Bosch Radionics DS7400XI Basics

Zones 8 onboard, up to 128 with expansion modules
Battery 12 volt rechargeable Gel-Cell inside main panel
AC Transformer 16.5 volts screwed into outlet somewhere in house
Partitions 8
Wireless No
Downloadable Yes (RPS) Only Rev 4 panels
Panic Buttons Police, Fire and Medical
Arm Away User Code + ON
Stay Arm User Code + PERIMETER ONLY
Instant Arm User Code + NO ENTRY + PERIMETER ONLY
Custom Arm User Code + # + 4 (Arms only certain sensors)
Quick Arm
(if Available)
Arm Away = # + ON
Arm Stay = # + PERIMETER ONLY
Arm Instant = # + NO DELAY + PERIMETER ONLY
Disarm User Code + #
Bypass User Code + BYPASS + Zone (1 to 128)
Clear Bypass User Code + BYPASS + *
Force Arm User Code + ON or PERIMETER ONLY + BYPASS (Arms with Zones Open)
Reset Smoke User Code + SYSTEM RESET
Reset Zones User Code + SYSTEM RESET
Change
Partition
User Code + # + #
Door Chimes User Code + # + 7
Alarm History User Code + # + 8 + 9, scroll events with #
Clear Memory User Code + OFF + User Code + SYSTEM RESET
Zone Test 1. User Code + # + 8 + 1
2. Open Zones (Zone lights flash on untested zones)
3. User Code + # exits
Battery Test User Code + SYSTEM RESET
Siren Test User Code + # + 8 + 5
Phone Test User Code + # + 8 + 2
Set Date 1. Master Code + # + 0 + 2
2. Enter Month (01 = January to 12 = December)
3. Enter Day (01 to 31)
4. Enter Last 2 digits of Year (2000 = 00)
5. Press # to save and exit
Set Time 1. Master Code + # + 0 + 6
2. Enter Day (1 = Sunday to 7 = Saturday)
3. Enter Time in Military Format (0100 to 1259)
4. Enter 4 if AM or 6 if PM
5. Press # to save and exit
Read Time Master Code + # + 0 + 6 + # (LCD Keypads only)