Download Callback |
* 98 = panel calls download computer (User Code after may be required) |
Download Answer |
* 99 = panel picks up while phone ringing (User Code after may be required) |
Enter Program |
1. Press * + 8 (STAY/CHIME/EXIT/BYPASS/CANCEL lights will flash)
2. 9713 (default) (STAY/CHIME/EXIT/BYPASS/CANCEL lights flash, SERVICE turns ON)
3. 0 + # (STAY CHIME EXIT BYPASS CANCEL, SERVICE, ARMED turns ON)
(If incorrect Install code entered STAY/CHIME/EXIT/BYPASS/CANCEL will continue flashing)
|
Move to Location |
Location + # |
Enter Data |
Enter data + * which saves and moves to next digit within location, # exits at any time
Example: To change Receiver Phone 1
1. Press 0 + # (Moves to location 0)
2. Enter 15 + * (Selects Touch Tone dialing)
3. Enter 1 * 8 * 0 * 0 * etc (End Phone Number with 14 + *)
4. Press # to exit location (Moves back to start of programming)
|
Exit Program |
Press EXIT key twice |
Factory Default |
910 # while in programming (Last resort) |
Enroll Modules |
Modules enroll automatically when exiting programming. |
Hex Program |
10 = A 11 = B 12 = C 13 = D 14 = E 15 = F |
[Click HERE for Keypad Programming] |
|
|
0# |
Receiver Number 1 (20 Digits) |
I_F_I_1_I_8_I_?_I_?_I_?_I_?_I_?_I_?_I_?_I_?_I_E_I |
|
11 (B) = * |
(Program as 15 * 1 * 8 * 0 * 0 * then 14 * # to end) |
12 (C) = # |
|
13 (D) = 4 Second Pause |
(Don’t use 10’s for 0’s) |
14 (E) = End of Number |
|
15 (F) = Touch Tone |
|
1# |
Account Number (6 digits) |
I_?_I_?_I_?_I_?_I_10_I_ _I (Enter 4 digits, 10 ends, # exits)
(Example: if account is 1234 program as 1* 2* 3* 4* 10*#)
|
2# |
Report Format |
I_14_I |
(Enter digit then * to save and exit) |
0 = Communicator Disabled
1 = Universal 4/2
2 = 3/1 or 4/1 Fast
3 = Reserved
4 = Pager
5 = 3/1 or 4/1 slow (1800hz transmit, 2300hz handshake 20pps)
6 = 3/1 or 4/1 slow (1800hz transmit, 1400hz handshake 20pps)
7 = 3/1 or 4/1 fast (1800hz transmit, 2300hz handshake 40pps)
8 = 3/1 or 4/1 fast (1800hz transmit, 1400hz handshake 40pps)
9 = 3/1 or 4/1 fast w/parity (1800hz transmit, 2300hz handshake 40pps)
10 = 3/1 or 4/1 fast w/parity (1800hz transmit, 1400hz handshake 40pps)
11 = 4/2 Express
12 = 4/2 Fast (1900hz transmit, 1400hz handshake 20pps)
13 = Contact ID
14 = SIA
15 = Custom (See location 18)
|
|
3# |
Dial Attempts/Backup Control |
I_8_I_1_I |
(Enter digit then * to save) |
(Enter 1 in second digit to only dial first numberthen * to save and exit)
|
4# |
Events to Report Phone 1 Segment 1 |
(Toggle On/Off then * for segment 2, # exits) |
Default |
|
Option ON |
OFF |
ON |
I_ON_I |
1 Alarms and Restores |
Disabled |
ON |
I_OFF_I |
2 Opening/Closings |
Disabled |
ON |
I_OFF_I |
3 Bypass and Restores |
Disabled |
ON |
I_ON_I |
4 Zone Trouble and Restores |
Disabled |
ON |
I_ON_I |
5 AC Failure, Low Battery and Restores |
Disabled |
ON |
I_ON_I |
6 Siren Trouble and Restores |
Disabled |
ON |
I_ON_I |
7 Test Reports |
Disabled |
ON |
I_OFF_I |
8 Start/End prog and Download Finished |
Disabled
|
|
Events to Report Phone 1 Segment 2 |
(Toggle On/Off then press * to save and exit) |
Default |
|
Option ON |
OFF |
ON |
I_ON_I |
1 Tampers and Restores |
Disabled |
ON |
I_ON_I |
2 Aux Power Over Current and Restore |
Disabled |
ON |
I_ON_I |
3 Sensor Missing and Restore |
Disabled |
ON |
I_ON_I |
4 Sensor Low Battery and Restore |
Disabled |
ON |
I_ON_I |
5 Expander Trouble and Restore |
Disabled |
ON |
I_ON_I |
6 Failure To Communicate |
Disabled |
ON |
I_ON_I |
7 Reserved |
ON |
I_ON_I |
8 Reserved |
|
6# |
Receiver Number 2 (20 Digits) |
I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I |
7# |
Account Number 2 (6 digits) |
I_ _I_ _I_ _I_ _I_ _I_ _I (Not Used) |
8# |
Report Format Phone 2 |
I_ _I |
(Not Used) |
9# |
Dial Attempts Phone 2 |
I_ _I_ _I |
(Not Used)
|
10# |
Events to Report Phone 2 Segment 1 |
(Toggle On/Off then * for segment 2, # exits) |
Default |
|
Option ON |
OFF |
ON |
I_ON_I |
1 Alarms and Restores |
Disabled |
ON |
I_OFF_I |
2 Opening/Closings |
Disabled |
ON |
I_OFF_I |
3 Bypass and Restores |
Disabled |
ON |
I_ON_I |
4 Zone Trouble and Restores |
Disabled |
ON |
I_ON_I |
5 AC Failure, Low Battery and Restores |
Disabled |
ON |
I_ON_I |
6 Siren Trouble and Restores |
Disabled |
ON |
I_ON_I |
7 Test Reports |
Disabled |
ON |
I_OFF_I |
8 Start/End prog and Download Finished |
Disabled
|
|
Events to Report Phone 2 Segment 2 |
(Toggle On/Off then press * to save and exit) |
Default |
|
Option ON |
OFF |
ON |
I_ON_I |
1 Tampers and Restores |
Disabled |
ON |
I_ON_I |
2 Aux Power Over Current and Restore |
Disabled |
ON |
I_ON_I |
3 Sensor Missing and Restore |
Disabled |
ON |
I_ON_I |
4 Sensor Low Battery and Restore |
Disabled |
ON |
I_ON_I |
5 Expander Trouble and Restore |
Disabled |
ON |
I_ON_I |
6 Failure To Communicate |
Disabled |
ON |
I_ON_I |
7 Reserved |
ON |
I_ON_I |
8 Reserved |
|
12# |
Receiver Number 3 (20 Digits) |
I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I |
13# |
Account Number 3 (6 digits) |
I_ _I_ _I_ _I_ _I_ _I_ _I
(Enter 4 digits then 10 to end * saves, # exits)
|
14# |
Report Format Phone 3 |
I_ _I |
(Enter digit then * to save and exit) |
15# |
Dial Attempts Phone 3 |
I_ _I_ _I |
(Enter digit then * to save and exit)
|
16# |
Events to Report Phone 3 Segment 1 |
(Toggle On/Off then * for segment 2, # exits) |
Default
|
Option ON |
OFF |
ON |
I_ON_I |
1 Alarms and Restores |
Disabled |
ON |
I_OFF_I |
2 Opening/Closings |
Disabled |
ON |
I_OFF_I |
3 Bypass and Restores |
Disabled |
ON |
I_ON_I |
4 Zone Trouble and Restores |
Disabled |
ON |
I_ON_I |
5 AC Failure, Low Battery and Restores |
Disabled |
ON |
I_ON_I |
6 Siren Trouble and Restores |
Disabled |
ON |
I_ON_I |
7 Test Reports |
Disabled |
ON |
I_OFF_I |
8 Start/End prog and Download Finished |
Disabled
|
|
Events to Report Phone 3 Segment 2 |
(Toggle On/Off then press * to save and exit) |
Default |
|
Option ON |
OFF |
ON |
I_ON_I |
1 Tampers and Restores |
Disabled |
ON |
I_ON_I |
2 Aux Power Over Current and Restore |
Disabled |
ON |
I_ON_I |
3 Sensor Missing and Restore |
Disabled |
ON |
I_ON_I |
4 Sensor Low Battery and Restore |
Disabled |
ON |
I_ON_I |
5 Expander Trouble and Restore |
Disabled |
ON |
I_ON_I |
6 Failure To Communicate |
Disabled |
ON |
I_ON_I |
7 Reserved |
ON |
I_ON_I |
8 Reserved
|
18# |
Format Override Segment 1 |
(Toggle On/Off then * for segment 2, # exits) |
Default |
|
Option ON |
OFF |
OFF |
I_OFF_I |
1 1800Hz Transmit |
1900Hz Transmit |
OFF |
I_OFF_I |
2 2300Hz Handshake |
1400Hz Handshake |
OFF |
I_OFF_I |
3 Checksum Parity |
Double Round Parity |
OFF |
I_OFF_I |
4 2-Digit Event Code |
1-Digit Event Code |
OFF |
I_OFF_I |
5 Reserved |
OFF |
I_OFF_I |
6 Reserved |
OFF |
I_OFF_I |
7 20 PPS |
10 or 40 PPS |
OFF |
I_OFF_I |
8 10 PPS |
20 or 40 PPS
|
|
Format Override Segments 2 |
(Toggle On/Off then * for segment 3, # exits) |
Default |
|
Option ON |
OFF |
OFF |
I_OFF_I |
1 Pager Format |
Disabled |
OFF |
I_OFF_I |
2 1400/2300 Handshake |
Disabled |
OFF |
I_OFF_I |
3 Reserved |
Disabled |
OFF |
I_OFF_I |
4 Reserved |
Disabled |
OFF |
I_OFF_I |
5 Contact ID |
Disabled |
OFF |
I_OFF_I |
6 SIA |
Disabled |
OFF |
I_OFF_I |
7 Contact ID or 4 + 3 |
Disabled |
OFF |
I_OFF_I |
8 DTMF |
Disabled
|
|
|
Format Override Segments 3
Reserved
|
(Toggle On/Off then * for segment 4, # exits)
|
|
Format Override Segments 4
Reserved
|
(Toggle On/Off then * to save and exit)
|
19# |
Download Access Code |
I_8_I_4_I_8_I_0_I_0_I_0_I_0_I_0_I
(Program as 8* 4* 8* 0* 0* 0* 0* 0* then # to exit)
|
20# |
Rings to Answer Download |
I_8_I |
(Then press * to save and exit)
1-15, 0 to disable
|
21# |
Download Control |
(Toggle On/Off then press * to save and exit) |
Default |
|
Option ON |
OFF |
OFF |
I_ON_I |
1 Two Call Answering Machine Defeat Disabled |
OFF |
I_OFF_I |
2 Reserved Disabled |
OFF |
I_OFF_I |
3 Callback Enabled Disabled |
OFF |
I_OFF_I |
4 Shut Down Control Panel Disabled |
OFF |
I_OFF_I |
5 Lock Out Local Programming Disabled |
OFF |
I_OFF_I |
6 Lock Out Communicator Programming Disabled |
OFF |
I_OFF_I |
7 Lockout Download Section* Disabled |
OFF |
I_OFF_I |
8 Enable Callback at AutoTest Disabled |
|
22# |
Callback Phone Number |
I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I
|
23# |
Feature Selection Segment 1 |
(Toggle On/Off then * for segment 2, # exits) |
Default |
|
Option ON |
OFF |
OFF |
I_ON_I |
1 Quick Arm Enable |
Disabled |
OFF |
I_ON_I |
2 Quick Exit Enable |
Disabled |
ON |
I_OFF_I |
3 Auto Bypass Enable |
Disabled |
OFF |
I_OFF_I |
4 Silent Keypad Panic |
Disabled |
ON |
I_ON_I |
5 Audible Keypad Panic |
Disabled |
OFF |
I_ON_I |
6 Keypad Auxiliary 1 Enable (Fire Panic) |
Disabled |
OFF |
I_ON_I |
7 Keypad Auxiliary 2 Enable (Medical Panic) |
Disabled |
OFF |
I_ON_I |
8 Multiple Code Attempt Shutdown Enable |
Disabled
|
|
Segment 2 |
(Toggle On/Off then * for segment 3, # exits) |
Default |
|
Option ON |
OFF |
OFF |
I_OFF_I |
1 LED Estinguish Enable |
Disabled |
OFF |
I_OFF_I |
2 User Code Required to Bypass |
Disabled |
OFF |
I_OFF_I |
3 Zone Bypass Sounder Alert Enable |
Disabled |
ON |
I_ON_I |
4 AC Fail/Low Bat Sounder Alert Enable |
Disabled |
OFF |
I_OFF_I |
5 Bypass Toggle Enable |
Disabled |
OFF |
I_OFF_I |
6 Silent Auto Arm Enable |
Disabled |
OFF |
I_OFF_I |
7 Auto Instant Enable |
Disabled |
OFF |
I_OFF_I |
8 Reserved |
Disabled
|
|
Segment 3 |
(Toggle On/Off then press * to save and exit) |
Default |
|
Option ON |
OFF |
OFF |
I_OFF_I |
1 Opening/Closing Reporting Enable |
Disabled |
OFF |
I_OFF_I |
2 Zone Bypass Reporting Enable |
Disabled |
OFF |
I_OFF_I |
3 Zone Restore Report Enable |
Disabled |
OFF |
I_OFF_I |
4 Zone Trouble Report Enable |
Disabled |
OFF |
I_OFF_I |
5 Zone Tamper Report Enable |
Disabled |
ON |
I_ON_I |
6 Cancel Report Enable |
Disabled |
ON |
I_OFF_I |
7 Recent Closing Report Enable |
Disabled (Off if CID format on if SIA) |
ON |
I_ON_I |
8 Exit Error Report Enable |
Disabled
|
24# |
Feature Selection |
(Enter each pair of digits * for next, # Exits) |
Default |
030 |
I_ _I_ _I_ _I |
Entry Time 1 |
(30 to 255 Seconds) |
060 |
I_ _I_ _I_ _I |
Exit Time 1 |
(45 to 255 Seconds) |
030 |
I_ _I_ _I_ _I |
Entry Time 2 |
(30 to 255 Seconds) |
060 |
I_ _I_ _I_ _I |
Exit Time 2 |
(45 to 255 Seconds)
|
25# |
Zones 1 to 8 Type |
(Enter each digit then * for next, # Exits) |
Default |
3 |
I_ _I |
1 Zone 1 |
|
5 |
I_ _I |
2 Zone 2 |
6 |
I_ _I |
3 Zone 3 |
6 |
I_ _I |
4 Zone 4 |
6 |
I_ _I |
5 Zone 5 |
6 |
I_ _I |
6 Zone 6 |
|
6 |
I_ _I |
7 Zone 7 |
6 |
I_ _I |
8 Zone 8
|
37# |
Siren & System Supervision Segment 1 |
(Toggle On/Off then * for Segment 2, # exits) |
Default |
|
Option ON |
OFF |
OFF |
I_OFF_I |
1 Reserved |
OFF |
I_OFF_I |
2 Reserved |
OFF |
I_OFF_I |
3 Siren Blast at Arming |
Disabled |
OFF |
I_OFF_I |
4 Siren Blast at Exit Delay Expiration Disabled |
OFF |
I_OFF_I |
5 Siren Blast at Closing Kissoff |
Disabled |
OFF |
I_OFF_I |
6 Siren Sounds on Cross Zone Verification |
Disabled |
ON |
I_ON_I |
7 Siren Sounds for a Tamper |
Disabled |
OFF |
I_OFF_I |
8 Siren Sounds for Wireless Arm/Disarm |
Disabled
|
|
Siren & System Supervision Segment 2 |
(Toggle On/Off then * for Segment 3, # exits) |
Default |
|
Option ON |
OFF |
OFF |
I_OFF_I |
1 Convert Siren Driver to Voltage Out |
Disabled |
OFF |
I_OFF_I |
2 Siren Sounds for Expander Trouble |
Disabled |
OFF |
I_OFF_I |
3 Immediate Restore by Zone |
Disabled |
OFF |
I_OFF_I |
4 Dynamic Battery Test upon Arming |
Disabled |
OFF |
I_OFF_I |
5 Battery Missing Test every 12 Seconds |
Disabled |
ON |
I_ON_I |
6 Manual Bell Test by * 4 Test Function |
Disabled |
OFF |
I_ON_I |
7 Manual Com Test by * 4 Test Function |
Disabled |
OFF |
I_OFF_I |
8 Box Tamper Enabled |
Disabled
|
|
Siren & System Supervision Segment 3 |
(Toggle On/Off then * for Segment 4, # exits) |
Default |
|
Option ON |
OFF |
OFF |
I_OFF_I |
1 Box Tamper Report Enabled |
Disabled |
OFF |
I_ON_I |
2 AC Fail Report Enabled |
Disabled |
OFF |
I_ON_I |
3 Low Battery Report Enabled |
Disabled |
OFF |
I_ON_I |
4 Aux Power Over Current Report Enabled |
Disabled |
OFF |
I_ON_I |
5 Siren Supervision Report Enabled |
Disabled |
OFF |
I_OFF_I |
6 Reserved |
OFF |
I_OFF_I |
7 Reserved |
OFF |
I_ON_I |
8 Expander Trouble Report Enabled |
Disabled
|
|
Siren & System Supervision Segment 4 |
(Toggle On/Off then * for Segment 5, # exits) |
Default |
|
Option ON |
OFF |
OFF |
I_ON_I |
1 Fail To Communicate Report Enabled |
Disabled |
OFF |
I_OFF_I |
2 Log Full Report Enabled |
Disabled |
OFF |
I_ON_I |
3 Autotest Report Enabled |
Disabled |
OFF |
I_OFF_I |
4 Start & End Programming Report Enabled |
Disabled |
OFF |
I_OFF_I |
5 End Download Report Enabled |
Disabled |
OFF |
I_ON_I |
6 Sensor Low Battery Report Enabled |
Disabled |
OFF |
I_ON_I |
7 Sensor Missing Report Enabled |
Disabled |
OFF |
I_OFF_I |
8 Reserved
|
|
Siren & System Supervision Segment 5 |
(Toggle On/Off then press * to save and exit) |
Default |
|
Option ON |
OFF |
OFF |
I_OFF_I |
1 Lost Clock Service LED Enable |
Disabled |
OFF |
I_OFF_I |
2 Zone Doubling Enabled |
Disabled |
OFF |
I_OFF_I |
3 Disable On-Board Four Zones |
Disabled |
OFF |
I_OFF_I |
4 Enable 2 Trip on Cross Zone for Alarm |
Disabled |
OFF |
I_OFF_I |
5 Disable Bypass Report on Force Arm |
Disabled |
OFF |
I_OFF_I |
6 Silent Exit Enabled |
Disabled |
OFF |
I_OFF_I |
7 Clock Uses Internal Crystal |
Disabled |
OFF |
I_OFF_I |
8 Disable Temporal Siren on Fire Alarm |
Disabled |
|
38# |
Swinger Shutdown Count |
I_3_I
|
39# |
Keypad Sounder Control |
(Toggle On/Off then press * to save and exit) |
Default |
|
Option ON |
OFF |
ON |
I_OFF_I |
1 Reserved |
ON |
I_OFF_I |
2 Reserved |
OFF |
I_OFF_I |
3 Keypad Sounds on AC Failure |
Disabled |
OFF |
I_OFF_I |
4 Keypad Sounds on Low Battery |
Disabled |
OFF |
I_OFF_I |
5 Keypad Sounds on Cross Zone Trip |
Disabled |
OFF |
I_ON_I |
6 Keypad Sounds For Tamper Alarms |
Disabled |
OFF |
I_OFF_I |
7 Reserved |
OFF |
I_OFF_I |
8 Keypad Sounds For Expander Trouble |
Disabled
|
40# |
System Timers |
(Enter each digit then * for next, # Exits) |
Default |
0 |
I_ _I |
Dynamic Battery Test Duration |
(0 to 255 minutes) |
5 |
I_ _I |
AC Fail Report Delay |
(0 to 255 minutes) |
60 |
I_ _I |
Power Up Delay |
(0 to 60 seconds) |
8 |
I_ _I |
Siren Timeout |
(1 to 255 minutes) |
0 |
I_ _I |
Reserved |
5 |
I_ _I |
Cross Zone Time |
(0 to 255 minutes) |
3 |
I_ _I |
Chime Time |
(0 to 255 x50ms) |
30 |
I_ _I |
Dialer Delay |
(15 to 255 seconds) |
0 |
I_ _I |
Fire Alarm Verification Time |
(120 to 255 seconds) |
0 |
I_ _I |
Listen In Time |
(0 to 255 seconds)
|
41# |
User Code Requirements |
(Toggle On/Off then press * to save and exit) |
Default |
|
Option ON |
OFF |
OFF |
I_OFF_I |
1 Enable 6-Digit User Codes |
Disabled |
OFF |
I_OFF_I |
2 User Code Required for *98 & *99 |
Disabled |
OFF |
I_OFF_I |
3 Auto Cancel/Abort Enabled |
Disabled |
OFF |
I_OFF_I |
4 Walk Test Mode Enabled |
Disabled |
OFF |
I_OFF_I |
5 Reserved |
OFF |
I_OFF_I |
6 Reserved |
OFF |
I_OFF_I |
7 Reserved |
OFF |
I_OFF_I |
8 Reserved
|
|
42# |
Go To Program Code |
I_4_I_8_I_5_I_0_I_10_I_ _I
(Program as 4 * 8 * 5 * 0 * 10 * then # to exit)
|
43# |
Go To Program Options |
(Toggle On/Off then press * to save and exit) |
Default |
|
Option ON |
OFF |
OFF |
I_OFF_I |
1 Reserved |
OFF |
I_OFF_I |
2 Program Code is Arm Only Code D |
isabled |
OFF |
I_OFF_I |
3 Program Code is Arm Only after Closing |
Disabled |
OFF |
I_OFF_I |
4 Program Code is Master Code* |
Disabled |
OFF |
I_OFF_I |
5 Program Code is Arm/Disarm Code |
Disabled |
OFF |
I_OFF_I |
6 Program Code Bypasses Zones |
Disabled |
OFF |
I_OFF_I |
7 Program Code Sends O/C Reports |
Disabled |
OFF |
I_OFF_I |
8 Reserved |
* enable in case Master Code is forgotten, use Installer Code to add new Master Code |
|
44# |
Duress Code |
I_2_I_5_I_8_I_0_I_10_I_ _I
(Program as 2 * 5 * 8 * 0 * 10 * then # to exit)
|
46# |
Aux Output 1 Special Timing Segment 1 |
(Toggle On/Off then * for Segment 2, # exits) |
Default |
|
Option ON |
OFF |
OFF |
I_OFF_I |
1 Auxiliary Output Timed in Minutes |
Auxiliary Output Time in Seconds |
OFF |
I_OFF_I |
2 Auxiliary Output to Latch |
ON |
I_ON_I |
3 Auxiliary Output to Stop Timing on User Code Entry |
OFF |
I_OFF_I |
4 Auxiliary Output to Activate Only Between Closing and Opening Time |
OFF |
I_OFF_I |
5 Auxiliary Output to Activate only between Opening and Closing Time |
OFF |
I_OFF_I |
6 Invert Auxiliary Output (0 Volts going to 12 Volts) |
OFF |
I_OFF_I |
7 Reserved |
OFF |
I_OFF_I |
8 Reserved
|
|
Aux Output 2 Special Timing Segment 2 |
(Toggle On/Off then press * to save and exit) |
Default |
|
Option ON |
OFF |
OFF |
I_OFF_I |
1 Auxiliary Output Timed in Minutes |
Auxiliary Output Time in Seconds |
OFF |
I_OFF_I |
2 Auxiliary Output to Latch |
ON |
I_ON_I |
3 Auxiliary Output to Stop Timing on User Code Entry |
OFF |
I_OFF_I |
4 Auxiliary Output to Activate Only Between Closing and Opening Time |
OFF |
I_OFF_I |
5 Auxiliary Output to Activate only between Opening and Closing Time |
OFF |
I_OFF_I |
6 Invert Auxiliary Output (0 Volts going to 12 Volts) |
OFF |
I_OFF_I |
7 Reserved |
OFF |
I_OFF_I |
8 Reserved
|
47# |
Auxiliary Output 1 Event & Time |
(Enter 1 to 2 digits then * for next, # Exits) |
Default |
0 |
I_ _I |
Event Number for Output 1 |
(Enter Event Number) |
10 |
I_ _I |
Timing for Output 1 |
(1 to 255 Minutes/Seconds (See option 46)) |
|
|
|
(0 = Output Follows Event)
|
48# |
Auxiliary Output 2 Event & Time |
(Enter 1 to 2 digits then * for next, # Exits) |
Default |
0 |
I_ _I |
Event Number for Output 1 |
(Enter Event Number) |
10 |
I_ _I |
Timing for Output 1 |
(1 to 255 Minutes/Seconds (See option 46)) |
|
|
|
(0 = Output Follows Event)
|
51# |
Autotest Control |
(Enter 1 to 2 digits then * for next, # Exits) |
Default |
0 |
I_ _I |
Autotest Interval select |
(0 = Autotest in Days, 1 = Autotest in Hours) |
24 |
I_ _I |
Autotest Interval |
(1 to 255 Days or 1 to 23 Hours) |
2 |
I_ _I |
Autotest Time (Hours) |
(1 to 23 O’Clock) |
0 |
I_ _I |
Autotest Time (Mins after the Hour) |
(0 to 59 minutes)
|
52# |
Opening Time |
(Enter 1 to 2 digits then * for next, # Exits) |
Default |
8 |
I_ _I |
Hour of Opening Time |
(0 to 24) |
0 |
I_ _I |
Minutes of the Hour of Opening Time |
(0 to 59)
|
53# |
Closing Time / Auto Arming Time |
(Enter 1 to 2 digits then * for next, # Exits) |
Default |
20 |
I_ _I |
Hour of Opening Time |
(0 to 24) |
0 |
I_ _I |
Mins of the Hour of Opening Time |
(0 to 59)
|
54# |
Days of the Week System is Open |
(Toggle On/Off then press * to save # to Exit) |
Default |
ON |
I_ _I |
1 Open on Sunday |
Auxiliary Output Time in Seconds |
ON |
I_ _I |
2 Open on Monday |
ON |
I_ _I |
3 Open on Tuesday |
ON |
I_ _I |
4 Open on Wednesday |
ON |
I_ _I |
5 Open on Thursday |
ON |
I_ _I |
6 Open on Friday |
ON |
I_ _I |
7 Open on Saturday |
ON |
I_ _I |
8 Reserved
|
55# |
Days of the Week for Auto Arming |
(Toggle On/Off then press * to save and exit) |
Default |
OFF |
I_ _I |
1 Auto Arming on Sunday |
Auxiliary Output Time in Seconds |
OFF |
I_ _I |
2 Auto Arming on Monday |
OFF |
I_ _I |
3 Auto Arming on Tuesday |
OFF |
I_ _I |
4 Auto Arming on Wednesday |
OFF |
I_ _I |
5 Auto Arming on Thursday |
OFF |
I_ _I |
6 Auto Arming on Friday |
OFF |
I_ _I |
7 Auto Arming on Saturday |
OFF |
I_ _I |
8 Reserved |
|
4/2 Format Report Codes (Leave alone) |
(Enter 1 to 4 digits then * to save and exit) |
56# |
Restore Communication Code |
I_0_I |
57# |
Bypass Communication Code |
I_0_I |
58# |
Tamper Communication Code |
I_0_I |
59# |
Trouble Communication Code |
I_0_I |
60# |
Sensor Low Battery Communication Code |
I_0_I |
61# |
Sensor Missing Communication Code |
I_0_I |
62# |
Duress Communication Code |
I_0_I_0_I |
63# |
Auxiliary 1 Communication Code |
I_0_I_0_I |
64# |
Auxiliary 2 Communication Code |
I_0_I_0_I |
65# |
Keypad Panic Communication Code |
I_0_I_0_I |
66# |
Keypad Multiple Code Entry Tamper |
I_0_I_0_I |
67# |
Box Tamper / Box Tamper Restore |
I_0_I_0_II_0_I_0_I |
68# |
AC Fail / AC Restore |
I_0_I_0_II_0_I_0_I |
69# |
Low Battery / Low Battery Restore |
I_0_I_0_II_0_I_0_I |
70# |
AUX Power Short / Power Short Restore |
I_0_I_0_II_0_I_0_I |
71# |
Bell Tamper / Bell Tamper Restore |
I_0_I_0_II_0_I_0_I |
74# |
Expander Trouble / Expander Trouble Restore |
I_0_I_0_II_0_I_0_I |
75# |
Failure to Communicate |
I_0_I_0_I |
76# |
Log Full Communication Code |
I_0_I_0_I |
77# |
Opening Communication Code |
I_0_I |
78# |
Closing Communication Code |
I_0_I |
79# |
Autotest Communication Code |
I_0_I_0_I |
80# |
Recent Closing and Exit Alarm |
I_0_I_0_I |
81# |
Start Programming / End Programming |
I_0_I_0_II_0_I_0_I |
82# |
End Download |
I_*_I_*_II_0_I_0_I |
83# |
Cancel Communication Code |
I_0_I |
|