Bosch Radionics D4112 Program

Programming only by downloading, 5200 Programmer or 5100 “Wand” Programmer
Plug programmer in and momentarily short Reset Pin to Terminal 25 to enable program mode
If C1 to C6 use Modem II Format with 4-digit Account, if Virtual Receiver use BFSK with 3-digit Account

1. Account
Account # I_ _I_ _I_ _I_ _I (0 to 9, B to F)
(Virtual Receiver use 0 + 3-digit account number, for Radionics Receiver use 4-digit account)
Disable Sys I_NO_I No = Not Disabled, Yes = System shut down
Local I_NO_I No = Reporting, Yes = No Reporting
Entry Delay I_0_I_3_I_0_I 10 to 120 seconds, Blank = No Entry Delay
BuzzACFail I_NO_I No = No Buzzer on AC Fail, Yes = Buzzer on AC Fail
Entry Delay I_0_I_6_I_0_I 10 to 120 seconds, Blank = No Entry Delay
Prewarning I_YES_I No = No Buzzer on Entry Delay, Yes = Buzzer on Entry Delay
Device1Type

Device1Type

I_2_I

I_2_I

Keypad 1 Type

Keypad 1 Type

BLANK = No Device
1 = D611 LED keypad
2 = D420 or D620 LED keypad
3 = D630 or D636 Alpha Keypad

2. Passcodes
Passcode1 I_2_I_3_I_4_I_5_I 0 to 9
Passcode2 I_ _I_ _I_ _I_ _I 0 to 9
Passcode3 I_ _I_ _I_ _I_ _I 0 to 9
Passcode4 I_ _I_ _I_ _I_ _I 0 to 9
Passcode5 I_ _I_ _I_ _I_ _I 0 to 9, can be used as Duress if “Duress Type” enabled
User ID I_NO_I No = Disabled, Yes = Identify O/C Reports by User Passcodes

Passcode1 = Zone 1   Passcode4 = Zone 4
Passcode2 = Zone 2 Passcode5 = Zone 5
Passcode3 = Zone 3 RAM or Command 1 = Zone 9
Duress Code I_ _I 0 to 9 if BFSK format
0 to 9, B to F if Modem II format
Duress Type I_PASSCODE + 1_I Passcode + 1, Passcode 5
(To enable Duress User ID must be YES, Opening Report must be C, Closing Report must be C)
3. Phone
PPrefix# I_1_I_8_I_0_I_0_I_ _I_ _I_ _I 8-digits 0 to 9 (Just put 1800)
C = 3 second pause D = 7 second Dial Tone pause
PPrefix# I_?_I_?_I_?_I_?_I_?_I_?_I_?_I 7-digits 0 to 9 (Rest of phone goes here)
APrefix# I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I (Alternate Phone, not used)
APrefix# I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I
DTMF Dial I_YES_I No = Pulse Dialing, Yes = DTMF Dialing
CS Format I_?_I

Use 7 if Radionics C Receiver

Use 6 if on Virtual Receiver

7 = Radionics Modem Format
6 = Radionics BFSK Format
5 = Radionics Single Round with Parity
4 = Ademco High Speed Double Round
3 = Silent Knight High Speed Double Round
2 = Ademco Low Speed Double Round
1 = Silent Knight Low Speed Double Round
1400 Hz Ack I_NO_I No/Yes (Default) Always leave at No
2300 Hz Ack I_?_I No/Yes (Default) Yes if using Virtual Receiver
No if using Radionics C Receiver
AlarmRoute

OP/CL Route

Trouble Route

I_1_I

I_0_I

I_1_I

Default = 0

Default = 0

Default = 0

0 = Primary Phone Only
1 = Primary then Secondary Phone
2 = Alternate then Primary Phone
3 = Primary – Not designated
      Secondary – Designated
Restore Route I_0_I Default = 0

4. Remote Program
Passcode I_9_I_9_I_9_I_9_I 4-digits 0 to 9, B to F
Blank = No Remote Access
AnsArmRings I_0_I_5_I 0 (Default) to 14 Rings
Blank = No Answer
AnsDisRings I_1_I_2_I 0 (Default) to 14 Ring
Blank = No Answer

5. Tbl/Restorals
Trouble Code I_F_I 0 to 9, B to F, Blank (F is automatic if BFSK or Modem II is used)
Restoral Code I_E_I 0 to 9, B to F, Blank (E is automatic if BFSK or Modem II is used)
Expanded T/R I_NO_I No/Yes (Default) (Transmit Expanded Trouble & Restorals)
DelayRestore I_NO_I No (Default)/Yes (Delays Restorals until Siren Timeout)

6. Open/Closings
Opening Code I_ _I 0 to 9, B to F, Blank (B = Default)
Closing Code I_ _I 0 to 9, B to F, Blank (C = Default)
Restrict O/C I_NO_I No (Default)/Yes (Open after Alarm, Close if Force Armed)
Cancel Code I_ _I 0 to 9, B to F, Blank (Leave Blank)

7. Bell Options
Bell Time I_0_I_6_I 00 to 63 minutes (Default = 06)
Test Bell I_NO_I No (Default)/Yes (Bell Test after Armed)
One Ring I_YES_I No (Default)/Yes (1 alarm per zone during Arming period)

8. Cmd Options
Cmd1MstrArm I_YES_I No/Yes (Default) (Enable Command 1 Arming (Quick Arm))
Cmd2InstPer I_YES_I No/Yes (Default) (Enable Command 2 Arming (Instant Arm))
Cmd3DlyPer I_YES_I No/Yes (Default) (Enable Command 3 Delayed Perimeter Arming)
Cmd5PassChg I_YES_I No/Yes (Default) (Enable Command 5 (Passcode Change Mode)
Cmd6PerWatch I_YES_I No/Yes (Default) (Enables Command 6 (Door Chime Mode)
Cmd8PerPartl I_YES_I No/Yes (Default) (Enable Command 8)
(Perimeter Arm with Entry/Exit Delay)
(Partial Arming by bypassing open zones)
Cmd0ZnBypass I_YES_I No/Yes (Default) (Force Arm with Passcode & Command 1, 2, 3)
Force Arming I_YES_I No/Yes (Default) (Enable Command 0 for Bypass while Arming)
ForceArm Max I_1_I 1 = Default 0 to 6 (Maximum Number of Zones for Force Arming)

9. Sys Test/Reset
Cmd41RstRpt I_NO_I No (Default)/Yes (Enable Command 41 Expanded Restorals)
Cmd42DiagRpt I_NO_I No/Yes (Default) (Enable Command 41 Expanded Restorals)
Cmd44SysTst I_NO_I No/Yes (Default) (Enable Command 44 to send Test signal)
(if No will also disable “A” Function key)
Cmd47SmkRst I_YES_I No/Yes (Default) (Enable Command 47 to reset smoke detectors)
(if No will also disable “B” Function key)
Battery Supv I_9_I 0 to 9, B to F, Blank (Enables Low Battery Reports)
(9 = Trouble & Restore Zone 9)

10. Special Cmds (Command 7 and 9 are)
Cmd7RptCode I_7_I 0 to 9, B to F, Blank (Command 7 Alarm Report Code)
Cmd7Bell I_NO_I No (Default)/Yes (No Siren/Bell on Command 7 Medical Alarm)
Cmd7PlsBell I_NO_I No (Default)/Yes (No Pulsed Siren/Bell on Command 7 Medical Alarm)
Cmd7AltAlrm I_NO_I No (Default)/Yes (No Alternate Alarm on Command 7 Medical Alarm)
Cmd9RptCode I_9_I 0 to 9, B to F, Blank (Command 9 Alarm Report Code)
Cmd9Bell I_YES_I No (Default)/Yes (Enable Siren/Bell on Command 9 Fire Alarm)
Cmd9PlsBell I_YES_I No (Default)/Yes (Enable Pulsed Siren/Bell on Command 9 Fire Alarm)
Cmd9AltAlrm I_NO_I No (Default)/Yes (Activate Alternate Alarm on Command 9 Fire Alarm)

11. Zone Codes
Show Zones I_YES_I No/Yes (Default) (Shows Zone Status while Disarmed)
Default Default Zone Type (00000 if Zone not used)
Zone1 Code I_0_I_1_I_4_I_5_I_4_I Fire, Trouble and Restorals
Zone2 Code I_2_I_6_I_1_I_5_I_0_I Perimeter Delay, Trouble and Restorals
Zone3 Code I_2_I_2_I_1_I_5_I_0_I Perimeter Instant, Trouble and Restorals
Zone4 Code I_2_I_2_I_1_I_5_I_0_I Perimeter Instant, Trouble and Restorals
Zone5 Code I_2_I_2_I_1_I_5_I_0_I Perimeter Instant, Trouble and Restorals
Zone6 Code I_1_I_2_I_1_I_5_I_0_I Interior Instant, Trouble and Restorals
Digit 1 = Zone Type
0 = 24 Hour Zone
1 = Interior Zone
2 = Perimeter Zone
3 = Priority 24 Hour Zone
4 = Priority Interior Zone
5 = Priority Perimeter Zone

Digit 2 = Response to Open or Short
0 = No Trouble, No Delay, Instant Alarm on Open or Short
1 = Trouble on Open, Instant Alarm on Open or Short
2 = Trouble on Short, Instant Alarm on Open or Short
3 = Trouble on Open or Short, Instant Alarm on Open or Short
4 = Delay on Open, Instant Alarm on Short, no Trouble Conditions
5 = Delay on Open, Instant Alarm on Short, Trouble on Open
6 = Delay on Open, Trouble on Short, Instant Alarm on Short
7 = Delay on Open, Trouble on Open or Short, Instant Alarm on Short
8 = Delay on Short, Instant Alarm on Open, no Trouble Conditions
9 = Delay on Short, Instant Alarm on Open, Trouble on Open
A = Delay on Short, Instant Alarm on Open, Trouble on Open
B = Delay on Short, Instant Alarm on Open, Trouble on Open or Short
C = Delay on Open or Short, no Trouble Conditions
D = Delay on Open or Short, Trouble on Open
E = Delay on Open or Short, Trouble on Short
F = Delay on Open or Short, Trouble on Open or Short

Digit 3 = Zone Alarm Local Response
0 = Silent Alarm, No Alarm Output
1 = Steady Alarm Output for Bells/Sirens
2 = Alternate Alarm Output Activation for Duration of Bell Timeout
3 = Alternate Alarm Output Activation and Steady Alarm Output for Bells/Sirens
4 = Pulsing Alarm Output for Bells/Sirens (Overrides single Bell per fault option)
5 = Alternate Alarm Output Activation (Overrides single Bell per fault option)
6 = Alternate Alarm Output Activation and Pulsing Alarm Output for Bells/Sirens

Digit 4 = Central Station Reporting Options
0 = Non-Reporting, Local Zone only
1 = Standard Reporting Zone
2 = Designated Zone
3 = Swinger Shunt Zone
4 = Swinger Shunt, Designated Zone
5 = Standard Reporting Zone, Includes Restoral Reports
6 = Restoral Reports, Designated Zone
7 = Restoral Reports, Swinger Shunt zone
8 = Designated Zone

Digit 5 = Local Zone Annunciation and Options
0 = No Options
1 = Invisible Zone
2 = Ring Siren/Bells until Zone Restoral
3 = Ring Siren/Bells until Zone Restoral, Invisible Zone
4 = Sound Buzzers for Zone Fault
5 = Sound Buzzers for Zone Fault, Invisible Zone
6 = Sound Buzzers for Zone Fault, ring Siren/Bells until Zone Restoral
7 = Sound Buzzers for Zone Fault, ring Siren/Bells until Zone Restoral, Invisible Zone

12. Test Reports
TestPrimary I_NO_I No/Yes (Default) (Transmit Test Reports to Primary Phone)
TestAlternate I_NO_I No (Default)/Yes (Transmit Test Reports to Alternate Phone)
Test Code I_ _I_ _I 0 to 9 if BFSK format (Test Report Code, Blank = disabled)
0 to 9, B to F if Modem II format
Test Code E I_NO_I No (Default)/Yes (Transmit Automatic Test Report Code)
Interval I_1_I 0 to 63, Default = 1 (Test Time in Days)
IntervalDays I_YES_I No/Yes (Default) (No = Test Time in Hours, Yes = In Days)
DaysTilRpt I_ _I_ _I 0 to 63, Default = 1 (Number of Days until 1st Test Report)
HoursTilRpt I_ _I_ _I 0 to 63, Default = 1 (Number of Hours until 1st Test Report)
Defer Test I_NO_I No (Default)/Yes (Defer Test Reports when an Alarm Generated)