Variables/Defaults |
PRIMARY CENTRAL ST. |
|
1 |
Off |
I_NO_I |
Yes/No |
Yes = System Disabled, No = System Enabled |
|
2 |
Local |
I_NO_I |
Yes/No |
Yes = Communicator OFF, No = Communicator ON |
|
3 |
CS |
I_7_I |
1 to 6 |
1 = Silent Knight Low Speed Double Round
2 = Ademco Low Speed Double Round
3 = Silent Knight High Speed Double Round
4 = Ademco High Speed Double Round
5 = Radionics Single Round with Parity Digit
6 = Radionics BFSK Superfast Single Round
7 = Radionics Modem II
Blank = Sescoa, Franklin Hi Speed Double Round
|
|
|
|
If Virtual Receiver use 6
If Rad Receiver use 7
The 8112E1 can only do BFSK!
|
|
4 |
SgRd |
I_NO_I |
Yes/No |
Yes = Single Round with Checksum (Format 5 only)
No = Disabled
|
|
5 |
Ack14 |
I_NO_I |
Yes/No |
Yes = 1400Hz Ack tone, No if Modem II Format used |
|
6 |
Ack23 |
I_YES_I |
Yes/No |
Yes = 2300Hz Ack tone, No if Modem II Format used |
|
7 |
P |
I_1_I_8_I_0_I_0_I_ _I_ _I_ _I
C = 3 second pause D = 7 sec Tone pause
|
8-digits 0 to 9, C to D, Blank (Phone Prefix) |
|
8 |
Ph |
I_?_I_?_I_?_I_?_I_?_I_?_I_?_I |
7-digits 0 to 9, C to D, Blank (Rest of Phone Number)
|
ADDITIONAL PHONE |
|
9 |
DTMF |
I_YES_I |
Yes/No |
Yes = TouchTone Dialing, No = Pulse Dialing |
|
10 |
BzFail |
I_NO_I |
Yes/No |
Yes = Buzzer if Fail to Communicate, No = Disabled |
|
11 |
PhSupv |
I_ _I |
10-150 sec/Blank |
Blank = No Phone Supervision |
|
12 |
PhBel |
I_NO_I |
Yes/No |
Yes = Bell/Siren if Phone Trouble, No = Disabled |
|
13 |
2Line |
I_NO_I |
Yes/No |
Yes = Use 2 Phone Lines, No = Disabled
(Radionics D128 Module required)
|
|
14 |
PhLite |
I_NO_I |
Yes/No |
Yes = Phone Line Status Lites, No = Disabled
(Radionics D128 Module required)
|
|
15 |
PhT/R |
I_NO_I |
Yes/No |
Yes = Send Phone Trouble/Restorals, No = Disabled
(Radionics D128 Module required)
(Primary Line reports a Zone B, Secondary is Zone C)
|
CALL ROUTING |
|
16 |
Route |
I_ _I |
0 to 7, Blank
BLANK = No Alternate Phone Number, all reports to Primary
1 = Primary = All Reports, Alternate Duplicate Reports
2 = Primary = All Reports, Alternate = Reports from Designated Zones
3 = Primary = All Reports, Alternate = Alarms from Designated Zones
4 = Primary = All Reports, Alternate = Backup Primary for Alarms
5 = Primary = All Reports, Alternate = Backup Primary for ALL Reports
6 = Primary = Supervisory Reports, Alternate = Alarm Reports
7 = Primary = Supervisory Reports, Backs up ALL Reports
Alternate = Alarm Reports, Backs up Zone Reports
|
|
17 |
AltZn |
I_ _I |
0 to 8/Blank |
Highest Zone number reporting to Alternate Phone
(use only if section 16 is set at 2 or 3)
|
ALTERNATE CENTRAL |
|
18 |
ACS |
I_7_I |
1 to 6 |
1 = Silent Knight Low Speed Double Round
2 = Ademco Low Speed Double Round
3 = Silent Knight High Speed Double Round
4 = Ademco High Speed Double Round
5 = Radionics Single Round with Parity Digit
6 = Radionics BFSK Superfast Single Round
7 = Radionics Modem II
Blank = Sescoa, Franklin Hi Speed Double Round
|
|
|
|
If Virtual Receiver use 6
If Rad Receiver use 7
|
|
19 |
ASgRd |
I_NO_I |
Yes/No |
Yes = Single Round with Checksum (Format 5 only)
No = Disabled
|
|
20 |
AP |
I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I
C = 3 sec pause D = 7 sec Tone pause
|
8-digits 0 to 9, C to D, Blank (Not Used) |
|
21 |
APh |
I_ _I_ _I_ _I_ _I_ _I_ _I_ _I |
7-digits 0 to 9, C to D, Blank (Not Used)
|
ACCOUNT NO. / SUPERVISORY |
|
22 |
Acct |
I_ _I_ _I_ _I_ _I |
0 to 9, B to F, Blank |
Enter 3 digit Account if BFSK or 4/2 used (Virtual)
(1st digit Blank if 3-digit account)
Enter 4 digit Account if Modem II used (Radionics)
|
|
23 |
Tbl |
I_F_I |
0 to 9, B to F, Blank |
Blank = No Report
F is automatic if BFSK or Modem II used
|
|
24 |
Res |
I_ _I |
0 to 9, B to F, Blank |
Blank = No Report
E is automatic if BFSK or Modem II used
|
|
25 |
ExT/R |
I_YES_I |
Yes/No |
Expanded Trouble/Restoral by Zone
(Automatic if report formats 6 and 7 used)
|
|
26 |
DlyRes |
I_NO_I |
Yes/No |
Yes = Delay Restorals til Bell Timeout, No = Disabled |
|
27 |
ACRes |
I_NO_I |
Yes/No |
Yes = AC Restoral reports as Zone 0, No = Disabled
(BFSK or Modem Format required
|
|
28 |
BatSupv |
I_YES_I |
Yes/No |
Yes = Bat Restoral reports as Zone 9, No = Disabled
|
INTERROGATION / REMOTE |
|
29 |
AnsArm |
I_0_I_5_I |
1 to 14, Blank |
# of Rings to Answer Downloader if Armed |
|
30 |
AnsDis |
I_1_I_2_I |
1 to 14, Blank |
# of Rings to Answer Downloader if Disarmed |
|
31 |
Ring |
I_NO_I |
Yes/No |
Yes = Ring is 1 second or less, No = Disabled
(if in doubt make this Yes)
|
|
32 |
CSPrg |
I_YES_I |
Yes/No |
Yes = Remote Programming Enabled |
|
33 |
Cmd43 |
I_YES_I |
Yes/No |
Yes = Allow Command 43 to initiate downloading |
|
34 |
Pass |
I_9_I_9_I_9_I_9_I |
0 to 9, B to F, Blank |
Remote Programming Passcode, Blank = Disabled
|
AUTOMATIC TEST REPT |
|
35 |
Intvl |
I_0_I |
0 to 99, Blank |
Automatic Test Time Interval in Hours |
|
36 |
Days |
I_YES_I |
Yes/No |
Yes = Convert Hours Test to Days Test
(then set location 35 to 28 if Test report needed)
|
|
37 |
Month |
I_YES_I |
Yes/No |
Yes = Calender = 7 day cycle, No = 28 day cycle |
|
38 |
50Hz |
I_NO_I |
Yes/No |
Yes = 50Hz AC, No = 60Hz AC |
|
39 |
TsCode |
I_ _I |
0 to 9 – B to F, Blank |
Non-Expanded Test Code, Blank = Disabled |
|
40 |
TsE |
I_YES_I |
Yes/No |
Yes = Send Zone Restoral E at Test Time |
|
41 |
TsAlt |
I_NO_I |
Yes/No |
Yes = Send Restoral Zone E to Alternate Phone |
|
42 |
TsStat |
I_NO_I |
Yes/No |
Yes = Send Status Report at Test Time |
|
43 |
TsDis |
I_YES_I |
Yes/No |
Yes = Test Report while system Disarmed |
|
44 |
TsArm |
I_YES_I |
Yes/No |
Yes = Test Report while system Armed |
|
45 |
TsDef |
I_NO_I |
Yes/No |
Yes = Test Report Defered if any other report is
sent during test interval
|
|
46 |
TsCir |
I_NO_I |
Yes/No |
Yes = Clear all Shunts at Test Time |
|
47 |
ArmSys |
I_NO_I |
Yes/No |
Yes = Unconditionally Arm system at Test Time
|
ARM / DISARM SUPERVISION |
|
48 |
Open |
I_0_I |
0 to 9, B to F, Blank |
Opening Report Code (Enter B if Modem II Format) |
|
49 |
Close |
I_0_I |
0 to 9, B to F, Blank |
Closing Report Code (Enter C if Modem II Format) |
|
50 |
ReO/C |
I_NO_I |
Yes/No |
Yes = Restricted O/C Reports only when Force
Arming or Disarming after an Alarm
|
|
51 |
Supv9 |
I_NO_I |
Yes/No |
Yes = Supervision O/C of Codes starting with 9 |
|
52 |
Cancel |
I_ _I |
0 to 9, B to F, Blank |
Cancel Report Code (Enter D if Modem II Format) |
|
53 |
Duress |
I_ _I |
0 to 9, Blank |
Duress Alarm Zone Assignment
(Program as silent or invisible zone
|
|
54 |
CombID |
I_NO_I |
Yes/No |
Yes = O/C Reports sent as Zones
Comb 1 = Zone B |
Comb 91 = Zone 1 |
Comb 2 = Zone C |
Comb 92 = Zone 2 |
Comb 3 = Zone D |
Comb 93 = Zone 3 |
Comb 4 = Zone E |
Comb 94 = Zone 4 |
Comb 5 = Zone F |
Comb 95 = Zone 5 |
Comb 6 = Zone 6 |
Comb 96 = Zone 0 |
Comb 7 = Zone 7 |
Command 1 = Zone 9 |
Comb 8 = Zone 8 |
|
ARM / DISARM COMBOS |
|
55 |
Comb 1 |
I_ _I_ _I_ _I_ _I |
0 to 9, Blank |
Enter 4 digits, 1st digit is automatically hardcoded
by user number
Example: if Comb 1 is 4444 the actual code is 14444
|
|
56 |
Comb 2 |
I_ _I_ _I_ _I_ _I |
0 to 9, Blank |
|
57 |
Comb 3 |
I_ _I_ _I_ _I_ _I |
0 to 9, Blank |
|
58 |
Comb 4 |
I_ _I_ _I_ _I_ _I |
0 to 9, Blank |
|
59 |
Comb 5 |
I_ _I_ _I_ _I_ _I |
0 to 9, Blank |
|
60 |
Comb 6 |
I_ _I_ _I_ _I_ _I |
0 to 9, Blank |
|
61 |
Comb 7 |
I_ _I_ _I_ _I_ _I |
0 to 9, Blank |
|
62 |
Comb 8 |
I_ _I_ _I_ _I_ _I |
0 to 9, Blank |
|
63 |
Comb 91 |
I_ _I_ _I_ _I_ _I |
0 to 9, Blank |
Example: if Comb 91 is 4444 the actual code is 914444 |
|
64 |
Comb 92 |
I_ _I_ _I_ _I_ _I |
0 to 9, Blank |
|
65 |
Comb 93 |
I_ _I_ _I_ _I_ _I |
0 to 9, Blank |
|
66 |
Comb 94 |
I_ _I_ _I_ _I_ _I |
0 to 9, Blank |
|
67 |
Comb 95 |
I_ _I_ _I_ _I_ _I |
0 to 9, Blank |
|
68 |
Comb 96 |
I_ _I_ _I_ _I_ _I |
0 to 9, Blank
|
ENTRY / EXIT DELAY |
|
69 |
DlyIn |
I_ _I |
10 to 150, Blank |
Entry Delay in Seconds, Blank = No Entry Delay |
|
70 |
DlyOut |
I_ _I |
10 to 150, Blank |
Exit Delay in Seconds, Blank = No Exit Delay |
|
71 |
Prewarn |
I_YES_I |
Yes/No |
Yes = Prewarning Buzzer during Entry Delay |
|
72 |
Bell |
I_00_I |
2 to 99, 00 |
Bell Output Time in Minutes, 00 = No Bell Output
|
BELL OUTPUT / LISTEN |
|
73 |
1Ring |
I_YES_I |
Yes/No |
Yes = 1 Ring per Zone for Non-Fire Alarms (Swinger) |
|
74 |
TsBell |
I_NO_I |
Yes/No |
Yes = Bell Test at Arming, No = Disabled |
|
75 |
Pulse |
I_YES_I |
Yes/No |
Yes = Pulse Bell output Terminal 6 for Fire |
|
76 |
Listen |
I_0_I |
1 to 15, 0 |
Listen-In Time in Minutes
(D180A Audio Amplifier or OmegaVision Required)
|
|
77 |
Hush |
I_NO_I |
Yes/No |
Yes = Burglar Alarm Bell silenced during Listen-In
|
ARMING STATION |
|
78 |
MCArm |
I_NO_I |
Yes/No |
Yes = Maintained Keyswitch Arming, No = Momentary
(Terminals 26 and 29 used for Keyswitch)
|
|
79 |
ArmLED |
I_NO_I |
Yes/No |
Yes = Armed Status LED output for Keyswitch Arming
(Terminals 31 and 29 with 1K resistor used for LED)
|
|
80 |
Blink |
I_NO_I |
Yes/No |
Yes = Blink Armed Status LED after an Alarm
|
ARMING COMMANDS |
|
81 |
Slave |
I_NO_I |
No |
This item is not used and should always be No |
|
82 |
Cmd99 |
I_ _I_ _I_ _I_ _I |
1 to 9, Blank |
Restricts COMMAND Bar functions
Enter 1 to 4 digits, do not enter 0, 9 should not be
the last digit, if Blank the COMMAND Bar is not
restricted and operates normally
|
|
83 |
CMD1 |
I_NO_I |
Yes/No |
Yes = COMMAND 1 Master Arms system |
|
84 |
CMD2 |
I_NO_I |
Yes/No |
Yes = COMMAND 2 Instant Arms system, no E/E Delay |
|
85 |
CMD3 |
I_NO_I |
Yes/No |
Yes = COMMAND 8 Delay Arms Perimeter |
|
86 |
CMD8 |
I_NO_I |
Yes/No |
Yes = COMMAND 8 Peimeter Arms w/Entry Exit Delay > |
FORCE ARMING |
|
87 |
FAMax |
I_ _I |
1 to 9, Blank |
Maximum number of zones that can be Force Armed
Blank = No Force Arming allowed
|
|
88 |
FA1 |
I_NO_I |
Yes/No |
Yes = Force Arm using COMMAND 1 Master Arm |
|
89 |
FA2 |
I_NO_I |
Yes/No |
Yes = Force Arm using COMMAND 2 Perimeter Arm |
|
90 |
FA3 |
I_NO_I |
Yes/No |
Yes = Force Arm using COMMAND 3 Perimeter Delay
|
TEST COMMANDS |
|
91 |
Cmd41 |
I_NO_I |
Yes/No |
Yes = Enable COMMAND 41
(Sends unexpanded Restoral Reports)
|
|
92 |
Cmd42 |
I_NO_I |
Yes/No |
Yes = Enable COMMAND 42
(Sends Complete System Status Reports)
|
|
93 |
Cmd44 |
I_NO_I |
Yes/No |
Yes = Enable COMMAND 44
(Initiate local system test)
|
SPECIAL COMMANDS |
|
94 |
Cmd47 |
I_NO_I |
Yes/No |
Yes = Enable COMMAND 47
(Interrupts power to Terminal 8, Smoke Reset)
|
|
95 |
Cmd5 |
I_NO_I |
Yes/No |
Yes = Enable COMMAND 5
(Allows User to change Codes)
|
|
96 |
Cmd6 |
I_NO_I |
Yes/No |
Yes = Enable COMMAND 6
(Watch Mode/Door Chimes)
|
|
97 |
Cmd7 |
I_ _I |
0 to 9, Blank |
Enables COMMAND 7 Special Alarm
1 to 8 = Alarm Zone 1 – 8 Bell Response assigned to
that zone
0 or 9 = Alarm Zone 0 or 9 does not sound siren
|
|
98 |
Cmd9 |
I_ _I |
0 to 9, Blank |
Enables COMMAND 9 Special Alarm
1 to 8 = Alarm Zone 1 – 8 Bell Response assigned to
that zone
0 or 9 = Alarm Zone 0 or 9 does not sound siren
|
SPECIAL ALPHA CMD |
|
99 |
ShntMA |
I_NO_I |
Yes/No |
Yes = Enable Zone shunting if Master Armed |
|
100 |
ShntPA |
I_NO_I |
Yes/No |
Yes = Enable Zone shunting if Perimeter Armed |
|
101 |
Clock |
I_NO_I |
Yes/No |
Yes = Enable Clock on Alpha Keypads |
|
102 |
Serv |
I_YES_I |
Yes/No |
Yes = Alpha Keypad displays SERVICE on
Non-Fire Zone Troubles
|
|
103 |
Show |
I_YES_I |
Yes/No |
Yes = Show Zone faults while Disarmed |
|
104 |
OnBat |
I_NO_I |
Yes/No |
Yes = Enables Low Battery Display/Buzzer
|
ZONE FUNCTION CODE |
|
105 |
Zone1 |
I_ _I_ _I_ _I_ _I |
1 to 8, Blank |
Zone 1 Reponse Code, Blank = Zone Disabled |
|
106 |
Zone1 |
I_ _I_ _I_ _I_ _I |
A to Z, 0 to 9, Blank |
Zone 1 Alpha Display, up to 8 characters |
|
107 |
Zone2 |
I_ _I_ _I_ _I_ _I |
1 to 8, Blank |
Zone 2 Reponse Code, Blank = Zone Disabled |
|
108 |
Zone2 |
I_ _I_ _I_ _I_ _I |
A to Z, 0 to 9, Blank |
Zone 2 Alpha Display, up to 8 characters |
|
109 |
Zone3 |
I_ _I_ _I_ _I_ _I |
1 to 8, Blank |
Zone 3 Reponse Code, Blank = Zone Disabled |
|
110 |
Zone3 |
I_ _I_ _I_ _I_ _I |
A to Z, 0 to 9, Blank |
Zone 3 Alpha Display, up to 8 characters |
|
111 |
Zone4 |
I_ _I_ _I_ _I_ _I |
1 to 8, Blank |
Zone 4 Reponse Code, Blank = Zone Disabled |
|
112 |
Zone4 |
I_ _I_ _I_ _I_ _I |
A to Z, 0 to 9, Blank |
Zone 4 Alpha Display, up to 8 characters |
|
113 |
Zone5 |
I_ _I_ _I_ _I_ _I |
1 to 8, Blank |
Zone 5 Reponse Code, Blank = Zone Disabled |
|
114 |
Zone5 |
I_ _I_ _I_ _I_ _I |
A to Z, 0 to 9, Blank |
Zone 5 Alpha Display, up to 8 characters |
|
115 |
Zone6 |
I_ _I_ _I_ _I_ _I |
1 to 8, Blank |
Zone 6 Reponse Code, Blank = Zone Disabled |
|
116 |
Zone6 |
I_ _I_ _I_ _I_ _I |
A to Z, 0 to 9, Blank |
Zone 6 Alpha Display, up to 8 characters |
|
117 |
Zone7 |
I_ _I_ _I_ _I_ _I |
1 to 8, Blank |
Zone 7 Reponse Code, Blank = Zone Disabled |
|
118 |
Zone7 |
I_ _I_ _I_ _I_ _I |
A to Z, 0 to 9, Blank |
Zone 7 Alpha Display, up to 8 characters |
|
119 |
Zone8 |
I_ _I_ _I_ _I_ _I |
1 to 8, Blank |
Zone 8 Reponse Code, Blank = Zone Disabled |
|
120 |
Zone8 |
I_ _I_ _I_ _I_ _I |
A to Z, 0 to 9, Blank |
Zone 8 Alpha Display, up to 8 characters |
|
121 |
Modem |
I_NO_I |
Yes/No |
This must always be programmed as No |
|
122 |
ExRam |
I_NO_I |
Yes/No |
Yes = Expanded RAM capacity if loaded with
8112:AUX handler, is YES if 8112G2 and
8112A (do NOT enable for 8112E & 8112E1)
|
MODEM & EXPAM |
|
123 |
16ChDisp |
I_NO_I |
Yes/No |
Yes = Enable 16-Character Display for Alpha II
No = 8-Character Display (non-Alpha II keypads)
|