Zones | 8 on board, up to 67 off board/Expanded |
Wireless | Yes |
Transformer | 16.5 VAC |
Battery | 12 VDC 7/18AH Lead-Acid battery. |
Downloadable | Yes |
Initiate For Download |
Command + 4+ 3 |
Event Log | Yes |
Partitions | 8 |
Panics |
Police – Command 9 Fire – Command 7 (These may be reversed) |
Arm Away | Command + 1 OR Code + ENT |
Arm Stay | Command + 3 |
Area Arm |
1. Press ESC/MENU to enter Keypad Menu. 2. Press NEXT key until the MASTER ARM? function is displayed and press ENT. 3. “MASTER ARM ALL?” is displayed, Press NEXt and it will show “ARM AREA X?” (the X is the first area the code has access to) 4. Press NEXT until the area you want to arm is displayed and press ENt 5. the system may require your passcode enter it and press ENT |
Away Instant | Command + 1 + 1 |
Stay Instant | Command + 2 |
Disarm |
If Enry Delay is active: Enter Code If Entry Delay is not active: Code + ENT |
Silence/Clear Trouble | Code + Esc + Command 4 (This is only temporary, will start beeping again if trouble still exists) |
Reset Sensors | Command 4 + 7 (Trouble or Alarm will return if sensors is still troubled or Faulted) |
Door Chime |
Command + 6 Note: The system does not chime when the Keypad is lit |
Force Arm | Command + 8 (This bypasses all interior zones and any open perimeter zones) |
Bypass | Command + 0 + Zone + ENT + EXIT |
Unbypass | Command + 0 + 0 + Zone + ENTER |
Set Time/Date |
1. Press Command + 4 + 5 and display will show “ENT TIME” 2. Enter the 4 digit time in 12 hour format and press ENT, display will show “AM? 3. If you want AM press ENT for PM press NEXT then ENT, Diplay shows “ENT DATE” 4. Enter Date and press ENT |
Send Test | Command + 4 + 1 |
Change Paritions |
Command + 5 + 0 + Partion + ENT |
Event Log |
1. 9 + 9 + ENT, Display shows “VIEW LOG?” 2. Press ENT and display shows “ENTER START DATE” 3. Press ENT to view the entire log from the newest event OR Enter Date you want to start view from and press ENT 4. Use NEXT and PREV to move about the log and ESC to exit. |