ATT 8300 Program

Default Panel Move jumper or hold button on board under RF Shield, power down then up
Enter Program 1. Press NEXT until “SECURITY” flashes and press SELECT
2. At “ENTER ACCESS CODE” press # + 6 digit Installer Code (Default = 999999)
3. Display should show “ENTER FUNCTION”
Move to location Enter 3 location then press SELECT, enter data and press SELECT
Next Location AWAY Key
Right Location NIGHT Key
Go to “ENTER FUNCTION” DAY key
Exit Program Press OFF

000 System Tests (normally leave alone) 011 Siren Test 0 = Sirens Off 1 = Siren 1 On 2 = Siren 2 On 012 Relay Test 0 = Relays Off 1 = Relay 1 On 2 = Relay 2 On 013 X-10 Test 0 = Turn Off X-10 Modules
1 = Turn On Modules triggered by Intrusion Alarms
2 = Turn On Modules triggered by Silent Panic Alarms
3 = Turn On Modules triggered by Fire Alarms
4 = Turn On Modules triggered by Emergency Alarms
5 = Turn On Modules triggered by Environmental Alarms
6 = Turn On Modules triggered by Trouble Alarms
7 = Turn On Modules triggered by Auxiliary 1 Alarms
8 = Turn On Modules triggered by Auxiliary 2 Alarms

014 Verify (Sensor) Test Test all devices then select “>” to exit 100 System Settings Loc Description Enter Possible Values 111 Installer Code 999999 Default = 999999 (SELECT saves, AWAY for 112) 112 Remote Code 999999 Default = 999999 (SELECT saves, AWAY for 113) 113 System Report 1 0=Shut Down
1=Enabled
2=Local (SELECT saves, AWAY for 114) 114 Report Type 1 1=Backup
2=Duplicate/Split Report (SELECT saves, AWAY for 115) 115 Adjunct Reporting 1 1=Backup
2=Duplicate (SELECT saves, AWAY for 116) 116 Wireless Enabled ? 0=Disable
1=Enable (SELECT saves, AWAY for 117) (Match House Code with Dip switches on Sensors and with Wireless Receiver)

117 Abbreviated Arming
(Quick Arm) 0 0=Disabled
1= Enabled (SELECT saves, AWAY for 118) 118 Multi-try Lockout 0 0=Disable
1= 4 (SELECT saves, AWAY for 119)
code attempts before
5 minute lockout 119 Keyswitch Arming 3 1=Day
2=Night
3=Away (SELECT saves, AWAY for 120) 120 Assign Keypad
Emergency 1 0=Disable
1=Emergency
2=Fire
3=Environment
4=Aux 1 (SELECT saves, AWAY for 121) 121 Delay Trouble Audible 0000 0000 = Disabled (SELECT saves, AWAY for 122) 122 Short (Entry) Delay 2 0=10 seconds
1=20 seconds
2=30 seconds
3=40 seconds
4=50 seconds
5=60 seconds
6=120 seconds
7=180 seconds
8=240 seconds
9=300 seconds (SELECT saves, AWAY for 123) 123 Long (Exit) Delay 5 (SELECT saves, AWAY for 124) 124 Exit Delay Select 2 0=No Delay
1=Short Delay
2=Long Delay (SELECT saves, AWAY for 125) 125 Phone Enable 1 0=Disable
1=Enable (SELECT saves, AWAY for 126) 126 Intercom Enable 1 0=Disable
1=Enable (SELECT saves, AWAY for 211) 200 Communications 211 Dialing Type 1 0=Pulse
1=Tone (SELECT saves, AWAY for 212) 212 Dialer Delay 0000000 0=No Delay
1=Delay (SELECT saves, AWAY for 213) 213 Dial tone Wait 4 1 to 16 seconds (SELECT saves, AWAY for 214) 214 Interdigit Dialing Delay 1 1=1 second
3=3 seconds (SELECT saves, AWAY for 215) 215 Retry Delay 10 Seconds (SELECT saves, AWAY for 216) 216 Ground Start Enable 0 0=Disable
1=Enable (SELECT saves, AWAY for 217) 217 2-Line Phone Enable
(Dual Dialer Module Req) 0 0=Disable
1=Enable (SELECT saves, AWAY for 218) 218 Phone Test (Hourly) 0 0=Disable
1=Enable (SELECT saves, AWAY for 219) 219 Callback Number 18887753674 (SELECT saves, AWAY for 220)
#=Pause, *70=Call waiting defeat 220 Carrier Delay 3 1 = 10 seconds
3 = 30 seconds
15 = 150 seconds (SELECT saves, AWAY for 221) 221 Ring Count 15 1 to 15 rings (SELECT saves, AWAY for 231) 231 Receiver Phone 1 16 digits (SELECT saves, AWAY for 232)
#=Pause,
*70=Call waiting defeat 232 Account 1 (No letters) 00???? (SELECT saves, AWAY for 233)
Enter 00 then 4-digit account number 233 Receiver 1 Format 3 1 = 3/1 4/1 standard
2 = 3/1 4/1 extended
3 = 4/2
4 = 4/9 (SELECT saves, AWAY for 234)
If using SIA select 3,
if Contact ID use 4 234 Receiver 1 Protocol 8 1 = Slow A 10PPS, 1800hz, 2300 kissoff
2 = Fast A 20 PPS, 1800hz, 2300 kissoff
3 = Slow B 10 PPS, 1900hz, 1400 kissoff
4 = Fast B 20PPS, 1900hz, 1400 kissoff
5 = Superfast 2300 33PPS, 1800hz, 2300 kissoff)
6 = Fast Sumcheck 1400 25PPS, 1800hz, 1400 kiss)
7 = DTMF Dual-Tone (this is NOT Contact ID)
8 = SIA FSK
9 = AT&T FSK 235 Message Codes
Receiver 1 123456789ABCDEF (leave alone) (SELECT saves, AWAY for 236) (Pressing 2, then * or # to scroll digit, then 2 again for next digit then * or # to scroll etc) 1st digit = Perimeter, E/E, 24 Hr, Day Zone Intrusion Alarm
2nd digit = Interior Report
3rd digit = Silent Panic Report
4th digit = Audible Panic Report
5th digit = Fire Alarm Report
6th digit = Keypad Emergency Alarm Report
7th digit = Environmental Alarm Report
8th digit = Trouble Reports
9th digit = Sensor Bypass Restoral Report
10th digit = Sensor Bypass Report
11th digit = Opening Report
12th digit = Closing Report
13th digit = Alarm Cancel Report
14th digit = Trouble Restoral Reports
15th digit = System Reports (Test, Event History Full)

236 Receiver 1 2-way 0 0=Disable
1=Enable (SELECT saves, AWAY for 241) 241 Receiver 2 Phone Number 16 digits (SELECT saves, AWAY for 242) 242 Account 2 (No letters) 6 digits (SELECT saves, AWAY for 243) 243 Receiver 2
Message Format 3 (SELECT saves, AWAY for 244) 244 Receiver 2 Protocol 8 (SELECT saves, AWAY for 245) 245 MSG Report Codes 123456789ABCDEF (leave alone) (SELECT saves, AWAY for 246) 246 Receiver 2 2-way 0 0=Disable
1=Enable (SELECT saves, AWAY for 311) 300 Reporting Options 311 – Auto Test Report Interval 15
0 = Disabled 8 = 15 days
1 = 1 day 9 = 17 days
2 = 3 days 10 = 19 days
3 = 5 days 11 = 21 days
4 = 7 days 13 = 25 days
5 = 9 days 14 = 27 days
6 = 11 days 15 = 29 days
7 = 13 days
312 Test Report Time 2 (2 AM) 1 to 23 (SELECT saves, AWAY for 313) 313 Restoral Report Type 0 0=Disable
1=Enable (SELECT saves, AWAY for 314) 314 Cancel Report Enable 0 0=Disable
1=Enable (SELECT saves, AWAY for 315) 315 AC Power Report 1 0=Disable
1=Enable (SELECT saves, AWAY for 316) 316 Suspended Operation
Report 0 0=Disable
1=Enable (SELECT saves, AWAY for 317) 317 History Report 0 0=Disable
1=Enable (SELECT saves, AWAY for 318) 318 Opening/Closing Report 0 0=Disable
1=Enable (SELECT saves, AWAY for 319) 319 Audible Close Sound 0 0=Disable
1=Enable (SELECT saves, AWAY for 320) 320 Bypass Report Enable 0 0=Disable
1=Enable (SELECT saves, AWAY for 321) 321 Bypass Restoral Report 0 0=Disable
1=Enable (SELECT saves, AWAY for 411) 400 Action Category
Responses (normally just change 411 to enable door chimes) 411 Off Actions
(5 enables chime) 5502245222222002 (SELECT saves, AWAY for 412) 412 Day Actions 1202245222222002 (SELECT saves, AWAY for 413) 413 Night Actions 2222225222222222 (SELECT saves, AWAY for 414) 414 Away Actions 1222225222222122 (SELECT saves, AWAY for 511)
Action
Category
Off Mode
Function 411
Day Mode
Function 412
Night Mode
Function 413
Away Mode
Function 414
Entry/Exit 0 Off 1 Delayed 2 Instant 1 Delayed
Perimeter 0 Off 2 Instant 2 Instant 2 Instant
Interior 0 Off 0 Off 2 Instant 2 Instant
24Hr Perimeter/Tamper 2 Instant 2 Instant 2 Instant 2 Instant
Interior/Tamper 2 Instant 2 Instant 2 Instant 2 Instant
Day Zone 4 Tone 4 Tone 2 Instant 2 Instant
Non-Alarm 5 Chime 5 Chime 5 Chime 5 Chime
Audible Panic 2 Instant 2 Instant 2 Instant 2 Instant
Silent Panic 2 Instant 2 Instant 2 Instant 2 Instant
Fire 2 Instant 2 Instant 2 Instant 2 Instant
Emergency 2 Instant 2 Instant 2 Instant 2 Instant
Environmental 2 Instant 2 Instant 2 Instant 2 Instant
Trouble 2 Instant 2 Instant 2 Instant 2 Instant
Auxiliary 1 0 Off 0 Off 2 Instant 1 Delayed
Auxiliary 2 0 Off 0 Off 2 Instant 2 Instant
Keyswitch 2 Instant 2 Instant 2 Instant 2 Instant
Downloader Info X = No Alarm I = Immediate Alarm T = Warning Tone
D = Delayed Alarm C = Chime F = Follower
500 Sensor Definitions and Reporting
  1. Enter 511 then SELECT
  2. Select Sensor to program then SELECT then press AWAY for sections 512, 513 etc
  3. After completing programming of a sensor you end up at section 611
  4. Press DAY for “Enter Function”, enter 511 again then SELECT
  5. Enter next Sensor number to program then SELECT then AWAY for sections 512, 513 etc
  6. (NIGHT key moves to next zone while in zone programming)
511 Sensor Number ? SELECT saves, AWAY for 512)
(Zones 1 to 16 = Hardwired,
81 to 112 = Wireless) 512 Sensor Description 16 digits (SELECT saves, AWAY for 513)
  1. Press Number key above desired letter (like telephone)
  2. Use * and # to scroll letters up and down
  3. When correct letter is found go back to step 1 for next digit
  4. Press SELECT to finish then AWAY for 513
    • For ‘ press 1 then *
    • To move left press 1 then #
    • For space between words press 0
513 Sensor Type ? (SELECT saves, AWAY for 514)
1 = Entry/Exit
2 = Perimeter
3 = Interior Follower
4 = 24 Hr Zone or Tamper
5 = Interior Tamper
6 = Day Zone
7 = Non Alarm
8 = Audible Panic
9 = Silent Panic
10 = Fire/Smoke
11 = Emergency
12 = Environmental
13 = Trouble Category
14 = Auxiliary 1
15 = Auxiliary 2
16 = Keyswitch
514 Assign Priority ? (0=Non Priority, 1=Priority) (SELECT saves, AWAY for 515) (Priority Zones cannot be bypassed when open, Non-Priority Zones can)

515 Loop Type ? (0=N/C, 1=N/O) (SELECT saves, AWAY for 516) (Hardwired Zones are Normally Closed, Smokes Normally Open, not used for Wireless Zones)

516 Loop Speed ? (0=20ms, 1=400ms) (SELECT saves, AWAY for 517) 517 Zone Supervision ? (0=Disable, 1=Enable) (SELECT saves, AWAY for 518) (1 for regular Wireless,0 for Wireless Panics or Remote keypads)

518 Entry Delay Select ? (0=None, 1=Short, 2=Long) (SELECT saves, AWAY for 519)
(Enable on E/E & Interior Zones) 519 Activate/Deactivate
Sensor ? (0=Not Active, 1=Active) (SELECT saves, AWAY for 520)
(Select Activate to enable a sensor) 520 Assign Bypass Group ? (0=No, 1=Yes) (SELECT saves, AWAY for 521) (Usually not needed unless they like bypassing many zones)

521 Copy Sensor Functions Up to 3 digits (SELECT saves, AWAY for 611) (Copies settings to other sensors, usually just leave it alone)

To program another Sensor press DAY then 511 + SELECT, enter next sensor + SELECT then AWAY etc

600 Bypass Options 611 Bypass Inhibit 0 0=Enable
1=Disable (SELECT saves, AWAY for 612) 612 Enable Force Arming 1 0=Disable
1=Enable (SELECT saves, AWAY for 613) 613 Bypass Restore 0 0=Disable
1=Enable (SELECT saves, AWAY for 614) 614 Swinger Bypass 3 0=Disable
1 to 8=1 to 8 alarms (SELECT saves, AWAY for 615) 615 Permanent Bypassing 1 0=Disable
1=Enable (SELECT saves, AWAY for 616) 616 Bypass Group description 16 digits Leave alone (SELECT saves, AWAY for 711) 700 System Output Settings (Usually leave alone) 711 Fire Cadence (Output) 1 0=Pulsed
1=Continuous (SELECT saves, AWAY for 712) 712 Chime Enable 1 0=Disable
1=Enable (SELECT saves, AWAY for 721) 721 Siren 1 Cadence (Output) 0 0=Pulsed
1=Continuous (SELECT saves, AWAY for 722) 722 Siren 1 Delay 0000000000000000 0=No Delay
1=Delay (SELECT saves, AWAY for 723)
Digit 1 = Entry/Exit Zones
Digit 2 = Perimeter Zones
Digit 3 = Interior Zones
Digit 4 = 23Hr Perimeter Tamper Zones
Digit 5 = Interior Tamper Zones
Digit 6 = Day Zone Zones
Digit 7 = Non-Alarm Zones
Digit 8 = Audible Panic Zones
Digit 9 = Silent Panic Zones
Digit 10 = Fire Zones
Digit 11 = Emergency Zones
Digit 12 = Environmental Zones
Digit 13 = Trouble Category Zones
Digit 14 = Auxiliary 1 Zones (I don’t know what this is yet)
Digit 15 = Auxiliary 2 Zones (I don’t know what this is yet)
Digit 16 = Keyswitch Zones
723 Siren 1 Trigger 1111110101111110 0=No Trigger
1=Trigger (SELECT saves, AWAY for 723)
Digit 1 = Entry/Exit Zones
Digit 2 = Perimeter Zones
Digit 3 = Interior Zones
Digit 4 = 23Hr Perimeter Tamper Zones
Digit 5 = Interior Tamper Zones
Digit 6 = Day Zone Zones
Digit 7 = Non-Alarm Zones
Digit 8 = Audible Panic Zones
Digit 9 = Silent Panic Zones
Digit 10 = Fire Zones
Digit 11 = Emergency Zones
Digit 12 = Environmental Zones
Digit 13 = Trouble Category Zones
Digit 14 = Auxiliary 1 Zones (I don’t know what this is yet)
Digit 15 = Auxiliary 2 Zones (I don’t know what this is yet)
Digit 16 = Keyswitch Zones
724 Siren 2 Cadence 0 0=Pulsed
1=Continuous (SELECT saves, AWAY for 725) 725 Siren 2 Delay 1111111111111111 0=Disable
1=Enable (SELECT saves, AWAY for 726) 726 Siren 2 Trigger 1111110101111110 0=Disable
1=Enable (SELECT saves, AWAY for 727) 727 Alarm Timeout 8 0 to 15 Min (SELECT saves, AWAY for 731) 731 Relay 1 Duration 2 1=6 seconds
2=Until Alarm canx by disarming
3=Until Siren Timeout (SELECT saves, AWAY for 732)
Relays may be used
as Smoke Reset 732 Relay 1 Trigger 1000000000000000 0=No Trigger
1=Trigger (SELECT saves, AWAY for 733)
Digit 1 = Entry/Exit Zones
Digit 2 = Perimeter Zones
Digit 3 = Interior Zones
Digit 4 = 23Hr Perimeter Tamper Zones
Digit 5 = Interior Tamper Zones
Digit 6 = Day Zone Zones
Digit 7 = Non-Alarm Zones
Digit 8 = Audible Panic Zones
Digit 9 = Silent Panic Zones
Digit 10 = Fire Zones
Digit 11 = Emergency Zones
Digit 12 = Environmental Zones
Digit 13 = Trouble Category Zones
Digit 14 = Auxiliary 1 Zones (I don’t know what this is yet)
Digit 15 = Auxiliary 2 Zones (I don’t know what this is yet)
Digit 16 = Keyswitch Zones
733 Additional Relay 1
Triggers 00000000 0=No Trigger
1=Trigger (SELECT saves, AWAY for 734)
Digit 1 = Arming System
Digit 2 = Disarming System
Digit 3 = Bypass Restoral
Digit 4 = Bypassing if Armed
Digit 5 = Openings
Digit 6 = Closings
Digit 7 = Canceling Alarm
Digit 8 = AC Power Failure
734 Relay 2 Duration 2 1=6 seconds
2=Until Alarm canx by Disarm
3=Until Siren Timeout (SELECT saves, AWAY for 735)
Relays may be used as Smoke Reset 735 Relay 2 Trigger 0000000001000000 0=No Trigger
1=Trigger (SELECT saves, AWAY for 736) 736 Additional Relay 2
Triggers 00000000 0=Disable
1=Enable (SELECT saves, AWAY for 741) 741 X-10 House Code ? (SELECT saves, AWAY for 811) (Set X-10 to House Code, Number dial controls how triggered)
1 = Intrusion 1=A 2=B 3=C 4=D
2 = Silent Panic 5=E 6=F 7=G 8=H
3 = Fire 9=I 10=J 11=K 12=L
4 = Emergency 13=M 14=N 15=O 16=P
5 = Environmental
6 = Troubles
7 = Auxiliary 1
8 = Auxiliary 2
800 User Access Codes and Wired Keypad Descriptions

  1. Enter 811 then SELECT
  2. Select User to program then SELECT then press AWAY for sections 812, 813 etc
  3. After completing programming of a User you end up at section 821
  4. Press DAY for “Enter Function”, enter 811 again then SELECT
  5. Enter next User to program then SELECT then AWAY for sections 812, 813 etc
811 User Number (01 = Master) 01 to 15 (SELECT saves, AWAY for 812) 812 User Name ? 6 digits (Skip this, AWAY for 813)
  1. Press Number key above desired letter (like telephone)
  2. Use * and # to scroll letters up and down
  3. When correct letter is found go back to step 1 for next digit
  4. Press SELECT to finish then AWAY for 813
    • For ‘ press 1 then *
    • To move left press 1 then #
    • For space between words press 0
813 User Code 4 digits (SELECT saves, AWAY for 814) 814 User Level 1 (SELECT saves, AWAY for 815) 1 = Highest Authority (Master)
2 = Standard
3 = No clue what this is yet
4 = Lowest level code 815 – User Code Duration 3 0 = 4 hours
1 = 24 hours
2 = 5 days
3 = Permament (SELECT saves, AWAY for 821) Keypad Supervision (leave alone) 821 Wired Keypad Number ? (SELECT saves, AWAY for 822) (Select from 1 to 8, Must match Switches in back of keypad)
(To turn off keypad sounds Dip Switch 4 behind keypad to OFF) 822 Keypad Description (leave alone) 16 characters (SELECT saves)
  1. Press number key above desired letter for 1st letter (look at your telephone)
  2. Use * and # to scroll letters up and down
  3. When correct letter is selected go back to step 1 for next digit
  4. Press SELECT to finish
    • For ‘ press 1 then *
    • to move left press 1 then #
    • to move right press NIGHT
    • For space between words press 0
4/2 Default Report Codes
Entry/Exit Zones 1 + Zone
Perimeter Zones 2 + Zone
Interior Zones 3 + Zone
24Hr Perimeter Tamper Zones 4 + Zone
Interior Tamper Zones 5 + Zone
Day Zone Zones 6 + Zone
Non-Alarm Zones 7 + Zone
Audible Panic Zones 8 + Zone (Keypad Panic sends 48)
Silent Panic Zones 9 + Zone (Keypad Duress sends 31)
Fire Zones + Zone
Emergency Zones (Keypad Medical sends 68)
Environmental Zones
Trouble Category Zones
Auxiliary 1 Zones
Auxiliary 2 Zones
Keyswitch Zones