Bosch Radionics D8112g1 Program

Programming only by downloading, 5200 Programmer or 5100 “Wand” Programmer
Plug programmer in and momentarily short terminal 32 to 29 to enable program mode
Having many devices (keypads, OctoPopits, etc) interferes with programming
Disconnect all devices from Terminal 31 then load program again
When finished programming must Disable/Restart
Command 59 shows panel revision
8112E1 must be programmed for BFSK format
This is not a complete, it only shows the basics like a 5200 Programmer would display

  Variables/Defaults
PRIMARY CENTRAL ST.
1 Off I_NO_I Yes/No Yes = System Disabled, No = System Enabled
2 Local I_NO_I Yes/No Yes = Communicator OFF, No = Communicator ON
3 CS I_7_I 1 to 6 1 = Silent Knight Low Speed Double Round
2 = Ademco Low Speed Double Round
3 = Silent Knight High Speed Double Round
4 = Ademco High Speed Double Round
5 = Radionics Single Round with Parity Digit
6 = Radionics BFSK Superfast Single Round
7 = Radionics Modem II
Blank = Sescoa, Franklin Hi Speed Double Round
If Virtual Receiver use 6
If Rad Receiver use 7

The 8112E1 can only do BFSK!

4 SgRd I_NO_I Yes/No Yes = Single Round with Checksum (Format 5 only)
No = Disabled
5 Ack14 I_NO_I Yes/No Yes = 1400Hz Ack tone, No if Modem II Format used
6 Ack23 I_YES_I Yes/No Yes = 2300Hz Ack tone, No if Modem II Format used
7 P I_1_I_8_I_0_I_0_I_ _I_ _I_ _I
C = 3 second pause D = 7 sec Tone pause
8-digits 0 to 9, C to D, Blank (Phone Prefix)
8 Ph I_?_I_?_I_?_I_?_I_?_I_?_I_?_I 7-digits 0 to 9, C to D, Blank (Rest of Phone Number)

ADDITIONAL PHONE
9 DTMF I_YES_I Yes/No Yes = TouchTone Dialing, No = Pulse Dialing
10 BzFail I_NO_I Yes/No Yes = Buzzer if Fail to Communicate, No = Disabled
11 PhSupv I_ _I 10-150 sec/Blank Blank = No Phone Supervision
12 PhBel I_NO_I Yes/No Yes = Bell/Siren if Phone Trouble, No = Disabled
13 2Line I_NO_I Yes/No Yes = Use 2 Phone Lines, No = Disabled
(Radionics D128 Module required)
14 PhLite I_NO_I Yes/No Yes = Phone Line Status Lites, No = Disabled
(Radionics D128 Module required)
15 PhT/R I_NO_I Yes/No Yes = Send Phone Trouble/Restorals, No = Disabled
(Radionics D128 Module required)
(Primary Line reports a Zone B, Secondary is Zone C)

CALL ROUTING
16 Route I_ _I 0 to 7, Blank
BLANK = No Alternate Phone Number, all reports to Primary
1 = Primary = All Reports, Alternate Duplicate Reports
2 = Primary = All Reports, Alternate = Reports from Designated Zones
3 = Primary = All Reports, Alternate = Alarms from Designated Zones
4 = Primary = All Reports, Alternate = Backup Primary for Alarms
5 = Primary = All Reports, Alternate = Backup Primary for ALL Reports
6 = Primary = Supervisory Reports, Alternate = Alarm Reports
7 = Primary = Supervisory Reports, Backs up ALL Reports
Alternate = Alarm Reports, Backs up Zone Reports
17 AltZn I_ _I 0 to 8/Blank Highest Zone number reporting to Alternate Phone
(use only if section 16 is set at 2 or 3)

ALTERNATE CENTRAL
18 ACS I_7_I 1 to 6 1 = Silent Knight Low Speed Double Round
2 = Ademco Low Speed Double Round
3 = Silent Knight High Speed Double Round
4 = Ademco High Speed Double Round
5 = Radionics Single Round with Parity Digit
6 = Radionics BFSK Superfast Single Round
7 = Radionics Modem II
Blank = Sescoa, Franklin Hi Speed Double Round
If Virtual Receiver use 6
If Rad Receiver use 7
19 ASgRd I_NO_I Yes/No Yes = Single Round with Checksum (Format 5 only)
No = Disabled
20 AP I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I
C = 3 sec pause D = 7 sec Tone pause
8-digits 0 to 9, C to D, Blank (Not Used)
21 APh I_ _I_ _I_ _I_ _I_ _I_ _I_ _I 7-digits 0 to 9, C to D, Blank (Not Used)

ACCOUNT NO. / SUPERVISORY
22 Acct I_ _I_ _I_ _I_ _I 0 to 9, B to F, Blank Enter 3 digit Account if BFSK or 4/2 used (Virtual)
(1st digit Blank if 3-digit account)
Enter 4 digit Account if Modem II used (Radionics)
23 Tbl I_F_I 0 to 9, B to F, Blank Blank = No Report
F is automatic if BFSK or Modem II used
24 Res I_ _I 0 to 9, B to F, Blank Blank = No Report
E is automatic if BFSK or Modem II used
25 ExT/R I_YES_I Yes/No Expanded Trouble/Restoral by Zone
(Automatic if report formats 6 and 7 used)
26 DlyRes I_NO_I Yes/No Yes = Delay Restorals til Bell Timeout, No = Disabled
27 ACRes I_NO_I Yes/No Yes = AC Restoral reports as Zone 0, No = Disabled
(BFSK or Modem Format required
28 BatSupv I_YES_I Yes/No Yes = Bat Restoral reports as Zone 9, No = Disabled

INTERROGATION / REMOTE
29 AnsArm I_0_I_5_I 1 to 14, Blank # of Rings to Answer Downloader if Armed
30 AnsDis I_1_I_2_I 1 to 14, Blank # of Rings to Answer Downloader if Disarmed
31 Ring I_NO_I Yes/No Yes = Ring is 1 second or less, No = Disabled
(if in doubt make this Yes)
32 CSPrg I_YES_I Yes/No Yes = Remote Programming Enabled
33 Cmd43 I_YES_I Yes/No Yes = Allow Command 43 to initiate downloading
34 Pass I_9_I_9_I_9_I_9_I 0 to 9, B to F, Blank Remote Programming Passcode, Blank = Disabled

AUTOMATIC TEST REPT
35 Intvl I_0_I 0 to 99, Blank Automatic Test Time Interval in Hours
36 Days I_YES_I Yes/No Yes = Convert Hours Test to Days Test
(then set location 35 to 28 if Test report needed)
37 Month I_YES_I Yes/No Yes = Calender = 7 day cycle, No = 28 day cycle
38 50Hz I_NO_I Yes/No Yes = 50Hz AC, No = 60Hz AC
39 TsCode I_ _I 0 to 9 – B to F, Blank Non-Expanded Test Code, Blank = Disabled
40 TsE I_YES_I Yes/No Yes = Send Zone Restoral E at Test Time
41 TsAlt I_NO_I Yes/No Yes = Send Restoral Zone E to Alternate Phone
42 TsStat I_NO_I Yes/No Yes = Send Status Report at Test Time
43 TsDis I_YES_I Yes/No Yes = Test Report while system Disarmed
44 TsArm I_YES_I Yes/No Yes = Test Report while system Armed
45 TsDef I_NO_I Yes/No Yes = Test Report Defered if any other report is
sent during test interval
46 TsCir I_NO_I Yes/No Yes = Clear all Shunts at Test Time
47 ArmSys I_NO_I Yes/No Yes = Unconditionally Arm system at Test Time

ARM / DISARM SUPERVISION
48 Open I_0_I 0 to 9, B to F, Blank Opening Report Code (Enter B if Modem II Format)
49 Close I_0_I 0 to 9, B to F, Blank Closing Report Code (Enter C if Modem II Format)
50 ReO/C I_NO_I Yes/No Yes = Restricted O/C Reports only when Force
Arming or Disarming after an Alarm
51 Supv9 I_NO_I Yes/No Yes = Supervision O/C of Codes starting with 9
52 Cancel I_ _I 0 to 9, B to F, Blank Cancel Report Code (Enter D if Modem II Format)
53 Duress I_ _I 0 to 9, Blank Duress Alarm Zone Assignment
(Program as silent or invisible zone
54 CombID I_NO_I Yes/No Yes = O/C Reports sent as Zones

Comb 1 = Zone B Comb 91 = Zone 1
Comb 2 = Zone C Comb 92 = Zone 2
Comb 3 = Zone D Comb 93 = Zone 3
Comb 4 = Zone E Comb 94 = Zone 4
Comb 5 = Zone F Comb 95 = Zone 5
Comb 6 = Zone 6 Comb 96 = Zone 0
Comb 7 = Zone 7 Command 1 = Zone 9
Comb 8 = Zone 8    

ARM / DISARM COMBOS
55 Comb 1 I_ _I_ _I_ _I_ _I 0 to 9, Blank Enter 4 digits, 1st digit is automatically hardcoded
by user number
Example: if Comb 1 is 4444 the actual code is 14444
56 Comb 2 I_ _I_ _I_ _I_ _I 0 to 9, Blank
57 Comb 3 I_ _I_ _I_ _I_ _I 0 to 9, Blank
58 Comb 4 I_ _I_ _I_ _I_ _I 0 to 9, Blank
59 Comb 5 I_ _I_ _I_ _I_ _I 0 to 9, Blank
60 Comb 6 I_ _I_ _I_ _I_ _I 0 to 9, Blank
61 Comb 7 I_ _I_ _I_ _I_ _I 0 to 9, Blank
62 Comb 8 I_ _I_ _I_ _I_ _I 0 to 9, Blank
63 Comb 91 I_ _I_ _I_ _I_ _I 0 to 9, Blank Example: if Comb 91 is 4444 the actual code is 914444
64 Comb 92 I_ _I_ _I_ _I_ _I 0 to 9, Blank
65 Comb 93 I_ _I_ _I_ _I_ _I 0 to 9, Blank
66 Comb 94 I_ _I_ _I_ _I_ _I 0 to 9, Blank
67 Comb 95 I_ _I_ _I_ _I_ _I 0 to 9, Blank
68 Comb 96 I_ _I_ _I_ _I_ _I 0 to 9, Blank

ENTRY / EXIT DELAY
69 DlyIn I_ _I 10 to 150, Blank Entry Delay in Seconds, Blank = No Entry Delay
70 DlyOut I_ _I 10 to 150, Blank Exit Delay in Seconds, Blank = No Exit Delay
71 Prewarn I_YES_I Yes/No Yes = Prewarning Buzzer during Entry Delay
72 Bell I_00_I 2 to 99, 00 Bell Output Time in Minutes, 00 = No Bell Output

BELL OUTPUT / LISTEN
73 1Ring I_YES_I Yes/No Yes = 1 Ring per Zone for Non-Fire Alarms (Swinger)
74 TsBell I_NO_I Yes/No Yes = Bell Test at Arming, No = Disabled
75 Pulse I_YES_I Yes/No Yes = Pulse Bell output Terminal 6 for Fire
76 Listen I_0_I 1 to 15, 0 Listen-In Time in Minutes
(D180A Audio Amplifier or OmegaVision Required)
77 Hush I_NO_I Yes/No Yes = Burglar Alarm Bell silenced during Listen-In

ARMING STATION
78 MCArm I_NO_I Yes/No Yes = Maintained Keyswitch Arming, No = Momentary
(Terminals 26 and 29 used for Keyswitch)
79 ArmLED I_NO_I Yes/No Yes = Armed Status LED output for Keyswitch Arming
(Terminals 31 and 29 with 1K resistor used for LED)
80 Blink I_NO_I Yes/No Yes = Blink Armed Status LED after an Alarm

ARMING COMMANDS
81 Slave I_NO_I No This item is not used and should always be No
82 Cmd99 I_ _I_ _I_ _I_ _I 1 to 9, Blank Restricts COMMAND Bar functions
Enter 1 to 4 digits, do not enter 0, 9 should not be
the last digit, if Blank the COMMAND Bar is not
restricted and operates normally
83 CMD1 I_NO_I Yes/No Yes = COMMAND 1 Master Arms system
84 CMD2 I_NO_I Yes/No Yes = COMMAND 2 Instant Arms system, no E/E Delay
85 CMD3 I_NO_I Yes/No Yes = COMMAND 8 Delay Arms Perimeter
86 CMD8 I_NO_I Yes/No Yes = COMMAND 8 Peimeter Arms w/Entry Exit Delay
>
FORCE ARMING
87 FAMax I_ _I 1 to 9, Blank Maximum number of zones that can be Force Armed
Blank = No Force Arming allowed
88 FA1 I_NO_I Yes/No Yes = Force Arm using COMMAND 1 Master Arm
89 FA2 I_NO_I Yes/No Yes = Force Arm using COMMAND 2 Perimeter Arm
90 FA3 I_NO_I Yes/No Yes = Force Arm using COMMAND 3 Perimeter Delay

TEST COMMANDS
91 Cmd41 I_NO_I Yes/No Yes = Enable COMMAND 41
(Sends unexpanded Restoral Reports)
92 Cmd42 I_NO_I Yes/No Yes = Enable COMMAND 42
(Sends Complete System Status Reports)
93 Cmd44 I_NO_I Yes/No Yes = Enable COMMAND 44
(Initiate local system test)

SPECIAL COMMANDS
94 Cmd47 I_NO_I Yes/No Yes = Enable COMMAND 47
(Interrupts power to Terminal 8, Smoke Reset)
95 Cmd5 I_NO_I Yes/No Yes = Enable COMMAND 5
(Allows User to change Codes)
96 Cmd6 I_NO_I Yes/No Yes = Enable COMMAND 6
(Watch Mode/Door Chimes)
97 Cmd7 I_ _I 0 to 9, Blank Enables COMMAND 7 Special Alarm
1 to 8 = Alarm Zone 1 – 8 Bell Response assigned to
that zone
0 or 9 = Alarm Zone 0 or 9 does not sound siren
98 Cmd9 I_ _I 0 to 9, Blank Enables COMMAND 9 Special Alarm
1 to 8 = Alarm Zone 1 – 8 Bell Response assigned to
that zone
0 or 9 = Alarm Zone 0 or 9 does not sound siren

SPECIAL ALPHA CMD
99 ShntMA I_NO_I Yes/No Yes = Enable Zone shunting if Master Armed
100 ShntPA I_NO_I Yes/No Yes = Enable Zone shunting if Perimeter Armed
101 Clock I_NO_I Yes/No Yes = Enable Clock on Alpha Keypads
102 Serv I_YES_I Yes/No Yes = Alpha Keypad displays SERVICE on
Non-Fire Zone Troubles
103 Show I_YES_I Yes/No Yes = Show Zone faults while Disarmed
104 OnBat I_NO_I Yes/No Yes = Enables Low Battery Display/Buzzer

ZONE FUNCTION CODE
105 Zone1 I_ _I_ _I_ _I_ _I 1 to 8, Blank Zone 1 Reponse Code, Blank = Zone Disabled
106 Zone1 I_ _I_ _I_ _I_ _I A to Z, 0 to 9, Blank Zone 1 Alpha Display, up to 8 characters
107 Zone2 I_ _I_ _I_ _I_ _I 1 to 8, Blank Zone 2 Reponse Code, Blank = Zone Disabled
108 Zone2 I_ _I_ _I_ _I_ _I A to Z, 0 to 9, Blank Zone 2 Alpha Display, up to 8 characters
109 Zone3 I_ _I_ _I_ _I_ _I 1 to 8, Blank Zone 3 Reponse Code, Blank = Zone Disabled
110 Zone3 I_ _I_ _I_ _I_ _I A to Z, 0 to 9, Blank Zone 3 Alpha Display, up to 8 characters
111 Zone4 I_ _I_ _I_ _I_ _I 1 to 8, Blank Zone 4 Reponse Code, Blank = Zone Disabled
112 Zone4 I_ _I_ _I_ _I_ _I A to Z, 0 to 9, Blank Zone 4 Alpha Display, up to 8 characters
113 Zone5 I_ _I_ _I_ _I_ _I 1 to 8, Blank Zone 5 Reponse Code, Blank = Zone Disabled
114 Zone5 I_ _I_ _I_ _I_ _I A to Z, 0 to 9, Blank Zone 5 Alpha Display, up to 8 characters
115 Zone6 I_ _I_ _I_ _I_ _I 1 to 8, Blank Zone 6 Reponse Code, Blank = Zone Disabled
116 Zone6 I_ _I_ _I_ _I_ _I A to Z, 0 to 9, Blank Zone 6 Alpha Display, up to 8 characters
117 Zone7 I_ _I_ _I_ _I_ _I 1 to 8, Blank Zone 7 Reponse Code, Blank = Zone Disabled
118 Zone7 I_ _I_ _I_ _I_ _I A to Z, 0 to 9, Blank Zone 7 Alpha Display, up to 8 characters
119 Zone8 I_ _I_ _I_ _I_ _I 1 to 8, Blank Zone 8 Reponse Code, Blank = Zone Disabled
120 Zone8 I_ _I_ _I_ _I_ _I A to Z, 0 to 9, Blank Zone 8 Alpha Display, up to 8 characters
121 Modem I_NO_I Yes/No This must always be programmed as No
122 ExRam I_NO_I Yes/No Yes = Expanded RAM capacity if loaded with
8112:AUX handler, is YES if 8112G2 and
8112A (do NOT enable for 8112E & 8112E1)

MODEM & EXPAM
123 16ChDisp I_NO_I Yes/No Yes = Enable 16-Character Display for Alpha II
No = 8-Character Display (non-Alpha II keypads)