DSC PC1555 Basic

Zones
PC1555 v2.0 = 6 Hardwired, up to 8 total zones hardwired or wireless
PC1555 v2.1 = 6 Hardwired, up to 8 total zones hardwired or wireless
PC1555 v2.3 = 32 total zones wireless or hardwired, 6 on-board hardwired
(Keypads can have 1 zone each)
Batteries
Main Panel 12 volt rechargeable Gel-Cell
Door/Windows 3 to 4 AAA Alkaline
Motion Sensor 4 AAA Alkaline
Smoke Detector 6 AA Alkaline
4-button Keyfob Button type batteries #LR44
Pendant Panic Non-Replaceable
Downloadable Yes, press * + 6 + Master Code + 5 + # to enable
Panic Buttons Yes, for Police, Fire and Medical
Arm Enter 4-digit code
or hold AWAY or STAY for 3 seconds
Quick-Arm * 0 to Arm system
Instant Arm * 9 before or after arming system
Stay Arm Arm system and don’t leave, motions auto-bypass
(some keypads press STAY button for 3 seconds)
Disarm 4-digit Code (Press # if any mistake is made)
Silence Alarm 4-digit Code (Press # to stop keypad flashing)
Quick Exit * 0 allows 2-minutes to leave while armed (If enabled)
Bypass
Press * 1 (BYPASS or SYSTEM light will flash)
Enter Zone to bypass (01 to 08) (Zone light will turn ON)
Press # to exit (BYPASS or SYSTEM light stays ON)
(If this doesn’t work try * 1 + Master Code + (01 to 08) + #)
Reset Smoke * 7 2 (If smoke continues to sound power down, smoke is bad)
Door Chime Hold CHIME key for 3 seconds
or * 4 to enable/disable
Alarm Memory * 3 to view last alarm
Event Buffer 1. Press * 6 + Master Code
2. Press < or > keys to scroll to “Event Buffer” then press *
3. Use < key to move forward in time, use > key to move backward in time
4. Press * to toggle between Time/Date of Event and what the Event was
Examples: Closing by User 40 = Master Code Armed System
Opening by User 01 = User 01 Disarmed system
Zone Fault Zone 24 = Zone 24 is in trouble
Sensor Test None, Arm system then trip sensors
(Wireless motions require no movement for 4 minutes prior to testing)
Siren Test * 6 + Master Code + 4
System Clock * 6 + Master Code + 1 + Time
(Example 1:30PM July 2nd 2000 would be 1300070200)
Keypad Tones Hold * until desired volume is found
Auto Arm * + 6 + Master Code + 2 (3 beeps=Enable, 1 long beep=Disable)
Auto Arm Time * + 6 + Master Code + 3 + HHMM (Military Time)
Enable Dnld * + 6 + Master Code + 5 + # (Enables for 6 hours)