Bosch Radionics D6112 Program

Programming only by downloading, 5200 Programmer or 5100 “Wand” Programmer
Plug programmer in and momentarily short Reset Pin to Terminal 27 to enable program mode
If C1 to C6 use Modem II Format with 4-digit Account, if Virtual Receiver use BFSK with 3-digit Account
Command 43 will cause Panel to answer downloader call (if Command 43 is enabled)

1. Globals Variables/Defaults
1.1 Tbl I_F_I 0 to 9, B to F, Blank Blank = No Report
F is automatic if BFSK or Modem II used
1.2 Res I_ _I 0 to 9, B to F, Blank Blank = No Report
E is automatic if BFSK or Modem II used
1.3 Open I_ _I 0 to 9, B to F, Blank Blank = No Report
F is automatic if BFSK or Modem II used
1.4 Close I_ _I 0 to 9, B to F, Blank Blank = No Report
F is automatic if BFSK or Modem II used
1.5 Cancel I_ _I 0 to 9, B to F, Blank Blank = No Report
F is automatic if BFSK or Modem II used
1.6 Duress I_D_I 0 to 9, B to F, Blank Blank = No Report
D is automatic if BFSK or Modem II used
1.7 BatSupv I_ _I 0 to 9, B to F, Blank Blank = No Report
If needed use 9 (Trouble Zone 9)
1.8 Bell (timeout) I_0_I_6_I 0 to 63, Blank In minutes, Blank = No Bell Output
1.9 BzPhFail I_NO_I Yes/No No = No Pulse Buzzer for Comm Failure
1.10 BzACFail I_NO_I Yes/No No = No Pulse Buzzer for AC Failure
1.11 DTMF I_YES_I Yes/No Yes = TouchTone Dial, No = Pulse Dial
1.12 CSPrg I_YES_I Yes/No Yes = Enable Remote Downloading
1.13 Cmd43 I_YES_I Yes/No Yes = Enable COMMAND 43 for downloading
1.14 Pass I_9_I_9_I_9_I_9_I 0 to 9, B to F, Blank Remote Programming Passcode
1.15 AnsArm I_0_I_5_I 0 to 14, Blank # of Rings to Answer Downloader if Armed
1.16 AnsDis I_1_I_2_I 0 to 14, Blank # of Rings to Answer Downloader if Disarmed
1.17 AuxRlyTim I_ _I_ _I 2, 5, 10, 15 Aux Relay Contact closure time in seconds

2. PriPhone (Primary Phone Variables/Defaults
2.1 P I_1_I_8_I_0_I_0_I_ _I_ _I_ _I
C = 3 second pause D = 7 sec pause
8-digits 0 to 9, C to D, Blank (Phone Prefix)
2.2 Ph I_?_I_?_I_?_I_?_I_?_I_?_I_?_I 7-digits 0 to 9, C to D, Blank (Rest of Phone Number)
2.3 Modem I_YES_I Yes/No Yes = Modem Format, if No see section 2.4
2.4 CS I_6_I 1 to 6 Alternate Format if Modem not selected in 2.3
1 = Silent Knight Low Speed Double Round
2 = Ademco Low Speed Double Round
3 = Silent Knight High Speed Double Round
4 = Ademco High Speed Double Round
5 = Radionics Single Round with Parity Digit
6 = Radionics BFSK Superfast Single Round
Blank = Sescoa, Franklin Hi Speed Double Round
2.5 Ack14 I_NO_I Yes/No Yes = 1400Hz Ack tone, No if Modem Format used
2.6 EXT/R I_YES_I Yes/No Expanded Trouble/Restoral by Zone
2.7 Ack23 I_NO_I Yes/No Yes = 2300Hz Ack tone, No if Modem Format used

3. AltPhone (Alternate Phone) Variables/Defaults
3.1 AP I_ _I_ _I_ _I_ _I_ _I_ _I_ _I 8-digits 0 to 9, C to D, Blank (Do not use)
3.2 APh I_ _I_ _I_ _I_ _I_ _I_ _I_ _I 7-digits 0 to 9, Blank (Do not use)
3.3 Modem I_YES_I Yes/No Yes = Modem Format, if No see section 3.4
3.4 ACS I_7_I 1 to 6 Alternate Format if Modem not selected in 3.3
3.5 AAck14 I_NO_I Yes/No Yes = 1400Hz Ack tone, No if Modem Format used
3.6 AExT/R I_YES_I Yes/No Expanded Trouble/Restoral by Zone
3.7

3.8

3.9

AlarmRoute

OpClRoute

TblRoute

I_0_I

I_0_I

I_0_I

0 to 3

0 to 3

0 to 3

0 = Primary Phone Only
1 = Primary then Alternate Phone
2 = Alternate then Primary Phone
3 = Non-Designated Zones to Primary Phone
      Designated Zones to Alternate Phone
3.10 ResRoute I_0_I 0 to 3
3.11 AAck23 I_YES_I Yes/No Yes = 2300Hz Ack tone, No if Modem Format used
4. Devices (Keypads) Variables/Defaults
4.1 Device# I_?_I 1 to 4 Enter Device Address Number here to select
4.2 D1Model I_1_I 1 to 4 Enter Model of Device selected in 4.1
1 = D610/D611
2 = D620/D626
3 = D630/D636
4 = D640
4.3 D1Cmd I_YES_I Yes/No Enables COMMAND key on selected Device
4.4 D1Acct1 I_YES_I Yes/No Yes = Device uses Account 1, No = Account 2

5. CommandKeys (Function Keys) Variables/Defaults
5.1 Comb9 I_9_I_ _I_ _I_ _I 0 to 9, Blank Command Key Security Passcode
(Not used, 1st digit is hardcoded as 9)
5.2 Cmd1 I_YES_I Yes/No Enable Command 1 to Master Arm system
5.3 Cmd2 I_YES_I Yes/No Enable Command 2 to Instant Perimeter Arm
5.4 Cmd3 I_YES_I Yes/No Enable Command 3 to Delay Perimeter Arm
5.5 FA123 I_YES_I Yes/No Commands 1, 2 and 3 will Force Arm system
5.6 Cmd0 I_YES_I Yes/No Enable Command 0 for shunting in exit delay
5.7 FAMax I_1_I 0 to 9 Maximum number of Zones allowed by Force Arming
5.8 Cmd8 I_YES_I Yes/No Enable Command 8 for Delay Perimeter arming
5.9 Cmd41 I_NO_I Yes/No Enable Command 41 for unexpanded Restorals
5.10 Cmd42 I_YES_I Yes/No Enable Command 42 for System Trouble Reports
5.11 Cmd44 I_YES_I Yes/No Enable Command 44 for Local system test
5.12 Cmd47 I_YES_I Yes/No Enable Command 47 to reset Smoke Detectors
5.13 C47Shrt I_YES_I Yes/No Yes = 2-second Reset Time, No = 4 seconds
5.14 Cmd5 I_YES_I Yes/No Enable Command 5 for Passcode Change Mode
5.15 Cmd6 I_YES_I Yes/No Enable Command 6 for Watch Mode (Door Chimes)
5.16 C7RptCd I_7_I 0 to 9, Blank
0 to 9, B to F, Blank
(if using 4/2 BFSK) Command 7 Medical Report Code
(if using Modem II)
5.17 C7Bell I_NO_I Yes/No Disable Siren during Command 7 Medical Alarm
5.18 C7PisBel I_NO_I Yes/No Pulse Siren during Command 7 Medical Alarm
5.19 C7AuxRly I_NO_I Yes/No Activate Aux Relay during Command 7 Medical Alarm
5.20 C7DsgZn I_NO_I Yes/No Enable Command 7 as a Desginated Zone
5.21 C9RptCd I_9_I 0 to 9, Blank
0 to 9, B to F, Blank
(if using 4/2 BFSK) Command 9 Fire Report Code
(if using Modem II)
5.22 C9Bell I_YES_I Yes/No Enable Siren during Command 9 Fire Alarm
5.23 C9PisBel I_NO_I Yes/No Pulse Siren during Command 9 Fire Alarm
5.24 C9AuxRly I_NO_I Yes/No Activate Aux Relay during Command 9 Fire Alarm
5.25 C9DsgZn I_NO_I Yes/No Enable Command 9 as a Desginated Zone
5.26 AKey I_ _I_ _I 01 to 09, Blank “A” Function Key Operation
5.27 BKey I_ _I_ _I 01 to 09, Blank “B” Function Key Operation
5.28 CKey I_ _I_ _I 01 to 09, Blank “C” Function Key Operation
01 = CMD 41 Unexpanded Test Report 06 = CMD 5 Passcode Change Mode
02 = CMD 42 System Trouble Report 07 = CMD 6 Perimeter Watch Mode
03 = CMD 43 Initiate Remote Program 08 = CMD 7 Keypad Medical Alarm
04 = CMD 44 Local system Test 09 = Keypad Police Alarm
05 = CMD 47 Sensor Reset

6. Combinations (User Codes) Variables/Defaults
_ = Passcode Number
6.1 Comb# I_?_I 1 to 7 Enter number of Passcode to program
6.2 Comb_ I_ _I_ _I_ _I_ _I 0 to 9, Blank Enter 1 to 4 digit Passcode
(Passcodes start with user number, Example: Passcode 5 start with 5 + 1 – 4 digits)
6.3 C_Ovrd I_NO_I Yes/No Passcode overrides Opening/Closing Restrictions
6.4 C_Acct1 I_YES_I Yes/No Passcode Arms/Disarms for Account #1
6.5 C_Acct2 I_NO_I Yes/No Passcode Arms/Disarms for Account #2

7. Account #1 (Partition 1) Variables/Defaults
7.1 1Acct I_ _I_ _I_ _I_ _I
(1st digit Blank if 3-digit account)
0 to 9, B to F, Blank Enter 3 digit Account if BFSK or 4/2 used (Virtual)
Enter 4 digit Account if Modem II used (Radionics)
7.2 1Off I_NO_I Yes/No Yes = Disable all Functions except Remote Program
No = Normal operation
7.3 1Local I_NO_I Yes/No Yes = Disable Central Station Reports (Local System)
No = Enable Central Station Reports
7.4 1DlyIn I_30_I 10 to 120, Blank Entry Delay in 10 second increments
7.5 1DlyOut I_60_I 10 to 120, Blank Exit Delay in 10 second increments
7.6 1Prwrn I_YES_I Yes/No Sound Prewarning buzzer during Entry Delay
7.7 1Op/Cl I_NO_I Yes/No Enable Opening/Closing Reports for this Account
7.8 1ReOp I_NO_I Yes/No Enable Restricted Opening Reports (Disarm on Alarm)
7.9 1ReCl I_NO_I Yes/No Enable Restricted Closing Reports
(Send on Force Arm or if Command 0 used to Shunt)
7.10 1CombID I_NO_I Yes/No Identify Opening/Closing Reports by User Passcode
Combination 1 = Zone 1 Combination 5 = Zone 5
Combination 2 = Zone 2 Combination 6 = Zone 6
Combination 3 = Zone 3 Combination 7 = Zone 7
Combination 4 = Zone 4     Download or CMD 1 Arming = Zone 9
7.11 1CnclRpt I_NO_I Yes/No Enable Cancel Reports for this Account
7.12 1Duress I_NO_I Yes/No Enable Duress Reports for this Account
(Duress = 1 digit above User Passcode)
7.13 1DlyRes I_NO_I Yes/No Delay Restoral Reports until Bell Timeout
7.14 1Ring1 I_YES_I Yes/No 1 Alarm Output per Zone (Swinger Shutdown)
7.15 1TsBell I_NO_I Yes/No Automatic Bell Test after Arming
7.16 1Show I_YES_I Yes/No Show Zone Status while Disarmed
7.17 Acct1Zns I_8_I 1 to 16 Total Number of Zones for this Account (Partition)
( _ = Zone Number)
7.18 1Zone# I_?_I 1 to 16 Enter the Zone to Program
7.19 Z+Loc I_0_I_A_I 1st Digit = 0 to 4
2nd Digit = A to H
1st Digit = Device/Zone Address Location
0 = D6112 Onboard Zones
1 to 4 = D630/D640 Zone Expander Address

2nd Digit = Physical Location of Zone on Device
A = “Zone 1” E = “Zone 5” _A = Disabled
B = “Zone 2” F = “Zone 6”
C = “Zone 3” G = “Zone 7”
D = “Zone 4” H = “Zone 8”

7.20 1Zn1 I_ _I_ _I_ _I_ _I_ _I 0 to 9, B to F Enter 5 digit Zone Type, 00000 = Disabled
Typical Zone Programming
Delay Zone N/C (No Trouble or Restoral Reporting, Swinger Shunt) 24130
Delay Zone N/O (No Trouble or Restoral Reporting, Swinger Shunt) 28130
Instant Zone N/C or N/O (No Trouble or Restoral Reporting, Swinger Shunt) 20130
Interior Delay Zone N/C (No Trouble or Restoral Reporting, Swinger Shunt) 14130
Interior Delay Zone N/O (No Trouble or Restoral Reporting, Swinger Shunt) 18130
Interior Instant Zone N/O or N/C (No Trouble or Restoral Reporting, Swinger Shunt) 10130
Glassbreak Zone (No Trouble or Restoral Reporting) 20114
Window Foil Zone (No Trouble or Restoral Reporting) 20114
Fire Zone (Trouble Reporting, no Restoral Reporting) 01414
Audible Panic N/C or N/O (No Trouble or Restoral Reporting, Invisible Zone) 00111
Silent Panic N/C or N/O (No Trouble or Restoral Reporting, Invisible Zone) 00011
Independent Zone Control (If D268, D269 and D279 Expander Module is Used) 01150
Digit 1 = Zone Response
0 = 24Hr Zone
1 = Interior Zone
2 = Perimeter Zone
3 = Priority 24Hr Zone
4 = Priority Interior Zone
5 = Priority Perimeter Zone
(Priority Zns can’t be Bypassed or Forced)

Digit 2 = Zone Response to Open or Short
0 = No Trouble, No Delay, Instant on Open or Short
1 = Trouble on Open, Instant on Open or Short
2 = Trouble on Short, Instant on Open or Short
3 = Trouble on Open or Short, Instant on Open or Short
4 = Delay on Open, Instant on Short, No Troubles
5 = Delay on Open, Instant on Short, Trouble on Open
6 = Delay on Open, Trouble on Short, Instant on Short
7 = Delay on Open, Trouble on Open/Short, instant on Short
8 = Delay on Short, Instant on Open, No Troubles
9 = Delay on Short, Instant on Open, Trouble on Open
A = Delay on Short, Instant on Open, Trouble on Short
B = Delay on Short, Instant on Open, Trouble on Open/Short
C = Delay on Open or Short, No Troubles
D = Delay on Open or Short, Trouble on Open
E = Delay on Open or Short, Trouble on Short
F = Delay on Open or Short, Trouble on Open/Short

Digit 3 = Zone Local Alarm Response
0 = Silent Alarm, No Alarm Output
1 = Steady Alarm Output for Bells/Sirens
2 = Aux Relay Activation for Bell Timeout
3 = Aux Relay Activation/Steady Alarm Output
4 = Pulsing Alarm Output for Bells/Sirens
5 = Aux Relay Activation
6 = Aux Relay Activation, Pulsing Alarm Output

Digit 4 = Central Station Reporting Options
0 = Non-Reporting, Local Zone Only
1 = Standard Reporting Zone
2 = Designated Zone
3 = Swinger Shunt Zone
4 = Swinger Shunt, Designated Zone
5 = Standard Reporting, includes Restorals
6 = Restoral Reports, Designated Zone
7 = Restoral Reports, Swinger Shunt Zone
8 = Restoral Reports, Designated & Swinger

Digit 5 = Local Annunciation Zones & Options
0 = No Options
1 = Invisible Zone (Doesn’t display on Keypad)
2 = Siren until Zone Restoral
3 = Siren until Zone Restoral, Invisible Zone
4 = Sound Buzzer on Fault
5 = Sound Buzzer on Fault, Invisible Zone
6 = Sound Buzzer on Fault, Rings Sirens
7 = Sound Buzzer on Fault, Ring Bell until
Restoral, Invisible Zone

8. Account #2 (Partition 2) Variables/Defaults
8.1 1Acct I_ _I_ _I_ _I_ _I 0 to 9, B to F, Blank Enter 3 digit Account if BFSK or 4/2 used (Virtual)
Enter 4 digit Account if Modem II used (Radionics)
8.2 2Off I_NO_I Yes/No Yes = Disable all Functions except Remote Program
No = Normal operation
8.3 2Local I_NO_I Yes/No Yes = Disable Central Station Reports (Local System)
No = Enable Central Station Reports
8.4 2DlyIn I_30_I 10 to 120, Blank Entry Delay in 10 second increments
8.5 2DlyOut I_60_I 10 to 120, Blank Entry Delay in 10 second increments
8.6 2Prwrn I_YES_I Yes/No Sound Prewarning buzzer during Entry Delay
8.7 2Op/Cl I_NO_I Yes/No Enable Opening/Closing Reports for this Account
8.8 2ReOp I_NO_I Yes/No Enable Restricted Opening Reports (Disarm on Alarm)
8.9 2ReCl I_NO_I Yes/No Enable Restricted Closing Reports
(Send on Force Arm or if Command 0 used to Shunt)
8.10 2CombID I_NO_I Yes/No Identify Opening/Closing Reports by User Passcode
Combination 1 = Zone 1 Combination 5 = Zone 5
Combination 2 = Zone 2 Combination 6 = Zone 6
Combination 3 = Zone 3 Combination 7 = Zone 7
Combination 4 = Zone 4     Download or CMD 1 Arming = Zone 9
8.11 2CnclRpt I_NO_I Yes/No Enable Cancel Reports for this Account
8.12 2Duress I_NO_I Yes/No Enable Duress Reports for this Account
(Duress = 1 digit above User Passcode)
8.13 2DlyRes I_NO_I Yes/No Delay Restoral Reports until Bell Timeout
8.14 2Ring1 I_YES_I Yes/No 1 Alarm Output per Zone (Swinger Shutdown)
8.15 2TsBell I_NO_I Yes/No Automatic Bell Test after Arming
8.16 2Show I_YES_I Yes/No Show Zone Status while Disarmed
8.17 Acct2Zns I_8_I 1 to 16 Total Number of Zones for this Account (Partition)
( _ = Zone Number)
8.18 2Zone# I_?_I 1 to 16 Enter the Zone to Program
8.19 2Z_Loc I_0_I_A_I 1st Digit = 0 to 4
2nd Digit = A to H
1st Digit = Device/Zone Address Location
0 = D6112 Onboard Zones
1 to 4 = D630/D640 Zone Expander Address

2nd Digit = Physical Location of Zone on Device
A = “Zone 1” E = “Zone 5” _A = Disabled
B = “Zone 2” F = “Zone 6”
C = “Zone 3” G = “Zone 7”
D = “Zone 4” H = “Zone 8”

8.20 1Zn_ I_ _I_ _I_ _I_ _I_ _I 0 to 9, B to F Enter 5 digit Zone Type, 00000 = Disabled
(See Zone 1 Programming)
9. Test Timer Variables/Defaults
9.1 TsPPh I_NO_I Yes/No Transmit Auto-Test Report to Primary Phone
9.2 TsAPh I_NO_I Yes/No Transmit Auto-Test Report to Alternate Phone
9.3 Days I_YES_I Yes/No Yes = Interval in Days, No = Interval in Hours
9.4 Intvl I_0_I 0 to 63 Automatic Test Time Interval Days or Hours
9.5 DysRpt I_0_I 0 to 63 Number of Days until first Automatic Test Report
9.6 HrsRpt I_0_I 0 to 63 Number of Hours until first Automatic Test Report
9.7 TsCode I_ _I 0 to 9, Blank
0 to 9, B to F, Blank
(BFSK or Pulse Format) Automatic Test Code
(Modem II Format)
9.8 TsE I_NO_I Yes/No Transmit Restoral Code E at Auto Test Report Time
9.9 TsDef I_NO_I Yes/No Defer Test Report when System Report Generated