45# |
Auxiliary Outputs 1 to 4 Partition Selection |
|
Auxiliary Output 1 Segment 1 |
(Toggle On/Off then * for SSegment 2, # exits) |
Default |
|
Option ON |
Option OFF |
ON |
I_ON_I |
1 Partition 1 |
Not on Partition 1 |
ON |
I_ON_I |
2 Partition 2 |
Not on Partition 2
|
|
Auxiliary Output 2 Segment 2 |
(Toggle On/Off then * for Segment 3, # exits) |
Default |
|
Option ON |
Option OFF |
ON |
I_ON_I |
1 Partition 1 |
Not on Partition 1 |
ON |
I_ON_I |
2 Partition 2 |
Not on Partition 2
|
|
Auxiliary Output 3 Segment 3 |
(Toggle On/Off then * for Segment 4, # exits) |
Default |
|
Option ON |
Option OFF |
ON |
I_ON_I |
1 Partition 1 |
Not on Partition 1 |
ON |
I_ON_I |
2 Partition 2 |
Not on Partition 2
|
|
Auxiliary Output 4 Segment 4 |
(Toggle On/Off then * to save, # exits) |
Default |
|
Option ON |
Option OFF |
ON |
I_ON_I |
1 Partition 1 |
Not on Partition 1 |
ON |
I_ON_I |
2 Partition 2 |
Not on Partition 2
|
46# |
Auxiliary Output 1 Special Timing Segment 1 |
(Toggle On/Off then * for Segment 2, # exits) |
Default |
|
Option ON |
OFF |
OFF |
I_OFF_I |
1 Auxiliary Output Timed in Minutes |
Auxiliary Output Time in Seconds |
OFF |
I_OFF_I |
2 Auxiliary Output to Latch |
ON |
I_ON_I |
3 Auxiliary Output to Stop Timing on User Code Entry |
OFF |
I_OFF_I |
4 Auxiliary Output to Activate Only Between Closing and Opening Time |
OFF |
I_OFF_I |
5 Auxiliary Output to Activate only between Opening and Closing Time |
OFF |
I_OFF_I |
6 Invert Auxiliary Output (0 Volts going to 12 Volts) |
OFF |
I_OFF_I |
7 Reserved |
OFF |
I_OFF_I |
8 Reserved
|
|
Auxiliary Output 2 Special Timing Segment 2 |
(Toggle On/Off then * for Segment 3, # exits) |
Default |
|
Option ON |
OFF |
OFF |
I_OFF_I |
1 Auxiliary Output Timed in Minutes |
Auxiliary Output Time in Seconds |
OFF |
I_OFF_I |
2 Auxiliary Output to Latch |
ON |
I_ON_I |
3 Auxiliary Output to Stop Timing on User Code Entry |
OFF |
I_OFF_I |
4 Auxiliary Output to Activate Only Between Closing and Opening Time |
OFF |
I_OFF_I |
5 Auxiliary Output to Activate only between Opening and Closing Time |
OFF |
I_OFF_I |
6 Invert Auxiliary Output (0 Volts going to 12 Volts) |
OFF |
I_OFF_I |
7 Reserved |
OFF |
I_OFF_I |
8 Reserved
|
|
Auxiliary Output 3 Special Timing Segment 3 |
(Toggle On/Off then * for Segment 4, # exits) |
Default |
|
Option ON |
OFF |
OFF |
I_OFF_I |
1 Auxiliary Output Timed in Minutes |
Auxiliary Output Time in Seconds |
OFF |
I_OFF_I |
2 Auxiliary Output to Latch |
ON |
I_ON_I |
3 Auxiliary Output to Stop Timing on User Code Entry |
OFF |
I_OFF_I |
4 Auxiliary Output to Activate Only Between Closing and Opening Time |
OFF |
I_OFF_I |
5 Auxiliary Output to Activate only between Opening and Closing Time |
OFF |
I_OFF_I |
6 Invert Auxiliary Output (0 Volts going to 12 Volts) |
OFF |
I_OFF_I |
7 Reserved |
OFF |
I_OFF_I |
8 Reserved
|
|
Auxiliary Output 4 Special Timing Segment 4 |
(Toggle On/Off then press * to save and exit) |
Default |
|
Option ON |
OFF |
OFF |
I_OFF_I |
1 Auxiliary Output Timed in Minutes |
Auxiliary Output Time in Seconds |
OFF |
I_OFF_I |
2 Auxiliary Output to Latch |
ON |
I_ON_I |
3 Auxiliary Output to Stop Timing on User Code Entry |
OFF |
I_OFF_I |
4 Auxiliary Output to Activate Only Between Closing and Opening Time |
OFF |
I_OFF_I |
5 Auxiliary Output to Activate only between Opening and Closing Time |
OFF |
I_OFF_I |
6 Invert Auxiliary Output (0 Volts going to 12 Volts) |
OFF |
I_OFF_I |
7 Reserved |
OFF |
I_OFF_I |
8 Reserved
|
47# |
Auxiliary Output 1 Event & Time |
(Enter 1 to 2 digits then * for next, # Exits) |
Default |
0 |
I_ _I |
Event Number for Output 1 |
(Enter Event Number) |
10 |
I_ _I |
Timing for Output 1 |
(1 to 255 Minutes/Seconds (See option 46)) |
|
|
|
(0 = Output Follows Event)
|
48# |
Auxiliary Output 2 Event & Time |
(Enter 1 to 2 digits then * for next, # Exits) |
Default |
0 |
I_ _I |
Event Number for Output 1 |
(Enter Event Number) |
10 |
I_ _I |
Timing for Output 1 |
(1 to 255 Minutes/Seconds (See option 46)) |
|
|
|
(0 = Output Follows Event)
|
49# A |
uxiliary Output 3 Event & Time |
(Enter 1 to 2 digits then * for next, # Exits) |
Default |
0 |
I_ _I |
Event Number for Output 1 |
(Enter Event Number) |
10 |
I_ _I |
Timing for Output 1 |
(1 to 255 Minutes/Seconds (See option 46)) |
|
|
|
(0 = Output Follows Event)
|
50# |
Auxiliary Output 4 Event & Time |
(Enter 1 to 2 digits then * for next, # Exits) |
Default |
0 |
I_ _I |
Event Number for Output 1 |
(Enter Event Number) |
10 |
I_ _I |
Timing for Output 1 |
(1 to 255 Minutes/Seconds (See option 46)) |
|
|
|
(0 = Output Follows Event)
|
51# |
Autotest Control |
(Enter 1 to 2 digits then * for next, # Exits) |
Default |
1 |
I_0_I |
Autotest Interval select |
(0 = Autotest in Days, 1 = Autotest in Hours) |
24 |
I_28_I |
Autotest Interval |
(1 to 255 Days or 1 to 23 Hours) |
2 |
I_2_I |
Autotest Time |
(Hours) (1 to 23 O’Clock) |
0 |
I_0_I |
Autotest Time |
(Minutes after the Hour) (0 to 59 minutes)
|
52# |
Opening Time |
(Enter 1 to 2 digits then * for next, # Exits) |
Default |
8 |
I_ _I |
Hour of Opening Time |
(0 to 24) |
0 |
I_ _I |
Minutes of the Hour of Opening Time |
(0 to 59)
|
53# |
Closing Time / Auto Arming Time |
(Enter 1 to 2 digits then * for next, # Exits) |
Default |
20 |
I_ _I |
Hour of Opening Time |
(0 to 24) |
0 |
I_ _I |
Minutes of the Hour of Opening Time |
(0 to 59)
|
54# |
Days of Week Partition 1 is Open Segment 1 |
(Toggle On/Off then * for Segment 2, # exits) |
Default |
|
Option ON |
Option OFF |
ON |
I_ _I |
1 Open on Sunday |
Not Open on Sunday |
ON |
I_ _I |
2 Open on Monday |
Not Open on Monday |
ON |
I_ _I |
3 Open on Tuesday |
Not Open on Tuesday |
ON |
I_ _I |
4 Open on Wednesday |
Not Open on Wednesday |
ON |
I_ _I |
5 Open on Thursday |
Not Open on Thursday |
ON |
I_ _I |
6 Open on Friday |
Not Open on Friday |
ON |
I_ _I |
7 Open on Saturday |
Not Open on Saturday |
ON |
I_ _I |
8 Reserved
|
|
Days of Week Partition 2 is Open Segment 2 |
(Toggle On/Off then press * to save and exit) |
Default |
|
Option ON |
Option OFF |
ON |
I_ _I |
1 Open on Sunday |
Not Open on Sunday |
ON |
I_ _I |
2 Open on Monday |
Not Open on Monday |
ON |
I_ _I |
3 Open on Tuesday |
Not Open on Tuesday |
ON |
I_ _I |
4 Open on Wednesday |
Not Open on Wednesday |
ON |
I_ _I |
5 Open on Thursday |
Not Open on Thursday |
ON |
I_ _I |
6 Open on Friday |
Not Open on Friday |
ON |
I_ _I |
7 Open on Saturday |
Not Open on Saturday |
ON |
I_ _I |
8 Reserved
|
55# |
Days of Week Partition 1 Auto Arms Segment 1 |
(Toggle On/Off then * for Segment 2, # exits) |
Default |
|
Option ON |
Option OFF |
OFF |
I_ _I |
1 Auto Arming on Sunday |
No Auto Arming on Sunday |
OFF |
I_ _I |
2 Auto Arming on Monday |
No Auto Arming on Monday |
OFF |
I_ _I |
3 Auto Arming on Tuesday |
No Auto Arming on Tuesday |
OFF |
I_ _I |
4 Auto Arming on Wednesday |
No Auto Arming on Wednesday |
OFF |
I_ _I |
5 Auto Arming on Thursday |
No Auto Arming on Thursday |
OFF |
I_ _I |
6 Auto Arming on Friday |
No Auto Arming on Friday |
OFF |
I_ _I |
7 Auto Arming on Saturday |
No Auto Arming on Saturday |
OFF |
I_ _I |
8 Disable Retry Timer |
Enabled
|
|
Days of Week Partition 2 Auto Arms Segment 2 |
(Toggle On/Off then press * to save and exit) |
Default |
|
Option ON |
Option OFF |
OFF |
I_ _I |
1 Auto Arming on Sunday |
No Auto Arming on Sunday |
OFF |
I_ _I |
2 Auto Arming on Monday |
No Auto Arming on Monday |
OFF |
I_ _I |
3 Auto Arming on Tuesday |
No Auto Arming on Tuesday |
OFF |
I_ _I |
4 Auto Arming on Wednesday |
No Auto Arming on Wednesday |
OFF |
I_ _I |
5 Auto Arming on Thursday |
No Auto Arming on Thursday |
OFF |
I_ _I |
6 Auto Arming on Friday |
No Auto Arming on Friday |
OFF |
I_ _I |
7 Auto Arming on Saturday |
No Auto Arming on Saturday |
OFF |
I_ _I |
8 Disable Retry Timer |
Enabled
|