DSC PC5010 / Power 832 Program

Supported
Modules
PC5132 Wireless Receiver (v2.1 or above)
PC5400 Printer Module
PC5908/5928 Intercom
PC5580 Escort does not not work due to no partitioning (it uses WS5580 Escort)
PC5010 Keypads will not work (they might for a while but screw up later)
Report Format SIA only, hard coded into panel, report codes are pre-programmed
Siren Problems Add 1k resistor on siren outputs to prevent constant low siren sounds
Enable Download * 6 + Master Code + 5 #
Enter Program * 8 284119
Exit Program #
Move to location Enter 3-digit location, some areas require # to exit
Default Panel Connect wire from Zone 1 to PGM1, power up, wait 10 seconds

[000] Keypad Assignment
Note: This must be done at each keypad requiring supervision

[0] Slot (Address) – Valid entries are 11-18 (for Slot 11 to 18)
Note: Function Keys cannot be changed on LED or LCD Keypads

[001] Zone 01-08 Definitions
Default Default
01 I_ _I_ _I Zone 01     05 I_ _I_ _I Zone 05
03 I_ _I_ _I Zone 02 05 I_ _I_ _I Zone 06
03 I_ _I_ _I Zone 03 05 I_ _I_ _I Zone 07
03 I_ _I_ _I Zone 04 05 I_ _I_ _I Zone 08
Zone Definitions

00 Null Zone (Not Used) 09 Auto Verified 24 Hour Fire 18 24 Hour Emergency
01 Delay 1 10 24 Hour Supervisory (LINKS) 19 24 Hour Sprinkler
02 Delay 2 11 24 Hour Supervisory Buzzer 20 24 Hour Water Detector
03 Instant 12 24 Hour Burglary 21 24 Hour Freeze Warning
04 Interior 13 24 Hour Holdup 22 24 Hour Latching Tamper
05 Interior, Stay/Away 14 24 Hour Gas 23 Day Zone
06 Delay, Stay/Away 15 24 Hour High Temperature 24 LINKS Answer
07 Delay 24 Hr Fire 16 24 Hour Medical 87 Delay 24 Hr Fire (Wireless)
08 Standard 24 Hr Fire 17 24 Hour Panic 88 Standard 24 Hr Fire (Wireless)

[002] Zone 09-16 Definitions
Default Default
00 I_ _I_ _I Zone 09     00 I_ _I_ _I Zone 13
00 I_ _I_ _I Zone 10 00 I_ _I_ _I Zone 14
00 I_ _I_ _I Zone 11 00 I_ _I_ _I Zone 15
00 I_ _I_ _I Zone 12 00 I_ _I_ _I Zone 16

[003] Zone 17-24 Definitions
Default Default
00 I_ _I_ _I Zone 17 00 I_ _I_ _I Zone 21
00 I_ _I_ _I Zone 18 00 I_ _I_ _I Zone 22
00 I_ _I_ _I Zone 19 00 I_ _I_ _I Zone 23
00 I_ _I_ _I Zone 20 00 I_ _I_ _I Zone 24

[004] Zone 25-32 Definitions
Default Default
00 I_ _I_ _I Zone 25 00 I_ _I_ _I Zone 29
00 I_ _I_ _I Zone 26 00 I_ _I_ _I Zone 30
00 I_ _I_ _I Zone 27 00 I_ _I_ _I Zone 31
00 I_ _I_ _I Zone 28 00 I_ _I_ _I Zone 32

[005] System Times
Default
030 I_ _I_ _I_ _I Entry Delay 1 Enter 3 digits from [000-255]
120 I_ _I_ _I_ _I Entry Delay 2 Enter 3 digits from [000-255]
060 I_ _I_ _I_ _I Exit Delay Enter 3 digits from [000-255]
006 I_ _I_ _I_ _I Bell Cut-off Enter 3 digits from [000-255]

[006] Installer’s Code
I_2_I_8_I_4_I_1_I_1_I_9_I  Enter 6 Hexidecimal digits

[007] Master Code
Default
1234 I_ _I_ _I_ _I_ _I  Enter 4 decimal digits

[009] WSS5010 PGM Output Programming (PGM 1 & 2)
Default Default
02 I_ _I_ _I PGM 1     03 I_ _I_ _I PGM 2
00 Not used 15 Remote (DLS-1 Support)
01 Burg & Fire Bell Output 16 LINKS 1000 Support (PGM 1 only)
02 Utility Output 17 Fire Bell
03 4-Wire Smoke Reset 18 Burglary Bell
04 2-Wire Smoke (PGM2 Only) 19 Latched Strobe
05 System Armed Status 20 Latched Burglary
06 Ready To Arm 21 Latched Fire
07 KP Buzzer Follow Mode 22 Latched Panic
08 Courtesy Pulse 23 Latched Medical
09 For future use 24 Latched Supervisory
10 For future use 25 Latched Priority
11 For future use 26 Latched Holdup
12 TLM and Alarm 27 Auxiliary PGM Type 1 (ON/OFF)
13 Kissoff Output 28 Auxiliary PGM Type 1 (Pulse)
14 Ground Start Pulse 29 Auxiliary PGM Type 2 (ON/OFF)
30 Auxiliary PGM Type 2 (Pulse)

[010] WSS5208 PGM Output Programming (PGM 3-10)
Default Default
01 I_ _I_ _I PGM 3     01 I_ _I_ _I PGM 7
01 I_ _I_ _I PGM 4 01 I_ _I_ _I PGM 8
01 I_ _I_ _I PGM 5 01 I_ _I_ _I PGM 9
01 I_ _I_ _I PGM 6 01 I_ _I_ _I PGM 10

[011] WSS5204 PGM Output Programming (PGM 11-14)
Default Default
01 I_ _I_ _I PGM 11 01 I_ _I_ _I PGM 13
01 I_ _I_ _I PGM 12 01 I_ _I_ _I PGM 14

[012] Keypad Lockout Options
Default
005 I_ _I_ _I_ _I Number of Invalid Codes Before Lockout
001 I_ _I_ _I_ _I Lockout Duration (in minutes)

[013] First System Option Code
Default Option ON OFF
OFF I_ _I 1 Normally Closed Loops End-of-Line Resistors
OFF I_OFF_I   2 Double End-of-Line Resistors Single End-of-Line Resistors
ON I_ON_I 3 On-board Zones 1-4 enabled* On-board Zones 1-4 disabled*
ON I_ON_I 4 On-board Zones 5-8 enabled* On-board Zones 5-8 disabled*
OFF I_ON_I 5 TLM Enabled TLM Disabled 5.10
ON I_ON_I 6 TLM Audible When Armed TLM Trouble Only When Armed
ON I_ON_I 7 Event Buffer Follows Swinger Event Buffer Logs Events Past shutdown
OFF I_OFF_I 8 For Future Use
*On board zones (1 – 4 or 5 – 8) must be disabled if using Wireless (in blocks of 4)

[014] Second System Option Code
Default Option ON OFF
OFF I_OFF_I 1 Arm/Disarm Bell Squawk enabled Arm / Disarm Bell Squawk disabled
OFF I_OFF_I 2 Bell Squawk on Trouble No Bell Squawk on Trouble
ON I_ON_I 3 Audible Exit Beeps with Urgency Silent Exit Delay
OFF I_OFF_I 4 Exit Delay Termination Enabled Exit Delay Termination disabled
OFF I_ON_I 5 Fire Bell doesn’t follow Cut-off Fire Bell follows Bell Cut-off
ON I_ON_I 6 Bell Output Burglary enabled Bell Output Burglary disabled
ON I_ON_I 7 Bell Out Fire enabled Bell Output Fire disabled
ON I_ON_I 8 Delayed Two-Wire Smoke PGM2 Instant Two-Wire Smoke on PGM2

[015] Third System Option Code
Default Option ON OFF
ON I_ON_I 1 [F] Keys Enabled [F] Keys Disabled
ON I_ON_I 2 Quick Exit Enabled Quick Exit Disabled
ON I_ON_I 3 Arming Keys Don’t Req Code Arming Keys Require Access Code
OFF I_OFF_I 4 Master Code Not Changeable Master Code Changeable
OFF I_OFF_I 5 For Future Use
OFF I_OFF_I 6 Blank Keypad when Not Used Keypad Active
ON I_ON_I 7 Keypad Backlighting enabled Keypad Backlighting disabled
ON I_OFF_I 8 Bypass Status Display w/Armed Bypass Status Not Displayed

Zone Attributes
Opt 1 Opt 2 Opt 3 Opt 4 Opt 5 Opt 6 Opt 7 Opt 8
ON   Audible     Steady     Chime     Bypass     Force     Wireless     Tx Delay     Cross Zone  
OFF Silent Pulsed No No No No No No
[101] Zone 1 I_ _I I_ _I I_ _I I_ _I I_ _I I_ _I I_ _I I_ _I
all the way to
[132] Zone 32 I_ _I I_ _I I_ _I I_ _I I_ _I I_ _I I_ _I I_ _I

[160] Maximum Dialing Attempts to Each Phone Number
Default
008 I_ _I_ _I_ _I   Valid entries are 001-255 attempts (Do not enter 000)

[161] Post Dial Wait for Handshake
Default
040 I_ _I_ _I_ _I   Valid entries are 001-255 seconds

[162] Delay Between Dialing Attempts
Default
010 I_ _I_ _I_ _I   Valid entries are 001-255 seconds

[170] Cross Zone Timer
Default
000 I_ _I_ _I_ _I   Valid entries are 001-255 seconds

[171] Up and About Timer
Default
000 I_ _I_ _I_ _I   Valid entries are 001-255 hours

[172] WSSFOB PGM Pulse Timer
Default
005 I_ _I_ _I_ _I   Valid entries are 001-255 seconds

Communicator Programming
[301] First Telephone Number (32 Digits)
I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I
*2 = * , *3 = #, *4 = Wait for Dial Tone, *5=2 Sec Pause, *6 End Number
(If adding more than one hex digit Example: *555* gives 3 2 second pauses)

[302] Pager Telephone Number (32 Digits) add at least 4 “E”‘s after pager for proper operation
I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I
If Pager program Number + pauses *5555* gives 4 2-second pauses
Pager will not send properly if Hex Characters A C D F are in Account Number

[310] Account Number (10 digits)
I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I
* 1 * = A * 2 * = B * 3 * = C * 4 * = D * 5 * = E * 6 * = F

[360] First Telephone Number Dialing Options
Default Option ON OFF
ON I_ON_I 1 Alarms Enabled Disabled
OFF I_OFF_I 2 Alarm Restores Enabled Disabled
OFF I_OFF_I 3 Tamper Alarms Enabled Disabled
OFF I_OFF_I 4 Tamper Restores Enabled Disabled
OFF I_OFF_I 5 Openings Enabled Disabled
OFF I_OFF_I 6 Closings Enabled Disabled
ON I_ON_I 7 Maint. Alarms Enabled Disabled
OFF I_OFF_I 8 Maintenance Restore Enabled Disabled

[361] First Telephone Number LINKS Backup Dialing Options
Default Option ON OFF
OFF I_OFF_I 1 Alarms Enabled Disabled
OFF I_OFF_I 2 Alarm Restores Enabled Disabled
OFF I_OFF_I 3 Tamper Alarms Enabled Disabled
OFF I_OFF_I 4 Tamper Restores Enabled Disabled
OFF I_OFF_I 5 Openings Enabled Disabled
OFF I_OFF_I 6 Closings Enabled Disabled
OFF I_OFF_I 7 Maintenance Alarm Enabled Disabled
OFF I_OFF_I 8 Maintenance Restore Enabled Disabled

[365] Second (Pager) Telephone Number Dialing Options
Default Option ON OFF
OFF I_OFF_I 1 Closings Enabled Disabled
OFF I_OFF_I 2 Openings Enabled Disabled
OFF I_OFF_I 3 General System Event Enable Disabled
OFF I_OFF_I 4-8 For Future Use

[370] Communication Variables
Default
005 I_0_I_0_I_5_I Swinger Shutdwn (Alarms&Rest) (001-014 Trans, 000=disabled)
005 I_0_I_0_I_5_I Swinger Shutdwn (Tampers&Rest) (001-014 Trans, 000=disabled)
005 I_0_I_0_I_5_I Swinger Shutdwn (Maint&Rest) (001-014 Trans, 000=disabled)
000 I_0_I_0_I_0_I Communication Delay (001-255 seconds)
030 I_0_I_6_I_0_I AC Failure Communication Delay (001-255 minutes)
003 I_0_I_0_I_6_I TLM Trouble Delay Land Line (No. of valid checks required – 000-255 x 10s)
030 I_0_I_3_I_0_I Test Transmission Cycle (001-255 days; 000 to disable)
007 I_0_I_0_I_7_I Transmitter Low Battery Delay (000-255 days)

[380] First Communicator Option Code
Default Option ON OFF
ON I_ON_I 1 Communications Enabled Communications Disabled
ON I_OFF_I 2 Restorals on Bell Time-out Restorals Follow Zones
OFF I_OFF_I   3 Pulse Dialing DTMF Dialing
ON I_ON_I 4 Switch to Pulse 5th Attempt DTMF Dial For All Attempts
OFF I_OFF_I 5 Closing Confirmation Enable Disabled
OFF I_OFF_I 6 Partial Closings Identified Partial Closings are not Identified
OFF I_OFF_I 7-8 For Future Use

[390] LINKS Preamble (Telephone Number)
Default
FFFF I_ _I_ _I_ _I_ _I  (Program all unused digits with Hex F)

[401] First Downloading Option Code
Default Option ON OFF
ON I_ON_I 1 Double Call enabled Disabled
ON I_ON_I 2 User Call-up enabled Disabled
ON I_OFF_I 3 Call-Back Enabled Disabled
OFF I_OFF_I   4-8 For Future Use

[402] Download Telephone Number (32 Digits)
I_L_I_E_I_A_I_V_I_E_I_ _I_B_I_L_I_A_I_N_I_K_I_ _I_ _I_ _I_ _I_ _I

[403] Downloading Access Code
Default
5010 or 9524 (Consult sheet for more codes) I__I__I__I__I  Enter 4 Hexidecimal digits

[404] Number of Rings to Answer
Default
012 I_0_I_1_I_2_I  (Valid entries are 001-255 rings; 000=answer disabled)

[405] Answering Machine Double-call Timer
Default
060 I_0_I_3_I_0_I  (Valid entries are 001-255 seconds)

[490] Initiate PC-LINK (Direct Connect Local Download)
Module Programming (Many of these modules are older versions)
[801] PC5400 Printer Module Click HERE for PC5400 Programming
[802] PC5908/5928 Intercom Module Click HERE for PC5908/5928 Programming
Click HERE for 2-Way Voice Programming
[804] PC5132 v3 Wireless Receiver Click HERE for PC5132 v2.1 Programming
PC5132 v3.x and below use 900Mhz sensors PC5132 v4.x and above use 433Mhz sensors
All DSC Wireless sensor Serial Numbers go here EXCEPT
WLS910 Hand Held Keypad (see section 33 to 36)
WLS909 Keyfob (see section 41 to 56)
Zone Serial Numbers (Use “SN” Number from sticker on sensor, do not use “ESN” number)
Default = 000000

[01] Zone 01 I_ _I_ _I_ _I_ _I_ _I [17] Zone 17 I_ _I_ _I_ _I_ _I_ _I
[02] Zone 02 I_ _I_ _I_ _I_ _I_ _I [18] Zone 18 I_ _I_ _I_ _I_ _I_ _I
[03] Zone 03 I_ _I_ _I_ _I_ _I_ _I [19] Zone 19 I_ _I_ _I_ _I_ _I_ _I
[04] Zone 04 I_ _I_ _I_ _I_ _I_ _I [20] Zone 20 I_ _I_ _I_ _I_ _I_ _I
[05] Zone 05 I_ _I_ _I_ _I_ _I_ _I [21] Zone 21 I_ _I_ _I_ _I_ _I_ _I
[06] Zone 06 I_ _I_ _I_ _I_ _I_ _I [22] Zone 22 I_ _I_ _I_ _I_ _I_ _I
[07] Zone 07 I_ _I_ _I_ _I_ _I_ _I [23] Zone 23 I_ _I_ _I_ _I_ _I_ _I
[08] Zone 08 I_ _I_ _I_ _I_ _I_ _I [24] Zone 24 I_ _I_ _I_ _I_ _I_ _I
[09] Zone 09 I_ _I_ _I_ _I_ _I_ _I [25] Zone 25 I_ _I_ _I_ _I_ _I_ _I
[10] Zone 10 I_ _I_ _I_ _I_ _I_ _I [26] Zone 26 I_ _I_ _I_ _I_ _I_ _I
[11] Zone 11 I_ _I_ _I_ _I_ _I_ _I [27] Zone 27 I_ _I_ _I_ _I_ _I_ _I
[12] Zone 12 I_ _I_ _I_ _I_ _I_ _I [28] Zone 28 I_ _I_ _I_ _I_ _I_ _I
[13] Zone 13 I_ _I_ _I_ _I_ _I_ _I [29] Zone 29 I_ _I_ _I_ _I_ _I_ _I
[14] Zone 14 I_ _I_ _I_ _I_ _I_ _I [30] Zone 30 I_ _I_ _I_ _I_ _I_ _I
[15] Zone 15 I_ _I_ _I_ _I_ _I_ _I [31] Zone 31 I_ _I_ _I_ _I_ _I_ _I
[16] Zone 16 I_ _I_ _I_ _I_ _I_ _I [32] Zone 32 I_ _I_ _I_ _I_ _I_ _I

Handheld Keypad Serial Numbers
Default = 000000
[33] Keypad 01 I_ _I_ _I_ _I_ _I_ _I [35] Keypad 03 I_ _I_ _I_ _I_ _I_ _I
[34] Keypad 02 I_ _I_ _I_ _I_ _I_ _I [36] Keypad 04 I_ _I_ _I_ _I_ _I_ _I

Wireless Keyfob Serial Numbers
Default = 000000
[41] Key 01 I_ _I_ _I_ _I_ _I_ _I [49] Key 09 I_ _I_ _I_ _I_ _I_ _I
[42] Key 02 I_ _I_ _I_ _I_ _I_ _I [50] Key 10 I_ _I_ _I_ _I_ _I_ _I
[43] Key 03 I_ _I_ _I_ _I_ _I_ _I [51] Key 11 I_ _I_ _I_ _I_ _I_ _I
[44] Key 04 I_ _I_ _I_ _I_ _I_ _I [52] Key 12 I_ _I_ _I_ _I_ _I_ _I
[45] Key 05 I_ _I_ _I_ _I_ _I_ _I [53] Key 13 I_ _I_ _I_ _I_ _I_ _I
[46] Key 06 I_ _I_ _I_ _I_ _I_ _I [54] Key 14 I_ _I_ _I_ _I_ _I_ _I
[47] Key 07 I_ _I_ _I_ _I_ _I_ _I [55] Key 15 I_ _I_ _I_ _I_ _I_ _I
[48] Key 08 I_ _I_ _I_ _I_ _I_ _I [56] Key 16 I_ _I_ _I_ _I_ _I_ _I

Handheld Keypad Options
[57] Function Key 1 I_ _I_ _I [59] Function Key 3 I_ _I_ _I
[58] Function Key 2 I_ _I_ _I [60] Function Key 4 I_ _I_ _I

Wireless Key Options
[65] Function Key 1 I_ _I_ _I [67] Function Key 3 I_ _I_ _I
[66] Function Key 2 I_ _I_ _I [68] Function Key 4 I_ _I_ _I
[00] Key Not Used [16] * 0 Quick Exit
[01] For Future Use [17] * 1 Reactivate Stay/Aways
[02] For Future Use [18] For Future Use
[03] Stay Arm [19] * 7 3 Command Output 3
[04] Away Arm [20] For Future Use
[05] * 9 No-Entry Arm [21] * 7 4 Command Output 4
[06] * 4 Chime ON/OFFl [22] For Future Use
[07] * 6 — 4 System Test [23] For Future Use
[08] For Future Use [24] For Future Use
[09] For Future Use [25] For Future Use
[10] For Future Use [26] For Future Use
[11] For Future Use [27] Disarm (OFF)
[12] For Future Use [28] Fire Alarm
[13] * 7 1 Command Output 1 [29] Aux/Medical Alarm
[14] * 7 2 Sensor Reset [30] Police Panic
[15] For Future Use

Special Installer Functions
[902] Module Supervision Enable/Reset
[903] View Module Supervision Field (Shows what is found after 902 is entered)

[904] Wireless Module Placement Test
Select the module / transmitter (Zones 01-64).
Press # to Cancel.
Placement Led Keypad Alpha Keypad Bell / Buzzer

Good Light 1 ON Steady GOOD 1 Beep / Squawk
Fair Light 2 ON Steady FAIR 2 Beeps / Squawks
Bad Light 3 ON Steady BAD 3 Beeps / Squawks
[980] Installer Buzzer Walk Test Mode Begin
[981] Installer Buzzer/Bell Walk Test Mode Begin
[982] Installer Walk Test Mode End (No Communications)
[983] Installer Walk Test Mode End (Communications)
[990] Installer Lockout Enable
[991] Installer Lockout Disable
[995] Restore WSS5580 Escort Factory Defaults Enter 995 + Installer Code + 995
[996] Restore WSS5132 Factory Defaults Enter 996 + Installer Code + 996
[997] Restore WSS5400 Factory Defaults Enter 997 + Installer Code + 997
[998] Restore WSS5908 Factory Defaults Enter 998 + Installer Code + 998
[999] Restore WS5010 Panel Factory Defaults Enter 999 + Installer Code + 999
PC5500 Alpha Keypad Programming Click HERE for PC5500 LCD Programming