Caddx 9000 / 9000E Program

****CADDX 8950 OR 9075 PROGRAMMER IS REQUIRED IF INSTALLER Code HAS BEEN CHANGED****
Download Info Have tech press * 99 # while phone is ringing
Enter Program Programmer Plug into program terminal on panel
LED Keypad Programming enter 9713 (default)
LCD Keypad Press C 0 0, press 2 to select Panel Programming
Exit Program Keypad Press 930#
Programmer Unplug from main board
(It is NOT required to save data before exiting like older Caddx panels)
Reset to Default 910 #
Move to Location Location + #
Entering Data Enter data + * + # to save and move to next location
Example: Master Code in 000 to 003 is entered as 1* # 2 * # 3* # 4* #
Exiting Program
If using Programmer unhook programmer from panel
If keypad programming press 930 #
Hex Programming A = 10, B = 11, C = 12, D = 13, E = 14, F = 15

Location Description Value
000-003 User 1 Master Code I_1_I_2_I_3_I_4_I
004-007 User 2 Arm/Dis Code I_F_I_F_I_F_I_F_I (Disabled)
008-011 User 3 Arm/Dis Code I_F_I_F_I_F_I_F_I (Disabled)
012-105 User 4 Arm/Dis Code I_F_I_F_I_F_I_F_I (Disabled)
016-019 User 5 Arm/Dis Code I_F_I_F_I_F_I_F_I (Disabled)
020-023 User 6 Arm/Dis Code I_F_I_F_I_F_I_F_I (Disabled)
024-027 User 7 Arm/Dis Code I_F_I_F_I_F_I_F_I (Disabled)
028-031 User 8 Arm/Dis Code I_F_I_F_I_F_I_F_I (Disabled)
032-035 User 9 Arm/Dis Code I_F_I_F_I_F_I_F_I (Disabled)
036-039 User 10 Arm/Dis Code I_F_I_F_I_F_I_F_I (Disabled)
040-043 User 11 Arm/Dis Code I_F_I_F_I_F_I_F_I (Disabled)
044-047 User 12 Arm/Dis Code I_F_I_F_I_F_I_F_I (Disabled)
048-051 User 13 Arm/Dis Code I_F_I_F_I_F_I_F_I (Disabled)
052-055 User 14 Arm/Dis Code I_F_I_F_I_F_I_F_I (Disabled)
056-059 Hostage Code I_2_I_5_I_8_I_0_I
060-063 Installer Code I_9_I_7_I_1_I_3_I
064 Part For User 1 Arm/Dis Code I_1_I_5_I (1 = Partition 1)
(2 = Partition 2)
(4 = Partition 4)
(8 = Partition 8)
(15 = All Partitions)
065 Parts For User 2 Arm/Dis Code I_1_I_5_I
066 Parts For User 3 Arm/Dis Code I_1_I_5_I
067 Parts For User 4 Arm/Dis Code I_1_I_5_I
068 Parts For User 5 Arm/Dis Code I_1_I_5_I
069 Parts For User 6 Arm/Dis Code I_1_I_5_I
070 Parts For User 7 Arm/Dis Code I_1_I_5_I
071 Parts For User 8 Arm/Dis Code I_1_I_5_I
072 Parts For User 9 Arm/Dis Code I_1_I_5_I
073 Parts For User 10 Arm/Dis Code I_1_I_5_I
074 Parts For User 11 Arm/Dis Code I_1_I_5_I
075 Parts For User 12 Arm/Dis Code I_1_I_5_I
076 Parts For User 13 Arm/Dis Code I_1_I_5_I
077 Parts For User 14 Arm/Dis Code I_1_I_5_I
078 Parts For User 15 Arm/Dis Code I_1_I_5_I
079 Parts “Go to Program” Code I_1_I_5_I
080-087 Prime Phone Number Digits 1-8 I_F_I_1 I_8_I_?_I_?_I_?_I_?_I_?_I
088-095 Prime Phone Number Digits 9-16 I_?_I_?_I_?_I_?_I_E_I_0_I_0_I_0_I
11 (B) = * (don’t use 10’s for 0’s)
12 (C) = #
13 (D) = 4 second pause
14 (E) = End phone number
15 (F) = Touch Tone
096-100 Primary Account Number I_?_I_?_I_?_I_?_I (Use 10 for 0 in Account)
101 Primary Format I_E_I (E = 14 (SIA))
0 = Communicator (Disabled)
1 = Ademco Contact ID (DTMF)
2 = Ademco 4/2 Express (DTMF)
3 = FBII Superfast (DTMF 2300Hz)
4 = Ademco High Speed (DTMF)
5 = Extended Radionics Slow 1800 Transmit, 2300 Handshake 20PPS
6 = Caddx Modem (Proprietary)
7 = Extended Radionics Fast 1800 Transmit, 2300 HAndshake 40PPS
8 = Extended Radionics Fast 1800 Transmit 1400 Handshake 40PPS
9 = Extended Radionics Fast w/Parity 1800 Transmit, 2300 Handshake 40PPS Extended
A (10) = Scantronics (DTMF 2300 Handshake)
B (11) Silent Knight 4/2 Slow 1900 Transmit, 1400 Handshake 10PPS
C (12) Silent Knight 4/2 Fast 1900 Transmit, 1400 Handshake 20PPS
D (13) Sescoa/Franklin Fast 1800 Transmit, 2300 Handshake 20PPS
E (14) SIA (FSK)
F (15) Over-Ride Enable (See locations 610 to 615)
102-110 Secondary Phone # Digits 1-8 I_X_I_X_I_X_I_X_I_X_I_X_I_X_I_X_I
111-117 Secondary Phone # Digits 9-16 I_X_I_X_I_X_I_X_I_X_I_X_I_X_I_X_I
118-122 Secondary Account Number I_X_I_X_I_X_I_X_I (Disabled)
123 Secondary Format I_X_I (Disabled)
124-127 Partition 3 Account Code I_X_I_X_I_X_I_X_I (Disabled)
128-131 Partition 4 Account Code I_X_I_X_I_X_I_X_I (Disabled)
132 Phone Sequence Controller I_D_I
1 = Alternate between Phone 1 and 2 with 2 calls each
2 = All attempts to Phone 1, if unsuccessful delay 5 minutes then call Phone 2
4 = Forces communicator to tie Account number to Phone number
8 = All attempts to Phone 1, if unsuccessful call Phone 2 with no 5 minute delay
0 = Account number corresponds to the Partition
133 Number of Dial Attempts I_8_I (8 Attempts)
134 Primary Entry Delay Time I_3_I (30 Seconds)
135 Primary Exit Delay I_6_I (60 Seconds)
136 Secondary Entry Delay I_3_I (30 Seconds)
137 Secondary Exit Delay I_6_I (60 Seconds)
138 Siren Cut-off Time I_4_I (8 Minutes)
139 Zone 1 Type I_?_I
140 Zone 2 Type I_?_I 1 = Day Zone
2 = 24 Hour Zone
3 = Entry/Exit
4 = interior Delay
5 = Interior Follower
6 = Instant/Perimeter
7 = Secondary Delay
8 = Priority/Smoke Det
9 = Keyswitch
141 Zone 3 Type I_?_I
142 Zone 4 Type I_?_I
143 Zone 5 Type I_?_I
144 Zone 6 Type I_?_I
145 Zone 7 Type I_?_I
146 Zone 8 Type I_?_I
147 Zone 9 Type I_?_I
148 Zone 10 Type I_?_I
149 Zone 11 Type I_?_I
150 Zone 12 Type I_?_I
151 Zone 13 Type I_?_I
152 Zone 14 Type I_?_I
153 Zone 15 Type I_?_I
154 Zone 16 Type I_?_I
155 Zone 1 Special Characteristics I_12_I (1 = Fast Loop 200ms)
(2 = Group Bypass)
(4 = Entry Guard Zone)
(8 = Zone Bypass Enable)
(Add together if needed)
156 Zone 2 Special Characteristics I_12_I
157 Zone 3 Special Characteristics I_12_I
158 Zone 4 Special Characteristics I_12_I
159 Zone 5 Special Characteristics I_12_I
160 Zone 6 Special Characteristics I_12_I
161 Zone 7 Special Characteristics I_12_I
162 Zone 8 Special Characteristics I_12_I
163 Zone 9 Special Characteristics I_12_I
164 Zone 10 Special Characteristics I_12_I
165 Zone 11 Special Characteristics I_12_I
166 Zone 12 Special Characteristics I_12_I
167 Zone 13 Special Characteristics I_12_I
168 Zone 14 Special Characteristics I_12_I
169 Zone 15 Special Characteristics I_12_I
170 Zone 16 Special Characteristics I_12_I
171 zone 1 Audible Characteristics I_13_I (1 = Yelp Siren)
(2 = Steady Siren)
(4 = Keypad Sounder)
(8 = Chime Enabled)
(Add together if needed)

(Use 5 for Motions)

172 zone 2 Audible Characteristics I_13_I
173 zone 3 Audible Characteristics I_13_I
174 zone 4 Audible Characteristics I_13_I
175 zone 5 Audible Characteristics I_13_I
176 zone 6 Audible Characteristics I_13_I
177 zone 7 Audible Characteristics I_13_I
178 zone 8 Audible Characteristics I_13_I
179 zone 9 Audible Characteristics I_13_I
180 zone 10 Audible Characteristics I_13_I
181 zone 11 Audible Characteristics I_13_I
182 zone 12 Audible Characteristics I_13_I
183 zone 13 Audible Characteristics I_13_I
184 zone 14 Audible Characteristics I_13_I
185 zone 15 Audible Characteristics I_13_I
186 zone 16 Audible Characteristics I_13_I
187 zone 1 Reporting Characteristics I_11_I (1 Reports Restores)
(2 Reports Bypasses)
(4 Reports Troubles)
(8 Reports Cancels)
(Add together if needed)
188 zone 2 Reporting Characteristics I_11_I
189 zone 3 Reporting Characteristics I_11_I
190 zone 4 Reporting Characteristics I_11_I
191 zone 5 Reporting Characteristics I_11_I
192 zone 6 Reporting Characteristics I_11_I
193 zone 7 Reporting Characteristics I_11_I
194 zone 8 Reporting Characteristics I_11_I
195 zone 9 Reporting Characteristics I_11_I
196 zone 10 Reporting Characteristics I_11_I
197 zone 11 Reporting Characteristics I_11_I
198 zone 12 Reporting Characteristics I_11_I
199 zone 13 Reporting Characteristics I_11_I
200 zone 14 Reporting Characteristics I_11_I
201 zone 15 Reporting Characteristics I_11_I
202 zone 16 Reporting Characteristics I_11_I
203 Communicator Abort I_0_I (Disabled)
204 Immediate Restore by Zone I_0_I (Disabled)
205 Force Arm Enable I_0_I (Disabled)
206 Silent Holdup/Panic I_0_I (1=Silent 0=Audible)
207 Priority (Fire) Siren Cutoff Inhibit I_0_I (Disabled)
208 Bypassed Zone Keypad Sounder I_0_I (Disabled)
209 AC Power Out Keypad Sounder I_1_I (Enabled)
210 Siren/Bell Test Feature I_0_I (1=Enable Bell Test)
211 Entry-Guard Security Feature I_0_I (Disabled)
212 Ringback Feature I_0_I (Disabled)
213 Multi Part: 1st Open/Last Close I_0_I (Disabled)
214 Resettable Aux Power I_1_I (# Key=Fire Reset)
215 Siren Output Limit I_0_I (Disabled)
216 Communicator Report Limit I_0_I (Disabled)
217 Partition Siren Inhibit I_0_I (Disabled)
218 50 HZ Power Source I_0_I (Disabled)
219 Swinger Shutdown Feature I_3_I (3 trips)
220 Auto Bypass/Instant Arming I_0_I (Disabled)
(3=Pir Home/Away)
221 Delay of Line Seizure for Abort I_0_I (Disabled)
221 Quick Arm Digit I_0_I (1 to 9 will Arm)
223 Entry-Guard Delay Time I_2_I (20 Seconds)
224-227 Pin 1 I_0_I_0_I_C_I_A_I
228-231 Pin 2 I_0_I_0_I_C_I_B_I
232-235 Pin 3 I_0_I_F_I_C_I_2_I
236-239 Pin 4 I_0_I_0_I_C_I_2_I
240 Inverting the Auxiliary Outputs I_0_I (Disabled)
241 Timing for Aux Outputs I_0_I (Disabled)
242 Answering Machine Over-Ride I_1_I (Enable Ring/Hang/Ring)
243 Rings to Answer Download( x2) I_4_I (8 Rings)
244 Assign Chime Code I_1_I
245 Assigning the Entry-Guard Code I_0_I
246 Common Area I_0_I
247 Zones in Partition 1 I_0_I (Not Partitioned)
248 Zones in Partition 2 I_0_I (Not Partitioned)
249 Zones in Partition 3 I_0_I (Not Partitioned)
250 Power Up Condition I_0_I (1=Power up Disarmed)
251 Power Up Delay I_0_I (x10 Seconds)
252 Telephone Line Monitor I_0_I 0 = Disabled
1 = Activates Siren
2 = Keypad Sounder only
4 or 8 = Dial Tone Detect or Attempts
253 TLM (Attempts) Counter I_4_I (4 Attempts)
254 Dynamic Battery Test Time I_0_I
255 Dynamic Batter Test Duration I_3_I
256-259 Zone 1 Communicator Code I_3_I_0_I_1_I_13_I (1st 3 Digits=Report Code)
(Last Digit=Call Direction)
1=to Phone 1
2=to Phone 2
4=to Event Buffer
8=Listen In (9000E)

These are set for SIA
1st digit of Report Code
must be set by zone type
from below list
1 = Smoke Detector
2 = Audible Panic
3 = Burg Zone
4 = Gas Alarm
5 = Heat Detector
6 = Water Alarm
7 = Emergency Alarm
8 = Sprinkler Alarm
10 = Silent Holdup
11 = Medical Alarm
12 = Freeze Alarm

260-263 Zone 2 Communicator Code I_3_I_0_I_2_I_13_I
264-267 Zone 3 Communicator Code I_3_I_0_I_3_I_13_I
268-271 Zone 4 Communicator Code I_3_I_0_I_4_I_13_I
272-275 Zone 5 Communicator Code I_3_I_0_I_5_I_13_I
276-279 Zone 6 Communicator Code I_3_I_0_I_6_I_13_I
280-283 Zone 7 Communicator Code I_3_I_0_I_7_I_13_I
284-287 Zone 8 Communicator Code I_3_I_0_I_8_I_13_I
288-291 Zone 9 Communicator Code I_3_I_0_I_9_I_13_I
292-295 Zone 10 Communicator Code I_3_I_1_I_0_I_13_I
296-299 Zone 11 Communicator Code I_3_I_1_I_1_I_13_I
300-303 Zone 12 Communicator Code I_3_I_1_I_2_I_13_I
304-307 Zone 13 Communicator Code I_3_I_1_I_3_I_13_I
308-311 Zone 14 Communicator Code I_3_I_1_I_4_I_13_I
312-315 Zone 15 Communicator Code I_3_I_1_I_5_I_13_I
316-319 Zone 16 Communicator Code I_3_I_1_I_6_I_13_I
320-323 Duress Communicator I_A_I_0_I_0_I_13_I (Set for SIA Reporting)
324-327 Keypad [1] & [3] Fire Report Code I_1_I_0_I_0_I_13_I (Set for SIA Reporting)
328-331 Keypad [4] & [6] Med Report I_B_I_0_I_0_I_13_I (Set for SIA Reporting)
332-335 Keypad Panic Report Code I_2_I_0_I_0_I_13_I (Set for SIA Reporting)
336-339 Keypad Tamper Report Code I_0_I_0_I_0_I_0_I (Disabled)
340-343 Auto Test Report Code I_0_I_0_I_0_I_0_I (Disabled)
344-347 Checksum Report Code I_0_I_0_I_0_I_0_I (Disabled)
348 Opening Reports For Users 1-15 I_0_I (Disabled, 1 if needed)
349 Opening Report to Phone #1 & #2 I_4_I (4 = Openings go to Internal Log,)
(5 = Open Reports go to Monitoring Station)
350 Closing Reports For Users 1-15 I_0_I (Disabled, 1 if needed)
351 Closing Report to Phone #1, #2 I_4_I (4 = Closings go to internal Log,)
(5 = Closing Reports go to Monitoring Station)
352 Closing Reports For Users 16-30 I_0_I (Disabled, 1 if needed)
353 Opening Reports For Users 16-30 I_0_I (Disabled, 1 if needed)
354 Cancel Report Code Users 1-15 I_1_I (1 Enables, 0 disables)
355 Cancel Report Codes Users 16-30 I_1_I (1 Enables, 0 disables)
356-359 AC Power Loss Report Code I_1_I_0_I_0_I_5_I (0005 disables)
360-363 Low Battery Report I_1_I_0_I_0_I_5_I (0005 disables)
364 Restore Code for Zones 1-8 I_0_I (Disabled, if needed use 1)
365 Restore Code for Zones 9-16 I_0_I (Disabled, if needed use 1)
366 Restore Code for Zones 17-24 I_0_I (Disabled, if needed use 1)
367 Restore Code for Zones 25-32 I_0_I (Disabled, if needed use 1)
368 Zone Bypass Code for Zones 1-8 I_0_I (Disabled)
369 Zone Bypass Code for Zones 9-16 I_0_I (Disabled)
370 Zone Bypass Code for Zones 17-24 I_0_I (Disabled)
371 Zone Bypass Code for Zones 25-32 I_0_I (Disabled)
372 Zone Trouble Code for Zones 1-8 I_0_I (Disabled, if needed use 1)
373 Zone Trouble Code for Zones 9-16 I_0_I (Disabled, 1 if needed)
374 Zone Trouble Code for Zones 17-24 I_0_I (Disabled, 1 if needed)
375 Zone Trouble Code for Zones 25-32 I_0_I (Disabled, 1 if needed)
376 AC Power/Low Batt Restore Code I_0_I (Disabled, 1 if needed)
377 Number of Expansion Modules I_0_I (Disabled)
378 Exp Module Trbl Report I_0_I (Disabled, 1 if needed)
379 Exp Module Trbl Report Phone I_0_I (Disabled, 1 if needed)
380 Zone 17 Zone Type I_?_I
381 Zone 18 Zone Type I_?_I 1 = Day Zone
2 = 24 Hour Zone
3 = Entry/Exit
4 = interior Delay
5 = Interior Follower
6 = Instant/Perimeter
7 = Secondary Delay
8 = Priority Zone
9 = Keyswitch
382 Zone 19 Zone Type I_?_I
383 Zone 20 Zone Type I_?_I
384 Zone 21 Zone Type I_?_I
385 Zone 22 Zone Type I_?_I
386 Zone 23 Zone Type I_?_I
387 Zone 23 Zone Type I_?_I
388 Zone 25 Zone Type I_?_I
389 Zone 26 Zone Type I_?_I
390 Zone 27 Zone Type I_?_I
391 Zone 28 Zone Type I_?_I
392 Zone 29 Zone Type I_?_I
393 Zone 30 Zone Type I_?_I
394 Zone 31 Zone Type I_?_I
395 Zone 32 Zone Type I_?_I
396 Zone 17 Special Characteristics I_12_I (1 = Fast Loop 200ms)
(2 = Group Bypass)
(4 = Entry Guard Zone)
(8 = Zone Bypass Enable)
397 Zone 18 Special Characteristics I_12_I
398 Zone 19 Special Characteristics I_12_I
399 Zone 20 Special Characteristics I_12_I
400 Zone 21 Special Characteristics I_12_I
401 Zone 22 Special Characteristics I_12_I
402 Zone 23 Special Characteristics I_12_I
403 Zone 24 Special Characteristics I_12_I
404 Zone 25 Special Characteristics I_12_I
405 Zone 26 Special Characteristics I_12_I
406 Zone 27 Special Characteristics I_12_I
407 Zone 28 Special Characteristics I_12_I
408 Zone 29 Special Characteristics I_12_I
409 Zone 30 Special Characteristics I_12_I
410 Zone 31 Special Characteristics I_12_I
411 Zone 32 Special Characteristics I_12_I
412 Zone 17 Audible Characteristics I_13_I
413 Zone 18 Audible Characteristics I_13_I (1 = Yelp Siren)
(2 = Steady Siren)
(4 = Keypad Sounder)
(8 = Chime Enabled)
(Add together if needed)
414 zone 19 Audible Characteristics I_13_I
415 zone 20 Audible Characteristics I_13_I
416 zone 21 Audible Characteristics I_13_I
417 zone 22 Audible Characteristics I_13_I
418 zone 23 Audible Characteristics I_13_I
419 zone 24 Audible Characteristics I_13_I
420 zone 25 Audible Characteristics I_13_I
421 zone 26 Audible Characteristics I_13_I
422 zone 27 Audible Characteristics I_13_I
423 zone 28 Audible Characteristics I_13_I
424 zone 29 Audible Characteristics I_13_I
425 zone 30 Audible Characteristics I_13_I
426 zone 31 Audible Characteristics I_13_I
427 zone 32 Audible Characteristics I_13_I
428 zone 17 Reporting Characteristics I_11_I (1 Reports Restores)
(2 Reports Bypasses)
(4 Reports Troubles)
(8 Reports Cancels)
(Add together if needed)
429 zone 18 Reporting Characteristics I_11_I
430 zone 19 Reporting Characteristics I_11_I
431 zone 20 Reporting Characteristics I_11_I
432 zone 21 Reporting Characteristics I_11_I
433 zone 22 Reporting Characteristics I_11_I
434 zone 23 Reporting Characteristics I_11_I
435 zone 24 Reporting Characteristics I_11_I
436 zone 25 Reporting Characteristics I_11_I
437 zone 26 Reporting Characteristics I_11_I
438 zone 27 Reporting Characteristics I_11_I
439 zone 28 Reporting Characteristics I_11_I
440 zone 29 Reporting Characteristics I_11_I
441 zone 30 Reporting Characteristics I_11_I
442 zone 31 Reporting Characteristics I_11_I
443 zone 32 Reporting Characteristics I_11_I
444-447 zone 17 Communicator Code I_3_I_1_I_7_I_13_I (1st 3 Digits=Report Code)
(4th Digit=Call Direction)
1=to Phone 1
2=to Phone 2
4=to Event Buffer
8=Listen In (9000E)

(These are set for SIA)
(Do not change or they)
(will not send correctly)

(1005 If Smoke on zone)

448-451 zone 18 Communicator Code I_3_I_1_I_8_I_13_I
452-455 zone 19 Communicator Code I_3_I_1_I_9_I_13_I
456-459 zone 20 Communicator Code I_3_I_2_I_0_I_13_I
460-463 zone 21 Communicator Code I_3_I_2_I_1_I_13_I
464-467 zone 22 Communicator Code I_3_I_2_I_2_I_13_I
468-471 zone 23 Communicator Code I_3_I_2_I_3_I_13_I
472-475 zone 24 Communicator Code I_3_I_2_I_4_I_13_I
476-479 zone 25 Communicator Code I_3_I_2_I_5_I_13_I
480-483 zone 26 Communicator Code I_3_I_2_I_6_I_13_I
484-487 zone 27 Communicator Code I_3_I_2_I_7_I_13_I
488-491 zone 28 Communicator Code I_3_I_2_I_8_I_13_I
492-495 zone 29 Communicator Code I_3_I_2_I_9_I_13_I
496-499 zone 30 Communicator Code I_3_I_1_I_7_I_13_I
500-503 zone 31 Communicator Code I_3_I_1_I_7_I_13_I
504-507 zone 32 Communicator Code I_3_I_1_I_7_I_13_I
508-509 Reserved
510 European Pulse Dial I_0_I (Disabled)
511 Expander Trouble Restore Code I_0_I (Disabled)
512-515 user 16 Arm/Disarm Code I_F_I_F_I_F_I_F_I (Disabled)
516-519 user 17 Arm/Disarm Code I_F_I_F_I_F_I_F_I (Disabled)
520-523 user 18 Arm/Disarm Code I_F_I_F_I_F_I_F_I (Disabled)
524-527 user 19 Arm/Disarm Code I_F_I_F_I_F_I_F_I (Disabled)
528-531 user 20 Arm/Disarm Code I_F_I_F_I_F_I_F_I (Disabled)
532-535 user 21 Arm/Disarm Code I_F_I_F_I_F_I_F_I (Disabled)
536-539 user 22 Arm/Disarm Code I_F_I_F_I_F_I_F_I (Disabled)
540-543 user 23 Arm/Disarm Code I_F_I_F_I_F_I_F_I (Disabled)
544-547 user 24 Arm/Disarm Code I_F_I_F_I_F_I_F_I (Disabled)
548-551 user 25 Arm/Disarm Code I_F_I_F_I_F_I_F_I (Disabled)
552-555 user 26 Arm/Disarm Code I_F_I_F_I_F_I_F_I (Disabled)
556-559 user 27 Arm/Disarm Code I_F_I_F_I_F_I_F_I (Disabled)
560-563 user 28 Arm/Disarm Code I_F_I_F_I_F_I_F_I (Disabled)
564-567 user 29 Arm/Disarm Code I_F_I_F_I_F_I_F_I (Disabled)
568-571 user 30 Arm/Disarm Code I_F_I_F_I_F_I_F_I (Disabled)
572 Part For User 16 Arm/Disarm Code I_15_I (1 = Part 1)
(2 = Part 2)
(4 = Part 4)
(8 = Part 8)
573 Part For User 17 Arm/Disarm Code I_15_I
574 Part For User 18 Arm/Disarm Code I_15_I
575 Part For User 19 Arm/Disarm Code I_15_I
576 Part For User 20 Arm/Disarm Code I_15_I
577 Part For User 21 Arm/Disarm Code I_15_I
578 Part For User 22 Arm/Disarm Code I_15_I
579 Part For User 23 Arm/Disarm Code I_15_I
580 Part For User 24 Arm/Disarm Code I_15_I
581 Part For User 25 Arm/Disarm Code I_15_I
582 Part For User 26 Arm/Disarm Code I_15_I
583 Part For User 27 Arm/Disarm Code I_15_I
584 Part For User 28 Arm/Disarm Code I_15_I
585 Part For User 29 Arm/Disarm Code I_15_I
586 Part For User 30 Arm/Disarm Code I_15_I
587 Early Open, Late Close/Auto Arm I_0_I (Disabled)
588-591 Comm Code for Late Closing I_0_I_0_I_0_I_1_I
592-595 Comm Code for Early Opening I_0_I_0_I_0_I_1_I
596-599 Download Complete Report Code I_0_I_0_I_0_I_1_I
600-603 Opening Time I_0_I_0_I_0_I_1_I
604-607 Closing Time I_0_I_0_I_0_I_1_I
608 Closed Saturday I_0_I
609 Closed Sunday I_0_I
610 Format Over-Ride I_0_I
611 Format Over-Ride I_0_I
612 Format Over-Ride I_0_I 1 = 1800Hz Pulse Transmit
2 = 2300Hz Handshake
4 = Single Round Checksum
8 = 2-Digit Event Code
613 Format Over-Ride I_0_I 1 = Extended Reporting
2 = Hex Digits
4 = 20PPS
8 = 10PPS
614 Format Over-Ride I_0_I 1 = Pager format
2 = Ademco Handshake
4 = Reserved
5 = FBII Superfast
615 Format Over-Ride I_0_I 1 = Contact ID/Ademco Hi
2 = Reserved
4 = 4/3 and Contact ID
8 = DTMF
616 Hour for Autotest – Tens Digit I_0_I
617 Hour for Autotest – Ones Digit I_0_I
618 Minute for Autotest – Ones Digit I_0_I
619 Minute for Autotest – Tens Digit I_0_I
620-621 Autotest Intervals I_2_I_8_I
622 Auto Initiated Download C(All) I_0_I
623 AC Power Loss Delay (x1 minute) I_F_I (15 Minute Delay)
624 Days Since Last Autotest Tens Digit I_0_I
625 Days Since Last Autotest Ones Digit I_0_I
626 Current Day of the Week I_?_I
627 Current Month I_?_I
628 Current Day of Month – Tens Digit I_?_I
629 Current Day of Month – Ones Digit I_?_I
630 Current Year – Tens Digit I_?_I
631 Current Year – Ones Digit I_?_I
632 Current Hour – Tens Digit I_?_I
633 Current Hour – Ones Digit I_?_I
634 Current Minute – Tens Digit I_?_I
635 Current Minute – Ones Digit I_?_I
Exiting Programming If using Programmer unhook programmer from panel (no need to save)
If keypad programming press 930 #
The Following Locations are Accessible only through Downloading
636-643 Control Panel Access Code I_9_I_0_I_0_I_0_I_0_I_0_I_0_I_0_I
644-651 Callback Phone # Digits 1-8 I_0_I (Disabled)
652-659 Callback Phone # Digits 9-16 I_0_I (Disabled)
660 Callback Enable I_0_I (Disabled)
1 = Panel will Automatically Callback for Download
2 = Site initiated Download by *98#
4 = Panel automatically calls download computer when Event Buffer is full
661 Local Programming Lockout I_0_I (Disabled)
0 = Keypad Programming Enabled
5 = No Local Programming
A = Communication Locked Out
662 Control Panel Shutdown I_0_I (Disabled)
0 = Panel Operation Normal
A = Panel Operation Disabled/Shutdown