[000] |
Keypad Assignment
Note: This must be done at each keypad requiring supervision
[0] Slot (Address) – |
Valid entries are 11-18 (for Slot 11 to 18) |
Note: Function Keys cannot be changed on LED or LCD Keypads |
|
[001] |
Zone 01-08 Definitions |
Default |
|
|
Default |
01 |
I_ _I_ _I |
Zone 01 |
05 |
I_ _I_ _I |
Zone 05 |
03 |
I_ _I_ _I |
Zone 02 |
05 |
I_ _I_ _I |
Zone 06 |
03 |
I_ _I_ _I |
Zone 03 |
05 |
I_ _I_ _I |
Zone 07 |
03 |
I_ _I_ _I |
Zone 04 |
05 |
I_ _I_ _I |
Zone 08 |
|
|
Zone Definitions
00 Null Zone (Not Used) |
09 Auto Verified 24 Hour Fire |
18 24 Hour Emergency |
01 Delay 1 |
10 24 Hour Supervisory (LINKS) |
19 24 Hour Sprinkler |
02 Delay 2 |
11 24 Hour Supervisory Buzzer |
20 24 Hour Water Detector |
03 Instant |
12 24 Hour Burglary |
21 24 Hour Freeze Warning |
04 Interior |
13 24 Hour Holdup |
22 24 Hour Latching Tamper |
05 Interior, Stay/Away |
14 24 Hour Gas |
23 Day Zone |
06 Delay, Stay/Away |
15 24 Hour High Temperature |
24 LINKS Answer |
07 Delay 24 Hr Fire |
16 24 Hour Medical |
87 Delay 24 Hr Fire (Wireless) |
08 Standard 24 Hr Fire |
17 24 Hour Panic |
88 Standard 24 Hr Fire (Wireless) |
|
[002] |
Zone 09-16 Definitions |
Default |
|
|
Default |
00 |
I_ _I_ _I |
Zone 09 |
00 |
I_ _I_ _I |
Zone 13 |
00 |
I_ _I_ _I |
Zone 10 |
00 |
I_ _I_ _I |
Zone 14 |
00 |
I_ _I_ _I |
Zone 11 |
00 |
I_ _I_ _I |
Zone 15 |
00 |
I_ _I_ _I |
Zone 12 |
00 |
I_ _I_ _I |
Zone 16
|
[003] |
Zone 17-24 Definitions |
Default |
|
|
Default |
00 |
I_ _I_ _I |
Zone 17 |
00 |
I_ _I_ _I |
Zone 21 |
00 |
I_ _I_ _I |
Zone 18 |
00 |
I_ _I_ _I |
Zone 22 |
00 |
I_ _I_ _I |
Zone 19 |
00 |
I_ _I_ _I |
Zone 23 |
00 |
I_ _I_ _I |
Zone 20 |
00 |
I_ _I_ _I |
Zone 24
|
[004] |
Zone 25-32 Definitions |
Default |
|
|
Default |
00 |
I_ _I_ _I |
Zone 25 |
00 |
I_ _I_ _I |
Zone 29 |
00 |
I_ _I_ _I |
Zone 26 |
00 |
I_ _I_ _I |
Zone 30 |
00 |
I_ _I_ _I |
Zone 27 |
00 |
I_ _I_ _I |
Zone 31 |
00 |
I_ _I_ _I |
Zone 28 |
00 |
I_ _I_ _I |
Zone 32
|
|
[005] |
System Times |
Default |
030 |
I_ _I_ _I_ _I |
Entry Delay 1 Enter 3 digits from |
[000-255] |
120 |
I_ _I_ _I_ _I |
Entry Delay 2 Enter 3 digits from |
[000-255] |
060 |
I_ _I_ _I_ _I |
Exit Delay Enter 3 digits from |
[000-255] |
006 |
I_ _I_ _I_ _I |
Bell Cut-off Enter 3 digits from |
[000-255] |
|
[006] |
Installer’s Code |
|
I_2_I_8_I_4_I_1_I_1_I_9_I Enter 6 Hexidecimal digits
|
[007] |
Master Code |
Default |
1234 |
I_ _I_ _I_ _I_ _I Enter 4 decimal digits
|
[009] |
WSS5010 PGM Output Programming (PGM 1 & 2) |
Default |
|
|
Default |
02 |
I_ _I_ _I |
PGM 1 |
03 |
I_ _I_ _I |
PGM 2 |
|
|
00 Not used |
15 Remote (DLS-1 Support) |
01 Burg & Fire Bell Output |
16 LINKS 1000 Support (PGM 1 only) |
02 Utility Output |
17 Fire Bell |
03 4-Wire Smoke Reset |
18 Burglary Bell |
04 2-Wire Smoke (PGM2 Only) |
19 Latched Strobe |
05 System Armed Status |
20 Latched Burglary |
06 Ready To Arm |
21 Latched Fire |
07 KP Buzzer Follow Mode |
22 Latched Panic |
08 Courtesy Pulse |
23 Latched Medical |
09 For future use |
24 Latched Supervisory |
10 For future use |
25 Latched Priority |
11 For future use |
26 Latched Holdup |
12 TLM and Alarm |
27 Auxiliary PGM Type 1 (ON/OFF) |
13 Kissoff Output |
28 Auxiliary PGM Type 1 (Pulse) |
14 Ground Start Pulse |
29 Auxiliary PGM Type 2 (ON/OFF) |
30 Auxiliary PGM Type 2 (Pulse) |
|
[010] |
WSS5208 PGM Output Programming (PGM 3-10) |
Default |
|
|
Default |
01 |
I_ _I_ _I |
PGM 3 |
01 |
I_ _I_ _I |
PGM 7 |
01 |
I_ _I_ _I |
PGM 4 |
01 |
I_ _I_ _I |
PGM 8 |
01 |
I_ _I_ _I |
PGM 5 |
01 |
I_ _I_ _I |
PGM 9 |
01 |
I_ _I_ _I |
PGM 6 |
01 |
I_ _I_ _I |
PGM 10
|
[011] |
WSS5204 PGM Output Programming (PGM 11-14) |
Default |
|
|
Default |
01 |
I_ _I_ _I |
PGM 11 |
01 |
I_ _I_ _I |
PGM 13 |
01 |
I_ _I_ _I |
PGM 12 |
01 |
I_ _I_ _I |
PGM 14
|
|
[012] |
Keypad Lockout Options |
Default |
005 |
I_ _I_ _I_ _I |
Number of Invalid Codes Before Lockout |
001 |
I_ _I_ _I_ _I |
Lockout Duration (in minutes) |
|
[013] |
First System Option Code |
Default |
|
Option ON |
OFF |
OFF |
I_ _I |
1 Normally Closed Loops |
End-of-Line Resistors |
OFF |
I_OFF_I |
2 Double End-of-Line Resistors |
Single End-of-Line Resistors |
ON |
I_ON_I |
3 On-board Zones 1-4 enabled* |
On-board Zones 1-4 disabled* |
ON |
I_ON_I |
4 On-board Zones 5-8 enabled* |
On-board Zones 5-8 disabled* |
OFF |
I_ON_I |
5 TLM Enabled |
TLM Disabled 5.10 |
ON |
I_ON_I |
6 TLM Audible When Armed |
TLM Trouble Only When Armed |
ON |
I_ON_I |
7 Event Buffer Follows Swinger |
Event Buffer Logs Events Past shutdown |
OFF |
I_OFF_I |
8 For Future Use
*On board zones (1 – 4 or 5 – 8) must be disabled if using Wireless (in blocks of 4)
|
[014] |
Second System Option Code |
Default |
|
Option ON |
OFF |
OFF |
I_OFF_I |
1 Arm/Disarm Bell Squawk enabled |
Arm / Disarm Bell Squawk disabled |
OFF |
I_OFF_I |
2 Bell Squawk on Trouble |
No Bell Squawk on Trouble |
ON |
I_ON_I |
3 Audible Exit Beeps with Urgency |
Silent Exit Delay |
OFF |
I_OFF_I |
4 Exit Delay Termination Enabled |
Exit Delay Termination disabled |
OFF |
I_ON_I |
5 Fire Bell doesn’t follow Cut-off |
Fire Bell follows Bell Cut-off |
ON |
I_ON_I |
6 Bell Output Burglary enabled |
Bell Output Burglary disabled |
ON |
I_ON_I |
7 Bell Out Fire enabled |
Bell Output Fire disabled |
ON |
I_ON_I |
8 Delayed Two-Wire Smoke PGM2 |
Instant Two-Wire Smoke on PGM2
|
[015] |
Third System Option Code |
Default |
|
Option ON |
OFF |
ON |
I_ON_I |
1 [F] Keys Enabled |
[F] Keys Disabled |
ON |
I_ON_I |
2 Quick Exit Enabled |
Quick Exit Disabled |
ON |
I_ON_I |
3 Arming Keys Don’t Req Code |
Arming Keys Require Access Code |
OFF |
I_OFF_I |
4 Master Code Not Changeable |
Master Code Changeable |
OFF |
I_OFF_I |
5 For Future Use |
OFF |
I_OFF_I |
6 Blank Keypad when Not Used |
Keypad Active |
ON |
I_ON_I |
7 Keypad Backlighting enabled |
Keypad Backlighting disabled |
ON |
I_OFF_I |
8 Bypass Status Display w/Armed |
Bypass Status Not Displayed |
|
|
Zone Attributes |
|
|
Opt 1 |
Opt 2 |
Opt 3 |
Opt 4 |
Opt 5 |
Opt 6 |
Opt 7 |
Opt 8 |
|
ON |
Audible |
Steady |
Chime |
Bypass |
Force |
Wireless |
Tx Delay |
Cross Zone |
|
OFF |
Silent |
Pulsed |
No |
No |
No |
No |
No |
No |
[101] |
Zone 1 |
I_ _I |
I_ _I |
I_ _I |
I_ _I |
I_ _I |
I_ _I |
I_ _I |
I_ _I |
|
all the way to |
[132] |
Zone 32 |
I_ _I |
I_ _I |
I_ _I |
I_ _I |
I_ _I |
I_ _I |
I_ _I |
I_ _I |
|
[160] |
Maximum Dialing Attempts to Each Phone Number |
Default |
008 |
I_ _I_ _I_ _I Valid entries are 001-255 attempts (Do not enter 000)
|
[161] |
Post Dial Wait for Handshake |
Default |
040 |
I_ _I_ _I_ _I Valid entries are 001-255 seconds
|
[162] |
Delay Between Dialing Attempts |
Default |
010 |
I_ _I_ _I_ _I Valid entries are 001-255 seconds
|
[170] |
Cross Zone Timer |
Default |
000 |
I_ _I_ _I_ _I Valid entries are 001-255 seconds
|
[171] |
Up and About Timer |
Default |
000 |
I_ _I_ _I_ _I Valid entries are 001-255 hours
|
[172] |
WSSFOB PGM Pulse Timer |
Default |
005 |
I_ _I_ _I_ _I Valid entries are 001-255 seconds
|
|
Communicator Programming |
[301] |
First Telephone Number (32 Digits)
I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I
*2 = * , *3 = #, *4 = Wait for Dial Tone, *5=2 Sec Pause, *6 End Number
(If adding more than one hex digit Example: *555* gives 3 2 second pauses)
|
[302] |
Pager Telephone Number (32 Digits) add at least 4 “E”‘s after pager for proper operation
I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I
If Pager program Number + pauses *5555* gives 4 2-second pauses
Pager will not send properly if Hex Characters A C D F are in Account Number
|
[310] |
Account Number (10 digits)
I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I
* 1 * = A * 2 * = B * 3 * = C * 4 * = D * 5 * = E * 6 * = F
|
[360] |
First Telephone Number Dialing Options |
Default |
|
Option ON |
OFF |
ON |
I_ON_I |
1 Alarms Enabled |
Disabled |
OFF |
I_OFF_I |
2 Alarm Restores Enabled |
Disabled |
OFF |
I_OFF_I |
3 Tamper Alarms Enabled |
Disabled |
OFF |
I_OFF_I |
4 Tamper Restores Enabled |
Disabled |
OFF |
I_OFF_I |
5 Openings Enabled |
Disabled |
OFF |
I_OFF_I |
6 Closings Enabled |
Disabled |
ON |
I_ON_I |
7 Maint. Alarms Enabled |
Disabled |
OFF |
I_OFF_I |
8 Maintenance Restore Enabled |
Disabled
|
[361] |
First Telephone Number LINKS Backup Dialing Options |
Default |
|
Option ON |
OFF |
OFF |
I_OFF_I |
1 Alarms Enabled |
Disabled |
OFF |
I_OFF_I |
2 Alarm Restores Enabled |
Disabled |
OFF |
I_OFF_I |
3 Tamper Alarms Enabled |
Disabled |
OFF |
I_OFF_I |
4 Tamper Restores Enabled |
Disabled |
OFF |
I_OFF_I |
5 Openings Enabled |
Disabled |
OFF |
I_OFF_I |
6 Closings Enabled |
Disabled |
OFF |
I_OFF_I |
7 Maintenance Alarm Enabled |
Disabled |
OFF |
I_OFF_I |
8 Maintenance Restore Enabled |
Disabled
|
[365] |
Second (Pager) Telephone Number Dialing Options |
Default |
|
Option ON |
OFF |
OFF |
I_OFF_I |
1 Closings Enabled |
Disabled |
OFF |
I_OFF_I |
2 Openings Enabled |
Disabled |
OFF |
I_OFF_I |
3 General System Event Enable |
Disabled |
OFF |
I_OFF_I |
4-8 For Future Use |
|
[370] |
Communication Variables |
Default |
005 |
I_0_I_0_I_5_I |
Swinger Shutdwn (Alarms&Rest) |
(001-014 Trans, 000=disabled) |
005 |
I_0_I_0_I_5_I |
Swinger Shutdwn (Tampers&Rest) |
(001-014 Trans, 000=disabled) |
005 |
I_0_I_0_I_5_I |
Swinger Shutdwn (Maint&Rest) |
(001-014 Trans, 000=disabled) |
000 |
I_0_I_0_I_0_I |
Communication Delay |
(001-255 seconds) |
030 |
I_0_I_6_I_0_I |
AC Failure Communication Delay |
(001-255 minutes) |
003 |
I_0_I_0_I_6_I |
TLM Trouble Delay Land Line |
(No. of valid checks required – 000-255 x 10s) |
030 |
I_0_I_3_I_0_I |
Test Transmission Cycle |
(001-255 days; 000 to disable) |
007 |
I_0_I_0_I_7_I |
Transmitter Low Battery Delay |
(000-255 days) |
|
[380] |
First Communicator Option Code |
Default |
|
Option ON |
OFF |
ON |
I_ON_I |
1 Communications Enabled |
Communications Disabled |
ON |
I_OFF_I |
2 Restorals on Bell Time-out |
Restorals Follow Zones |
OFF |
I_OFF_I |
3 Pulse Dialing |
DTMF Dialing |
ON |
I_ON_I |
4 Switch to Pulse 5th Attempt |
DTMF Dial For All Attempts |
OFF |
I_OFF_I |
5 Closing Confirmation Enable |
Disabled |
OFF |
I_OFF_I |
6 Partial Closings Identified |
Partial Closings are not Identified |
OFF |
I_OFF_I |
7-8 For Future Use
|
[390] |
LINKS Preamble (Telephone Number) |
Default |
FFFF |
I_ _I_ _I_ _I_ _I (Program all unused digits with Hex F)
|
[401] |
First Downloading Option Code |
Default |
|
Option ON |
OFF |
ON |
I_ON_I |
1 Double Call enabled |
Disabled |
ON |
I_ON_I |
2 User Call-up enabled |
Disabled |
ON |
I_OFF_I |
3 Call-Back Enabled |
Disabled |
OFF |
I_OFF_I |
4-8 For Future Use |
|
[402] |
Download Telephone Number (32 Digits)
I_L_I_E_I_A_I_V_I_E_I_ _I_B_I_L_I_A_I_N_I_K_I_ _I_ _I_ _I_ _I_ _I
|
[403] |
Downloading Access Code |
Default |
5010 or 9524 (Consult sheet for more codes) |
I__I__I__I__I Enter 4 Hexidecimal digits
|
[404] |
Number of Rings to Answer |
Default |
012 |
I_0_I_1_I_2_I (Valid entries are 001-255 rings; 000=answer disabled)
|
[405] |
Answering Machine Double-call Timer |
Default |
060 |
I_0_I_3_I_0_I (Valid entries are 001-255 seconds)
|
[490] |
Initiate PC-LINK (Direct Connect Local Download) |
|
Module Programming (Many of these modules are older versions) |
[801] |
PC5400 Printer Module Click HERE for PC5400 Programming |
[802] |
PC5908/5928 Intercom Module Click HERE for PC5908/5928 Programming
Click HERE for 2-Way Voice Programming
|
[804] |
PC5132 v3 Wireless Receiver Click HERE for PC5132 v2.1 Programming |
|
PC5132 v3.x and below use 900Mhz sensors PC5132 v4.x and above use 433Mhz sensors
All DSC Wireless sensor Serial Numbers go here EXCEPT
WLS910 Hand Held Keypad (see section 33 to 36)
WLS909 Keyfob (see section 41 to 56)
|
|
Zone Serial Numbers (Use “SN” Number from sticker on sensor, do not use “ESN” number)
Default = 000000
[01] Zone 01 |
I_ _I_ _I_ _I_ _I_ _I |
[17] Zone 17 |
I_ _I_ _I_ _I_ _I_ _I |
[02] Zone 02 |
I_ _I_ _I_ _I_ _I_ _I |
[18] Zone 18 |
I_ _I_ _I_ _I_ _I_ _I |
[03] Zone 03 |
I_ _I_ _I_ _I_ _I_ _I |
[19] Zone 19 |
I_ _I_ _I_ _I_ _I_ _I |
[04] Zone 04 |
I_ _I_ _I_ _I_ _I_ _I |
[20] Zone 20 |
I_ _I_ _I_ _I_ _I_ _I |
[05] Zone 05 |
I_ _I_ _I_ _I_ _I_ _I |
[21] Zone 21 |
I_ _I_ _I_ _I_ _I_ _I |
[06] Zone 06 |
I_ _I_ _I_ _I_ _I_ _I |
[22] Zone 22 |
I_ _I_ _I_ _I_ _I_ _I |
[07] Zone 07 |
I_ _I_ _I_ _I_ _I_ _I |
[23] Zone 23 |
I_ _I_ _I_ _I_ _I_ _I |
[08] Zone 08 |
I_ _I_ _I_ _I_ _I_ _I |
[24] Zone 24 |
I_ _I_ _I_ _I_ _I_ _I |
[09] Zone 09 |
I_ _I_ _I_ _I_ _I_ _I |
[25] Zone 25 |
I_ _I_ _I_ _I_ _I_ _I |
[10] Zone 10 |
I_ _I_ _I_ _I_ _I_ _I |
[26] Zone 26 |
I_ _I_ _I_ _I_ _I_ _I |
[11] Zone 11 |
I_ _I_ _I_ _I_ _I_ _I |
[27] Zone 27 |
I_ _I_ _I_ _I_ _I_ _I |
[12] Zone 12 |
I_ _I_ _I_ _I_ _I_ _I |
[28] Zone 28 |
I_ _I_ _I_ _I_ _I_ _I |
[13] Zone 13 |
I_ _I_ _I_ _I_ _I_ _I |
[29] Zone 29 |
I_ _I_ _I_ _I_ _I_ _I |
[14] Zone 14 |
I_ _I_ _I_ _I_ _I_ _I |
[30] Zone 30 |
I_ _I_ _I_ _I_ _I_ _I |
[15] Zone 15 |
I_ _I_ _I_ _I_ _I_ _I |
[31] Zone 31 |
I_ _I_ _I_ _I_ _I_ _I |
[16] Zone 16 |
I_ _I_ _I_ _I_ _I_ _I |
[32] Zone 32 |
I_ _I_ _I_ _I_ _I_ _I
|
Handheld Keypad Serial Numbers
Default = 000000
|
[33] Keypad 01 |
I_ _I_ _I_ _I_ _I_ _I |
[35] Keypad 03 |
I_ _I_ _I_ _I_ _I_ _I |
[34] Keypad 02 |
I_ _I_ _I_ _I_ _I_ _I |
[36] Keypad 04 |
I_ _I_ _I_ _I_ _I_ _I
|
Wireless Keyfob Serial Numbers
Default = 000000
|
[41] Key 01 |
I_ _I_ _I_ _I_ _I_ _I |
[49] Key 09 |
I_ _I_ _I_ _I_ _I_ _I |
[42] Key 02 |
I_ _I_ _I_ _I_ _I_ _I |
[50] Key 10 |
I_ _I_ _I_ _I_ _I_ _I |
[43] Key 03 |
I_ _I_ _I_ _I_ _I_ _I |
[51] Key 11 |
I_ _I_ _I_ _I_ _I_ _I |
[44] Key 04 |
I_ _I_ _I_ _I_ _I_ _I |
[52] Key 12 |
I_ _I_ _I_ _I_ _I_ _I |
[45] Key 05 |
I_ _I_ _I_ _I_ _I_ _I |
[53] Key 13 |
I_ _I_ _I_ _I_ _I_ _I |
[46] Key 06 |
I_ _I_ _I_ _I_ _I_ _I |
[54] Key 14 |
I_ _I_ _I_ _I_ _I_ _I |
[47] Key 07 |
I_ _I_ _I_ _I_ _I_ _I |
[55] Key 15 |
I_ _I_ _I_ _I_ _I_ _I |
[48] Key 08 |
I_ _I_ _I_ _I_ _I_ _I |
[56] Key 16 |
I_ _I_ _I_ _I_ _I_ _I
|
Handheld Keypad Options |
[57] Function Key 1 |
I_ _I_ _I |
[59] Function Key 3 |
I_ _I_ _I |
[58] Function Key 2 |
I_ _I_ _I |
[60] Function Key 4 |
I_ _I_ _I
|
Wireless Key Options |
[65] Function Key 1 |
I_ _I_ _I |
[67] Function Key 3 |
I_ _I_ _I |
[66] Function Key 2 |
I_ _I_ _I |
[68] Function Key 4 |
I_ _I_ _I |
|
[00] Key Not Used |
[16] * 0 Quick Exit |
[01] For Future Use |
[17] * 1 Reactivate Stay/Aways |
[02] For Future Use |
[18] For Future Use |
[03] Stay Arm |
[19] * 7 3 Command Output 3 |
[04] Away Arm |
[20] For Future Use |
[05] * 9 No-Entry Arm |
[21] * 7 4 Command Output 4 |
[06] * 4 Chime ON/OFFl |
[22] For Future Use |
[07] * 6 — 4 System Test |
[23] For Future Use |
[08] For Future Use |
[24] For Future Use |
[09] For Future Use |
[25] For Future Use |
[10] For Future Use |
[26] For Future Use |
[11] For Future Use |
[27] Disarm (OFF) |
[12] For Future Use |
[28] Fire Alarm |
[13] * 7 1 Command Output 1 |
[29] Aux/Medical Alarm |
[14] * 7 2 Sensor Reset |
[30] Police Panic |
[15] For Future Use |
|
|
|
Special Installer Functions |
[902] |
Module Supervision Enable/Reset |
[903] |
View Module Supervision Field (Shows what is found after 902 is entered)
|
[904] |
Wireless Module Placement Test
Select the module / transmitter (Zones 01-64).
Press # to Cancel.
Placement Led Keypad Alpha Keypad Bell / Buzzer
- Good Light 1 ON Steady GOOD 1 Beep / Squawk
- Fair Light 2 ON Steady FAIR 2 Beeps / Squawks
- Bad Light 3 ON Steady BAD 3 Beeps / Squawks
|
[980] |
Installer Buzzer Walk Test Mode Begin |
[981] |
Installer Buzzer/Bell Walk Test Mode Begin |
[982] |
Installer Walk Test Mode End (No Communications) |
[983] |
Installer Walk Test Mode End (Communications) |
[990] |
Installer Lockout Enable |
[991] |
Installer Lockout Disable |
[995] |
Restore WSS5580 Escort Factory Defaults Enter 995 + Installer Code + 995 |
[996] |
Restore WSS5132 Factory Defaults Enter 996 + Installer Code + 996 |
[997] |
Restore WSS5400 Factory Defaults Enter 997 + Installer Code + 997 |
[998] |
Restore WSS5908 Factory Defaults Enter 998 + Installer Code + 998 |
[999] |
Restore WS5010 Panel Factory Defaults Enter 999 + Installer Code + 999 |
|