I
[372] Partition 6 I_ON_I I_OFF_I I_OFF_I I_OFF_I I_OFF_I
[373] Partition 7 I_ON_I I_OFF_I I_OFF_I I_OFF_I I_OFF_I
[374] Partition 8 I_ON_I I_OFF_I I_OFF_I I_OFF_I I_OFF_I

[375] System Maintenance Alarms and Restorals Call Directions
Default Option ON OFF
ON I_ON_I 1 1st Telephone Number Disabled
OFF I_OFF_I 2 2nd Telephone Number Disabled
OFF I_OFF_I 3 1st Telphone Number (LINKS) Disabled
OFF I_OFF_I 4 2nd Telephone Number (LINKS) Disabled
OFF I_OFF_I 5 Alternate Communication Disabled
OFF I_OFF_I 6 to 8 for Future Use

[376] System Test Transmissions Call Directions
Default Option ON OFF
ON I_ON_I 1 1st Telephone Number Disabled
OFF I_OFF_I 2 2nd Telephone Number Disabled
OFF I_OFF_I 3 1st Telphone Number (LINKS) Disabled
OFF I_OFF_I 4 2nd Telephone Number (LINKS) Disabled
OFF I_OFF_I 5 Alternate Communication Disabled
OFF I_OFF_I 6 to 8 for Future Use

[377] Communication Variables
Default
003 I_0_I_0_I_3_I   Swinger Shutdwn (Alarms&Rest) (001-014 Trans, 000=disabled)
003 I_0_I_0_I_3_I Swinger Shutdwn (Tampers&Rest) (001-014 Trans, 000=disabled)
003 I_0_I_0_I_3_I Swinger Shutdwn (Maint&Rest) (001-014 Trans, 000=disabled)
000 I_0_I_0_I_0_I Communication Delay (001-255 seconds)
030 I_0_I_6_I_0_I AC Failure Communication Delay (001-255 minutes)
003 I_0_I_0_I_6_I TLM Trouble Delay Land Line (000-255 x 10 seconds)
030 I_0_I_3_I_0_I TLM Trouble Delay Links (000-255 x 10 seconds)
030 I_0_I_3_I_0_I Test Transmission Cycle (001-255 days; 000 to disable)
007 I_0_I_0_I_7_I Transmitter Low Battery Delay (000-255 days)
030 I_0_I_3_I_0_I Delinquency Transmission Cycle (000-255 days)
005 I_0_I_0_I_5_I Comms Cancelled Window (000-255 days)

[378] Test Transmission Time of Day
Default
9999 I_ _I_ _I_ _I_ _I   Valid entries are 0000 to 2359

[380] First Communicator Option Code
Default Option ON OFF
ON I_ON_I 1 Communications Enabled Disabled
OFF I_ON_I 2 Restorals on Bell Time-Out Restorals Follow Zones
OFF I_OFF_I 3 Pulse Dialing DTMF Dialing
ON I_ON_I 4 Switch to Pulse after 5th Attempt DTMF for All Attempts
OFF I_OFF_I 5 3rd Phone Number Enabled Disabled
OFF I_OFF_I 6 Alternate Dial 1st & 3rd Call 1st Number, Backup to 3rd
OFF I_OFF_I 7 Call Links as well as Land Line Links is Backup to Land Line
OFF I_OFF_I 8 Delinquency Follows Activity (hrs) Delinquency Follows Arming (days)

[381] Second Communicator Option Code
Default Option ON OFF
OFF I_OFF_I 1 Open after Alarm Ringback Disabled
OFF I_OFF_I 2 Open After Bell Ringback Disabled
OFF I_OFF_I 3 SIA sends Prgrmd Reports SIA sends Automatic Report Codes
OFF I_OFF_I 4 Closing Confirmation Disabled
ON I_ON_I 5 5928 Phone 1 & 3 Listen In Disabled
OFF I_OFF_I 6 5928 Phone 2 Listen In Disabled
OFF I_OFF_I 7 CID uses Pgrm’d Reports Contact ID uses Automatic Reporting
OFF I_OFF_I 8 Local Mode Enabled Disabled

[382] Third Communicator Option Code
Default Option ON OFF
OFF I_OFF_I 1 ID Partial Close Identifier is 5 Partial Closing ID is 4
OFF I_OFF_I 2 Alarm Comm during Walk Test Communications Disabled during Walk Test
ON I_ON_I 3 Communication Cancel Message Cancel Message Disabled
OFF I_OFF_I 4 Call Waiting Cancel Enabled Call Waiting Cancel Disabled
OFF I_OFF_I 5 For Future Use
OFF I_OFF_I 6 AC Fail Delay in Hours AC Fail Transmission Delay in Minutes
OFF I_OFF_I 7 For Future Use
OFF I_OFF_I 8 For Future Use

[390] Links Preamble First Telephone Number
Default
FFFF I_ _I_ _I_ _I_ _I

[391] Links Preamble Second Telephone Number
Default
FFFF I_ _I_ _I_ _I_ _I

[392] Links Preamble Third Telephone Number
Default
FFFF I_F_I_F_I_F_I_F_I

[393] Links Special Function Preamble
Default
FFFFFF I_F_I_F_I_F_I_F_I_F_I_F_I

Download Programming
[401] First Downloading Option Code
Default Option ON OFF
OFF I_ON_I 1 Downloading Enabled Disabled
ON I_ON_I 2 User Can Enable DLS Window Disabled
OFF I_OFF_I 3 Call Back Enabled Disabled
OFF I_OFF_I 4 User Initiated Call-Up Disabled
OFF I_OFF_I 5 Auto Event Buffer Upload Disabled
OFF I_OFF_I 6 to 8 For Future Use

[402] Downloading Telephone Number (32 Digits
I_L_I_E_I_A_I_V_I_E_I_ _I_B_I_L_I_A_I_N_I_K_I_ _I_ _I_ _I_ _I_ _I_ _I_ _I

[403] Downloading Access Code
Default
5020 I_5_I_0_I_2_I_0_I

[404] Panel Identification Code
Default
5020 I_5_I_0_I_2_I_0_I

[405] Answer Machine Double Call Timer
Default
060 I_0_I_4_I_0_I

[406] Number of Rings to Answer On
Default
000 I_0_I_1_I_0_I

[490] Links Preamble Download Phone Number
Default
FFFF I_ _I_ _I_ _I_ _I

[499] + Installer Code + 499 Initiate PC-Link (Local Downloading)

PGM Attributes (see the book)
Opt 1 Opt 2 Opt 3 Opt 4 Opt 5 Opt 6 Opt 7 Opt 8
[501] PGM 1 I_ _I I_ _I I_ _I I_ _I I_ _I I_ _I I_ _I I_ _I
[502] PGM 2 I_ _I I_ _I I_ _I I_ _I I_ _I I_ _I I_ _I I_ _I
[503] PGM 3 I_ _I I_ _I I_ _I I_ _I I_ _I I_ _I I_ _I I_ _I
[504] PGM 4 I_ _I I_ _I I_ _I I_ _I I_ _I I_ _I I_ _I I_ _I
[505] PGM 5 I_ _I I_ _I I_ _I I_ _I I_ _I I_ _I I_ _I I_ _I
[506] PGM 6 I_ _I I_ _I I_ _I I_ _I I_ _I I_ _I I_ _I I_ _I
[507] PGM 7 I_ _I I_ _I I_ _I I_ _I I_ _I I_ _I I_ _I I_ _I
[508] PGM 8 I_ _I I_ _I I_ _I I_ _I I_ _I I_ _I I_ _I I_ _I
[509] PGM 9 I_ _I I_ _I I_ _I I_ _I I_ _I I_ _I I_ _I I_ _I
[510] PGM 10 I_ _I I_ _I I_ _I I_ _I I_ _I I_ _I I_ _I I_ _I
[511] PGM 11 I_ _I I_ _I I_ _I I_ _I I_ _I I_ _I I_ _I I_ _I
[512] PGM 12 I_ _I I_ _I I_ _I I_ _I I_ _I I_ _I I_ _I I_ _I
[513] PGM 13 I_ _I I_ _I I_ _I I_ _I I_ _I I_ _I I_ _I I_ _I
[514] PGM 14 I_ _I I_ _I I_ _I I_ _I I_ _I I_ _I I_ _I I_ _I

PGM Partition Assignment
 Part 1   Part 2   Part 3   Part 4   Part 5   Part 6   Part 7   Part 8 
[551] PGM 1 I_ _I I_ _I I_ _I I_ _I I_ _I I_ _I I_ _I I_ _I
[552] PGM 2 I_ _I I_ _I I_ _I I_ _I I_ _I I_ _I I_ _I I_ _I
[553] PGM 3 I_ _I I_ _I I_ _I I_ _I I_ _I I_ _I I_ _I I_ _I
[554] PGM 4 I_ _I I_ _I I_ _I I_ _I I_ _I I_ _I I_ _I I_ _I
[555] PGM 5 I_ _I I_ _I I_ _I I_ _I I_ _I I_ _I I_ _I I_ _I
[556] PGM 6 I_ _I I_ _I I_ _I I_ _I I_ _I I_ _I I_ _I I_ _I
[557] PGM 7 I_ _I I_ _I I_ _I I_ _I I_ _I I_ _I I_ _I I_ _I
[558] PGM 8 I_ _I I_ _I I_ _I I_ _I I_ _I I_ _I I_ _I I_ _I
[559] PGM 9 I_ _I I_ _I I_ _I I_ _I I_ _I I_ _I I_ _I I_ _I
[560] PGM 10 I_ _I I_ _I I_ _I I_ _I I_ _I I_ _I I_ _I I_ _I
[561] PGM 11 I_ _I I_ _I I_ _I I_ _I I_ _I I_ _I I_ _I I_ _I
[562] PGM 12 I_ _I I_ _I I_ _I I_ _I I_ _I I_ _I I_ _I I_ _I
[563] PGM 13 I_ _I I_ _I I_ _I I_ _I I_ _I I_ _I I_ _I I_ _I
[564] PGM 14 I_ _I I_ _I I_ _I I_ _I I_ _I I_ _I I_ _I I_ _I
[700] Auto Clock Adjust
Default
60 I_6_I_0_I Valid entries are 0-99 seconds

[701] First International Options Code
Default Option ON OFF
OFF I_OFF_I 1 50 Hz AC 60 Hz AC
OFF I_OFF_I 2 Time Base is Internal Crystal Time Base is AC Line
OFF I_OFF_I 3 AC/DC Arming Inhibit Enabled AC/DC Arming Inhibit Disabled
OFF I_OFF_I 4 All Tampers Req. Installer Reset All Tampers Follow Restore
OFF I_OFF_I 5 6-Digit User Access Codes 4-Digit User Access Codes
OFF I_OFF_I 6 Busy Tone Detection Enabled Busy Tone Detection Disabled
OFF I_OFF_I 7 High Current Battery Charge Standard Current Battery Charge
OFF I_OFF_I 8 For Future Use

[702] Second International Options Code
Default Option ON OFF
OFF I_OFF_I 1 Pulse Dialing Make/Break Ratio 33/67 Pulse Dialing Make/Break Ratio 40/60
ON I_ON_I 2 Force Dialing Enabled Force Dialing Disabled
OFF I_OFF_I 3 Land Line Test Trans. in Mins Land Line Test Trans. in Days
OFF I_OFF_I 4 1600Hz Handshake Standard Handshake
OFF I_OFF_I 5 ID Tone Enabled ID Tone Disabled
OFF I_OFF_I 6 2100 Hz ID Tone 1300 Hz ID Tone
OFF I_OFF_I 7 One Time 1-Hr User Enabled DLS Window Full 6-Hr User Enabled DLS Window
OFF I_OFF_I 8 Bell Enabled FTC when Armed FTC Trouble Only when Armed

[703] Delay Between Dialing Attempts
Default
001 I_0_I_0_I_1_I Valid entries are 000-255 seconds

Module Programming
[801] PC5400 Printer CLICK HERE FOR PC5400 PROGRAMMING

[802] PC5908/5928 Intercom

CLICK HERE FOR PC5908/5928 PROGRAMMING

CLICK HERE FOR 2-WAY VOICE PROGRAMMING

[803] PC2150/2250 Long Range Radio or Skyroute CLICK HERE FOR SKYROUTE PROGRAMMING

[804] PC5132 Wireless Receiver (Use “ESN” Number from sticker on sensor, if only “SN” add 0 as 1st digit)

PC5132 v3.x and below use 900Mhz sensors PC5132 v4.x and above use 433Mhz sensors

All DSC Wireless sensor Serial Numbers go here EXCEPT
WLS910 Hand Held Keypad (see section 33 to 36)
WLS909 Keyfob (see section 41 to 56)

Default = 000000     (WARNING! If these sections only accept 5 digits Receiver is V2.0 or 2.1!)
[01] Zone 01 I_ _I_ _I_ _I_ _I_ _I_ _I [17] Zone 17 I_ _I_ _I_ _I_ _I_ _I_ _I
[02] Zone 02 I_ _I_ _I_ _I_ _I_ _I_ _I [18] Zone 18 I_ _I_ _I_ _I_ _I_ _I_ _I
[03] Zone 03 I_ _I_ _I_ _I_ _I_ _I_ _I [19] Zone 19 I_ _I_ _I_ _I_ _I_ _I_ _I
[04] Zone 04 I_ _I_ _I_ _I_ _I_ _I_ _I [20] Zone 20 I_ _I_ _I_ _I_ _I_ _I_ _I
[05] Zone 05 I_ _I_ _I_ _I_ _I_ _I_ _I [21] Zone 21 I_ _I_ _I_ _I_ _I_ _I_ _I
[06] Zone 06 I_ _I_ _I_ _I_ _I_ _I_ _I [22] Zone 22 I_ _I_ _I_ _I_ _I_ _I_ _I
[07] Zone 07 I_ _I_ _I_ _I_ _I_ _I_ _I [23] Zone 23 I_ _I_ _I_ _I_ _I_ _I_ _I
[08] Zone 08 I_ _I_ _I_ _I_ _I_ _I_ _I [24] Zone 24 I_ _I_ _I_ _I_ _I_ _I_ _I
[09] Zone 09 I_ _I_ _I_ _I_ _I_ _I_ _I [25] Zone 25 I_ _I_ _I_ _I_ _I_ _I_ _I
[10] Zone 10 I_ _I_ _I_ _I_ _I_ _I_ _I [26] Zone 26 I_ _I_ _I_ _I_ _I_ _I_ _I
[11] Zone 11 I_ _I_ _I_ _I_ _I_ _I_ _I [27] Zone 27 I_ _I_ _I_ _I_ _I_ _I_ _I
[12] Zone 12 I_ _I_ _I_ _I_ _I_ _I_ _I [28] Zone 28 I_ _I_ _I_ _I_ _I_ _I_ _I
[13] Zone 13 I_ _I_ _I_ _I_ _I_ _I_ _I [29] Zone 29 I_ _I_ _I_ _I_ _I_ _I_ _I
[14] Zone 14 I_ _I_ _I_ _I_ _I_ _I_ _I [30] Zone 30 I_ _I_ _I_ _I_ _I_ _I_ _I
[15] Zone 15 I_ _I_ _I_ _I_ _I_ _I_ _I [31] Zone 31 I_ _I_ _I_ _I_ _I_ _I_ _I
[16] Zone 16 I_ _I_ _I_ _I_ _I_ _I_ _I [32] Zone 32 I_ _I_ _I_ _I_ _I_ _I_ _I

Handheld Keypad Serial Numbers
Default = 000000
[33] Keypad 01 I_ _I_ _I_ _I_ _I_ _I_ _I [35] Keypad 03 I_ _I_ _I_ _I_ _I_ _I_ _I
[34] Keypad 02 I_ _I_ _I_ _I_ _I_ _I_ _I [36] Keypad 04 I_ _I_ _I_ _I_ _I_ _I_ _I

Wireless Keyfob Serial Numbers
Default = 000000
[41] Key 01 I_ _I_ _I_ _I_ _I_ _I_ _I [49] Key 09 I_ _I_ _I_ _I_ _I_ _I_ _I
[42] Key 02 I_ _I_ _I_ _I_ _I_ _I_ _I [50] Key 10 I_ _I_ _I_ _I_ _I_ _I_ _I
[43] Key 03 I_ _I_ _I_ _I_ _I_ _I_ _I [51] Key 11 I_ _I_ _I_ _I_ _I_ _I_ _I
[44] Key 04 I_ _I_ _I_ _I_ _I_ _I_ _I [52] Key 12 I_ _I_ _I_ _I_ _I_ _I_ _I
[45] Key 05 I_ _I_ _I_ _I_ _I_ _I_ _I [53] Key 13 I_ _I_ _I_ _I_ _I_ _I_ _I
[46] Key 06 I_ _I_ _I_ _I_ _I_ _I_ _I [54] Key 14 I_ _I_ _I_ _I_ _I_ _I_ _I
[47] Key 07 I_ _I_ _I_ _I_ _I_ _I_ _I [55] Key 15 I_ _I_ _I_ _I_ _I_ _I_ _I
[48] Key 08 I_ _I_ _I_ _I_ _I_ _I_ _I [56] Key 16 I_ _I_ _I_ _I_ _I_ _I_ _I

Handheld Keypad Options
Partition 1 Handheld Keypad Options (WLS910 Hand Held Keypad Button Definitions here)
[57] Func Key 1 I_ _I_ _I Func Key 3 I_ _I_ _I
Func Key 2 I_ _I_ _I Func Key 4 I_ _I_ _I

Partition 2 Handheld Keypad Options
[58] Func Key 1 I_ _I_ _I Func Key 3 I_ _I_ _I
Func Key 2 I_ _I_ _I Func Key 4 I_ _I_ _I

Wireless Keyfob Options
Partition 1 Wireless Key Options (WLS909 Keyfob Button Definitions here)
[59] Func Key 1 I_ _I_ _I Func Key 3 I_ _I_ _I
Func Key 2 I_ _I_ _I Func Key 4 I_ _I_ _I

Partition 2 Wireless Key Options
[60] Func Key 1 I_ _I_ _I Func Key 3 I_ _I_ _I
Func Key 2 I_ _I_ _I Func Key 4 I_ _I_ _I
[00] Key Not Used [16] * 0 Quick Exit
[01] For Future Use [17] * 1 Reactivate Stay/Aways
[02] For Future Use [18] For Future Use
[03] Stay Arm [19] * 7 3 Command Output 3
[04] Away Arm [20] For Future Use
[05] * 9 No-Entry Arm [21] * 7 4 Command Output 4
[06] * 4 Chime ON/OFFl [22] to [26] For Future Use
[07] * 6 —- 4 System Test [27] Disarm (OFF)
[08] to [12] For Future Use [28] Fire Alarm
[13] * 7 1 Command Output 1 [29] Aux/Medical Alarm
[14] * 7 2 Sensor Reset [30] Police Panic
[15] For Future Use
[805] PC51000 Module Programming

[806] PC5108L Module Programming

Special Installer Functions
[981] Installer Buzzer Walk Test Mode Begin/End

[902] Module Supervision Enable/Reset

[903] View Module Supervision Field

[904] Wireless Module Placement Test
Select the module / transmitter (Zones 01-32).
Press # to Cancel.
Placement Led Keypad Alpha Keypad Bell / Buzzer

Good Light 1 ON Steady GOOD 1 Beep / Squawk
Fair Light 2 ON Steady FAIR 2 Beeps / Squawks
Bad Light 3 ON Steady BAD 3 Beeps / Squawks
[906] Local Test of Downlook Remote Trigger
Enter this section to initiate a test, select one of below options

[1] Telephone Number 1 via landline   [3] Telephone Number 1 via LINKS
[2] Telephone Number 2 via landline   [4] Telephone Number 2 via LINKS
[990] Installer Lockout Enable

[991] Installer Lockout Disable

[995] Restore PC5580 Factory Default Programming 995 + Installer Code + 995

[996] Restore PC5132 Factory Default Programming 996 + Installer Code + 996

[997] Restore PC5400 Factory Default Programming 997 + Installer Code + 997

[998] Restore PC5936 Factory Default Programming 998 + Installer Code + 998

[999] Restore PC5015 Factory Default Programming 999 + Installer Code + 999

LCD Keypad Programming