1. |
Account |
|
Account # |
I_ _I_ _I_ _I_ _I |
(0 to 9, B to F) |
|
(Virtual Receiver use 0 + 3-digit account number, for Radionics Receiver use 4-digit account) |
|
Disable Sys |
I_NO_I |
No = Not Disabled, Yes = System shut down |
|
Local |
I_NO_I |
No = Reporting, Yes = No Reporting |
|
Entry Delay |
I_0_I_3_I_0_I |
10 to 120 seconds, Blank = No Entry Delay |
|
BuzzACFail |
I_NO_I |
No = No Buzzer on AC Fail, Yes = Buzzer on AC Fail |
|
Entry Delay |
I_0_I_6_I_0_I |
10 to 120 seconds, Blank = No Entry Delay |
|
Prewarning |
I_YES_I |
No = No Buzzer on Entry Delay, Yes = Buzzer on Entry Delay |
|
Device1Type
Device1Type
|
I_2_I
I_2_I
|
Keypad 1 Type
Keypad 1 Type
|
BLANK = No Device
1 = D611 LED keypad
2 = D420 or D620 LED keypad
3 = D630 or D636 Alpha Keypad
|
2. |
Passcodes |
|
Passcode1 |
I_2_I_3_I_4_I_5_I |
0 to 9 |
|
Passcode2 |
I_ _I_ _I_ _I_ _I |
0 to 9 |
|
Passcode3 |
I_ _I_ _I_ _I_ _I |
0 to 9 |
|
Passcode4 |
I_ _I_ _I_ _I_ _I |
0 to 9 |
|
Passcode5 |
I_ _I_ _I_ _I_ _I |
0 to 9, can be used as Duress if “Duress Type” enabled |
|
User ID |
I_NO_I |
No = Disabled, Yes = Identify O/C Reports by User Passcodes
Passcode1 = Zone 1 |
Passcode4 |
= Zone 4 |
Passcode2 = Zone 2 |
Passcode5 |
= Zone 5 |
Passcode3 = Zone 3 |
RAM or Command 1 = Zone 9 |
|
|
Duress Code |
I_ _I |
0 to 9 if BFSK format
0 to 9, B to F if Modem II format
|
|
Duress Type |
I_PASSCODE + 1_I |
Passcode + 1, Passcode 5 |
|
(To enable Duress User ID must be YES, Opening Report must be C, Closing Report must be C) |
3. |
Phone |
|
PPrefix# |
I_1_I_8_I_0_I_0_I_ _I_ _I_ _I |
8-digits 0 to 9 (Just put 1800)
C = 3 second pause D = 7 second Dial Tone pause
|
|
PPrefix# |
I_?_I_?_I_?_I_?_I_?_I_?_I_?_I |
7-digits 0 to 9 (Rest of phone goes here) |
|
APrefix# |
I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I |
(Alternate Phone, not used) |
|
APrefix# |
I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I |
|
DTMF Dial |
I_YES_I |
No = Pulse Dialing, Yes = DTMF Dialing |
|
CS Format |
I_?_I |
Use 7 if Radionics C Receiver
Use 6 if on Virtual Receiver
|
7 = Radionics Modem Format
6 = Radionics BFSK Format
5 = Radionics Single Round with Parity
4 = Ademco High Speed Double Round
3 = Silent Knight High Speed Double Round
2 = Ademco Low Speed Double Round
1 = Silent Knight Low Speed Double Round
|
|
1400 Hz Ack |
I_NO_I |
No/Yes (Default) |
Always leave at No |
|
2300 Hz Ack |
I_?_I |
No/Yes (Default) |
Yes if using Virtual Receiver
No if using Radionics C Receiver
|
|
AlarmRoute
OP/CL Route
Trouble Route
|
I_1_I
I_0_I
I_1_I
|
Default = 0
Default = 0
Default = 0
|
0 = Primary Phone Only
1 = Primary then Secondary Phone
2 = Alternate then Primary Phone
3 = Primary – Not designated
Secondary – Designated
|
|
Restore Route |
I_0_I |
Default = 0
|
4. |
Remote Program |
|
Passcode |
I_9_I_9_I_9_I_9_I |
4-digits 0 to 9, B to F
Blank = No Remote Access
|
|
AnsArmRings |
I_0_I_5_I |
0 (Default) to 14 Rings
Blank = No Answer
|
|
AnsDisRings |
I_1_I_2_I |
0 (Default) to 14 Ring
Blank = No Answer
|
5. |
Tbl/Restorals |
|
Trouble Code |
I_F_I |
0 to 9, B to F, Blank |
(F is automatic if BFSK or Modem II is used) |
|
Restoral Code |
I_E_I |
0 to 9, B to F, Blank |
(E is automatic if BFSK or Modem II is used) |
|
Expanded T/R |
I_NO_I |
No/Yes (Default) |
(Transmit Expanded Trouble & Restorals) |
|
DelayRestore |
I_NO_I |
No (Default)/Yes |
(Delays Restorals until Siren Timeout)
|
6. |
Open/Closings |
|
Opening Code |
I_ _I |
0 to 9, B to F, Blank |
(B = Default) |
|
Closing Code |
I_ _I |
0 to 9, B to F, Blank |
(C = Default) |
|
Restrict O/C |
I_NO_I |
No (Default)/Yes |
(Open after Alarm, Close if Force Armed) |
|
Cancel Code |
I_ _I |
0 to 9, B to F, Blank |
(Leave Blank)
|
7. |
Bell Options |
|
Bell Time |
I_0_I_6_I |
00 to 63 minutes |
(Default = 06) |
|
Test Bell |
I_NO_I |
No (Default)/Yes |
(Bell Test after Armed) |
|
One Ring |
I_YES_I |
No (Default)/Yes |
(1 alarm per zone during Arming period)
|
8. |
Cmd Options |
|
Cmd1MstrArm |
I_YES_I |
No/Yes (Default) |
(Enable Command 1 Arming (Quick Arm)) |
|
Cmd2InstPer |
I_YES_I |
No/Yes (Default) |
(Enable Command 2 Arming (Instant Arm)) |
|
Cmd3DlyPer |
I_YES_I |
No/Yes (Default) |
(Enable Command 3 Delayed Perimeter Arming) |
|
Cmd5PassChg |
I_YES_I |
No/Yes (Default) |
(Enable Command 5 (Passcode Change Mode) |
|
Cmd6PerWatch |
I_YES_I |
No/Yes (Default) |
(Enables Command 6 (Door Chime Mode) |
|
Cmd8PerPartl |
I_YES_I |
No/Yes (Default) |
(Enable Command 8)
(Perimeter Arm with Entry/Exit Delay)
(Partial Arming by bypassing open zones)
|
|
Cmd0ZnBypass |
I_YES_I |
No/Yes (Default) |
(Force Arm with Passcode & Command 1, 2, 3) |
|
Force Arming |
I_YES_I |
No/Yes (Default) |
(Enable Command 0 for Bypass while Arming) |
|
ForceArm Max |
I_1_I |
1 = Default 0 to 6 |
(Maximum Number of Zones for Force Arming)
|
9. |
Sys Test/Reset |
|
Cmd41RstRpt |
I_NO_I |
No (Default)/Yes |
(Enable Command 41 Expanded Restorals) |
|
Cmd42DiagRpt |
I_NO_I |
No/Yes (Default) |
(Enable Command 41 Expanded Restorals) |
|
Cmd44SysTst |
I_NO_I |
No/Yes (Default) |
(Enable Command 44 to send Test signal)
(if No will also disable “A” Function key)
|
|
Cmd47SmkRst |
I_YES_I |
No/Yes (Default) |
(Enable Command 47 to reset smoke detectors)
(if No will also disable “B” Function key)
|
|
Battery Supv |
I_9_I |
0 to 9, B to F, Blank |
(Enables Low Battery Reports)
(9 = Trouble & Restore Zone 9)
|
10. |
Special Cmds (Command 7 and 9 are) |
|
Cmd7RptCode |
I_7_I |
0 to 9, B to F, Blank |
(Command 7 Alarm Report Code) |
|
Cmd7Bell |
I_NO_I |
No (Default)/Yes |
(No Siren/Bell on Command 7 Medical Alarm) |
|
Cmd7PlsBell |
I_NO_I |
No (Default)/Yes |
(No Pulsed Siren/Bell on Command 7 Medical Alarm) |
|
Cmd7AltAlrm |
I_NO_I |
No (Default)/Yes |
(No Alternate Alarm on Command 7 Medical Alarm) |
|
Cmd9RptCode |
I_9_I |
0 to 9, B to F, Blank |
(Command 9 Alarm Report Code) |
|
Cmd9Bell |
I_YES_I |
No (Default)/Yes |
(Enable Siren/Bell on Command 9 Fire Alarm) |
|
Cmd9PlsBell |
I_YES_I |
No (Default)/Yes |
(Enable Pulsed Siren/Bell on Command 9 Fire Alarm) |
|
Cmd9AltAlrm |
I_NO_I |
No (Default)/Yes |
(Activate Alternate Alarm on Command 9 Fire Alarm)
|
11. |
Zone Codes |
|
Show Zones |
I_YES_I |
No/Yes (Default) |
(Shows Zone Status while Disarmed) |
|
|
Default |
|
Default Zone Type (00000 if Zone not used) |
|
Zone1 Code |
I_0_I_1_I_4_I_5_I_4_I |
Fire, Trouble and Restorals |
|
Zone2 Code |
I_2_I_6_I_1_I_5_I_0_I |
Perimeter Delay, Trouble and Restorals |
|
Zone3 Code |
I_2_I_2_I_1_I_5_I_0_I |
Perimeter Instant, Trouble and Restorals |
|
Zone4 Code |
I_2_I_2_I_1_I_5_I_0_I |
Perimeter Instant, Trouble and Restorals |
|
Zone5 Code |
I_2_I_2_I_1_I_5_I_0_I |
Perimeter Instant, Trouble and Restorals |
|
Zone6 Code |
I_1_I_2_I_1_I_5_I_0_I |
Interior Instant, Trouble and Restorals |
|
|
Digit 1 = Zone Type
0 = 24 Hour Zone
1 = Interior Zone
2 = Perimeter Zone
3 = Priority 24 Hour Zone
4 = Priority Interior Zone
5 = Priority Perimeter Zone
|
Digit 2 = Response to Open or Short
0 = No Trouble, No Delay, Instant Alarm on Open or Short
1 = Trouble on Open, Instant Alarm on Open or Short
2 = Trouble on Short, Instant Alarm on Open or Short
3 = Trouble on Open or Short, Instant Alarm on Open or Short
4 = Delay on Open, Instant Alarm on Short, no Trouble Conditions
5 = Delay on Open, Instant Alarm on Short, Trouble on Open
6 = Delay on Open, Trouble on Short, Instant Alarm on Short
7 = Delay on Open, Trouble on Open or Short, Instant Alarm on Short
8 = Delay on Short, Instant Alarm on Open, no Trouble Conditions
9 = Delay on Short, Instant Alarm on Open, Trouble on Open
A = Delay on Short, Instant Alarm on Open, Trouble on Open
B = Delay on Short, Instant Alarm on Open, Trouble on Open or Short
C = Delay on Open or Short, no Trouble Conditions
D = Delay on Open or Short, Trouble on Open
E = Delay on Open or Short, Trouble on Short
F = Delay on Open or Short, Trouble on Open or Short
|
Digit 3 = Zone Alarm Local Response
0 = Silent Alarm, No Alarm Output
1 = Steady Alarm Output for Bells/Sirens
2 = Alternate Alarm Output Activation for Duration of Bell Timeout
3 = Alternate Alarm Output Activation and Steady Alarm Output for Bells/Sirens
4 = Pulsing Alarm Output for Bells/Sirens (Overrides single Bell per fault option)
5 = Alternate Alarm Output Activation (Overrides single Bell per fault option)
6 = Alternate Alarm Output Activation and Pulsing Alarm Output for Bells/Sirens
|
Digit 4 = Central Station Reporting Options
0 = Non-Reporting, Local Zone only
1 = Standard Reporting Zone
2 = Designated Zone
3 = Swinger Shunt Zone
4 = Swinger Shunt, Designated Zone
5 = Standard Reporting Zone, Includes Restoral Reports
6 = Restoral Reports, Designated Zone
7 = Restoral Reports, Swinger Shunt zone
8 = Designated Zone
|
Digit 5 = Local Zone Annunciation and Options
0 = No Options
1 = Invisible Zone
2 = Ring Siren/Bells until Zone Restoral
3 = Ring Siren/Bells until Zone Restoral, Invisible Zone
4 = Sound Buzzers for Zone Fault
5 = Sound Buzzers for Zone Fault, Invisible Zone
6 = Sound Buzzers for Zone Fault, ring Siren/Bells until Zone Restoral
7 = Sound Buzzers for Zone Fault, ring Siren/Bells until Zone Restoral, Invisible Zone
|
|
12. |
Test Reports |
|
TestPrimary |
I_NO_I |
No/Yes (Default) |
(Transmit Test Reports to Primary Phone) |
|
TestAlternate |
I_NO_I |
No (Default)/Yes |
(Transmit Test Reports to Alternate Phone) |
|
Test Code |
I_ _I_ _I |
0 to 9 if BFSK format |
(Test Report Code, Blank = disabled)
0 to 9, B to F if Modem II format
|
|
Test Code E |
I_NO_I |
No (Default)/Yes |
(Transmit Automatic Test Report Code) |
|
Interval |
I_1_I |
0 to 63, Default = 1 |
(Test Time in Days) |
|
IntervalDays |
I_YES_I |
No/Yes (Default) |
(No = Test Time in Hours, Yes = In Days) |
|
DaysTilRpt |
I_ _I_ _I |
0 to 63, Default = 1 |
(Number of Days until 1st Test Report) |
|
HoursTilRpt |
I_ _I_ _I |
0 to 63, Default = 1 |
(Number of Hours until 1st Test Report) |
|
Defer Test |
I_NO_I |
No (Default)/Yes |
(Defer Test Reports when an Alarm Generated) |