1. |
|
System Configuration |
|
1 |
Account Number |
(4-digits) |
0 to 9 / B to F |
|
2 |
Swinger Count |
3 |
1 = 1 Alarm before bypass
2 = 2 Alarms before bypass
3 = 3 Alarms before bypass
4 = 4 Alarms before bypass
|
|
3 |
Keyswitch |
0 |
0 = Momentary
1 = Easikey
|
|
4 |
Custom Idle Text |
RADIONICS |
|
5 |
Custom Idle Text |
D2212 |
|
6 |
Custom Service Text |
(Blank)
|
2. |
|
Phone |
|
|
1 |
DTMF Dialing |
1 = Yes |
0 = No
1 = Yes
|
|
2 |
Phone 1 |
(19 digits) |
0 to 9 / # / *
C = 3 second pause
|
|
3 |
Phone 2 |
(Leave Blank) |
D = 7 second dial tone wait |
|
4 |
Phone Routing |
1 = Yes |
0 = No
1 = Yes
|
|
|
(Yes enables below routing options)
|
5 |
Fire Route |
1 = Phone 1 Only |
0 = Local
1 = Phone 1
|
|
6 |
Non-Fire Route (Burg) |
1 = Phone 1 Only |
2 = Phone 2
3 = Both
|
|
7 |
Point Trouble Route |
1 = Phone 1 Only |
|
8 |
Restoral Route |
0 = Local |
|
9 |
Closing Route |
0 = Local |
|
10 |
Opening Route |
0 = Local |
|
11 |
Cancel Route |
0 = Local |
|
12 |
System Trouble Route |
1 = Phone 1 Only |
|
13 |
System Restore Route |
0 = Local |
|
14 |
Duress Route |
1 = Phone 1 Only |
|
15 |
Test Route |
1 = Phone 1 Only
|
3. |
|
Reports |
|
1 |
O/C Reports – All On |
0 = No |
0 = No
1 = Yes
|
|
2 |
O/C Reports – Part On |
0 = No |
0 = No
1 = Yes
|
|
3 |
Restricted O/C Reports |
0 = No |
0 = No
1 = Yes
|
|
|
(Opening after Alarm/Closing if Point is bypassed) |
|
4 |
Delay Alarm Report |
0 |
0 to 255 seconds |
|
5 |
Cancel Report |
1 = Yes |
0 = No
1 = Yes
|
|
6 |
Restoral Reports |
0 = No |
0 = No
1 = Yes
2 = Delay
|
|
7 |
AC Fail Buzz/Report |
2 = Buzz, Report |
0 = No Buzz (Keypad), No Report
1 = Buzz, No Report
2 = Buzz Report
3 = Buzz, Tag-Along Report
4 = No Buzz, Report
5 = No Buzz, Tag-Along Report
|
|
8 |
Point User Flag |
0 = No |
1 = Yes
0 = No
|
(Converts Point Numbers to D8112 style ZONEX Format, User ID’s to D8112 style COMEX Format)
|
4. |
|
Receiver |
|
(These are for 4/2 Reporting only) |
|
1 |
Receiver Format |
1 = Modem II |
0 = Pulse (4/2)
1 = Modem II
|
|
2 |
Fire Group |
1 |
1 to 9, B to F |
|
3 |
Non-Fire Group |
3 |
1 to 9, B to F |
|
4 |
Point Trouble Group |
6 |
1 to 9, B to F |
|
5 |
Restoral Group |
0 |
1 to 9, B to F |
|
6 |
Closing Group |
0 |
1 to 9, B to F |
|
7 |
Opening Group |
0 |
1 to 9, B to F |
|
8 |
Cancel Group |
D |
0 to 9, B to F |
|
9 |
System Trouble Group |
7 |
1 (71) Unsuccessful Download Attempt
2 Not Used
3 (73) Automatic Reset
4 Not Used
5 Not Used
6 (76) Report Battery Missing
7 (77) Report Low Battery
8 (78) No AC Power
9 (79) Communication Fail Phone 1
B (7B) Communication Fail Phone 2
C (7C) RF Tamper
D (7D) RF Low Battery
E (7E) RF Receiver 7 Trouble
F (7F) RF Receiver 8 Trouble
|
|
|
This is 1st digit
How it sends is In ( )
|
|
10 |
Sys Restore Group |
8 |
1 (81) Successful Download Attempt
2 Not Used
3 (83) Panel Reset with Stand-By Switch
4 Not Used
5 Not Used
6 Not Used
7 (87) Report Missing & Low Battery Restoral
8 (88) AC Power Restoral
9 (89) Communication Restoral Phone 1
B (8B) Communication Restoral Phone 2
C (8C) RF Tamper Restoral
D (8D) RF Battery Restoral
E (8E) RF Receiver 7 Restoral
F (8F) RF Receiver 8 Restoral
|
|
|
This is 1st digit
How it sends is in ( )
|
|
11 |
Duress Group |
9 |
1 to 3 Not Used
4 (94) 6 Invalid Passcode attempts
5 (95) User Code 8 Duress
|
|
|
How it sends is in ( ) |
|
12 |
Test Group |
0 |
0 Disabled
1 to 5 Not Used
6 Service Stop
7 Service Start
8 Test Report
|
5. |
|
Remote Programming |
|
1 |
RAM Passcode |
999999 |
0 to 9, A to F |
|
2 |
RAM Phone |
(BLANK) |
(19 digits) |
|
3 |
Answer Armed |
0 |
0 to 15 |
|
4 |
Answer Disarmed |
0 |
0 to 15 |
|
5 |
Answering Machine |
1 = Yes |
0 = No
1 = Yes
|
6. |
|
Open/Close |
|
1 |
Entry Delay Time |
30 |
0 to 255 seconds |
|
2 |
Exit Delay Time |
60 |
0 to 255 seconds |
|
3 |
Extended Delay Time |
120 |
0 to 255 seconds |
|
4 |
Exit Tone |
1 = Yes |
0 = No
1 = Yes
|
|
5 |
No Delay |
1 = Part On |
0 = Disabled
1 = Part On
2 = All On
3 = Part and All On
|
|
|
(Enables Part On Arming by pressing 0 twice) |
|
6 |
Excursion |
0 = Disabled |
0 = Disabled
1 = All Step
2 = Part Step
3 = All & Part Step
4 = All Exit
5 = Part Exit
6 = All & Part Exit
|
7. |
|
A B C Keys (Panics) |
|
1 |
A-Key Report (Fire) |
91 |
0 to 9, 00 = Default |
|
2 |
A-Key Alarm Output |
2 |
0 = No Output
1 = Steady Output
2 = Pulsed Output
|
|
3 |
A-Key Ack Tone
(Keypad Ringback after Signal)
|
No |
0 = No
1 = Yes
|
|
4 |
A-Key Text |
“A-Key”
|
|
5 |
B-Key Report (Medical) |
92 |
0 to 9, 00 = Default |
|
6 |
B-Key Alarm Output |
0 |
0 = No Output
1 = Steady Output
2 = Pulsed Output
|
|
7 |
B-Key Ack Tone
(Keypad Ringback after Signal)
|
No |
0 = No
1 = Yes
|
|
8 |
B-Key Text |
“B-Key”
|
|
9 |
C-Key Report (Police) |
93 |
0 to 9, 00 = Default |
|
|
(This report is also sent on activation of * button on Keyfobs) |
|
10 |
C-Key Alarm Output |
1 |
0 = No Output
1 = Steady Output
2 = Pulsed Output
|
|
11 |
C-Key Ack Tone
(Keypad Ringback after Signal)
|
No |
0 = No
1 = Yes
|
|
12 |
C-Key Text |
“C-Key”
|
8. |
|
Bell |
|
1 |
Bell Timer |
6 |
0 to 255 minutes |
|
2 |
Bell Test (if Armed All ON) |
0 = No |
0 = No
1 = Yes
|
|
3 |
Single Ring |
0 = No |
0 = No
1 = Yes
|
|
4 |
Alarm on 2 Fail |
0 = No |
0 = No
1 = Yes
|
|
|
(Siren after 2 failed communication attempts)
|
9. |
|
Test Timer |
|
1 |
Test Interval |
0 = No Report |
0 = No Report
1 = 1 Day
2 = 7 Days
3 = 28 Days
|
|
2 |
Hours To Next (Test) |
0 |
0 to 23 hours |
|
3 |
Minutes to Next (Test) |
0 |
0 to 59 minutes |
|
4 |
Defer Test Report |
0 = No |
0 = No
1 = Yes
|
10. |
|
Address Configuration |
|
1 |
Address 1 |
? |
0 = Not Used |
|
2 |
Address 2 |
? |
1 = LED Keypad (D202A or D220A) |
|
3 |
Address 3 |
? |
2 = Text Keypad (D223) |
|
4 |
Address 4 |
? |
3 = Text Keypad with Points (D222) |
|
5 |
Address 5 |
? |
4 = 8 Point RF Expander (D208) |
|
6 |
Address 6 |
? |
5 = 16 Point RF Expander (D216) |
|
7 |
Address 7 |
? |
6 = Point Expander (D208 Expander) |
|
8 |
Address 1 |
?
|
11. |
|
Point Codes (Zone Configuration) |
|
1 |
Point 1 |
2600A |
(Fire with Verification) |
|
2 |
Point 2 |
8820A |
(Delay) |
|
3 |
Point 3 |
8820A |
(Delay) |
|
4 |
Point 4 |
9820A |
(Instant) |
|
5 |
Point 5 |
7820A |
(Motion) |
|
6 |
Point 6 |
7820A |
(Motion) |
|
7 |
Point 7 |
7820A |
(Motion) |
|
8 |
Point 8 |
7820A |
(Motion)
|
|
Below are used with D208 Expander, D222 Keypad Points or D208RF/D216RF Wireless Receiver |
|
9 |
Point 9 |
0000A |
(Disabled) |
|
10 |
Point 10 |
0000A |
(Disabled) |
|
11 |
Point 11 |
0000A |
(Disabled) |
|
12 |
Point 12 |
0000A |
(Disabled) |
|
13 |
Point 13 |
0000A |
(Disabled) |
|
14 |
Point 14 |
0000A |
(Disabled) |
|
15 |
Point 15 |
0000A |
(Disabled) |
|
16 |
Point 16 |
0000A |
(Disabled) |
|
17 |
Point 17 |
0000A |
(Disabled) |
|
18 |
Point 18 |
0000A |
(Disabled) |
|
19 |
Point 19 |
0000A |
(Disabled) |
|
20 |
Point 20 |
0000A |
(Disabled) |
|
21 |
Point 21 |
0000A |
(Disabled) |
|
22 |
Point 22 |
0000A |
(Disabled) |
|
23 |
Point 23 |
0000A |
(Disabled) |
|
24 |
Point 24 |
0000A |
(Disabled) |
|
|
1st Digit |
= Point Type
0 = Point Disabled |
6 = Delay Zone |
1 = Fire Zone |
7 = Interior Zone |
2 = Fire Zone w/Verification |
8 = Delay Zone |
3 = Buzzer on Fault |
9 = Instant Zone |
4 = 24 Hr Audible/Visible |
A = Keyswitch |
5 = 24 Hr Silent/Invisible |
B = Extended Delay All Arm |
|
C = Extended Delay Part or All Arm |
|
2nd Digit |
= Alarm Response
0 = No Response
1 = Report Enabled
2 = Report Enabled/Alarm Report Delay
3 = Report Enable/Alarm Rep Dellay/Swinger Shutdown
4 = Report Enabled/Swinger Shutdown
5 = Alarm Output
6 = Report Enabled/Alarm Output
7 = Report Enabled/Alarm Report Delay/Alarm Output
8 = Report Enabled/Alarm Report Delay/Swinger Shutdown/Alarm Output
9 = Report Enabled/Swinger Shutdown/Alarm Output
|
3rd Digit |
= Special Point (Zone) Options
0 = Disabled
1 = Trouble on Open
2 = Trouble on Short
3 = Trouble on Open or Short
4 = Double Knock (2 Violations before Alarm)
5 = Trouble on Open/Double Knock
6 = Trouble on Short/Double Knock
7 = Trouble on Open or Short/Double Knock
|
4th Digit |
= Device Address
0 = D2212 On-Board Points
1 = Expansion Device on Address 1
2 = Expansion Device on Address 2
3 = Expansion Device on Address 3
4 = Expansion Device on Address 4
5 = Expansion Device on Address 5
6 = Expansion Device on Address 6
7 = Expansion Device on Address 7 < Use if RF Point
8 = Expansion Device on Address 8 < Use if RF Point
|
5th Digit |
= Sensor Loop (Point Expander Loops only)
A = (Ignored)
B to P = Point Expander Loops labeled B to P
|
|
12. |
|
Point Text (for Text Keypads) |
|
1 |
Point 1 Text |
?????? |
|
2 |
Point 2 Text |
?????? |
|
3 |
Point 3 Text |
?????? |
|
4 |
Point 4 Text |
?????? |
|
5 |
Point 5 Text |
?????? |
|
6 |
Point 6 Text |
?????? |
|
7 |
Point 7 Text |
?????? |
|
8 |
Point 8 Text |
?????? |
|
9 |
Point 9 Text |
?????? |
|
10 |
Point 10 Text |
?????? |
|
11 |
Point 11 Text |
?????? |
|
12 |
Point 12 Text |
?????? |
|
13 |
Point 13 Text |
?????? |
|
14 |
Point 14 Text |
?????? |
|
15 |
Point 15 Text |
?????? |
|
16 |
Point 16 Text |
?????? |
|
17 |
Point 17 Text |
?????? |
|
18 |
Point 18 Text |
?????? |
|
19 |
Point 19 Text |
?????? |
|
20 |
Point 20 Text |
?????? |
|
21 |
Point 21 Text |
?????? |
|
22 |
Point 22 Text |
?????? |
|
23 |
Point 23 Text |
?????? |
|
24 |
Point 24 Text |
??????
|
13. |
|
Relays |
|
1 |
Relay 1 Logic |
0 = Function 1 Only |
0 = Function 1 Only |
|
2 |
Relay 2 Logic |
0 = Function 1 Only |
1 = Function 1 or 2 2 = Function 1 and 2 |
|
3 |
Relay 1 Function 1 |
0 = No Output |
0 = No Output |
|
4 |
Relay 1 Function 2 |
0 = No Output |
1 = Output on Point Alarm
2 = Output on Alarm Memory
|
|
5 |
Relay 2 Function 1 |
0 = No Output |
3 = Output on Point Trouble |
|
6 |
Relay 2 Function 2 |
0 = No Output |
4 = Ouptut on Faulted Follow Point
5 = Output on Watch Tone
6 = Steady Output on A B C Key Activation
7 = Pulsed Output on A B C Key Activation
8 = Momentary Output on A B C Key
9 = 10 Second Output on Disarm
10 = Output follows Alarm Output
11 = Output on All On Arming
12 = Output on Part On Arming
13 = Output on 3 Key Reset
14 = Output on AC Failure
15 = Output on Battery Trouble
16 = Steady Output on Comm Failure
17 = Output while Phone Seizure
18 = Output for 900 ms for Ground Start
19 = Output during Entry/Exit Delay
20 = Output during Extended Delay
21 = Continuous Pulsed Output ←Must use with another function
22 = 2-second Output ← Must use with another function
23 = RF Light Key (on ITI Keyfobs)
24 = 2 second activation for 2-Way Module
|
14. |
|
User Test |
|
1 |
User Bell Test |
Yes |
0 = No
1 = Yes
|
|
2 |
User Battery Test |
Yes |
0 = No
1 = Yes
|
|
3 |
User Comm Test |
Yes |
0 = No
1 = Yes
|
15. |
|
Passcodes |
|
1 |
Installer Code |
654321 |
0 to 9, Blank |
|
2 |
Passcode Length |
? |
3 = 3-digit Passcode
4 = 4-digit Passcode
5 = 5-digit Passcode
6 = 6-digit Passcode
|
|
3 |
Code 8 = Duress |
Yes |
0 = No
1 = Yes
|
|
4 |
Passcode Required |
No |
0 = No
1 = Yes
|
|
5 |
Change Passcode |
Owner |
0 = Disabled
1 = Owner can change Passcode
2 = Owner & User can change Passcode
|
|
|
(On 5200 choose Passcode 1 to 8 then ENTER for below options) |
|
|
User 1 Type
User 1 Passcode
|
Owner
123456
|
Owner / User / One Time
0 to 9, Blank
|
|
|
User 2 Type
User 2 Passcode
|
Disabled
(Blank)
|
Owner / User / One Time
0 to 9, Blank
|
|
|
User 3 Type
User 3 Passcode
|
Disabled
(Blank)
|
Owner / User / One Time
0 to 9, Blank
|
|
|
User 4 Type
User 4 Passcode
|
Disabled
(Blank)
|
Owner / User / One Time
0 to 9, Blank
|
|
|
User 5 Type
User 5 Passcode
|
Disabled
(Blank)
|
Owner / User / One Time
0 to 9, Blank
|
|
|
User 6 Type
User 6 Passcode
|
Disabled
(Blank)
|
Owner / User / One Time
0 to 9, Blank
|
|
|
User 7 Type
User 7 Passcode
|
Disabled
(Blank)
|
Owner / User / One Time
0 to 9, Blank
|
|
|
User 8 Type
User 8 Passcode
|
Disabled
(Blank)
|
Owner / User / One Time
0 to 9, Blank
|
16. |
|
RF Parameters |
|
1 |
Supervision Interval |
24 |
0 = 12 Hours
1 = 24 Hours
|
17. |
|
Program Lock |
|
1 |
Return to Default |
No |
0 = No
1 = Yes
|
|
2 |
Program Lock |
No |
0 = No
1 = Yes
|
|
3 |
Disable System No 0 = No
1 = Yes
|