23# |
Feature Selection Segment 1 |
(Toggle On/Off then * for segment 2, # exits) |
Default |
|
Option ON |
OFF |
OFF |
I_ON_I |
1 Quick Arm Enable |
Disabled |
OFF |
I_ON_I |
2 Quick Exit Enable |
Disabled |
ON |
I_OFF_I |
3 Auto Bypass Enable |
Disabled |
OFF |
I_OFF_I |
4 Silent Keypad Panic |
Disabled |
ON |
I_ON_I |
5 Audible Keypad Panic |
Disabled |
OFF |
I_ON_I |
6 Keypad Aux 1 Enable (Fire Panic) |
Disabled |
OFF |
I_ON_I |
7 Keypad Aux 2 Enable (Medical Panic) |
Disabled |
OFF |
I_ON_I |
8 Multi Code Attempt Shutdown |
Disabled
|
|
Segment 2 |
(Toggle On/Off then * for segment 3, # exits) |
Default |
|
Option ON |
OFF |
OFF |
I_OFF_I |
1 LED Estinguish Enable |
Disabled |
OFF |
I_OFF_I |
2 User Code Required to Bypass |
Disabled |
OFF |
I_OFF_I |
3 Zone Bypass Sounder Alert Enable |
Disabled |
ON |
I_ON_I |
4 AC Fail/Low Bat Sounder Alert Enable |
Disabled |
OFF |
I_OFF_I |
5 Bypass Toggle Enable |
Disabled |
OFF |
I_OFF_I |
6 Silent Auto Arm Enable |
Disabled |
OFF |
I_OFF_I |
7 Auto Instant Enable |
Disabled |
OFF |
I_ON_I |
8 Instant Mode Toggle Enable |
Disabled
|
|
Segment 3 |
(Toggle On/Off then * for segment 4, # exits) |
Default |
|
Option ON |
OFF |
OFF |
I_OFF_I |
1 Opening/Closing Reporting Enable |
Disabled |
OFF |
I_OFF_I |
2 Zone Bypass Reporting Enable |
Disabled |
OFF |
I_OFF_I |
3 Zone Restore Report Enable |
Disabled |
OFF |
I_OFF_I |
4 Zone Trouble Report Enable |
Disabled |
OFF |
I_OFF_I |
5 Zone Tamper Report Enable |
Disabled |
ON |
I_ON_I |
6 Cancel Report Enable |
Disabled |
ON |
I_OFF_I |
7 Recent Closing Report Enable |
Disabled (Off if CID Format on if SIA) |
ON |
I_ON_I |
8 Exit Error Report Enable |
Disabled
|
|
Segment 4 |
(Toggle On/Off then * for segment 5, # exits) |
Default |
|
Option ON |
OFF |
OFF |
I_OFF_I |
1 Late Close/Early Open Enable |
Disabled |
OFF |
I_OFF_I |
2 Auto Arm Stay Mode |
Auto Arm Away Mode |
OFF |
I_OFF_I |
3 Night Mode Instant |
Night Mode Stay |
OFF |
I_OFF_I |
4 Reserved |
OFF |
I_OFF_I |
5 Reserved |
OFF |
I_OFF_I |
6 Reserved |
OFF |
I_OFF_I |
7 Reserved |
OFF |
I_OFF_I |
8 Reserved
|
|
Segment 5 |
(Toggle On/Off then press * to save and exit) |
|
Reserved
|
24# |
Feature Selection |
(Enter each pair of digits * for next, # Exits) |
Default |
030 |
I_ _I_ _I_ _I |
Entry Time 1 |
(30 to 255 Seconds) |
060 |
I_ _I_ _I_ _I |
Exit Time 1 |
(45 to 255 Seconds) |
030 |
I_ _I_ _I_ _I |
Entry Time 2 |
(30 to 255 Seconds) |
060 |
I_ _I_ _I_ _I |
Exit Time 2 |
(45 to 255 Seconds) |
000 |
I_ _I_ _I_ _I |
Reserved |
(* to bypasss) |
000 |
I_ _I_ _I_ _I |
Reserved |
(* to bypasss and exit)
|
25# |
Zones 1 to 8 type |
(Enter each digit then * for next, # Exits) |
Default |
3 |
I_ _I |
1 Zone 1 |
|
5 |
I_ _I |
2 Zone 2 |
6 |
I_ _I |
3 Zone 3 |
6 |
I_ _I |
4 Zone 4 |
6 |
I_ _I |
5 Zone 5 |
6 |
I_ _I |
6 Zone 6 |
6 |
I_ _I |
7 Zone 7 |
6 |
I_ _I |
8 Zone 8
|
37# |
Siren & System Supervision Segment 1 |
(Toggle On/Off then * for Segment 2, # exits) |
Default |
|
Option ON |
OFF |
ON |
I_ON_I |
1 Siren Sounds for Line Cut Armed |
Disabled |
ON |
I_OFF_I |
2 Siren Sounds for Line Cut Disarmed |
Disabled |
OFF |
I_OFF_I |
3 Siren Blast at Arming |
Disabled |
OFF |
I_OFF_I |
4 Siren Blast at Exit Delay Expiration |
Disabled |
OFF |
I_OFF_I |
5 Siren Blast at Closing Kissoff |
Disabled |
OFF |
I_OFF_I |
6 Siren Sounds on Cross Zone Verification |
Disabled |
ON |
I_ON_I |
7 Siren Sounds for a Tamper |
Disabled |
OFF |
I_OFF_I |
8 Siren Sounds Keyswitch/Fob Arm/Disarm |
Disabled
|
|
Siren & System Supervision Segment 2 |
(Toggle On/Off then * for Segment 3, # exits) |
Default |
|
Option ON |
OFF |
OFF |
I_OFF_I |
1 Convert Siren Driver to Voltage Out |
Disabled (Can blow speakers if hooked up) |
OFF |
I_OFF_I |
2 Siren Sounds for Expander Trouble |
Disabled |
OFF |
I_OFF_I |
3 Immediate Restore by Zone |
Disabled |
OFF |
I_OFF_I |
4 Dynamic Battery Test upon Arming |
Disabled |
OFF |
I_OFF_I |
5 Battery Missing Test every 12 Seconds |
Disabled |
ON |
I_ON_I |
6 Manual Bell Test by * 4 Test Function |
Disabled |
OFF |
I_ON_I |
7 Manual Com Test by * 4 Test Function |
Disabled |
OFF |
I_OFF_I |
8 Box Tamper Enabled |
Disabled
|
|
Siren & System Supervision Segment 3 |
(Toggle On/Off then * for Segment 4, # exits) |
Default |
|
Option ON |
OFF |
OFF |
I_OFF_I |
1 Box Tamper Report Enabled |
Disabled |
OFF |
I_ON_I |
2 AC Fail Report Enabled |
Disabled |
OFF |
I_ON_I |
3 Low Battery Report Enabled |
Disabled |
OFF |
I_ON_I |
4 Aux Power Over Current Report Enabled |
Disabled |
OFF |
I_ON_I |
5 Siren Supervision Report Enabled |
Disabled |
OFF |
I_OFF_I |
6 Phone Line Cut Report Enabled |
Disabled |
OFF |
I_OFF_I |
7 Reserved |
OFF |
I_ON_I |
8 Expander Trouble Report Enabled |
Disabled
|
|
Siren & System Supervision Segment 4 |
(Toggle On/Off then * for Segment 5, # exits) |
Default |
|
Option ON |
OFF |
OFF |
I_ON_I |
1 Fail To Communicate Report Enabled |
Disabled |
OFF |
I_OFF_I |
2 Log Full Report Enabled |
Disabled |
OFF |
I_ON_I |
3 Autotest Report Enabled |
Disabled |
OFF |
I_OFF_I |
4 Start & End Programming Report Enabled |
Disabled |
OFF |
I_OFF_I |
5 End Download Report Enabled |
Disabled |
OFF |
I_ON_I |
6 Sensor Low Battery Report Enabled |
Disabled |
OFF |
I_ON_I |
7 Sensor Missing Report Enabled |
Disabled |
OFF |
I_OFF_I |
8 First to Open/Last to Close |
Disabled
|
|
Siren & System Supervision Segment 5 |
(Toggle On/Off then * for Segment 6, # exits) |
Default |
|
Option ON |
OFF |
OFF |
I_OFF_I |
1 Lost Clock Service LED Enable |
Disabled |
OFF |
I_OFF_I |
2 Zone Doubling Enabled |
Disabled |
OFF |
I_OFF_I |
3 Disable On-Board Four Zones |
Disabled |
OFF |
I_OFF_I |
4 Enable 2 Trip on Cross Zone for Alarm |
Disabled |
OFF |
I_OFF_I |
5 Disable Bypass Report on Force Arm |
Disabled |
OFF |
I_OFF_I |
6 Reserved |
OFF |
I_OFF_I |
7 Clock Uses Internal Crystal |
Disabled |
OFF |
I_OFF_I |
8 Disable Temporal Siren on Fire Alarm |
Disabled
|
|
Siren & System Supervision Segment 6 |
(Toggle On/Off then * for Segment 7, # exits) |
Default |
|
Option ON |
OFF |
OFF |
I_OFF_I |
1 Reserved |
OFF |
I_OFF_I |
2 Reserved |
OFF |
I_OFF_I |
3 Zone Activity in Hours |
Zone Activity in Days |
OFF |
I_OFF_I |
4 Enable Daylight Savings Time |
(DST) Disabled |
OFF |
I_OFF_I |
5 Reserved |
OFF |
I_OFF_I |
6 Disable Clean me Report |
Enable Clean me Report |
OFF |
I_OFF_I |
7 Disable Start/End Test Report |
Enable Start/End Test Report |
OFF |
I_OFF_I |
8 Reserved
|
|
Siren & System Supervision Segment 7 |
(Toggle On/Off then press * to save and exit) |
|
Reserved
|