BBC 6000 Basics

The Main Panel is also a speaker on wall, there is no Keypad, system talks
Zones 19 Wireless Sensors
Batteries Main Panel 12 volt 1.2 ah Rechargable
Sensors 3 volt 600mah Lithium “Flat” Lithium DL2430
Police Panic Press Keyfob button (it only has 1 button)
All below commands are entered on any local Telephone
Arm Away Lvl 3 # + User Code + 3 (All Errors sound “OOGA” like an old car)
Arm Stay Lvl 2 # + User Code + 2
Arm Instant Arm in Stay or Away mode, press 5 during Exit Delay
Disarm Level 1 # + User Code + 1 (Also cancels signal to station if in alarm)
Check Status # + *
Bypass
  1. Arm System with sensor open
  2. Enter # + User Code + 6 + 2-digit Sensor Number (01 to 19)
Door Chimes
  1. Enter # + User Code + 0
  2. Press * 06 to Enable/Disable
  3. Press * 99 to exit
Phone Test # + User Code + 8 If Phone Test Fails Panel Status LED stays ON
If Phone Test good system will say “Call Test OK
Sensor Test # + User Code + 9 (Beeps if Sensor opened, exits in 120 seconds)
Volume Control
  1. Enter # + Master Code + 0
  2. Enter *70 for Low Volume
    • *71 for Medium Volume (Default)
    • *72 for High Volume
  3. Press *99 to exit