DSC PC5010 / Power832 Program v2

How To Identify Largest chip on main board will show
06000464 = 5010 v1.0 06000666 = 5010 v2.0
Report Format SIA, Contact ID, 4/2, 3/1, SIA preferred
Siren Problems 1k resistor on siren outputs to prevent constant low siren sounds
Enter Program * 8 5010 (PROGRAM or SYSTEM light should flash, if long beep Code incorrect)
Exit Program #
Move to location Enter 3-digit location, some areas may require # to exit
Default Panel 1. Power down then up, if board clicks panel is locked out (replace board)
2. If no clicks jumper from ZN 1 to PGM1, power up, wait 10 seconds
Enable Download * + 6 + Master Code + 5 (Enables for 6 hours)
(System also enables downloading for 1 hour if powered down then up)
Hex Program A = * 1 * B = * 2 * C = * 3 * D = * 4 * E = * 5 * F = * 6 *

[000] Keypad Assignment (must be done at each keypad)

[0] Slot (Valid entries 0 (Global) 1 & 2 for Partition, 1-8 for Slot)
[1] Function Key 1 Assignment (Valid entries are 00-18)
[2] Function Key 2 Assignment
[3] Function Key 3 Assignment
[4] Function Key 4 Assignment
[5] Function Key 5 Assignment
00 Null Key (Not Used) 08 * 1 Bypass Mode 16 * 0 Quick Exit
01 Select Partition 1 09 * 2 Trouble Display 17 * 1 Reactivate Stay/Away’s
02 Select Partition 2 10 * 3 Alarm Memory 18 Identified Voice Prompt Help
03 Stay Arm 11 * 5 User Programming 19 * 7 3 Command Output 3
04 Away Arm 12 * 6 User Functions 20 For Future Use
05 * 9 No-Entry Arm 13 * 7 1 Utility Output 21 * 7 4 Command Output 4
06 * 4 Chime On/Off 14 * 7 2 Sensor Reset
07 * 6 4 System Test 15 General Voice Prompt Help (Voice prompts require ESCORT)
If multiple LCD keypads make 1 slot 8 to enable Zone description programming by downloading

[001] Zone 01-08 Definitions
Default Default
01 I_ _I_ _I Zone 01 05 I_ _I_ _I Zone 05
03 I_ _I_ _I Zone 02 05 I_ _I_ _I Zone 06
03 I_ _I_ _I Zone 03 05 I_ _I_ _I Zone 07
03 I_ _I_ _I Zone 04 05 I_ _I_ _I Zone 08
00 = Null Zone 09 = 24 Hr Supervisory (Links) 18 = 24hr Sprinkler
01 = Delay 1 10 = 24hr Supervisory Buzzer 19 = 24hr Water
02 = Delay 2 11 = 24hr Burglary 20 = 24hr Freeze
03 = Instant 12 = 24hr Holdup 21 = 24hr Latching Tamper
04 = Interior 13 = 24hr Gas 22 = Momentary Keyswitch Arm
05 = Interior Stay/Away 14 = 24hr Heat 23 = Maintained Keyswitch Arm
06 = Delay Stay/Away 15 = 24hr Medical 24 = Links Answer
07 = Delay 24hr Fire 16 = 24hr Panic 87 = Delay Wireless Fire
08 = Standard 24hr Fire 17 = 24 hr Emergency 88 = Standard Wireless Fire
[002] Zone 09-16 Definitions
Default Default
00 I_ _I_ _I Zone 09 00 I_ _I_ _I Zone 13
00 I_ _I_ _I Zone 10 00 I_ _I_ _I Zone 14
00 I_ _I_ _I Zone 11 00 I_ _I_ _I Zone 15
00 I_ _I_ _I Zone 12 00 I_ _I_ _I Zone 16

[003] Zone 17-24 Definitions
Default Default
00 I_ _I_ _I Zone 17 00 I_ _I_ _I Zone 21
00 I_ _I_ _I Zone 18 00 I_ _I_ _I Zone 22
00 I_ _I_ _I Zone 19 00 I_ _I_ _I Zone 23
00 I_ _I_ _I Zone 20 00 I_ _I_ _I Zone 24

[004] Zone 25-32 Definitions
Default Default
00 I_ _I_ _I Zone 25 00 I_ _I_ _I Zone 29
00 I_ _I_ _I Zone 26 00 I_ _I_ _I Zone 30
00 I_ _I_ _I Zone 27 00 I_ _I_ _I Zone 31
00 I_ _I_ _I Zone 28 00 I_ _I_ _I Zone 32

[005] System Times
Default
030 I_ _I_ _I_ _I Entry Delay 1 Enter 3 digits from [000-255]
045 I_ _I_ _I_ _I Entry Delay 2 Enter 3 digits from [000-255]
120 I_ _I_ _I_ _I Exit Delay Enter 3 digits from [000-255]
006 I_ _I_ _I_ _I Bell Cut-off Enter 3 digits from [000-255]
[006] Installer’s Code
Default
5010 I_ _I_ _I_ _I_ _I

[007] Master Code
Default
1234 I_ _I_ _I_ _I_ _I

[008] Maintenance Code
Default
AAAA I_ _I_ _I_ _I_ _I

[009] PCS5010 PGM Output Programming (PGM 1 & 2)
Default
19 I_ _I_ _I PGM 01
10 I_ _I_ _I PGM 02
Programmable Output Options

00 = Not Used 13 = Kissoff Output
01 = Burg/Fire Bell Output 14 = Ground Start Pulse
02 = For Future Use 15 = Remote Operation (DLS-1)
03 = Sensor Reset (4-wire Smokes *72) 16 = Links 1000 Support (PGM1 only)
04 = 2-Wire Smokes (PGM2 ONLY)** 17 = Stay Arm
05 = System (Parition) Armed Status 18 = Away Arm
06 = Ready To Arm 19 = * 7 1 Command Output
07 = Keypad Buzzer Follow Mode 20 = * 7 2 Command Output
08 = Courtesy Pulse (Entry/Exit time + 2 minutes) 21 = * 7 3 Command Output
09 = System Trouble Output 22 = * 7 4 Command Output
10 = Latched System Event/Strobe 23 = Silent 24-Hr (PGM2 Only)
11 = System Tamper 24 = Audible 24-Hr (PGM2 Only)
12 = TLM and Alarm
**For 2-Wire Smoke Support Jumper CON1 on board must be removed (Not available on newer panels)

[010] PC5208 PGM Output Programming (PGM 3-10)
Default Default
01 I_ _I_ _I PGM 03 01 I_ _I_ _I PGM 07
01 I_ _I_ _I PGM 04 01 I_ _I_ _I PGM 08
01 I_ _I_ _I PGM 05 01 I_ _I_ _I PGM 09
01 I_ _I_ _I PGM 06 01 I_ _I_ _I PGM 10

[011] PCS5204 PGM Output Programming (PGM 11-14)
Default Default
01 I_ _I_ _I PGM 11 01 I_ _I_ _I PGM 13
01 I_ _I_ _I PGM 12 01 I_ _I_ _I PGM 14

[012] Keypad Lockout Options
Default
000 I_0_I_0_I_0_I Number of Invalid Codes Before Lockout
000 I_0_I_0_I_0_I Lockout Duration (in minutes)

[013] First System Option Code
Default Option ON OFF
OFF I_OFF_I 1 Normally Closed Loops End-of-Line Resistors
OFF I_OFF_I 2 Double End-of-Line Resistors Single End-of-Line Resistors
ON I_ON_I 3 Panels shows trble w/Armed Panel shows Fire Trbl only w/Armed
OFF I_OFF_I 4 Tamper/Fault not show open Tampers/Fault show open
OFF I_OFF_I 5 Zone 1 is Fast Loop Zone 1 is Standard Loop
ON I_ON_I 6 Audible Exit Fault Enabled Audible Exit Fault Disabled
ON I_ON_I 7 Event Buffer follows Swinger Event Buf Logs Events Past swinger
OFF I_OFF_I 8 Temporal 3 Fire Signal Standard Pulsed Fire

[014] Second System Option Code
Default Option ON OFF
OFF I_OFF_I 1 Arm/Disarm Bell Squawk Arm/Disarm Bell Squawk disable
OFF I_OFF_I 2 Squawk ON Auto Arm No Bell Squawk
ON I_OFF_I 3 Squawk On Exit Delay No Bell Squawk
OFF I_OFF_I 4 Squawk On Entry Delay No Bell Squawk
OFF I_OFF_I 5 Squawk On Trouble No Bell Squawk
ON I_ON_I 6 Audible Exit Beeps Silent Exit Delay
OFF I_OFF_I 7 Exit Delay Termination Exit Del. Termination Disabled
OFF I_OFF_I 8 Fire Bell is Continuous Fire Bell follows Bell Cut-Off

[015] Third System Option Code
Default Option ON OFF
ON I_ON_I 1 [F] Keys Enabled Fire Keys Disabled
OFF I_ON_I 2 Panic Keys Audible Panic Keys Silent
OFF I_ON_I 3 Quick Exit Enabled Quick Exit Disabled
ON I_ON_I 4 Quick Arming Enabled Function Keys Disabled
OFF I_OFF_I 5 Code for Bypassing Code not Required
OFF I_OFF_I 6 Master Code Not Changable Master Code Changable
ON I_ON_I 7 TLM Enabled (Phone Monitor) TLM Disabled
OFF I_OFF_I 8 TLM Audible When Armed TLM Trouble Only W/Armed

[016] Fourth System Option Code
Default Option ON OFF
ON I_ON_I 1 AC Trouble Displayed AC Trouble not Displayed
OFF I_OFF_I 2 Trouble Flashes if AC Fails Trouble doesn’t follow AC
ON I_OFF_I 3 Blank KP When Not Used Keypad always Active
OFF I_OFF_I 4 Code to Stop KP Blanking No Code Required
OFF I_ON_I 5 Keypad Backlight Enabled Keypad Backlighting Disabled
OFF I_OFF_I 6 Power Save Mode Enabled Power Save Mode Disabled
OFF I_OFF_I 7 Bypass Shows while Armed Bypass doesn’t show/Armed
OFF I_OFF_I 8 Keypad Tampers enabled Keypad Tampers disabled

[020] Keypad Zone Assignments     (Keypad zones will replace regular hardwire zones)
Default
00 I_ _I_ _I Keypad (Slot 1) Zone Valid entries are 01-32
00 I_ _I_ _I Keypad (Slot 2) Zone
00 I_ _I_ _I Keypad (Slot 3) Zone First assign keypad slot in 000 section 0 (11 to 18)
00 I_ _I_ _I Keypad (Slot 4) Zone (Keypad added as 11 would be Slot 1 here, 18 is Slot 8)
00 I_ _I_ _I Keypad (Slot 5) Zone then add Zone number here in proper slot
00 I_ _I_ _I Keypad (Slot 6) Zone (Ex: Zone 07 to Keypad 12 enter 00 07 00 00 00 00 00 00)
00 I_ _I_ _I Keypad (Slot 7) Zone
00 I_ _I_ _I Keypad (Slot 8) Zone Click HERE for Keypad Zone Wiring

Zone Attributes

Opt 1 Opt 2 Opt 3 Opt 4 Opt 5 Opt 6 Opt 7 Opt 8
ON  Audible   Steady   Chime   Bypass   Force   Swinger   Tx Delay   Wireless 
OFF Silent Pulsed No No No No No No
[101] Zone 1 I_ _I I_ _I I_ _I I_ _I I_ _I I_ _I I_ _I I_ _I
To
[132] Zone 32 I_ _I I_ _I I_ _I I_ _I I_ _I I_ _I I_ _I I_ _I
[160] Maximum Dialing Attempts to Each Phone Number
Default
008 I_ _I_ _I_ _I Valid entries are 001-255 attempts (Do not enter 000)

[161] Post Dial Wait for Handshake
Default
040 I_ _I_ _I_ _I Valid entries are 001-255 seconds

[201] Partition 2 Enable
Default Option ON OFF
OFF I_OFF_I 1 Partition 2 Enabled Partition 2 Not Enabled
OFF I_OFF_I 2 To 8 Future Use

[202] Partition 1 Zone Assignments 01 to 08
Default Option ON OFF
ON I_ON_I 1 Zone 01 is on Partition 1 Zone 01 is not on Partition 1
ON I_ON_I 2 Zone 02 is on Partition 1 Zone 02 is not on Partition 1
ON I_ON_I 3 Zone 03 is on Partition 1 Zone 03 is not on Partition 1
ON I_ON_I 4 Zone 04 is on Partition 1 Zone 04 is not on Partition 1
ON I_ON_I 5 Zone 05 is on Partition 1 Zone 05 is not on Partition 1
ON I_ON_I 6 Zone 06 is on Partition 1 Zone 06 is not on Partition 1
ON I_ON_I 7 Zone 07 is on Partition 1 Zone 07 is not on Partition 1
ON I_ON_I 8 Zone 08 is on Partition 1 Zone 08 is not on Partition 1

[203] Partition 1 Zone Assignments 09 to 16
Default Option ON OFF
ON I_ON_I 1 Zone 09 is on Partition 1 Zone 09 is not on Partition 1
ON I_ON_I 2 Zone 10 is on Partition 1 Zone 10 is not on Partition 1
ON I_ON_I 3 Zone 11 is on Partition 1 Zone 11 is not on Partition 1
ON I_ON_I 4 Zone 12 is on Partition 1 Zone 12 is not on Partition 1
ON I_ON_I 5 Zone 13 is on Partition 1 Zone 13 is not on Partition 1
ON I_ON_I 6 Zone 14 is on Partition 1 Zone 14 is not on Partition 1
ON I_ON_I 7 Zone 15 is on Partition 1 Zone 15 is not on Partition 1
ON I_ON_I 8 Zone 16 is on Partition 1 Zone 16 is not on Partition 1

[204] Partition 1 Zone Assignments 17 to 24
Default Option ON OFF
ON I_ON_I 1 Zone 17 is on Partition 1 Zone 17 is not on Partition 1
ON I_ON_I 2 Zone 18 is on Partition 1 Zone 18 is not on Partition 1
ON I_ON_I 3 Zone 19 is on Partition 1 Zone 19 is not on Partition 1
ON I_ON_I 4 Zone 20 is on Partition 1 Zone 20 is not on Partition 1
ON I_ON_I 5 Zone 21 is on Partition 1 Zone 21 is not on Partition 1
ON I_ON_I 6 Zone 22 is on Partition 1 Zone 22 is not on Partition 1
ON I_ON_I 7 Zone 23 is on Partition 1 Zone 23 is not on Partition 1
ON I_ON_I 8 Zone 24 is on Partition 1 Zone 24 is not on Partition 1

[205] Partition 1 Zone Assignments 25 to 32
Default Option ON OFF
ON I_ON_I 1 Zone 25 is on Partition 1 Zone 25 is not on Partition 1
ON I_ON_I 2 Zone 26 is on Partition 1 Zone 26 is not on Partition 1
ON I_ON_I 3 Zone 27 is on Partition 1 Zone 27 is not on Partition 1
ON I_ON_I 4 Zone 28 is on Partition 1 Zone 28 is not on Partition 1
ON I_ON_I 5 Zone 29 is on Partition 1 Zone 29 is not on Partition 1
ON I_ON_I 6 Zone 30 is on Partition 1 Zone 30 is not on Partition 1
ON I_ON_I 7 Zone 31 is on Partition 1 Zone 31 is not on Partition 1
ON I_ON_I 8 Zone 32 is on Partition 1 Zone 32 is not on Partition 1

[206] Partition 2 Zone Assignments 01 to 08
Default Option ON OFF
OFF I_OFF_I 1 Zone 01 is on Partition 2 Zone 01 is not on Partition 2
OFF I_OFF_I 2 Zone 02 is on Partition 2 Zone 02 is not on Partition 2
OFF I_OFF_I 3 Zone 03 is on Partition 2 Zone 03 is not on Partition 2
OFF I_OFF_I 4 Zone 04 is on Partition 2 Zone 04 is not on Partition 2
OFF I_OFF_I 5 Zone 05 is on Partition 2 Zone 05 is not on Partition 2
OFF I_OFF_I 6 Zone 06 is on Partition 2 Zone 06 is not on Partition 2
OFF I_OFF_I 7 Zone 07 is on Partition 2 Zone 07 is not on Partition 2
OFF I_OFF_I 8 Zone 08 is on Partition 2 Zone 08 is not on Partition 2

[207] Partition 2 Zone Assignments 09 to 16
Default Option ON OFF
OFF I_OFF_I 1 Zone 09 is on Partition 2 Zone 09 is not on Partition 2
OFF I_OFF_I 2 Zone 10 is on Partition 2 Zone 10 is not on Partition 2
OFF I_OFF_I 3 Zone 11 is on Partition 2 Zone 11 is not on Partition 2
OFF I_OFF_I 4 Zone 12 is on Partition 2 Zone 12 is not on Partition 2
OFF I_OFF_I 5 Zone 13 is on Partition 2 Zone 13 is not on Partition 2
OFF I_OFF_I 6 Zone 14 is on Partition 2 Zone 14 is not on Partition 2
OFF I_OFF_I 7 Zone 15 is on Partition 2 Zone 15 is not on Partition 2
OFF I_OFF_I 8 Zone 16 is on Partition 2 Zone 16 is not on Partition 2

[208] Partition 2 Zone Assignments 17 to 24
Default Option ON OFF
OFF I_OFF_I 1 Zone 17 is on Partition 2 Zone 17 is not on Partition 2
OFF I_OFF_I 2 Zone 18 is on Partition 2 Zone 18 is not on Partition 2
OFF I_OFF_I 3 Zone 19 is on Partition 2 Zone 19 is not on Partition 2
OFF I_OFF_I 4 Zone 20 is on Partition 2 Zone 20 is not on Partition 2
OFF I_OFF_I 5 Zone 21 is on Partition 2 Zone 21 is not on Partition 2
OFF I_OFF_I 6 Zone 22 is on Partition 2 Zone 22 is not on Partition 2
OFF I_OFF_I 7 Zone 23 is on Partition 2 Zone 23 is not on Partition 2
OFF I_OFF_I 8 Zone 24 is on Partition 2 Zone 24 is not on Partition 2

[209] Partition 2 Zone Assignments 25 to 32
Default Option ON OFF
ON I_ON_I 1 Zone 25 is on Partition 2 Zone 25 is not on Partition 2
ON I_ON_I 2 Zone 26 is on Partition 2 Zone 26 is not on Partition 2
ON I_ON_I 3 Zone 27 is on Partition 2 Zone 27 is not on Partition 2
ON I_ON_I 4 Zone 28 is on Partition 2 Zone 28 is not on Partition 2
ON I_ON_I 5 Zone 29 is on Partition 2 Zone 29 is not on Partition 2
ON I_ON_I 6 Zone 30 is on Partition 2 Zone 30 is not on Partition 2
ON I_ON_I 7 Zone 31 is on Partition 2 Zone 31 is not on Partition 2
ON I_ON_I 8 Zone 32 is on Partition 2 Zone 32 is not on Partition 2

Communicator Programming
[301] First Telephone Number (32 Digits)
I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I
*2 = * *3 = # *4 = Wait for Dial Tone *5 = 2 Sec Pause *6 = End Number
(If adding more than one hex digit Example: *555* gives 3 2-second pauses)

[302] Second Telephone Number (32 Digits)
I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I
If Pager program Number + pauses *5555* gives 4 2-second pauses
Pager will not send properly if Hex Characters A C D F are in Account Number

[303] Third Telephone Number (32 Digits)
I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I

[310] Partition 1 Account Identifier Code (4 Digits)
I_ _I_ _I_ _I_ _I
If SIA enter 0 if any 0 in Account Number
If 4/2 or Contact ID use *1* for any 0 in Account Number
Pager will not send properly if Hex Characters A C D F are in Account Number

[311] Partition 2 Account Identifier Code (4 Digits)
I_ _I_ _I_ _I_ _I

[320] Alarm Report Codes Zone 01 to 08
Default Default
FF I_F_I_F_I Zone 01 Alarm FF I_F_I_F_I Zone 05 Alarm
FF I_F_I_F_I Zone 02 Alarm FF I_F_I_F_I Zone 06 Alarm
FF I_F_I_F_I Zone 03 Alarm FF I_F_I_F_I Zone 07 Alarm
FF I_F_I_F_I Zone 04 Alarm FF I_F_I_F_I Zone 08 Alarm

[321] Alarm Report Codes Zone 09 to 16
Default Default
FF I_F_I_F_I Zone 09 Alarm FF I_F_I_F_I Zone 13 Alarm
FF I_F_I_F_I Zone 10 Alarm FF I_F_I_F_I Zone 14 Alarm
FF I_F_I_F_I Zone 11 Alarm FF I_F_I_F_I Zone 15 Alarm
FF I_F_I_F_I Zone 12 Alarm FF I_F_I_F_I Zone 16 Alarm

[322] Alarm Report Codes Zone 17 to 24
Default Default
FF I_F_I_F_I Zone 17 Alarm FF I_F_I_F_I Zone 21 Alarm
FF I_F_I_F_I Zone 18 Alarm FF I_F_I_F_I Zone 22 Alarm
FF I_F_I_F_I Zone 19 Alarm FF I_F_I_F_I Zone 23 Alarm
FF I_F_I_F_I Zone 20 Alarm FF I_F_I_F_I Zone 24 Alarm

[323] Alarm Report Codes Zone 25 to 32
Default Default
FF I_F_I_F_I Zone 25 Alarm FF I_F_I_F_I Zone 29 Alarm
FF I_F_I_F_I Zone 26 Alarm FF I_F_I_F_I Zone 30 Alarm
FF I_F_I_F_I Zone 27 Alarm FF I_F_I_F_I Zone 31 Alarm
FF I_F_I_F_I Zone 28 Alarm FF I_F_I_F_I Zone 32 Alarm

[324] Alarm Restoral Report Codes Zones 01 to 08
Default Default
FF I_F_I_F_I Zone 01 Restoral FF I_F_I_F_I Zone 05 Restoral
FF I_F_I_F_I Zone 02 Restoral FF I_F_I_F_I Zone 06 Restoral
FF I_F_I_F_I Zone 03 Restoral FF I_F_I_F_I Zone 07 Restoral
FF I_F_I_F_I Zone 04 Restoral FF I_F_I_F_I Zone 08 Restoral

[325] Alarm Restoral Report Codes Zone 09 to 16
Default Default
FF I_F_I_F_I Zone 09 Restoral FF I_F_I_F_I Zone 13 Restoral
FF I_F_I_F_I Zone 10 Restoral FF I_F_I_F_I Zone 14 Restoral
FF I_F_I_F_I Zone 11 Restoral FF I_F_I_F_I Zone 15 Restoral
FF I_F_I_F_I Zone 12 Restoral FF I_F_I_F_I Zone 16 Restoral

[326] Alarm Restoral Report Codes Zone 17 to 24
Default Default
FF I_F_I_F_I Zone 17 Restoral FF I_F_I_F_I Zone 21 Restoral
FF I_F_I_F_I Zone 18 Restoral FF I_F_I_F_I Zone 22 Restoral
FF I_F_I_F_I Zone 19 Restoral FF I_F_I_F_I Zone 23 Restoral
FF I_F_I_F_I Zone 20 Restoral FF I_F_I_F_I Zone 24 Restoral

[327] Alarm Restoral Report Codes Zone 25 to 32
Default Default
FF I_F_I_F_I Zone 25 Restoral FF I_F_I_F_I Zone 29 Restoral
FF I_F_I_F_I Zone 26 Restoral FF I_F_I_F_I Zone 30 Restoral
FF I_F_I_F_I Zone 27 Restoral FF I_F_I_F_I Zone 31 Restoral
FF I_F_I_F_I Zone 28 Restoral FF I_F_I_F_I Zone 32 Restoral

[328] Miscellaneous Alarm Reporting Codes
Default Default
FF I_F_I_F_I Duress FF I_F_I_F_I Zone Expander Supervisory Alarm
FF I_F_I_F_I Opening After Alarm (Cancel) FF I_F_I_F_I Zone Expander Supervisory Restore
FF I_F_I_F_I Recent Closing (Exit Alarm) FF I_F_I_F_I Cross Zone Police Alarm

[329] Priority Alarm and Restoral
Default Default
FF I_F_I_F_I Keypad Fire Alarm FF I_F_I_F_I Keypad Fire Restoral
FF I_F_I_F_I Keypad Aux (Medical) Alarm FF I_F_I_F_I Keypad Aux (Medical) Restoral
FF I_F_I_F_I Keypad Panic Alarm FF I_F_I_F_I Keypad Panic Alarm
FF I_F_I_F_I PGM2 / 2-Wire Smoke Alarm FF I_F_I_F_I PGM2 / 2-Wire Smoke Restoral

[330] Tamper Reporting Codes Zones 01 to 08
Default Default
FF I_F_I_F_I Zone 01 Tamper FF I_F_I_F_I Zone 05 Tamper
FF I_F_I_F_I Zone 02 Tamper FF I_F_I_F_I Zone 06 Tamper
FF I_F_I_F_I Zone 03 Tamper FF I_F_I_F_I Zone 07 Tamper
FF I_F_I_F_I Zone 04 Tamper FF I_F_I_F_I Zone 08 Tamper

[331] Tamper Report Codes Zone 09 to 16 (PC580 v2.3 only)
Default Default
FF I_F_I_F_I Zone 09 Tamper FF I_F_I_F_I Zone 13 Tamper
FF I_F_I_F_I Zone 10 Tamper FF I_F_I_F_I Zone 14 Tamper
FF I_F_I_F_I Zone 11 Tamper FF I_F_I_F_I Zone 15 Tamper
FF I_F_I_F_I Zone 12 Tamper FF I_F_I_F_I Zone 16 Tamper

[332] Tamper Report Codes Zone 17 to 24
Default Default
FF I_F_I_F_I Zone 17 Tamper FF I_F_I_F_I Zone 21 Tamper
FF I_F_I_F_I Zone 18 Tamper FF I_F_I_F_I Zone 22 Tamper
FF I_F_I_F_I Zone 19 Tamper FF I_F_I_F_I Zone 23 Tamper
FF I_F_I_F_I Zone 20 Tamper FF I_F_I_F_I Zone 24 Tamper

[333] Tamper Report Codes Zone 25 to 32
Default Default
FF I_F_I_F_I Zone 25 Tamper FF I_F_I_F_I Zone 29 Tamper
FF I_F_I_F_I Zone 26 Tamper FF I_F_I_F_I Zone 30 Tamper
FF I_F_I_F_I Zone 27 Tamper FF I_F_I_F_I Zone 31 Tamper
FF I_F_I_F_I Zone 28 Tamper FF I_F_I_F_I Zone 32 Tamper

[334] Tamper Restoral Reporting Codes Zones 01 to 08
Default Default
FF I_F_I_F_I Zone 01 Tamper Restoral FF I_F_I_F_I Zone 05 Tamper Restoral
FF I_F_I_F_I Zone 02 Tamper Restoral FF I_F_I_F_I Zone 06 Tamper Restoral
FF I_F_I_F_I Zone 03 Tamper Restoral FF I_F_I_F_I Zone 07 Tamper Restoral
FF I_F_I_F_I Zone 04 Tamper Restoral FF I_F_I_F_I Zone 08 Tamper Restoral

[335] Tamper Restoral Report Codes Zone 09 to 16
Default Default
FF I_F_I_F_I Zone 09 Tamper Restoral FF I_F_I_F_I Zone 13 Tamper Restoral
FF I_F_I_F_I Zone 10 Tamper Restoral FF I_F_I_F_I Zone 14 Tamper Restoral
FF I_F_I_F_I Zone 11 Tamper Restoral FF I_F_I_F_I Zone 15 Tamper Restoral
FF I_F_I_F_I Zone 12 Tamper Restoral FF I_F_I_F_I Zone 16 Tamper Restoral

[336] Tamper Restoral Report Codes Zone 17 to 24
Default Default
FF I_F_I_F_I Zone 17 Tamper Restoral FF I_F_I_F_I Zone 21 Tamper Restoral
FF I_F_I_F_I Zone 18 Tamper Restoral FF I_F_I_F_I Zone 22 Tamper Restoral
FF I_F_I_F_I Zone 19 Tamper Restoral FF I_F_I_F_I Zone 23 Tamper Restoral
FF I_F_I_F_I Zone 20 Tamper Restoral FF I_F_I_F_I Zone 24 Tamper Restoral

[337] Tamper Restoral Report Codes Zone 25 to 32
Default Default
FF I_F_I_F_I Zone 25 Tamper Restoral FF I_F_I_F_I Zone 29 Tamper Restoral
FF I_F_I_F_I Zone 26 Tamper Restoral FF I_F_I_F_I Zone 30 Tamper Restoral
FF I_F_I_F_I Zone 27 Tamper Restoral FF I_F_I_F_I Zone 31 Tamper Restoral
FF I_F_I_F_I Zone 28 Tamper Restoral FF I_F_I_F_I Zone 32 Tamper Restoral

[338] Miscellaneous Tamper Reporting Codes
Default
FF I_F_I_F_I General System Tamper
FF I_F_I_F_I General System Tamper Restoral
FF I_F_I_F_I Keypad Lockout

[339] Closing (Arming) Reporting Codes Access Codes 01 to 08
Default Default
FF I_F_I_F_I User Code 01 Closing FF I_F_I_F_I User Code 05 Closing
FF I_F_I_F_I User Code 02 Closing FF I_F_I_F_I User Code 06 Closing
FF I_F_I_F_I User Code 03 Closing FF I_F_I_F_I User Code 07 Closing
FF I_F_I_F_I User Code 04 Closing FF I_F_I_F_I User Code 08 Closing

[340] Closing (Arming) Reporting Codes Access Codes 09 to 16
Default Default
FF I_F_I_F_I User Code 09 Closing FF I_F_I_F_I User Code 13 Closing
FF I_F_I_F_I User Code 10 Closing FF I_F_I_F_I User Code 14 Closing
FF I_F_I_F_I User Code 11 Closing FF I_F_I_F_I User Code 15 Closing
FF I_F_I_F_I User Code 12 Closing FF I_F_I_F_I User Code 16 Closing

[341] Closing (Arming) Reporting Codes Access Codes 17 to 24
Default Default
FF I_F_I_F_I User Code 17 Closing FF I_F_I_F_I User Code 21 Closing
FF I_F_I_F_I User Code 18 Closing FF I_F_I_F_I User Code 22 Closing
FF I_F_I_F_I User Code 19 Closing FF I_F_I_F_I User Code 23 Closing
FF I_F_I_F_I User Code 20 Closing FF I_F_I_F_I User Code 24 Closing

[342] Closing (Arming) Reporting Codes Access Codes 25 to 32
Default Default
FF I_F_I_F_I User Code 25 Closing FF I_F_I_F_I User Code 29 Closing
FF I_F_I_F_I User Code 26 Closing FF I_F_I_F_I User Code 30 Closing
FF I_F_I_F_I User Code 27 Closing FF I_F_I_F_I User Code 31 Closing
FF I_F_I_F_I User Code 28 Closing FF I_F_I_F_I User Code 32 Closing

[343] Miscellaneous Closing (Arming) Reporting Codes
Default Default
FF I_F_I_F_I User Code 33 Closing FF I_F_I_F_I Master Code 42 Closing
FF I_F_I_F_I User Code 34 Closing FF I_F_I_F_I Partial Closing
FF I_F_I_F_I Master Code 40 Closing FF I_F_I_F_I Special Closing
FF I_F_I_F_I Master Code 41 Closing

[344] Opening (Disarming) Reporting Codes Access Codes 01 to 08
Default Default
FF I_F_I_F_I User Code 01 Opening FF I_F_I_F_I User Code 05 Opening
FF I_F_I_F_I User Code 02 Opening FF I_F_I_F_I User Code 06 Opening
FF I_F_I_F_I User Code 03 Opening FF I_F_I_F_I User Code 07 Opening
FF I_F_I_F_I User Code 04 Opening FF I_F_I_F_I User Code 08 Opening

[345] Opening (Disarming) Reporting Codes Access Codes 09 to 16
Default Default
FF I_F_I_F_I User Code 09 Opening FF I_F_I_F_I User Code 13 Opening
FF I_F_I_F_I User Code 10 Opening FF I_F_I_F_I User Code 14 Opening
FF I_F_I_F_I User Code 11 Opening FF I_F_I_F_I User Code 15 Opening
FF I_F_I_F_I User Code 12 Opening FF I_F_I_F_I User Code 16 Opening

[346] Opening (Disarming) Reporting Codes Access Codes 17 to 24
Default Default
FF I_F_I_F_I User Code 17 Opening FF I_F_I_F_I User Code 21 Opening
FF I_F_I_F_I User Code 18 Opening FF I_F_I_F_I User Code 22 Opening
FF I_F_I_F_I User Code 19 Opening FF I_F_I_F_I User Code 23 Opening
FF I_F_I_F_I User Code 20 Opening FF I_F_I_F_I User Code 24 Opening

[347] Opening (Disarming) Reporting Codes Access Codes 25 to 32
Default Default
FF I_F_I_F_I User Code 25 Opening FF I_F_I_F_I User Code 29 Opening
FF I_F_I_F_I User Code 26 Opening FF I_F_I_F_I User Code 30 Opening
FF I_F_I_F_I User Code 27 Opening FF I_F_I_F_I User Code 31 Opening
FF I_F_I_F_I User Code 28 Opening FF I_F_I_F_I User Code 32 Opening

[348] Miscellaneous Opening (Disarming) Reporting Codes
Default Default
FF I_F_I_F_I User Code 33 Opening FF I_F_I_F_I Master Code 42 Opening
FF I_F_I_F_I User Code 34 Opening FF I_F_I_F_I Auto Arm Cancellation
FF I_F_I_F_I Master Code 40 Opening FF I_F_I_F_I Special Opening
FF I_F_I_F_I Master Code 41 Opening

[349] Maintenance Alarm Reporting Codes
Default Default
FF I_F_I_F_I Battery Trouble FF I_F_I_F_I Auxiliary Power Supply Trouble
FF I_F_I_F_I AC Failure Trouble FF I_F_I_F_I TLM Trouble (via LINKS)
FF I_F_I_F_I Bell Circuit Trouble FF I_F_I_F_I General System Trouble
FF I_F_I_F_I Fire Trouble Alarm FF I_F_I_F_I General System Supervisory

[350] Maintenance Restoral Reporting Codes
Default Default
FF I_F_I_F_I Battery Trouble Restoral FF I_F_I_F_I Auxiliary Power Supply Restoral
FF I_F_I_F_I AC Failure Trouble Restoral FF I_F_I_F_I TLM Trouble Restoral
FF I_F_I_F_I Bell Circuit Trouble Restoral FF I_F_I_F_I General System Trouble Restoral
FF I_F_I_F_I Fire Trouble Alarm Restoral FF I_F_I_F_I General System Superv. Restoral

[351] Miscellaneous Maintenance Report Codes
Default Default
FF I_F_I_F_I Phone Number 1 FTC FF I_F_I_F_I DLS Lead OUT
FF I_F_I_F_I Phone Number 1 FTC Restoral FF I_F_I_F_I General Zone Trouble Alarm
FF I_F_I_F_I Event Buffer 75% Full FF I_F_I_F_I General Zone Trouble Restoral
FF I_F_I_F_I DLS Lead IN FF I_F_I_F_I Delinquency Code

[352] Test Transmission Report Codes
Default Default
FF I_F_I_F_I Periodic Test Transmission FF I_F_I_F_I LINKS 1000 Test Transmission Code
FF I_F_I_F_I System Test

[353] Wireless Maintenance Report Codes
Default
FF I_F_I_F_I General Zone Low Battery
FF I_F_I_F_I General Zone Low Battery Restoral

[360] Communicator Format Options
Default
02 I_0_I_4_I 1st & 3rd Phone Number
01 = 4/2 20BPS 1400HZ 04 = SIA FSK
02 = 4/2 20BPS 2300HZ 05 = Pager
03 = Contact ID
02 I_0_I_5_I 2nd Phone Number

[361] Partition 1 Alarms and Restorals Call Directions
Default Option ON OFF
ON I_ON_I 1 1st Telephone # Disabled
OFF I_OFF_I 2 2nd Telephone # Disabled
OFF I_OFF_I 3 1st Telphone # (LINKS) Disabled
OFF I_OFF_I 4 2nd Telephone # (LINKS) Disabled
OFF I_OFF_I 5 to 8 for Future Use

[362] Partition 2 Alarms and Restorals Call Directions
Default Option ON OFF
ON I_ON_I 1 1st Telephone # Disabled
OFF I_OFF_I 2 2nd Telephone # Disabled
OFF I_OFF_I 3 1st Telphone # (LINKS) Disabled
OFF I_OFF_I 4 2nd Telephone # (LINKS) Disabled
OFF I_OFF_I 5 to 8 for Future Use

[363] Partition 1 Tampers and Restorals Call Directions
Default Option ON OFF
ON I_ON_I 1 1st Telephone # Disabled
OFF I_OFF_I 2 2nd Telephone # Disabled
OFF I_OFF_I 3 1st Telphone # (LINKS) Disabled
OFF I_OFF_I 4 2nd Telephone # (LINKS) Disabled
OFF I_OFF_I 5 to 8 for Future Use

[364] Partition 2 Tampers and Restorals Call Directions
Default Option ON OFF
ON I_ON_I 1 1st Telephone # Disabled
OFF I_OFF_I 2 2nd Telephone # Disabled
OFF I_OFF_I 3 1st Telphone # (LINKS) Disabled
OFF I_OFF_I 4 2nd Telephone # (LINKS) Disabled
OFF I_OFF_I 5 to 8 for Future Use

[365] Partition 1 Openings and Closings Call Directions
Default Option ON OFF
ON I_OFF_I 1 1st Telephone # Disabled
OFF I_OFF_I 2 2nd Telephone # Disabled
OFF I_OFF_I 3 1st Telphone # (LINKS) Disabled
OFF I_OFF_I 4 2nd Telephone # (LINKS) Disabled
OFF I_OFF_I 5 to 8 for Future Use

[366] Partition 2 Openings and Closings Call Directions
Default Option ON OFF
ON I_OFF_I 1 1st Telephone # Disabled
OFF I_OFF_I 2 2nd Telephone # Disabled
OFF I_OFF_I 3 1st Telphone # (LINKS) Disabled
OFF I_OFF_I 4 2nd Telephone # (LINKS) Disabled
OFF I_OFF_I 5 to 8 for Future Use

[367] System Maintenance Alarms and Restorals Call Directions
Default Option ON OFF
ON I_ON_I 1 1st Telephone # Disabled
OFF I_OFF_I 2 2nd Telephone # Disabled
OFF I_OFF_I 3 1st Telphone # (LINKS) Disabled
OFF I_OFF_I 4 2nd Telephone # (LINKS) Disabled
OFF I_OFF_I 5 to 8 for Future Use

[368] System Test Transmissions Call Directions
Default Option ON OFF
ON I_ON_I 1 1st Telephone # Disabled
OFF I_OFF_I 2 2nd Telephone # Disabled
OFF I_OFF_I 3 1st Telphone # (LINKS) Disabled
OFF I_OFF_I 4 2nd Telephone # (LINKS) Disabled
OFF I_OFF_I 5 to 8 for Future Use

[370] Communication Variables
Default
003 I_0_I_0_I_3_I Swinger (Alarms&Rest) (001-014 Trans, 000=disabled)
003 I_0_I_0_I_3_I Swinger (Tampers&Rest) (001-014 Trans, 000=disabled)
003 I_0_I_0_I_3_I Swinger (Maint&Rest) (001-014 Trans, 000=disabled)
000 I_0_I_0_I_0_I Communication Delay (001-255 seconds)
030 I_0_I_6_I_0_I AC Fail Comm Delay (001-255 minutes)
003 I_0_I_0_I_6_I TLM Trble Delay Land Line (No. of valid checks required – 000-255 x 10s)
030 I_0_I_3_I_0_I TLM Trble Delay Links (No. of valid checks required – 000-255 x 10s)
030 I_0_I_3_I_0_I Test Transmission Cycle (001-255 days; 000 to disable)
007 I_0_I_0_I_7_I Transmitter Low Batt Delay (000-255 days)
030 I_0_I_3_I_0_I Delinquency xmission Cycle (000-255 days)

[371] Test Transmission Time of Day
Default
9999 I_ _I_ _I_ _I_ _I     Valid entries are 0000 to 2359

[380] First Communicator Option Code
Default Option ON OFF
ON I_ON_I 1 Communications Enabled Disabled
OFF I_ON_I 2 Restorals on Bell Time-Out Restorals Follow Zones
OFF I_OFF_I 3 Pulse Dialing DTMF Dialing
ON I_ON_I 4 Pulse after 5th Attempt DTMF for All Attempts
OFF I_OFF_I 5 3rd Phone Number Enabled Disabled
OFF I_OFF_I 6 Alternate Dial 1st & 3rd Call 1st Number, Backup to 3rd
OFF I_OFF_I 7 Call Links and Land Line Links is Backup to Land Line
OFF I_OFF_I 8 Delinquency Follow Actvty (Hrs) Delinquency Follows Arming (Days)

[381] Second Communicator Option Code
Default Option ON OFF
OFF I_OFF_I 1 Open after Alarm Ringback Disabled
OFF I_OFF_I 2 Open After Bell Ringback Disabled
OFF I_OFF_I 3 SIA sends Prgrmd Reports SIA sends Automatic Report Codes
OFF I_OFF_I 4 Closing Confirmation Disabled
ON I_ON_I 5 5928 Phone 1 & 3 Listen In Disabled
OFF I_OFF_I 6 5928 Phone 2 Listen In Disabled
OFF I_OFF_I 7 to 8 For Future Use

[390] Links Preamble First Telephone Number
Default
FFFF I_ _I_ _I_ _I_ _I

[391] Links Preamble Second Telephone Number
Default
FFFF I_ _I_ _I_ _I_ _I

[392] Links Preamble Third Telephone Number
Default
FFFF I_F_I_F_I_F_I_F_I

[393] Links Special Function Preamble
Default
FFFF I_F_I_F_I_F_I_F_I

Download Programming
[401] First Downloading Option Code
Default Option ON OFF
OFF I_ON_I 1 Downloading Enabled Disabled
ON I_ON_I 2 User Can Enable DLS Window Disabled
OFF I_OFF_I 3 Call Back Enabled Disabled
OFF I_OFF_I 4 User Initiated Call-Up Enabled Disabled
OFF I_OFF_I 5 to 8 For Future Use

[402] Downloading Telephone Number (32 Digits)
I_L_I_E_I_A_I_V_I_E_I_ _I_B_I_L_I_A_I_N_I_K_I_ _I_ _I_ _I_ _I_ _I_ _I_ _I

[403] Downloading Access Code
Default
5010 I_5_I_0_I_1_I_0_I

[404] Panel Identification Code
Default
5010 I_5_I_0_I_1_I_0_I

[405] Answer Machine Double Call Timer
Default
060 I_0_I_4_I_0_I

[406] Number of Rings to Answer On
Default
000 I_0_I_1_I_0_I

[490] Links Preamble Download Phone Number
Default
FFFF I_F_I_F_I_F_I_F_I

[499] + Installer Code + 499 Initiate PC-Link (Local Downloading)

Module Programming

[801] PC5400 Printer Module

[802] PC5908/5928 Intercom Module

[803] PC2150/2250 Long Range Radio or Skyroute

[804] PC5132 Wireless Receiver (Use “ESN” Number from sticker on sensor, if only “SN” add 0 as 1st digit)
PC5132 v3.x and below use 900Mhz sensors PC5132 v4.x and above use 433Mhz sensors

All DSC Wireless sensor Serial Numbers go here EXCEPT
WLS910 Hand Held Keypad (see section 33 to 36)
WLS909 Keyfob (see section 41 to 56)

Default = 000000     (WARNING! If these sections only accept 5 digits Receiver is V2.0 or 2.1!)
[01] Zone 01 I_ _I_ _I_ _I_ _I_ _I_ _I [17] Zone 17 I_ _I_ _I_ _I_ _I_ _I_ _I
[02] Zone 02 I_ _I_ _I_ _I_ _I_ _I_ _I [18] Zone 18 I_ _I_ _I_ _I_ _I_ _I_ _I
[03] Zone 03 I_ _I_ _I_ _I_ _I_ _I_ _I [19] Zone 19 I_ _I_ _I_ _I_ _I_ _I_ _I
[04] Zone 04 I_ _I_ _I_ _I_ _I_ _I_ _I [20] Zone 20 I_ _I_ _I_ _I_ _I_ _I_ _I
[05] Zone 05 I_ _I_ _I_ _I_ _I_ _I_ _I [21] Zone 21 I_ _I_ _I_ _I_ _I_ _I_ _I
[06] Zone 06 I_ _I_ _I_ _I_ _I_ _I_ _I [22] Zone 22 I_ _I_ _I_ _I_ _I_ _I_ _I
[07] Zone 07 I_ _I_ _I_ _I_ _I_ _I_ _I [23] Zone 23 I_ _I_ _I_ _I_ _I_ _I_ _I
[08] Zone 08 I_ _I_ _I_ _I_ _I_ _I_ _I [24] Zone 24 I_ _I_ _I_ _I_ _I_ _I_ _I
[09] Zone 09 I_ _I_ _I_ _I_ _I_ _I_ _I [25] Zone 25 I_ _I_ _I_ _I_ _I_ _I_ _I
[10] Zone 10 I_ _I_ _I_ _I_ _I_ _I_ _I [26] Zone 26 I_ _I_ _I_ _I_ _I_ _I_ _I
[11] Zone 11 I_ _I_ _I_ _I_ _I_ _I_ _I [27] Zone 27 I_ _I_ _I_ _I_ _I_ _I_ _I
[12] Zone 12 I_ _I_ _I_ _I_ _I_ _I_ _I [28] Zone 28 I_ _I_ _I_ _I_ _I_ _I_ _I
[13] Zone 13 I_ _I_ _I_ _I_ _I_ _I_ _I [29] Zone 29 I_ _I_ _I_ _I_ _I_ _I_ _I
[14] Zone 14 I_ _I_ _I_ _I_ _I_ _I_ _I [30] Zone 30 I_ _I_ _I_ _I_ _I_ _I_ _I
[15] Zone 15 I_ _I_ _I_ _I_ _I_ _I_ _I [31] Zone 31 I_ _I_ _I_ _I_ _I_ _I_ _I
[16] Zone 16 I_ _I_ _I_ _I_ _I_ _I_ _I [32] Zone 32 I_ _I_ _I_ _I_ _I_ _I_ _I

Handheld Keypad Serial Numbers
Default = 000000
[33] Keypad 01 I_ _I_ _I_ _I_ _I_ _I_ _I [35] Keypad 03 I_ _I_ _I_ _I_ _I_ _I_ _I
[34] Keypad 02 I_ _I_ _I_ _I_ _I_ _I_ _I [36] Keypad 04 I_ _I_ _I_ _I_ _I_ _I_ _I

Wireless Keyfob Serial Numbers
Default = 000000
[41] Key 01 I_ _I_ _I_ _I_ _I_ _I_ _I [49] Key 09 I_ _I_ _I_ _I_ _I_ _I_ _I
[42] Key 02 I_ _I_ _I_ _I_ _I_ _I_ _I [50] Key 10 I_ _I_ _I_ _I_ _I_ _I_ _I
[43] Key 03 I_ _I_ _I_ _I_ _I_ _I_ _I [51] Key 11 I_ _I_ _I_ _I_ _I_ _I_ _I
[44] Key 04 I_ _I_ _I_ _I_ _I_ _I_ _I [52] Key 12 I_ _I_ _I_ _I_ _I_ _I_ _I
[45] Key 05 I_ _I_ _I_ _I_ _I_ _I_ _I [53] Key 13 I_ _I_ _I_ _I_ _I_ _I_ _I
[46] Key 06 I_ _I_ _I_ _I_ _I_ _I_ _I [54] Key 14 I_ _I_ _I_ _I_ _I_ _I_ _I
[47] Key 07 I_ _I_ _I_ _I_ _I_ _I_ _I [55] Key 15 I_ _I_ _I_ _I_ _I_ _I_ _I
[48] Key 08 I_ _I_ _I_ _I_ _I_ _I_ _I [56] Key 16 I_ _I_ _I_ _I_ _I_ _I_ _I

Handheld Keypad Options
Partition 1 Handheld Keypad Options (WLS910 Hand Held Keypad Button Definitions here)
[57] Func Key 1 I_ _I_ _I Func Key 3 I_ _I_ _I
Func Key 2 I_ _I_ _I Func Key 4 I_ _I_ _I

Partition 2 Handheld Keypad Options
[58] Func Key 1 I_ _I_ _I Func Key 3 I_ _I_ _I
Func Key 2 I_ _I_ _I Func Key 4 I_ _I_ _I

Wireless Keyfob Options
Partition 1 Wireless Key Options (WLS909 Keyfob Button Definitions here)
[59] Func Key 1 I_ _I_ _I Func Key 3 I_ _I_ _I
Func Key 2 I_ _I_ _I Func Key 4 I_ _I_ _I

Partition 2 Wireless Key Options
[60] Func Key 1 I_ _I_ _I Func Key 3 I_ _I_ _I
Func Key 2 I_ _I_ _I Func Key 4 I_ _I_ _I


[00] Key Not Used [16] * 0 Quick Exit
[01] For Future Use [17] * 1 Reactivate Stay/Aways
[02] For Future Use [18] For Future Use
[03] Stay Arm [19] * 7 3 Command Output 3
[04] Away Arm [20] For Future Use
[05] * 9 No-Entry Arm [21] * 7 4 Command Output 4
[06] * 4 Chime ON/OFFl [22] to [26] For Future Use
[07] * 6 —- 4 System Test [27] Disarm (OFF)
[08] to [12] For Future Use [28] Fire Alarm
[13] * 7 1 Command Output 1 [29] Aux/Medical Alarm
[14] * 7 2 Sensor Reset [30] Police Panic
[15] For Future Use
Special Installer Functions
[981] Installer Buzzer Walk Test Mode Begin/End
[902] Module Supervision Enable/Reset
[903] View Module Supervision Field
[904] Wireless Module Placement Test
Select the module / transmitter (Zones 01-32).
Press # to Cancel.
Placement Led Keypad Alpha Keypad Bell / Buzzer

Good Light 1 ON Steady GOOD 1 Beep / Squawk
Fair Light 2 ON Steady FAIR 2 Beeps / Squawks
Bad Light 3 ON Steady BAD 3 Beeps / Squawks
[990] Installer Lockout Enable

[991] Installer Lockout Disable

[993] Restore Links Long Range Radio Programming 993 + Installer Code + 993

[995] Restore PC5580 Factory Default Programming 995 + Installer Code + 995

[996] Restore PC5132 Factory Default Programming 996 + Installer Code + 996

[997] Restore PC5400 Factory Default Programming 997 + Installer Code + 997

[998] Restore PC5908/5928 Factory Default Programming 998 + Installer Code + 998

[999] Restore Factory Default Programming 999 + Installer Code + 999

LCD Keypad Programming