DSC PC1555 Basic
Zones |
|
||||||||||||
Batteries |
|
||||||||||||
Downloadable | Yes, press * + 6 + Master Code + 5 + # to enable | ||||||||||||
Panic Buttons | Yes, for Police, Fire and Medical | ||||||||||||
Arm Enter |
4-digit code or hold AWAY or STAY for 3 seconds |
||||||||||||
Quick-Arm | * 0 to Arm system | ||||||||||||
Instant Arm | * 9 before or after arming system | ||||||||||||
Stay Arm |
Arm system and don’t leave, motions auto-bypass (some keypads press STAY button for 3 seconds) |
||||||||||||
Disarm | 4-digit Code (Press # if any mistake is made) | ||||||||||||
Silence Alarm | 4-digit Code (Press # to stop keypad flashing) | ||||||||||||
Quick Exit | * 0 allows 2-minutes to leave while armed (If enabled) | ||||||||||||
Bypass |
|
||||||||||||
Reset Smoke | * 7 2 (If smoke continues to sound power down, smoke is bad) | ||||||||||||
Door Chime |
Hold CHIME key for 3 seconds or * 4 to enable/disable |
||||||||||||
Alarm Memory | * 3 to view last alarm | ||||||||||||
Event Buffer |
1. Press * 6 + Master Code 2. Press < or > keys to scroll to “Event Buffer” then press * 3. Use < key to move forward in time, use > key to move backward in time 4. Press * to toggle between Time/Date of Event and what the Event was Examples: Closing by User 40 = Master Code Armed System Opening by User 01 = User 01 Disarmed system Zone Fault Zone 24 = Zone 24 is in trouble |
||||||||||||
Sensor Test |
None, Arm system then trip sensors (Wireless motions require no movement for 4 minutes prior to testing) |
||||||||||||
Siren Test | * 6 + Master Code + 4 | ||||||||||||
System Clock |
* 6 + Master Code + 1 + Time (Example 1:30PM July 2nd 2000 would be 1300070200) |
||||||||||||
Keypad Tones | Hold * until desired volume is found | ||||||||||||
Auto Arm | * + 6 + Master Code + 2 (3 beeps=Enable, 1 long beep=Disable) | ||||||||||||
Auto Arm Time | * + 6 + Master Code + 3 + HHMM (Military Time) | ||||||||||||
Enable Dnld | * + 6 + Master Code + 5 + # (Enables for 6 hours) |