Caddx 8900 / 8900DL Program

* Caddx 8950 Programmer is required if Installer Code has been Changed *
Download Info Have tech press * 99 # while phone is ringing
Enter Program Move Slider Switch in Control Panel to Right “Program”
If using Programmer plug into program terminal on panel
If keypad programming enter 9713 (default)
LCD Keypad Press C 0 0, press 2 to select Panel Programming
Note: If asked what panel “1=8900, 2=Aust, 3=Other” select 1 for 8900
Reset to Defaults 210 #
Go to Location Location + #
Entering Data Enter data + * + # to save and move to next location
Example: Master Code in 0 to 3 is entered as 1* # 2 * # 3* # 4* #
Exit Program Save with 220#, move Slider Switch in Control Panel to Left “Run”
If using Programmer save with 220# and unplug from panel
If using keypad save with 220#, exit with 230#
Hex Programming A = 10, B = 11, C = 12, D = 13, E = 14, F = 15
Zone Page 4*2 Std Click HERE for List of what below programming will report

Location Description Value
0-3 User 1 Master Code I_1_I_2_I_3_I_4_I
4-7 User 2 Arm/Disarm Code I_F_I_F_I_F_I_F_I (F (15) = Disabled)
8-11 User 3 Arm/Disarm Code I_F_I_F_I_F_I_F_I (F (15) = Disabled)
12-15 User 4 Arm/Disarm Code I_F_I_F_I_F_I_F_I (F (15) = Disabled)
16-19 User 5 Arm/Disarm Code I_F_I_F_I_F_I_F_I (F (15) = Disabled)
20-23 User 6 Arm/Disarm Code I_F_I_F_I_F_I_F_I (F (15) = Disabled)
24-27 User 7 Arm/Disarm Code I_F_I_F_I_F_I_F_I (F (15) = Disabled)
28-31 User 8 Arm/Disarm Code I_F_I_F_I_F_I_F_I (F (15) = Disabled)
32-35 User 9 Arm/Disarm Code I_F_I_F_I_F_I_F_I (F (15) = Disabled)
36-39 User 10 Arm/Disarm Code I_F_I_F_I_F_I_F_I (F (15) = Disabled)
40-43 User 11 Arm/Disarm Code I_F_I_F_I_F_I_F_I (F (15) = Disabled)
44-47 User 12 Arm/Disarm Code I_F_I_F_I_F_I_F_I (F (15) = Disabled)
48-51 User 13 Arm/Disarm Code I_F_I_F_I_F_I_F_I (F (15) = Disabled)
54-55 User 14 Arm/Disarm Code I_F_I_F_I_F_I_F_I (F (15) = Disabled)
56-59 Hostage Code I_2_I_5_I_8_I_0_I
60-67 Primary Phone Number Digits 1-8 I_F_I_1_I_8_I_?_I_?_I_?_I_?_I_?_I
68-75 Primary Phone Number Digits 9-16 I_?_I_?_I_?_I_?_I_0_I_0_I_0_I_0_I
A (10) if any 0’s in number or to end number
F (15) = Touch Tone Dial
D (13) = 4 second pause
76-83 Backup Phone Number Digits 1-8 I_0_I_0_I_0_I_0_I_0_I_0_I_0_I_0_I
84-91 Backup Phone Number Digits 9-16 I_0_I_0_I_0_I_0_I_0_I_0_I_0_I_0_I
92-95 Account Number I_?_I_?_I_?_I_?_I
Use 10 for 0 in Account Number
96 Primary Format I_5_I
0 = Communicator (Disabled)
1 = 3/1 or 4/1 Ademco/Silent Knight Slow 1900 Transmit, 1400 Handshake 10 PPS
2 = 3/1 or 4/1 Ademco/Silent Knight Slow 1900 Transmit, 1400 Handshake 20 PPS
3 = 3/1 or 4/1 Sescoa/Franklin Slow 1800 Transmit, 2300 Handshake 10 PPS
4 = 3/1 or 4/1 Sescoa/Franklin Fast 1800 Transmit, 2300 Handshake 20 PPS
5 = 4/2 Extended Radionics Slow 1800 Transmit, 2300 Handshake 20PPS
6 = 4/2 Extended Radionics Slow 1800 Transmit, 1400 Handshake 20PPS
7 = 4/2 Extended Radionics Fast 1800 Trasmit, 2300 Handshake 40PPS
8 = 4/2 Extended Radionics Fast 1800 Transmit 1400 Handshake 40PPS
9 = 4/2 Extended Radionics Fast with Parity 1800 Transmit, 2300 Handshake 40PPS
A (10) 4/2 Extended Radionics Fast with Parity 1800 Transmit, 1400 Handshake 40PPS
B (11) 4/2 Silent Knight 4/2 Slow 1900 Transmit, 1400 Handshake 10PPS
C (12) 4/2 Silent Knight 4/2 Fast 1900 Transmit, 1400 Handshake 20PPS
D (13) 3/1 or 4/1 Radionics Non-Extended 1800 Transmit, 2300 Handshake 20PPS
E (14) 3/1 or 4/1 Radionics Non-Extended 1800 Transmit, 1400 Handshake 20PPS
F (15) 3/1 or 4/1 Ademco/Silent Knight Fast Hex 1900 Transmit, 1400 Handshake 20PPS
97 Entry Time 1 (X 10 Secs) I_3_I (0 to 150 (F) seconds)
98 Exit Time 1 (X 10 Secs) I_6_I (0 to 150 (F) seconds)
99 Siren Shutdown (X 2 Mins) I_4_I (8 Minutes)
100 Zone 1 Type I_?_I (1 = Day Zone)
(2 = 24 Hour (Fire/Panic Zone)
(3 = Entry/Exit)
(4 = Interior Delay)
(5 = Interior Follower)
(6 = Instant/Perimeter)
(7 = 24 Hour Silent)
101 Zone 2 Type I_?_I
102 Zone 3 Type I_?_I
103 Zone 4 Type I_?_I
104 Zone 5 Type I_?_I
105 Zone 6 Type I_?_I
106-107 Duress Code I_2_I_2_I (Sends 22)
108-109 Fire Panic Report Code ( 1 & 3 ) I_3_I_2_I (Sends 23)
110-111 Med Panic Report Code ( 4 & 6 ) I_6_I_2_I (Sends 26)
112-113 Police Panic Report Code (* & # ) I_1_I_2_I (Sends 21, 00 = disabled)
114-115 Tamper Report Code I_0_I_0_I (00 = Disabled)
(If enabled also locks keypad for 1 minute after 30 random keypresses)
116-117 EEPROM Checksum Error Report I_0_I_0_I (00 = Disabled)
118 Closing Report Code I_0_I (0 = Disabled, if needed use 6)
119 Opening Report Code I_0_I (0 = Disabled, if needed use 5)
120-121 Zone 1 Report Code I_1_I_3_I (Sends 31)
122-123 Zone 2 Report Code I_2_I_3_I (Sends 32)
124-125 Zone 3 Report Code I_3_I_3_I (Sends 33)
126-127 Zone 4 Report Code I_4_I_3_I (Sends 34)
128-129 Zone 5 Report Code I_5_I_3_I (Sends 35)
130-131 Zone 6 Report Code I_6_I_3_I (Sends 36, if Smoke use 61)
132-133 Holdup/Panic Zone Report Code I_9_I_2_I (Sends 29)
134-135 Fire Zone Report Code I_6_I_1_I (Sends 16)
136-137 AC Power Loss Report Code I_9_I_7_I (Sends 79)
138-139 Low Battery Report Code I_8_I_7_I (Sends 78)
140 Fire Trouble Report Code I_7_I (Sends 7 + Zone)
141 Zone Bypass Report Code I_0_I (0 = Disabled)
142 Restore Report Code I_0_I (0 = Disabled)
143 Cancel Report Code I_D_I (D (13) sends D1, D2 etc)
144 Communicator Abort
(Ends communication if Canx)
I_0_I (0 = Disabled)
(1 = Enabled)
145 Keypad Holdup/Panic Audible I_0_I (0 = Audible)
(1 = Silent)
146 Zone 1 Loop Response Time I_0_I (0 = 500 ms, 1 = 200 ms)
147 Zone 2 Loop Response Time I_0_I (0 = 500 ms, 1 = 200 ms)
148 Zone 3 Loop Response Time I_0_I (0 = 500 ms, 1 = 200 ms)
149 Zone 4 Loop Response Time I_0_I (0 = 500 ms, 1 = 200 ms)
150 Zone 5 Loop Response Time I_0_I (0 = 500 ms, 1 = 200 ms)
151 Zone 6 Loop Response Time I_0_I (0 = 500 ms, 1 = 200 ms)
152 Holdup/Panic Loop Response Time I_0_I (0 = 500 ms, 1 = 200 ms)
153 Fire Loop Response Time I_0_I (0 = 500 ms, 1 = 200 ms)
154 # of Alarms until Swinger I_3_I (0 Disabled)
(1 to F = Number of Alarms)
155 Auto Bypass/Instant Arming I_0_I (0 = Disabled)
(1 = Instant Drs/Motion Off)
(3 = Delay Drs, Motion Off)
156 Siren Driver/1Amp Voltage Output I_1_I (0 = Internal Siren Driver)
(1 = External Siren Driver)
(If using Exterior Siren set panel jumper to VOLTAGE)
(If using internal Siren Driver set panel jumper to SIREN)
157 Keypad LED Extinguish I_0_I (0 = Disabled)
(1 = LED off after 60 sec)
158 Dial Attempts I_8_I (1 to 15 (F) Attempts)
159 Power Up Condition I_0_I (0 = Last Condition)
(1 = Power up Disarmed)
(2 = Power up Armed)
160 Power Up Delay (Zones) I_0_I (0 = 60 second Delay)
(1 = No Delay)
161 Immediate Rstr By Zone I_0_I (0 = Restore at Siren Timeout)
(1 = Restore immediate)
162 No Arming with a Zone Bypassed I_0_I (0 = Disabled)
(1 = Enabled)
163 Quickarm Digit I_0_I (0 = Quickarm Disabled)
(1 to 9 Quickarms system)
(Do not use a digit that conflicts with Installer Code!)
164 Fire Siren Cutoff Inhibit I_0_I (0 = Shutdown at Siren Timeout)
(1 = Siren until Code Disarm)
165 Double Line Extended I_0_I (0 = Disabled)
(1 = Enabled)
166 Siren/Bell Test (1 & 7 keys) I_1_I (0 = Disabled)
(1 = Enabled)
167 Resettable Aux Power (Smoke) I_1_I (0 = Reset by # if Fire LED on)
(1 = Power Reset by # alone)
168 European Dialing I_0_I (0 = Disabled)
(1 = Enabled)
169 Auxiliary Output 1 I_2_I (Panic)
170 Auxiliary Output 2 I_1_I (Fire)
171 Auxiliary Output 3 I_0_I (Burg)
172 Auxiliary Output 4 I_3_I (Armed)
173 Auxiliary Output Inversion I_1_I (1 = Invert Auxiliary 1 Output)
(2 = Invert Auxiliary 2 Output)
(4 = Invert Auxiliary 3 Output)
(8 = Invert Auxiliary 4 Output)
174 AC Power Loss Delay I_0_I (0 = 5 minutes before Report)
(1 = Immediate Report)
175 Rings to Answer Download Call I_8_I (0 = Download Disabled)
(1 to 15 (F) = Number of Rings)
176-177 Dl Complete Standard Report Code I_0_I_0_I (00 = Disabled, if needed use EE)
178-179 Reserved I_ _I_ _I (Do not Program)
180 Installer Access Code Digit 1 I_9_I
181 Installer Access Code Digit 2 I_7_I (This is the Installer Code)
182 Installer Access Code Digit 3 I_1_I (By default it is blank)
183 Installer Access Code Digit 4 I_3_I
184 Reserved I_0_I (Normally do not Program)
185 Reserved I_0_I (Normally do not Program)
186 Reserved I_0_I (Normally do not Program)
187 Reserved I_0_I (Normally do not Program)
184 to 187 are format over-rides, if panel isn’t communicating correctly use 6 11 8 10
Exit Program Save with 220# ,move Slider Switch in Panel to “Run” position
If using Programmer save with 220# then unplug from panel
If using keypad save with 220#, exit programming with 230#
Next locations are only programmable by downloading
188-195 Control Panel Access Code I_8_I_9_I_0_I_0_I_0_I_0_I_0_I_0_I
196-203 Callback Phone Digits 1 – 8 I_0_I_0_I_0_I_0_I_0_I_0_I_0_I_0_I
204-211 Callback Phone Digits 9 – 16 I_0_I_0_I_0_I_0_I_0_I_0_I_0_I_0_I
212 Answering Machine Defeat I_1_I (0 = Disabled)
(1 = 1 Ring/Hang/Ring)
213 Local Programming Lockout I_0_I (0 = Not Locked)
(0 = Keypad Program Enable)
(5 = No Local Programming)
(A = Communication Locked)
214 Control Panel Shutdown I_0_I (0 = System On)
(A = System Shutdown)