ATT 8000 Basics
Zones | 32 (0 to 31) all are Wireless |
Batteries | 12 volt rechargeable Gel-Cell in main panel, all sensors are 9-volt Alkaline |
Downloadable | Only to Dialer, NOT to disarm or program User Codes and Zones |
Panic Button | Police, press 2 square keys by ALARM logo on keypad |
Arm Home |
3-digit code + HOME (System beeps once, Panel shows -H) (If 4 beeps one or more zones open) |
Arm Away | 3-digit code + AWAY + OPEN (System beeps once, Panel shows -A) |
Disarm | 3-digit code + OFF (System beeps once, Panel shows -0) |
Silence Alarm | 3 digit code + OFF |
Reset Alarm | Press CLEAR DISPLAY on Main Control Panel |
Reset Trouble | Press TEST/DEMO on Main Control Panel |
Bypass Open |
zone then arm, System will beep 4 times and auto-bypass zone (Bypassed zone will go active again if zone is closed) |
Alarm Memory | Press MESSAGES, last alarm will display, press CLEAR DISPLAY to clear |
Finding Open Zones |
1. Enter User Code then OFF at keypad (Panel beeps once, shows – 0 ) 2. At main panel press TEST/DEMO quickly (Display shows 8. 8. ) 3. Quickly press all 4 buttons at same time (Display should show “.C.C”) 4. Activate sensor, beeps indicate signal strength, Display shows Zone
5. Scroll through tested zones with MESSAGES button |
Reset Smoke |
3-digit code + OFF (If this does NOT reset smoke detector set for service, smoke is bad) |
Panel Displays |
-A = Armed Away -H = Armed Home -0 = Off -0 = System is in User Test Mode – – = No State Selected FI = Unidentified Fire Transmitter AA = System is in 5 minute wait mode after an alarm CC = Main Panel Trouble 00 = Panel Low Battery 8.8. = Installer Test Mode |
Signals |
4/2 Format Contact ID Signal Is 11 01 Fire 22 02 Medical Panic 33 03 Environmental 44 04 Perimeter 55 05 Pir 66 06 Police Panic 77 07 Holdup 88 08 Trouble (This is Generic trouble, could be anything) 67 Cancel 68 Failure Low Battery 71 AC Fail 72 Low Battery 73 Test Battery Test 74 Sup Supervisor 75 Restore 76 Police Panic 79 Medical Panic 95 Fire Panic 96 Medical Panic 99 Police Panic 122 Silent Police Panic 253 Exit Alarm 254 TS = Download Complete |