ATT 8000 Trouble

Reset Trouble (System beeps twice every 40 seconds)
1. Press MESSAGES on Control Panel to display trouble
(NO CHECK IN or LOW BATTERY or AC POWER light show, Zone will display)
2. Press MESSAGES to display other problems or CLEAR DISPLAY to erase
3. Press TEST/DEMO to exit
Silence Trouble Pressing TEST/DEMO silences trouble beeps for 15 hours
Changing
Batteries
1. Enter User Code then OFF at keypad (Panel beeps once, shows – 0 )
2. Press TEST/DEMO for 3 seconds (Display shows – 0 . )
3. Open Sensor cover and replace Battery (Siren may sound but thats OK)
4. Press TEST/DEMO again to exit (Display shows – 0 )
Zone Testing 1. Enter User Code then OFF at keypad (Panel beeps once, shows – 0 )
2. At main panel press TEST/DEMO quickly (Display shows 8. 8. )
3. Quickly press all 4 buttons at same time (Display should show “.C.C”)
4. Activate sensor, beeps indicate signal strength, Display shows Zone

  • 3 Beep – Sensor Okay
  • 2 Beeps – Sensor wireless reception is marginal
  • 0 Beeps – Sensor failure or Sensor Battery is dead

5. Scroll through tested zones with MESSAGES button
6. Exit by pressing TEST/DEMO again (Display shows – 0 )

Smoke Detector LED fash every 7 seconds = Normal
No LED flash = Smoke not functioning
Beeps Rapidly = Low Batteries
Panel Displays
-A Armed Away
-H Armed Home
-0 Off
-0. System is in User Test Mode
– – No State Selected
FI Unidentified Fire Transmitter
AA Disarm Period (Panel is in a 5 minute wait mode)
CC Main Panel Trouble
00 Panel Low Battery
8.8. Installer Test Mode
4/2 Format     Contact ID Signal Is
11 01 Fire
22 02 Medical Panic
33 03 Environmental
44 04 Perimeter
55 05 Interior
66 06 Police Panic
77 07 Holdup/Ambush
88 08 Trouble (This is Generic trouble, could be anything)
67 Cancel
68 Failure Low Battery
71 AC Fail
72 Low Battery
73 Test Battery Test
74 Sup Supervisor
75 Restore
76 Police Panic
79 Medical Panic
95 Fire Panic
96 Medical Panic
99 Police Panic