Caddx NX-8 Program v2

Download Callback * 98 # = calls download computer (User Code after may be required)
Download Answer * 99 # = picks up phone ringing (User Code after may be required)

Enter Program 1. Press * + 8 (STAY/CHIME/EXIT/BYPASS/CANCEL lights will flash)
2. 9713 (default) (STAY/CHIME/EXIT/BYPASS/CANCEL lights flash, SERVICE turns ON)
3. 0 + # (STAY CHIME EXIT BYPASS CANCEL, SERVICE, ARMED turns ON)
(If incorrect Install code entered STAY/CHIME/EXIT/BYPASS/CANCEL will continue flashing)

Move to Location Location + #

Enter Data Enter data + * which saves and moves to next digit within location, # exits at any time
Example: To change Receiver Phone 1
1. Press 0 + # (Moves to location 0)
2. Enter 15 + * (Selects Touch Tone dialing)
3. Enter 1 * 8 * 0 etc (End Phone Number with 14 + *)
4. Press # to exit (Moves back to start of programming)

Exit Program Press EXIT key twice
Factory Default 910 # while in programming (Last resort)
Enroll Modules 915 + # while in programming (Keypads & Zone Expanders must be enrolled)
Hex Program 10 = A 11 = B 12 = C 13 = D 14 = E 15 = F
[Click HERE for Keypad Programming]

0# Receiver Number 1 (20 Digits)
11 (B) = *
12 (C) = #
13 (D) = 4 Second Pause
14 (E) = End of Number
15 (F) = Touch Tone
I_F_I_1_I_8_I_?_I_?_I_?_I_?_I_?_I_?_I_?_I_?_I_E_I
(Program as 15 * 1 * 8 * 0 * 0 * then 14 * # to end)
(Don’t use 10’s for 0’s)
1# Account Number (6 digits) I_?_I_?_I_?_I_?_I_10_I_ _I (Enter 4 digits, 10 ends, # exits)
(Example: if account is 1234 program as 1* 2* 3* 4* 10*#)

2# Report Format I_14_I (Enter digit then * to save and exit)
0 = Communicator Disabled
1 = Universal 4/2
2 = 3/1 or 4/1 Fast
3 = Reserved
4 = Pager
5 = 3/1 or 4/1 slow (1800hz transmit, 2300hz handshake 20pps)
6 = 3/1 or 4/1 slow (1800hz transmit, 1400hz handshake 20pps)
7 = 3/1 or 4/1 fast (1800hz transmit, 2300hz handshake 40pps)
8 = 3/1 or 4/1 fast (1800hz transmit, 1400hz handshake 40pps)
9 = 3/1 or 4/1 fast w/parity (1800hz transmit, 2300hz handshake 40pps)
10 = 3/1 or 4/1 fast w/parity (1800hz transmit, 1400hz handshake 40pps)
11 = 4/2 Express
12 = 4/2 Fast (1900hz transmit, 1400hz handshake 20pps)
13 = Contact ID
14 = SIA
15 = Custom (See location 18)
3# Dial Attempts/Backup Control I_8_I_1_I (Enter digit then * to save)
(Enter 1 in second digit to only dial first numberthen * to save and exit)

4# Events to Report Phone 1 Segment 1 (Toggle On/Off then * for segment 2, # exits)
Default Option ON OFF
ON I_ON_I 1 Alarms and Restores Disabled
ON I_OFF_I 2 Opening/Closings Disabled
ON I_OFF_I 3 Bypass and Restores Disabled
ON I_ON_I 4 Zone Trouble and Restores Disabled
ON I_ON_I 5 AC Failure, Low Batt and Restores Disabled
ON I_ON_I 6 Siren Trouble and Restores Disabled
ON I_ON_I 7 Test Reports Disabled
ON I_OFF_I 8 Start/End prog and DL Finished Disabled

Events to Report Phone 1 Segment 2 (Toggle On/Off then press * to save and exit)
Default Option ON OFF
ON I_ON_I 1 Tampers and Restores Disabled
ON I_ON_I 2 Aux Power Over Current and Restore Disabled
ON I_ON_I 3 Sensor Missing and Restore Disabled
ON I_ON_I 4 Sensor Low Battery and Restore Disabled
ON I_ON_I 5 Expander Trouble and Restore Disabled
ON I_ON_I 6 Failure To Communicate Disabled
ON I_ON_I 7 Zone Activity Monitor Disabled
ON I_ON_I 8 Reserved

5# Select Partition to Report to Phone 1 (Toggle On/Off then press * to save and exit)
Default Option ON OFF
ON I_ON_I 1 Partition 1 Disabled
ON I_ON_I 2 Partition 2 Disabled
6# Receiver Number 2 (20 Digits) I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I
7# Account Number 2 (6 digits) I_ _I_ _I_ _I_ _I_ _I_ _I (Not Used)
8# Report Format Phone 2 I_ _I (Not Used)
9# Dial Attempts Phone 2 I_ _I_ _I (Not Used)

10# Events to Report Phone 2 Segment 1 (Toggle On/Off then * for segment 2, # exits)
Default Option ON OFF
ON I_ON_I 1 Alarms and Restores Disabled
ON I_OFF_I 2 Opening/Closings Disabled
ON I_OFF_I 3 Bypass and Restores Disabled
ON I_ON_I 4 Zone Trouble and Restores Disabled
ON I_ON_I 5 AC Failure, Low Batt and Restores Disabled
ON I_ON_I 6 Siren Trouble and Restores Disabled
ON I_ON_I 7 Test Reports Disabled
ON I_OFF_I 8 Start/End prog and DL Finished Disabled

Events to Report Phone 2 Segment 2 (Toggle On/Off then press * to save and exit)
Default Option ON OFF
ON I_ON_I 1 Tampers and Restores Disabled
ON I_ON_I 2 Aux Power Over Current and Restore Disabled
ON I_ON_I 3 Sensor Missing and Restore Disabled
ON I_ON_I 4 Sensor Low Battery and Restore Disabled
ON I_ON_I 5 Expander Trouble and Restore Disabled
ON I_ON_I 6 Failure To Communicate Disabled
ON I_ON_I 7 Zone Activity Monitor Disabled
ON I_ON_I 8 Reserved

11# Select Partition to Report to Phone 2 (Toggle On/Off then press * to save and exit)
Default Option ON OFF
OFF I_ON_I 1 Partition 1 Disabled
OFF I_ON_I 2 Partition 2 Disabled
12# Receiver Number 3 (20 Digits) I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I
13# Account Number 3 (6 digits) I_ _I_ _I_ _I_ _I_ _I_ _I
(Enter 4 digits then 10 to end * saves, # exits)
14# Report Format Phone 3 I_ _I (Enter digit then * to save and exit)
15# Dial Attempts Phone 3 I_ _I_ _I (Enter digit then * to save and exit)

16# Events to Report Phone 3 Segment 1 (Toggle On/Off then * for segment 2, # exits)
Default Option ON OFF
ON I_ON_I 1 Alarms and Restores Disabled
ON I_OFF_I 2 Opening/Closings Disabled
ON I_OFF_I 3 Bypass and Restores Disabled
ON I_ON_I 4 Zone Trouble and Restores Disabled
ON I_ON_I 5 AC Failure, Low Batt, Restores Disabled
ON I_ON_I 6 Siren Trouble and Restores Disabled
ON I_ON_I 7 Test Reports Disabled
ON I_OFF_I 8 Start/End prog and DL Finished Disabled

Events to Report Phone 3 Segment 2 (Toggle On/Off then press * to save and exit)
Default Option ON OFF
ON I_ON_I 1 Tampers and Restores Disabled
ON I_ON_I 2 Aux Pwr Over Current/Restore Disabled
ON I_ON_I 3 Sensor Missing and Restore Disabled
ON I_ON_I 4 Sensor Low Batt/Restore Disabled
ON I_ON_I 5 Expander Trouble and Restore Disabled
ON I_ON_I 6 Failure To Communicate Disabled
ON I_ON_I 7 Zone Activity Monitor Disabled
ON I_ON_I 8 Reserved

17# Phone 3 Select Part to Report to Phn 3 (Toggle On/Off then press * to save and exit)
Default Option ON OFF
OFF I_OFF_I 1 Partition 1 Disabled
OFF I_OFF_I 2 Partition 2 Disabled

18# Format Override Segment 1 (Toggle On/Off then * for segment 2, # exits)
Default Option ON OFF
OFF I_OFF_I 1 1800Hz Transmit 1900Hz Transmit
OFF I_OFF_I 2 2300Hz Handshake 1400Hz Handshake
OFF I_OFF_I 3 Checksum Parity Double Round Parity
OFF I_OFF_I 4 2-Digit Event Code 1-Digit Event Code
OFF I_OFF_I 5 Reserved
OFF I_OFF_I 6 Reserved
OFF I_OFF_I 7 20 PPS 10 or 40 PPS
OFF I_OFF_I 8 10 PPS 20 or 40 PPS

Format Override Segments 2 (Toggle On/Off then * for segment 3, # exits)
Default Option ON OFF
OFF I_OFF_I 1 Pager Format Disabled
OFF I_OFF_I 2 1400/2300 Handshake Disabled
OFF I_OFF_I 3 Reserved Disabled
OFF I_OFF_I 4 Reserved Disabled
OFF I_OFF_I 5 Contact ID Disabled
OFF I_OFF_I 6 SIA Disabled
OFF I_OFF_I 7 Contact ID or 4 + 3 Disabled
OFF I_OFF_I 8 DTMF Disabled

Format Override Segments 3 (Toggle On/Off then * for segment 4, # exits)
Reserved

Format Override Segments 4 (Toggle On/Off then * to save and exit)
Reserved
19# Download Access Code I_8_I_4_I_8_I_0_I_0_I_0_I_0_I_0_I
(Program as 8* 4* 8* 0* 0* 0* 0* 0* then # to exit)
20# Rings to Answer Download I_8_I (Then press * to save and exit)
1-15, 0 to disable

21# Download Control (Toggle On/Off then press * to save and exit)
Default Option ON OFF
OFF I_ON_I 1 Two Call Answering Machine Defeat Disabled
OFF I_OFF_I 2 Tone Sniff Answering Machine Defeat Disabled
OFF I_OFF_I 3 Callback Enabled Disabled
OFF I_OFF_I 4 Shut Down Control Panel Disabled
OFF I_OFF_I 5 Lock Out Local Programming Disabled
OFF I_OFF_I 6 Lock Out Communicator Programming Disabled
OFF I_OFF_I 7 Lockout Download Section Disabled
OFF I_OFF_I 8 Enable Callback at AutoTest Disabled
22# Callback Phone Number I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I

23# Partition 1 Feature Selection Segment 1 (Toggle On/Off then * for segment 2, # exits)
Default Option ON OFF
OFF I_ON_I 1 Quick Arm Enable Disabled
OFF I_ON_I 2 Quick Exit Enable Disabled
ON I_OFF_I 3 Auto Bypass Enable Disabled
OFF I_OFF_I 4 Silent Keypad Panic Disabled
ON I_ON_I 5 Audible Keypad Panic Disabled
OFF I_ON_I 6 Keypad Aux 1 (Fire Panic) Disabled
OFF I_ON_I 7 Keypad Aux 2 (Med Panic) Disabled
OFF I_ON_I 8 Multi Code Attempt Shutdown Disabled

Segment 2 (Toggle On/Off then * for segment 3, # exits)
Default Option ON OFF
OFF I_OFF_I 1 LED Estinguish Disabled
OFF I_OFF_I 2 User Code Required to Bypass Disabled
OFF I_OFF_I 3 Zone Bypass Sounder Alert Disabled
ON I_ON_I 4 AC Fail/Low Bat Sounder Alert Disabled
OFF I_OFF_I 5 Bypass Toggle Disabled
OFF I_OFF_I 6 Silent Auto Arm Disabled
OFF I_OFF_I 7 Auto Instant Disabled
OFF I_OFF_I 8 Instant Mode Toggle Disabled

Segment 3 (Toggle On/Off then press * to save and exit)
Default Option ON OFF
OFF I_OFF_I 1 Opening/Closing Reporting Enable Disabled
OFF I_OFF_I 2 Zone Bypass Reporting Enable Disabled
OFF I_OFF_I 3 Zone Restore Report Enable Disabled
OFF I_OFF_I 4 Zone Trouble Report Enable Disabled
OFF I_OFF_I 5 Zone Tamper Report Enable Disabled
ON I_ON_I 6 Cancel Report Enable Disabled
ON I_OFF_I 7 Recent Closing Report Enable Disabled (Off if CID format on if SIA)
ON I_ON_I 8 Exit Error Report Enable Disabled

Segment 4 (Toggle On/Off then * for segment 5, # exits)
Default Option ON OFF
OFF I_OFF_I 1 Late Close/Early Open Enable Disabled
OFF I_OFF_I 2 Auto Arm Stay Mode Auto Arm Away Mode
OFF I_OFF_I 3 Night Mode Instant Night Mode Stay
OFF I_OFF_I 4 Disable Bypass for Force Arm Zones Enable Bypass for Force Arm Zones
OFF I_OFF_I 5 Reserved
OFF I_OFF_I 6 Reserved
OFF I_OFF_I 7 Reserved
OFF I_OFF_I 8 Reserved

Segment 5 (Toggle On/Off then press * to save and exit)
Reserved
24# Partition 1 Entry/Exit Times (Enter each pair of digits * for next, # Exits)
Default
030 I_ _I_ _I_ _I Entry Time 1 (30 to 255 Seconds)
060 I_ _I_ _I_ _I Exit Time 1 (45 to 255 Seconds)
030 I_ _I_ _I_ _I Entry Time 2 (30 to 255 Seconds)
060 I_ _I_ _I_ _I Exit Time 2 (45 to 255 Seconds)
000 I_ _I_ _I_ _I Reserved (* to bypass)
000 I_ _I_ _I_ _I Reserved (* to bypass and exit)

25# Zones 1 to 8 Type (Enter each digit then * for next, # Exits)
Default
3 I_ _I 1 Zone 1
[Click HERE for Zone Types]
[Click HERE for Zone Attributes]
[Click HERE for Wireless Zones]
5 I_ _I 2 Zone 2
6 I_ _I 3 Zone 3
6 I_ _I 4 Zone 4
6 I_ _I 5 Zone 5
6 I_ _I 6 Zone 6
6 I_ _I 7 Zone 7
6 I_ _I 8 Zone 8

26# Partition Selections Zones 1 to 8 (Enter each digit then * for next, # Exits)
Default
1 I_ _I Zone 1 1 = Partition 1
1 I_ _I Zone 2 2 = Partition 2
1 I_ _I Zone 3 (A zone can occupy more than 1 partition)
1 I_ _I Zone 4 (Ex: press 1 2 for Zone 1 to use partition 1, 2,
1 I_ _I Zone 5 then press * to move to zone 2 etc)
1 I_ _I Zone 6
1 I_ _I Zone 7
1 I_ _I Zone 8

27# Zones 9 to 16 Zone Type (Enter each digit then * for next, # Exits)
Default
6 I_ _I Zone 9
[Click HERE for Zone Types]
[Click HERE for Zone Attributes]
[Click HERE for Wireless Zones]
6 I_ _I Zone 10
6 I_ _I Zone 11
6 I_ _I Zone 12
6 I_ _I Zone 13
6 I_ _I Zone 14
6 I_ _I Zone 15
6 I_ _I Zone 16

28# Partition Selections Zones 9 to 16 (Enter each digit then * for next, # Exits)
Default
1 I_ _I Zone 9 1 = Partition 1
1 I_ _I Zone 10 2 = Partition 2
1 I_ _I Zone 11 (Ex: press 1 2 for Zone 9 to use partition 1, 2,
1 I_ _I Zone 12 then press * to move to Zone 10 etc)
1 I_ _I Zone 13
1 I_ _I Zone 14
1 I_ _I Zone 15
1 I_ _I Zone 16

37# Siren & System Supervision Segment 1 (Toggle On/Off then * for Segment 2, # exits)
Default Option ON OFF
ON I_ON_I 1 Siren Sounds for Line Cut Armed Disabled
ON I_OFF_I 2 Siren Sounds for Line Cut Disarmed Disabled
OFF I_OFF_I 3 Siren Blast at Arming Disabled
OFF I_OFF_I 4 Siren Blast at Exit Delay Expiration Disabled
OFF I_OFF_I 5 Siren Blast at Closing Kissoff Disabled
OFF I_OFF_I 6 Siren Sounds on Cross Zone Verification Disabled
ON I_ON_I 7 Siren Sounds for a Tamper Disabled
OFF I_OFF_I 8 Siren Sounds Keyswitch/Fob Arm/Disarm Disabled

Siren & System Supervision Segment 2 (Toggle On/Off then * for Segment 3, # exits)
Default Option ON OFF
OFF I_OFF_I 1 Convert Siren Driver to Voltage Out Disabled
OFF I_OFF_I 2 Siren Sounds for Expander Trouble Disabled
OFF I_OFF_I 3 Immediate Restore by Zone Disabled
OFF I_OFF_I 4 Dynamic Battery Test upon Arming Disabled
OFF I_OFF_I 5 Battery Missing Test every 12 Seconds Disabled
ON I_ON_I 6 Manual Bell Test by * 4 Test Function Disabled
OFF I_ON_I 7 Manual Com Test by * 4 Test Function Disabled
OFF I_OFF_I 8 Box Tamper Enabled Disabled

Siren & System Supervision Segment 3 (Toggle On/Off then * for Segment 4, # exits)
Default Option ON OFF
OFF I_OFF_I 1 Box Tamper Report Enabled Disabled
OFF I_ON_I 2 AC Fail Report Enabled Disabled
OFF I_ON_I 3 Low Battery Report Enabled Disabled
OFF I_ON_I 4 Aux Power Over Current Report Disabled
OFF I_ON_I 5 Siren Supervision Report Enabled Disabled
OFF I_OFF_I 6 Phone Line Cut Report Enabled Disabled
OFF I_OFF_I 7 Ground Fault Detection Report Disabled
OFF I_ON_I 8 Expander Trouble Report Enabled Disabled

Siren & System Supervision Segment 4 (Toggle On/Off then * for Segment 5, # exits)
Default Option ON OFF
OFF I_ON_I 1 Fail To Communicate Report Enabled Disabled
OFF I_OFF_I 2 Log Full Report Enabled Disabled
OFF I_ON_I 3 Autotest Report Enabled Disabled
OFF I_OFF_I 4 Start & End Programming Report Disabled
OFF I_OFF_I 5 End Download Report Enabled Disabled
OFF I_ON_I 6 Sensor Low Battery Report Enabled Disabled
OFF I_ON_I 7 Sensor Missing Report Enabled Disabled
OFF I_OFF_I 8 First to Open/Last to Close Disabled

Siren & System Supervision Segment 5 (Toggle On/Off then * for Segment 6, # exits)
Default Option ON OFF
OFF I_OFF_I 1 Lost Clock Service LED Enable Disabled
OFF I_OFF_I 2 Zone Doubling Enabled Disabled
OFF I_OFF_I 3 Disable On-Board Zones Disabled
OFF I_OFF_I 4 Enable 2 Trip on Cross Zone for Alarm Disabled
OFF I_OFF_I 5 Disable Bypass Report on Force Arm Disabled
OFF I_OFF_I 6 Reserved
OFF I_OFF_I 7 Clock Uses Internal Crystal Disabled
OFF I_OFF_I 8 Disable Temporal Siren on Fire Alarm Disabled

Siren & System Supervision Segment 6 (Toggle On/Off then * for Segment 7, # exits)
Default Option ON OFF
OFF I_OFF_I 1 Enable 2-wire Smoke Disabled
OFF I_OFF_I 2 Reserved
OFF I_OFF_I 3 Zone Activity in Hours Zone Activity in Days
OFF I_OFF_I 4 Enable Daylight Savinfs Time (DST) Disabled
OFF I_OFF_I 5 Reserved
OFF I_OFF_I 6 Disable Clean Me Report Enabled
OFF I_OFF_I 7 Disable Start/End Test Report Enabled
OFF I_OFF_I 8 Auto LED Extinguish Enable Disabled

Siren & System Supervision Segment 7 (Toggle On/Off then press * to save and exit)
Reserved
38# Swinger Shutdown Count I_3_I

39# Keypad Sounder Control (Toggle On/Off then press * to save and exit)
Default Option ON OFF
ON I_OFF_I 1 Keypad Sounds for Line Cut Armed Disabled
ON I_OFF_I 2 Keypad Sounds for Line Cut Disarmed Disabled
OFF I_OFF_I 3 Keypad Sounds on AC Failure Disabled
OFF I_OFF_I 4 Keypad Sounds on Low Battery Disabled
OFF I_OFF_I 5 Keypad Sounds on Cross Zone Trip Disabled
OFF I_ON_I 6 Keypad Sounds For Tamper Alarms Disabled
OFF I_OFF_I 7 Reserved
OFF I_OFF_I 8 Keypad Sounds For Expander Trouble Disabled

40# System Timers (Enter each digit then * for next, # Exits)
Default
0 I_ _I Dynamic Battery Test Duration (0 to 255 minutes)
5 I_ _I AC Fail Report Delay (0 to 255 minutes)
60 I_ _I Power Up Delay (0 to 60 seconds)
8 I_ _I Siren Timeout (1 to 255 minutes)
0 I_ _I Telephone Line Cut Delay (0 to 255 seconds)
5 I_ _I Cross Zone Time (0 to 255 minutes)
3 I_ _I Chime Time (0 to 255 x50ms)
30 I_ _I Dialer Delay (15 to 255 seconds)
0 I_ _I Fire Alarm Verif Time (120 to 255 seconds)
0 I_ _I Listen In Time (0 to 255 seconds)
0 I_ _I Zone Monitor Timer (0 to 255 days)
0 I_ _I Reserved (* to bypass)
0 I_ _I Reserved (* to bypass)
0 I_ _I Reserved (* to bypass and exit)

41# User Code Requirements (Toggle On/Off then press * to save and exit)
Default Option ON OFF
OFF I_OFF_I 1 Enable 6-Digit User Codes Disabled
OFF I_OFF_I 2 User Code Reqrd for *98 & *99 Disabled
OFF I_OFF_I 3 Auto Cancel/Abort Enabled Disabled
OFF I_OFF_I 4 Walk Test Mode Enabled Disabled
OFF I_OFF_I 5 Auto Force-Arming Keyfob or Keyswitch Disabled
OFF I_OFF_I 6 Reserved
OFF I_OFF_I 7 Reserved
OFF I_OFF_I 8 Reserved

42# Go To Program Code I_4_I_8_I_5_I_0_I_10_I_ _I
(Program as 4 * 8 * 5 * 0 * 10 * then # to exit)

43# Go To Program Options Segment 1 (Toggle On/Off then * for Segment 2, # exits)
Default Option ON OFF
OFF I_OFF_I 1 Reserved
OFF I_OFF_I 2 Program Code is Arm Only Code Disabled
OFF I_OFF_I 3 Program Code is Arm Only after Close Disabled
OFF I_OFF_I 4 Program Code is Master Code* Disabled
OFF I_OFF_I 5 Program Code is Arm/Disarm Code Disabled
OFF I_OFF_I 6 Program Code Bypasses Zones Disabled
OFF I_OFF_I 7 Program Code Sends O/C Reports Disabled
OFF I_OFF_I 8 Reserved
* enable in case Master Code is forgotten, use Installer Code to add new Master Code

Go To Program Options Segment 2 (Toggle On/Off then press * to save and exit)
Default Option ON OFF
OFF I_OFF_I 1 Program Code Active Partition 1 Disabled
OFF I_OFF_I 2 Program Code Active Partition 2 Disabled
44# Duress Code I_2_I_5_I_8_I_0_I_10_I_ _I
(Program as 2 * 5 * 8 * 0 * 10 * then # to exit)

45# Auxiliary Outputs 1 to 4 Partition Selection
Auxiliary Output 1 Segment 1 (Toggle On/Off then * for SSegment 2, # exits)
Default Option ON Option OFF
ON I_ON_I 1 Partition 1 Not on Partition 1
ON I_ON_I 2 Partition 2 Not on Partition 2

Auxiliary Output 2 Segment 2 (Toggle On/Off then * for Segment 3, # exits)
Default Option ON Option OFF
ON I_ON_I 1 Partition 1 Not on Partition 1
ON I_ON_I 2 Partition 2 Not on Partition 2

Auxiliary Output 3 Segment 3 (Toggle On/Off then * for Segment 4, # exits)
Default Option ON Option OFF
ON I_ON_I 1 Partition 1 Not on Partition 1
ON I_ON_I 2 Partition 2 Not on Partition 2

Auxiliary Output 4 Segment 4 (Toggle On/Off then * to save, # exits)
Default Option ON Option OFF
ON I_ON_I 1 Partition 1 Not on Partition 1
ON I_ON_I 2 Partition 2 Not on Partition 2

46# Auxiliary Output 1 Special Timing Segment 1 (Toggle On/Off then * for Segment 2, # exits)
Default Option ON OFF
OFF I_OFF_I 1 Auxiliary Output Timed in Minutes Auxiliary Output Time in Seconds
OFF I_OFF_I 2 Auxiliary Output to Latch
ON I_ON_I 3 Auxiliary Output to Stop Timing on User Code Entry
OFF I_OFF_I 4 Auxiliary Output to Activate Only Between Closing and Opening Time
OFF I_OFF_I 5 Auxiliary Output to Activate only between Opening and Closing Time
OFF I_OFF_I 6 Invert Auxiliary Output (0 Volts going to 12 Volts)
OFF I_OFF_I 7 Reserved
OFF I_OFF_I 8 Reserved

Auxiliary Output 2 Special Timing Segment 2 (Toggle On/Off then * for Segment 3, # exits)
Default Option ON OFF
OFF I_OFF_I 1 Auxiliary Output Timed in Minutes Auxiliary Output Time in Seconds
OFF I_OFF_I 2 Auxiliary Output to Latch
ON I_ON_I 3 Auxiliary Output to Stop Timing on User Code Entry
OFF I_OFF_I 4 Auxiliary Output to Activate Only Between Closing and Opening Time
OFF I_OFF_I 5 Auxiliary Output to Activate only between Opening and Closing Time
OFF I_OFF_I 6 Invert Auxiliary Output (0 Volts going to 12 Volts)
OFF I_OFF_I 7 Reserved
OFF I_OFF_I 8 Reserved

Auxiliary Output 3 Special Timing Segment 3 (Toggle On/Off then * for Segment 4, # exits)
Default Option ON OFF
OFF I_OFF_I 1 Auxiliary Output Timed in Minutes Auxiliary Output Time in Seconds
OFF I_OFF_I 2 Auxiliary Output to Latch
ON I_ON_I 3 Auxiliary Output to Stop Timing on User Code Entry
OFF I_OFF_I 4 Auxiliary Output to Activate Only Between Closing and Opening Time
OFF I_OFF_I 5 Auxiliary Output to Activate only between Opening and Closing Time
OFF I_OFF_I 6 Invert Auxiliary Output (0 Volts going to 12 Volts)
OFF I_OFF_I 7 Reserved
OFF I_OFF_I 8 Reserved

Auxiliary Output 4 Special Timing Segment 4 (Toggle On/Off then press * to save and exit)
Default Option ON OFF
OFF I_OFF_I 1 Auxiliary Output Timed in Minutes Auxiliary Output Time in Seconds
OFF I_OFF_I 2 Auxiliary Output to Latch
ON I_ON_I 3 Auxiliary Output to Stop Timing on User Code Entry
OFF I_OFF_I 4 Auxiliary Output to Activate Only Between Closing and Opening Time
OFF I_OFF_I 5 Auxiliary Output to Activate only between Opening and Closing Time
OFF I_OFF_I 6 Invert Auxiliary Output (0 Volts going to 12 Volts)
OFF I_OFF_I 7 Reserved
OFF I_OFF_I 8 Reserved

47# Auxiliary Output 1 Event & Time (Enter 1 to 2 digits then * for next, # Exits)
Default
0 I_ _I Event Number for Output 1 (Enter Event Number)
10 I_ _I Timing for Output 1 (1 to 255 Minutes/Seconds (See option 46))
(0 = Output Follows Event)

48# Auxiliary Output 2 Event & Time (Enter 1 to 2 digits then * for next, # Exits)
Default
0 I_ _I Event Number for Output 1 (Enter Event Number)
10 I_ _I Timing for Output 1 (1 to 255 Minutes/Seconds (See option 46))
(0 = Output Follows Event)

49# A uxiliary Output 3 Event & Time (Enter 1 to 2 digits then * for next, # Exits)
Default
0 I_ _I Event Number for Output 1 (Enter Event Number)
10 I_ _I Timing for Output 1 (1 to 255 Minutes/Seconds (See option 46))
(0 = Output Follows Event)

50# Auxiliary Output 4 Event & Time (Enter 1 to 2 digits then * for next, # Exits)
Default
0 I_ _I Event Number for Output 1 (Enter Event Number)
10 I_ _I Timing for Output 1 (1 to 255 Minutes/Seconds (See option 46))
(0 = Output Follows Event)

51# Autotest Control (Enter 1 to 2 digits then * for next, # Exits)
Default
1 I_0_I Autotest Interval select (0 = Autotest in Days, 1 = Autotest in Hours)
24 I_28_I Autotest Interval (1 to 255 Days or 1 to 23 Hours)
2 I_2_I Autotest Time (Hours) (1 to 23 O’Clock)
0 I_0_I Autotest Time (Minutes after the Hour) (0 to 59 minutes)

52# Opening Time (Enter 1 to 2 digits then * for next, # Exits)
Default
8 I_ _I Hour of Opening Time (0 to 24)
0 I_ _I Minutes of the Hour of Opening Time (0 to 59)

53# Closing Time / Auto Arming Time (Enter 1 to 2 digits then * for next, # Exits)
Default
20 I_ _I Hour of Opening Time (0 to 24)
0 I_ _I Minutes of the Hour of Opening Time (0 to 59)

54# Days of Week Partition 1 is Open Segment 1 (Toggle On/Off then * for Segment 2, # exits)
Default Option ON Option OFF
ON I_ _I 1 Open on Sunday Not Open on Sunday
ON I_ _I 2 Open on Monday Not Open on Monday
ON I_ _I 3 Open on Tuesday Not Open on Tuesday
ON I_ _I 4 Open on Wednesday Not Open on Wednesday
ON I_ _I 5 Open on Thursday Not Open on Thursday
ON I_ _I 6 Open on Friday Not Open on Friday
ON I_ _I 7 Open on Saturday Not Open on Saturday
ON I_ _I 8 Reserved

Days of Week Partition 2 is Open Segment 2 (Toggle On/Off then press * to save and exit)
Default Option ON Option OFF
ON I_ _I 1 Open on Sunday Not Open on Sunday
ON I_ _I 2 Open on Monday Not Open on Monday
ON I_ _I 3 Open on Tuesday Not Open on Tuesday
ON I_ _I 4 Open on Wednesday Not Open on Wednesday
ON I_ _I 5 Open on Thursday Not Open on Thursday
ON I_ _I 6 Open on Friday Not Open on Friday
ON I_ _I 7 Open on Saturday Not Open on Saturday
ON I_ _I 8 Reserved

55# Days of Week Partition 1 Auto Arms Segment 1 (Toggle On/Off then * for Segment 2, # exits)
Default Option ON Option OFF
OFF I_ _I 1 Auto Arming on Sunday No Auto Arming on Sunday
OFF I_ _I 2 Auto Arming on Monday No Auto Arming on Monday
OFF I_ _I 3 Auto Arming on Tuesday No Auto Arming on Tuesday
OFF I_ _I 4 Auto Arming on Wednesday No Auto Arming on Wednesday
OFF I_ _I 5 Auto Arming on Thursday No Auto Arming on Thursday
OFF I_ _I 6 Auto Arming on Friday No Auto Arming on Friday
OFF I_ _I 7 Auto Arming on Saturday No Auto Arming on Saturday
OFF I_ _I 8 Disable Retry Timer Enabled

Days of Week Partition 2 Auto Arms Segment 2 (Toggle On/Off then press * to save and exit)
Default Option ON Option OFF
OFF I_ _I 1 Auto Arming on Sunday No Auto Arming on Sunday
OFF I_ _I 2 Auto Arming on Monday No Auto Arming on Monday
OFF I_ _I 3 Auto Arming on Tuesday No Auto Arming on Tuesday
OFF I_ _I 4 Auto Arming on Wednesday No Auto Arming on Wednesday
OFF I_ _I 5 Auto Arming on Thursday No Auto Arming on Thursday
OFF I_ _I 6 Auto Arming on Friday No Auto Arming on Friday
OFF I_ _I 7 Auto Arming on Saturday No Auto Arming on Saturday
OFF I_ _I 8 Disable Retry Timer Enabled

4/2 Format Report Codes (Leave alone) (Enter 1 to 4 digits then * to save and exit)

56# Restore Communication Code I_0_I
57# Bypass Communication Code I_0_I
58# Tamper Communication Code I_0_I
59# Trouble Communication Code I_0_I
60# Sensor Low Battery Communication Code I_0_I
61# Sensor Missing Communication Code I_0_I
62# Duress Communication Code I_0_I_0_I
63# Auxiliary 1 Communication Code I_0_I_0 I
64# Auxiliary 2 Communication Code I_0_I_0_I
65# Keypad Panic Communication Code I_0_I_0_I
66# Keypad Multiple Code Entry Tamper I_0_I_0_I
67# Box Tamper / Box Tamper Restore I_0_I_0_II_0_I_0_I
68# AC Fail / AC Restore I_0_I_0_II_0_I_0_I
69# Low Battery / Low Battery Restore I_0_I_0_II_0_I_0_I
70# AUX Power Short / Power Short Restore I_0_I_0_II_0_I_0_I
71# Bell Tamper / Bell Tamper Restore I_0_I_0_II_0_I_0_I
74# Expander Trouble / Expander Trouble Restore I_0_I_0_II_0_I_0_I
75# Failure to Communicate I_0_I_0_I
76# Log Full Communication Code I_0_I_0_I
77# Opening Communication Code I_0_I
78# Closing Communication Code I_0_I
79# Autotest Communication Code I_0_I_0_I
80# Recent Closing and Exit Alarm I_0_I_0_I
81# Start Programming / End Programming I_0_I_0_II_0_I_0_I
82# End Download I_*_I_*_II_0_I_0_I
83# Cancel Communication Code I_0_I
Partition Settings

88# Part 1 Account Number I_?_I_?_I_?_I_?_I_10_I_ _I (10 = End of number)
(Example: if account is 1234 program as 1* 2* 3* 4* 10*#)
89# Part 2 Account Number I_?_I_?_I_?_I_?_I_10_I_ _I (10 = End of number)

90# Partition 2 Feature Selection Segment 1 (Toggle On/Off then * for segment 2, # exits)
Default Option ON OFF
OFF I_ON_I 1 Quick Arm Enable Disabled
OFF I_ON_I 2 Quick Exit Enable Disabled
ON I_OFF_I 3 Auto Bypass Enable Disabled
OFF I_OFF_I 4 Silent Keypad Panic Disabled
ON I_ON_I 5 Audible Keypad Panic Disabled
OFF I_ON_I 6 Keypad Aux 1 Enable (Fire Panic) Disabled
OFF I_ON_I 7 Keypad Aux 2 Enable (Med Panic) Disabled
OFF I_ON_I 8 Multiple Code Attempt Shutdown Disabled

Segment 2 (Toggle On/Off then * for segment 3, # exits)
Default Option ON OFF
OFF I_OFF_I 1 LED Estinguish Enable Disabled
OFF I_OFF_I 2 User Code Required to Bypass Disabled
OFF I_OFF_I 3 Zone Bypass Sounder Alert Enable Disabled
ON I_ON_I 4 AC Fail/Low Bat Sounder Alert Enable Disabled
OFF I_OFF_I 5 Bypass Toggle Enable Disabled
OFF I_OFF_I 6 Silent Auto Arm Enable Disabled
OFF I_OFF_I 7 Auto Instant Enable Disabled
OFF I_OFF_I 8 Reserved Disabled

Segment 3 (Toggle On/Off then press * to save and exit)
Default Option ON OFF
OFF I_OFF_I 1 Opening/Closing Reporting Enable Disabled
OFF I_OFF_I 2 Zone Bypass Reporting Enable Disabled
OFF I_OFF_I 3 Zone Restore Report Enable Disabled
OFF I_OFF_I 4 Zone Trouble Report Enable Disabled
OFF I_OFF_I 5 Zone Tamper Report Enable Disabled
ON I_ON_I 6 Cancel Report Enable Disabled
ON I_OFF_I 7 Recent Closing Report Enable Disabled (Off if CID format on if SIA)
ON I_ON_I 8 Exit Error Report Enable Disabled

91# Partition 2 Entry/Exit times (Enter each pair of digits * for next, # Exits)
Default
030 I_ _I_ _I_ _I Entry Time 1 (30 to 255 Seconds)
060 I_ _I_ _I_ _I Exit Time 1 (45 to 255 Seconds)
030 I_ _I_ _I_ _I Entry Time 2 (30 to 255 Seconds)
060 I_ _I_ _I_ _I Exit Time 2 (45 to 255 Seconds)
000 I_ _I_ _I_ _I Reserved (* to bypass)
000 I_ _I_ _I_ _I Reserved (* to bypass and exit)

206# Days of Week Partition 1 Auto Disarms Segment 1 (Toggle On/Off then * for Segment 2, # exits)
Default Option ON Option OFF
OFF I_ _I 1 Auto Arming on Sunday No Auto Arming on Sunday
OFF I_ _I 2 Auto Arming on Monday No Auto Arming on Monday
OFF I_ _I 3 Auto Arming on Tuesday No Auto Arming on Tuesday
OFF I_ _I 4 Auto Arming on Wednesday No Auto Arming on Wednesday
OFF I_ _I 5 Auto Arming on Thursday No Auto Arming on Thursday
OFF I_ _I 6 Auto Arming on Friday No Auto Arming on Friday
OFF I_ _I 7 Auto Arming on Saturday No Auto Arming on Saturday
OFF I_ _I 8 Reserved

Days of Week Partition 2 Auto Disarms Segment 2 (Toggle On/Off then press * to save and exit)
Default Option ON Option OFF
OFF I_ _I 1 Auto Arming on Sunday No Auto Arming on Sunday
OFF I_ _I 2 Auto Arming on Monday No Auto Arming on Monday
OFF I_ _I 3 Auto Arming on Tuesday No Auto Arming on Tuesday
OFF I_ _I 4 Auto Arming on Wednesday No Auto Arming on Wednesday
OFF I_ _I 5 Auto Arming on Thursday No Auto Arming on Thursday
OFF I_ _I 6 Auto Arming on Friday No Auto Arming on Friday
OFF I_ _I 7 Auto Arming on Saturday No Auto Arming on Saturday
OFF I_ _I 8 Reserved