Bosch Radionics 7412 Trouble
CALL FOR SERVICE |
The keypad shows CALL FOR SERVICE when it does not receive data from the control panel. This message can be caused by either a wiring or control panel programming problem. It can also mean that the keypad tamper switch is not fully closed. Service Required |
|
SERVC PANEL | Indicates a problem with the panel. The panel is not operating. Service Required | |
SERVC PARAM | Indicates a problem with the panel. Your panel might not be operating properly. Service Required | |
SERVC AC FAIL |
Indicates that AC power to the security system is interrupted. COMMAND 4 silences the trouble buzz. The display clears when AC power returns. |
|
SERVC BATT LOW |
Indicates the security system’s battery is low, or temporarily draining faster than the system can charge it. |
|
SERVC BATT MSING |
Indicates the security system’s battery is disconnected or shorted. | |
SERVC COMM FAIL |
Failure to Communicate | |
SERVC KEYPAD |
The control panel generates this message when it cannot communicate with a supervised keypad. This will show up on Working keypads, keypads without messages are the affected ones. |
|
SERVICE PHONE LINE #1 |
Indicates telephone line trouble on line #1. | |
SERVICE PHONE LINE #2 |
Indicates telephone line trouble on line #2. | |
SERVICE PRINTER |
Local printer (if installed) is in a trouble condition. Ensure the printer is powered on, the paper is correctly is inserted, and the printer is selected. |
|
SERVICE D9210 | One of the D9210 Card Access Control Modules has encountered a problem. Service required | |
BUS TROUBLE | Data Expansion Loop for off-board points faulted | |
BUS RSTOR | Data Expansion Loop for off-board points restored | |
CKSUM FAIL | Panel programming corrupted. Service required | |
CODE TMPR | User made six failed attempts to enter a code at a keypad | |
SDI FAIL | SDI device is not working. Service required | |
WATCHDOG | Panel’s normal CPU operation interrupted and restarted. Service required. | |
POINT TROUBLE | Service Required | |
CHECK DEVICE | A Point Index is programmed with “Display as Device” set to yes. Service required | |
COMM FAIL ROUTE |
The control panel 10 unsuccessful attempts to send a report to the Central Station Receiver. | |
EXTRA POINT 256 |
The D9210B point does not have a point assigned to it. Service required. | |
INVALID POINT | You are trying to bypass a point that is on a differant partition or it does not exist. | |
NO AUTHORITY | Either the function is not turned on or the user passcode is not authorized to perform the function. | |
SERVICE ZONE X |
If the data expansion becomes shorted all POPITs send a shorted condition report and the control panel generates a Pt Bus Trouble. Service required. |
|
SERVC GROUND FAULT |
The control panel has detected a ground fault. Service required. | |
KEYPAD SOUNDS TROUBLE TONE BUT NO TROUBLE SHOWN
|