Bosch Radionics DS7400XI Basics
Zones | 8 onboard, up to 128 with expansion modules |
Battery | 12 volt rechargeable Gel-Cell inside main panel |
AC Transformer | 16.5 volts screwed into outlet somewhere in house |
Partitions | 8 |
Wireless | No |
Downloadable | Yes (RPS) Only Rev 4 panels |
Panic Buttons | Police, Fire and Medical |
Arm Away | User Code + ON |
Stay Arm | User Code + PERIMETER ONLY |
Instant Arm | User Code + NO ENTRY + PERIMETER ONLY |
Custom Arm | User Code + # + 4 (Arms only certain sensors) |
Quick Arm (if Available) |
Arm Away = # + ON Arm Stay = # + PERIMETER ONLY Arm Instant = # + NO DELAY + PERIMETER ONLY |
Disarm | User Code + # |
Bypass | User Code + BYPASS + Zone (1 to 128) |
Clear Bypass | User Code + BYPASS + * |
Force Arm | User Code + ON or PERIMETER ONLY + BYPASS (Arms with Zones Open) |
Reset Smoke | User Code + SYSTEM RESET |
Reset Zones | User Code + SYSTEM RESET |
Change Partition |
User Code + # + # |
Door Chimes | User Code + # + 7 |
Alarm History | User Code + # + 8 + 9, scroll events with # |
Clear Memory | User Code + OFF + User Code + SYSTEM RESET |
Zone Test |
1. User Code + # + 8 + 1 2. Open Zones (Zone lights flash on untested zones) 3. User Code + # exits |
Battery Test | User Code + SYSTEM RESET |
Siren Test | User Code + # + 8 + 5 |
Phone Test | User Code + # + 8 + 2 |
Set Date |
1. Master Code + # + 0 + 2 2. Enter Month (01 = January to 12 = December) 3. Enter Day (01 to 31) 4. Enter Last 2 digits of Year (2000 = 00) 5. Press # to save and exit |
Set Time |
1. Master Code + # + 0 + 6 2. Enter Day (1 = Sunday to 7 = Saturday) 3. Enter Time in Military Format (0100 to 1259) 4. Enter 4 if AM or 6 if PM 5. Press # to save and exit |
Read Time | Master Code + # + 0 + 6 + # (LCD Keypads only) |