* Caddx 8950 Programmer is required if Installer Code has been Changed *
Download Info Have tech press * 9 # while phone is ringing
Enter Program If using Programmer plug into program terminal on panel
If keypad programming enter 9713 (default)
LCD Keypad Press C 0 0, press 2 to select Panel Programming
(If asked what panel “1=8900, 2=Aust, 3=Other” select 3 for Other)
Factory Default 210 #
Go to Location Location + #
Enter Data Enter data + * + # to save and move to next location
Example: Master Code in 0 to 3 would be entered as 1* # 2 * # 3* # 4* #
Exit Program If using 8950 Programmer save data with 220# and unplug from panel
If using keypad save with 220# and exit with 230#
Hex Program A = 10 B = 11 C = 12 D = 13 E = 14 F = 15
Zone Page 4*2 Std Click HERE for List of what below programming will report

Location Description Value
0-3 User 1 Master Code I_1_I_2_I_3_I_4_I
4-7 User 2 Arm/Disarm Code I_F_I_F_I_F_I_F_I (F (15) = Disabled)
8-11 User 3 Arm/Disarm Code I_F_I_F_I_F_I_F_I (F (15) = Disabled)
12-15 User 4 Arm/Disarm Code I_F_I_F_I_F_I_F_I (F (15) = Disabled)
16-19 User 5 Arm/Disarm Code I_F_I_F_I_F_I_F_I (F (15) = Disabled)
20-23 User 6 Arm/Disarm Code I_F_I_F_I_F_I_F_I (F (15) = Disabled)
24-27 User 7 Hostage Code I_2_I_5_I_8_I_0_I (F (15) = Disabled)
28-31 User 8 Installer Code I_9_I_7_I_1_I_3_I (Default)
32-39 Primary Phone Number Digits 1-8 I_F_I_1_I_8_I_?_I_?_I_?_I_?_I_?_I
40-47 Primary Phone Number Digits 9-16 I_?_I_?_I_?_I_?_I_0_I_0_I_0_I_0_I
A (10) if any 0’s in number or to end number
F (15) = Touch Tone Dial
D (13) = 4 second pause
48-51 Primary Account Number I_?_I_?_I_?_I_?_I (Use 10 for 0 in Account)
52 Primary Format I_5_I
0 = Communicator (Disabled)
1 = 3/1 or 4/1 Ademco/Silent Knight Slow 1900 Transmit, 1400 Handshake 10 PPS
2 = 3/1 or 4/1 Ademco/Silent Knight Slow 1900 Transmit, 1400 Handshake 20 PPS
3 = 3/1 or 4/1 Sescoa/Franklin Slow 1800 Transmit, 2300 Handshake 10 PPS
4 = 3/1 or 4/1 Sescoa/Franklin Fast 1800 Transmit, 2300 Handshake 20 PPS
5 = 4/2 Extended Radionics Slow 1800 Transmit, 2300 Handshake 20PPS
6 = 4/2 Extended Radionics Slow 1800 Transmit, 1400 Handshake 20PPS
7 = 4/2 Extended Radionics Fast 1800 Trasmit, 2300 Handshake 40PPS
8 = 4/2 Extended Radionics Fast 1800 Transmit 1400 Handshake 40PPS
9 = 4/2 Extended Radionics Fast with Parity 1800 Transmit, 2300 Handshake 40PPS
A (10) 4/2 Extended Radionics Fast with Parity 1800 Transmit, 1400 Handshake 40PPS
B (11) 4/2 Silent Knight 4/2 Slow 1900 Transmit, 1400 Handshake 10PPS
C (12) 4/2 Silent Knight 4/2 Fast 1900 Transmit, 1400 Handshake 20PPS
D (13) 3/1 or 4/1 Radionics Non-Extended 1800 Transmit, 2300 Handshake 20PPS
E (14) 3/1 or 4/1 Radionics Non-Extended 1800 Transmit, 1400 Handshake 20PPS
F (15) 3/1 or 4/1 Ademco/Silent Knight Fast Hex 1900 Transmit, 1400 Handshake 20PPS
53 Secondary Number as Backup I_1_I (0 = Secondary Backup)
(1 = Primary only used)
54-61 Secondary Number Digits 1-8 I_0_I_0_I_0_I_0_I_0_I_0_I_0_I_0_I
62-79 Secondary Number Digits 9-16 I_0_I_0_I_0_I_0_I_0_I_0_I_0_I_0_I
70-73 Secondary Account Code I_0_I (0 = Disabled)
74 Secondary Format I_0_I (0 = Disabled)
75 Entry Time 1 (x10 second) I_3_I (0 to 150 (F) seconds)
76 Exit Time 1 (x10 seconds) I_6_I (0 to 150 (F) seconds)
77 Siren Shutdown (x2 minutes) I_4_I (0 = 8 Minutes)
(1 to F (15))
78 Zone 1 Type I_?_I (1 = Day Zone)
(2 = 24 Hour (Fire/Panic Zone)
(3 = Entry/Exit)
(4 = Interior Delay)
(5 = Interior Follower)
(6 = Instant/Perimeter)
(7 = 24 Hour Silent)
(8 = Priority/Smoke Det)
(9 = Secondary Delay)
79 Zone 2 Type I_?_I
80 Zone 3 Type I_?_I
81 Zone 4 Type I_?_I
82 Zone 5 Type I_?_I
83 Zone 6 Type I_?_I
84 Zone 7 Type I_?_I
85 Zone 8 Type I_?_I
86-87 Duress Code I_2_I_2_I (Sends 22)
88-89 Fire Panic Report ( 1 & 3 ) I_3_I_2_I (Sends 23)
90-91 Med Panic Report( 4 & 6 ) I_6_I_2_I (Sends 26)
92-93 Police Panic Report(* & # ) I_1_I_2_I (Sends 21)
94-95 Tamper Report I_0_I_0_I (00 = Disabled, if needed use 5C)
(If enabled also locks keypad for 1 minute after 30 random keypresses)
96-97 “Downloading Complete” Report I_0_I_0_I (Disabled, if needed use EE)
98-99 Test Report Code I_0_I_0_I (Disabled, if needed use EE)
100-101 Reserved I_ _I_ _I (Do not Program)
102 Closing Report Code I_0_I (Disabled, if needed use 6)
103 Opening Report Code I_0_I (Disabled, if needed use 5)
104-105 Zone 1 Report Code I_1_I_3_I (Sends 31)
106-107 Zone 2 Report Code I_2_I_3_I (Sends 32)
108-109 Zone 3 Report Code I_3_I_3_I (Sends 33)
110-111 Zone 4 Report Code I_4_I_3_I (Sends 34)
112-113 Zone 5 Report Code I_5_I_3_I (Sends 35)
114-115 Zone 6 Report Code I_6_I_3_I (Sends 36)
116-117 Zone 7 Report Code I_7_I_3_I (Sends 37)
118-119 Zone 8 Report Code I_8_I_3_I (Sends 38, if smoke use 18)
120-121 AC Power Loss Report Code I_9_I_7_I (Sends 79)
122-123 Low Battery Report Code I_8_I_7_I (Sends 78)
124 Trouble Report Code (Fire) I_7_I (Sends 7 then Zone)
125 Zone Bypass Report Code I_0_I (Disabled)
126 Restore Report Code I_0_I (Disabled)
127 Cancel Report Code I_D_I (D (13) = Sends D1 D2 etc)
128 Communicator Abort
(Ends comm if Alarm Canx)
I_0_I (0 = Disabled)
(1 = Enabled)
129 Keypad Holdup/Panic Audible I_0_I (0 = Audible Panic)
(1 = No Siren Output)
(2 = No Siren or Keypad Output)
130 Number of Alarms before Swinger I_3_I (0 = Disabled)
(1 to 8 Alarms before Swinger)
131 Auto Bypass/Instant Arm I_0_I (0 = (Disabled)
(1 = Instant Doors/No Pir)
(3 = Delay Doors/No Pir)
132 Siren Driver I_1_I (0 = Internal Siren Driver)
(1 = External Siren Driver)
(If using Exterior Siren set panel jumper to VOLTAGE)
(If using internal Siren Driver set panel jumper to SIREN)
133 LED Extinguish I_0_I (0 = Disabled)
(1 = LED’s off after 60 sec)
134 Dial Attempts I_8_I (1 to 8 Attempts)
135 Power Up Condition I_0_I (0 = Last Condition)
(1 = Power Up Disarmed)
(2 = Power Up Armed)
136 Power Up Delay I_0_I (0 = No Delay on Power Up)
(1 = 60 Sec Power Up Delay)
137 Immediate Restore By Zone I_0_I (0 = Restore at Siren Timeout)
(1 = Restore immediate)
138 No Arming With a Zone Bypassed I_0_I (0 = Enabled)
(1 = No Arming if Zone Bypassed)

↓(Do not use a digit that conflicts with Installer Code!)↓
139 Quickarm Digit I_0_I (0 = Quickarm Disabled)
(1 to 9 Quickarms system)
140 Priority Siren Cutoff Inhibit I_0_I (Recycles)
141 Double Line Extended I_0_I (Disabled)
142 Siren/Bell Test I_0_I (Disabled)
143 Smoke Detector Power Reset I_1_I (0 = Disabled
(1 = Smoke Power Reset with #)
144 European Pulse Dial Ratio I_0_I (0 = Disabled)
(1 = Enabled)
145 Auxiliary Output 1 I_0_I (Armed)
146 Auxiliary Output 2 I_1_I (Ready)
147 Auxiliary Output 3 I_2_I (Burg Siren)
148 Auxiliary Output 4 I_3_I (Fire Siren)
149 Aux Output Inversion I_0_I (0 = Disabled)
(1 to F = 1 to 15 Days)
150 AC Power Loss Delay I_F_I (0 = No AC Report Delay)
(1 to F Delay x2 minutes)
151 Number of Rings to Answer Download I_8_I (0 = Downloading Disabled)
(1 to 8 Rings before answer)
152 Days Left Until Autotest Report I_0_I (0 = Autotest sends normally)
(1 to F Days until first Autotest)
153 Current Month I_?_I (0 to 12)
154 Current Year – Tens Digit I_?_I (0 to 9, if 2001 enter 0)
155 Current Year – Ones Digit I_?_I (0 to 9, if 2001 enter 1)
156 Current Day – Tens Digit I_?_I (0 to 3, if 31st enter 3)
157 Current Day – Ones Digit I_?_I (0 to 9, if 31st enter 1)
158 Current Hour – Tens Digit I_?_I (0 to 12, if 17:25 enter 1)
159 Current Hour – Ones Digit I_?_I (0 to 9, if 17:25 enter 7)
160 Current Minutes – Tens Digit I_?_I (0 to 5, if 17:25 enter 2)
161 Current Minutes – Ones Digit I_?_I (0 to 9, if 17:25 enter 5)
162 Autotest Report Hour – Tens Digit I_0_I (0 to 12, if 02:00 enter 0)
163 Autotest Report Hour – Ones Digit I_2_I (0 to 9, if 02:00 enter 2)
164 Autotest Report Mins – Tens Digit I_0_I (0 to 5, if 02:00 enter 0)
165 Autotest Report Mins – Ones Digit I_0_I (0 to 9, if 02:00 enter 0)
166 Autotest Report Interval I_0_I (0 = Disabled)
(1 to F = 1 to 15 Days)
167 Rotating Maintenance Code I_0_I ( Disabled)
168 Complex/Seed Code Digit 1 I_0_I
169 Complex/Seed Code Digit 2 I_0_I
170 Complex/Seed Code Digit 3 I_0_I
171 Complex/Seed Code Digit 4 I_0_I
172 User 7 Opening Report I_0_I (Disabled)
173 User 7 Closing Report I_0_I (Disabled)
174 Zones 3-6 EOL Resistor Defeat I_0_I (Usually leave alone)
1 = Zone 6 Normally Closed
2 = Zone 5 Normally Closed
3 = Zone 5 & 6 Normally Closed
4 = Zone 4 Normally Closed
5 = Zone 4 & 6 Normally Closed
6 = Zone 4 & 5 Normally Closed
7 = Zone 4, 5 & 6 Normally Closed
8 = Zone 3 Normally Closed
9 = Zone 3 & 6 Normally Closed
10 (A) = Zone 3 & 5 Normally Closed
11 (B) = Zone 3, 5 & 6 Normally Closed
12 (C) = Zone 3 & 4 Normally Closed
13 (D) = Zone 3, 4 & 5 Normally Closed
14 (E) = Zone 3, 4 & 5 Normally Closed
15 (F) = Zone 3, 4, 5, 6 Normally Closed
175 Zones 1, 2, 7 & 8 EOL Resistor Defeat I_0_I (Usually leave alone)
1 = Zone 2 Normally Closed
2 = Zone 1 Normally Closed
3 = Zone 2 & 1 Normally Closed
4 = Zone 7 Normally Closed
5 = Zone 7 & 2 Normally Closed
6 = Zone 7 & 1 Normally Closed
7 = Zone 7, 2 & 1 Normally Closed
8 = Zone 8 Normally Closed
9 = Zone 8 & 2 Normally Closed
10 (A) = Zone 8 & 1 Normally Closed
11 (B) = Zone 8, 2 & 1 Normally Closed
12 (C) = Zone 8 & 7 Normally Closed
13 (D) = Zone 8, 7 & 2 Normally Closed
14 (E) = Zone 8, 7 & 1 Normally Closed
15 (F) = Zone 8, 7, 2, 1 Normally Closed
176 Tamper/DL Complete/Test/Split Report I_0_I (0 = All to Phone 1)
177 AC Fail, Batt, O/C, Split Report I_0_I (0 = All to Phone 1)
178 Secondary Entry Time (X 10 secs) I_0_I (0 to 150 (F) seconds)
179 Secondary Exit Time (X 10 Secs) I_0_I (0 to 150 (F) seconds)
180 Loop Response Time I_0_I (0 = 500, 1 = 20, 5 = 100ms)
181 Reserved 0 I_0_I (Normally do not Program)
182 Reserved 6 I_0_I (Normally do not Program)
183 Reserved 11 I_0_I (Normally do not Program)
184 Reserved 0 I_0_I (Normally do not Program)
185 Reserved 10 I_0_I (Normally do not Program)
181 to 185 are format over-rides, if panel isn’t communicating correctly use 0 6 11 0 10
Exit Program If using 8950 Programmer save data with 220# and unplug from panel
If using keypad save with 220# and exit with 230#
Next locations are only programmable by downloading
186-193 Control Panel Access Code I_8_I_6_I_0_I_0_I_0_I_0_I_0_I_0_I
194-201 Callback Phone Digits 1 – 8 I_0_I_0_I_0_I_0_I_0_I_0_I_0_I_0_I
202-209 Callback Phone Digits 9 – 16 I_0_I_0_I_0_I_0_I_0_I_0_I_0_I_0_I
210 Answering Machine Defeat I_1_I (0 = Disabled)
(1 = 1 Ring/Hang/Ring)
211 Local Programming Lockout I_0_I (0 = Not Locked)
(0 = Keypad Program Enable)
(5 = No Local Programming)
(A = Communication Locked)
212 Control Panel Shutdown I_0_I (0 = System On)
(A = System Shutdown)