*06 | – Door Chimes On/Off | (Toggles On/Off) | |||||||||||||||
*07 | – Speaker Volume | (0 = Low, 1 = Medium, 2 = High) | |||||||||||||||
*08 | – 2-Way Audio | (1 = Talk, 2 = Listen, 23 = Hi Listen, 13 = Hi Talk, 9 = Hang Up) | |||||||||||||||
*09 | – Entry Delay 45 | (01 to 60) | |||||||||||||||
*10 | – Exit Delay 45 | (01 to 60) | |||||||||||||||
*19 |
– Identify Sensor Press *19, panel says “Begin Sensor Test” Activate Sensor, panel should beep and identify Zone Wait 45 seconds to exit or enter new command |
||||||||||||||||
*20 |
– Learn Sensor Press * 20 + 2-Digit Zone Number to use (00 to 19) Panel should say “Begin Sensor Test” activate sensor panel beeps, Press # and system should say “OK” |
||||||||||||||||
– Delete Sensor Press *20 + + # + Sensor (00 to 19), Panel says “OFF” | |||||||||||||||||
– Assign Group Press * + Below Sensor Group (*21 to *45) then Sensor Number (00 to 19), panel says “OK” |
|||||||||||||||||
Sensor Groups/Types | |||||||||||||||||
|
|||||||||||||||||
*21 | – Delay Sensor | (Active in Level 2 Stay & Level 3 Away) | |||||||||||||||
*22 | – Instant Sensor | (Active in Level 2 Stay & Level 3 Away) | |||||||||||||||
*23 | – Interior Follower | (Active in Level 3 Away mode) | |||||||||||||||
*24 | – Interior Delay Motion | (Active in Away mode) | |||||||||||||||
*25 | – Delay Windows/Door | (Active in Away mode) | |||||||||||||||
*30 | – 24 Hr Special | (Gun cabinets) (Must bypass to turn Off) | |||||||||||||||
*31 | – 24 Hr Aux. | (Water/Freeze) (Must bypass to turn Off) | |||||||||||||||
*32 | – 24 Hr Special | (Medicine Cabinets) (No Reporting) | |||||||||||||||
*35 | – Fire/Heat Sensor | (Resets if system is disarmed) | |||||||||||||||
*40 | – Keyfob Supervised Audible Panic | (Siren/Help Voice sounds) | |||||||||||||||
*41 | – Keyfob Unsupervised Audible Panic | (Siren/Help Voice sounds) | |||||||||||||||
*42 | – Keyfob Supervised Panic | (No Siren/Audible Help sound) | |||||||||||||||
*43 | – Keyfob Unsupervised Panic | (No Siren/Audible Help sound) | |||||||||||||||
*44 | – Keyfob Supervised Silent Panic | (No Siren/No Audible Help sound) | |||||||||||||||
*45 | – Keyfob Unsupervised Silent Panic | (No Siren/No Audible Help sound) | |||||||||||||||
|
|||||||||||||||||
*60 | – Receiver Number | (Up to 16 digits + # Pause = # within 1st 4 digits) | |||||||||||||||
*61 | – Receiver 2 Number | (Up to 16 digits + #) | |||||||||||||||
*64 | – Account Number | (4 digits) | |||||||||||||||
*65 | – Installer Code | (4 digits (Default is 4321)) | |||||||||||||||
*67 | – 2-Way Audio Enable | (Toggles On/Off) | |||||||||||||||
*87 | – 2-Way Callback Enable | (Toggles On/Off) | |||||||||||||||
*88 | – Remote Answering Enable | (1 = Ring/Hang Ring, 2 = 12 Ring Answer) | |||||||||||||||
*89 | – Battery Test/Panel Tamper | (Toggles On/Off) | |||||||||||||||
*99 | – Exits Programming |