Aritech Attender 100 Program

Clone of Moose Z1100 System II
Enter Program Press Program button then 0852 (All LED’s will flash)
OR (If Installer Code was changed)
Hold Program Button while powering up (All LED’s will flash)
Move to Location Enter 3-Digit location + #
Entering Data Enter 1 to 3 Digits in location + * to save + # to move to next location
Exit Program Press * twice
Default Panel 1. Hold Program Button while powering up (All LED’s will flash)
2. Press 156 + #
3. Press 1 + ** System exits programming
4. Power down and wait 5 seconds then power up again
Click HERE for how the programming below will report

USER PROGRAMMING

1# User Code 1(Default) I_7_I_7_I_7_I_7_I_ _I 1. Enter location 001 to 008 then #
2. Enter 1 to 5 digit code without * or #
3. System will give long tone and exit
2# User Code 2 I_ _I_ _I_ _I_ _I_ _I
3# User Code 3 I_ _I_ _I_ _I_ _I_ _I
4# User Code 4 I_ _I_ _I_ _I_ _I_ _I (Up to 5 Digits)
5# User Code 5 I_ _I_ _I_ _I_ _I_ _I (Up to 5 Digits)
6# User Code 6 I_ _I_ _I_ _I_ _I_ _I (Up to 5 Digits)
7# User Code 7 I_ _I_ _I_ _I_ _I_ _I (Up to 5 Digits)
8# User Code 8 I_ _I_ _I_ _I_ _I_ _I (Up to 5 Digits)
9# Temp User Code 9 I_ _I_ _I_ _I_ _I_ _I (Up to 5 Digits)
10# User Program Code I_9_I_8_I_8_I_8_I_8_I (Up to 5 Digits)
11# Temp User Code Count I_255*#_I (000 to 255, 255 = Unlimited)
12# Next Comm/Batt Test I_024*#_I (24 Hours)
13# Clear Alarm Memory (No Value Required)
14# Delete User Codes 1 to 9 (Example: 14 # + 5 will delete User Code 5)
15# Not Used

INSTALLER PROGRAMMING STARTS HERE

16# Installer Program Code I_0_I_8_I_5_I_2_I_0_I (Enter 08520, not 0*#, 8*# etc)
17# Exit Delay I_60*#_I Even Numbers = Audible Exit Beeps
Odd Numbers = No Audible Exit Beeps
18# Entry Delay 1 I_30*#_I 1 to 255 seconds
19# Entry Delay 2 I_45*#_I 1 to 255 seconds
20# Not Used
21# Burg Dialer Delay I_0*#_I 0 to 255 Minutes
22# Burg Siren Timeout I_6*#_I 0 = No Cutoff, 1 to 255 Minutes
23# Fire Siren Timeout I_6*#_I 0 = No Cutoff, 1 to 255 Minutes
24# Police Timeout I_6*#_I 0 = No Cutoff, 1 to 255 Minutes
25# Medical Timeout I_6*#_I 0 = No Cutoff, 1 to 255 Minutes
26# Pulsing Burglar Alarm I_0*#_I 0 = Steady Burg Alarm
1 = Pulsing Burg Alarm
27# Pulsing Fire Alarm I_1*#_I 0 = Steady Fire Alarm
1 = Pulsing Fire Alarm
28# Single/Multi Burg Alarm I_0*#_I 0 = Multiple Alarms Permitted
1 = 1 Alarm per Arm/Disarm cycle
29# Keyswitch Mode Change I_1*#_I 0 = Keyswitch cannot change modes
1 = Keyswitch changes Interior/Instant Modes
30# Day Supervisory Latch I_0*#_I 0 = Day Supervisory will not Latch
1 = Day Supervisory conditions latch until Reset (*)
31# Delay on Armed Power-Up I_0*#_I 0 = No Delay on Power-Up
1 = 3 Minute Delay on Power-Up
32# Not Used
33# No Interior Follower I_0*#_I 0 = Interior Follower Enabled
1 = Interior Follower Disabled during Entry Delay Time
34# Siren Test on Arming I_0*#_I 0 = No Siren on Arming
1 = 1 second Burg Alarm Output on Arming (J3 Pin 12)
35# Time Between Bat/Comm Test I_15*#_I
0
1
2
3
4
5
6
7
= 12 Hours
= 1 Day
= 2 Days
= 3 Days
= 4 Days
= 5 Days
= 6 Days
= 7 Days
8
9
10
11
12
13
14
15
= 16 Days
= 18 Days
= 20 Days
= 22 Days
= 24 Days
= 26 Days
= 28 Days
= 30 Days
36# Fast Loop Response I_2*#_I 2 = .08 Seconds
3 = .12 Seconds
8 = .32 Seconds
255 = 10.2 Seconds
37# Slow Loop Response I_8*#_I 2 = .08 Seconds
3 = .12 Seconds
8 = .32 Seconds
255 = 10.2 Seconds
38# Zone 1 Definition I_64*#_I (Below are typical Zone Types)
39# Zone 2 Definition I_72*#_I 64 = Delay
40# Zone 3 Definition I_81*#_I 65 = Instant
41# Zone 4 Definition I_65*#_I 66 = Fire
42# Zone 5 Definition I_65*#_I 72 = Delay 2
43# Zone 6 Definition I_65*#_I 81 = Interior Follower
44# Zone 7 Definition I_65*#_I 03 = Panic buttons
45# Zone 8 Definition I_65*#_I 02 = Medical Panic
46# Zone 1 Supervisory I_0*#_I 0 = Open
1 = Short
47# Zone 2 Supervisory I_0*#_I
48# Zone 3 Supervisory I_0*#_I
49# Zone 4 Supervisory I_0*#_I
50# Zone 5 Supervisory I_0*#_I
51# Zone 6 Supervisory I_0*#_I
52# Zone 7 Supervisory I_0*#_I
53# Zone 8 Supervisory I_0*#_I (If Fire on Zone 8 program as 1)
54# User Code 1 Configuration I_1*#_I 0 = User Code can only use secondary functions
1 = Normal Arm/Disarm Code
8 = Only for Single Zone Arming/Disarming
9 = Duress Code
10 to 15 = May only Arm/Disarm a group of Zones
55# User Code 2 Configuration I_1*#_I
56# User Code 3 Configuration I_1*#_I
57# User Code 4 Configuration I_1*#_I
58# User Code 5 Configuration I_1*#_I
59# User Code 6 Configuration I_1*#_I
60# User Code 7 Configuration I_1*#_I
61# User Code 8 Configuration I_1*#_I
62# User Code 9 Configuration I_9*#_I
63# Single Digit Arming I_0*#_I 0 = User Code Required
1 = Only 1st Digit of User Code req to Arm
64# Not Used
66# Not Used
67# Keypad Police Panic I_0*#_I 0 = Police Panic Enabled
1 = Police Panic Disabled
68# Keypad Medical Panic I_0*#_I 0 = Medical Panic Enabled
1 = Medical Panic Disabled
69# Disable Keypad Bypass I_0*#_I 0 = Bypass Key Enabled
1 = Bypass Key Disabled
70# Silent Keypad on Burg Alarm I_1*#_I 0 = Keypad Audible
1 = Keypad Silent
71# Silent Keypad on Police Panic I_0*#_I 0 = Police Panic Audible
1 = Police Panic Silent
72# Start Entry Delay 1 from Keypad I_0*#_I 0 = Disabled
1 = Start Entry Delay 1 if any key pressed
73# Keypad Home Arming I_0*#_I 0 = Home Key Enabled
1 = Home Key Disabled
74# Disable Keypad Instant Arming I_0*#_I 0 = Instant Key Enabled
1 = Instant Key Disabled
75# Disable Keypad Chime I_0*#_I 0 = Keypad Chime (6 Key) Enabled
1 = Keypad Chime (6 Key) Disabled
76# Disable Battery Test/Fire Reset I_0*#_I 0 = Keypad Reset (7 Key) Enabled
1 = Keypad Reset (7 Key) Disabled
77# Disable Keypad Test Mode I_0*#_I 0 = Keypad Test (8 Key) Enabled
1 = Keypad Test (8 Key) Disabled
78# Communicator Disable/Delay I_1*#_I 0 = Communicator Disabled
1 to 255 = Seconds before Dialing
79# Dial Attempts I_8*#_I 1 to 255 = Communicator Dial Attempts
80# Communicator Alarm Abort I_0*#_I 0 = No Communicator Abort
1 = Abort Communicator on disarm
81# Disable Dialer Test on Power Up I_0*#_I 0 = Communicator Test on Power-Up Enabled
1 = Communicator Test on Power-Up Disabled
82# Opening/System Reports I_0*#_I 0 = All Openings Reported
1 = Opening Report only on Disarm
83# 1st Digit of Account Number I_?*#_I 1 to 9, if 0 in Account use 10
84# 2nd Digit of Account Number I_?*#_I
85# 3rd Digit of Account Number I_?*#_I
86# 4th Digit of Account Number I_?*#_I
87# Communicator Format I_2*#_I
0 = Autobaud (Auto selects handshake from Receiver)
1 = 1400 Hz Handshake, 1900 Hz Data 10 Baud Osborne, Radionics, Silent Knight
2 = 2300 Hz Handshake, 1800 Hz Data 20 Baud DCI, FBII, Franklin, Sescoa
3 = 1400 or 2300 Hz Handshake, 1800 Hz Data 40 Baud Radionics Superfast
4 = 1400 Hz Handshake, 1900 Hz Data, 15 Baud Silent Knight Fast Format
5 = 1400 Hz or 2300 Hz Handshake Radionics BFSK
6 = 1400 Hz Handshake, 1900 Hz Data, 10 Baud Sescoa
7 = 2300 Hz Handshake, 1800 Hz Data, 20 Baud Sescoa
88# Single Round Report I_0*#_I 0 = Disabled
1 = 1 Report per Dialing Attempt
89# 4/2 Reporting Format I_1*#_I 0 = Disabled
1 = Enabled
90# Standard/Extended I_0*#_I 0 = Disabled
1 = Enabled
91# Single Line Extended I_0*#_I 0 = Disabled
1 = Enabled
92# Radionics Parity Checksum I_0*#_I 0 = Disabled
1 = Enabled
93# Touchtone Dialing I_1*#_I 0 = Rotary Dialing
1 = Touch Tone Dialing
94# Zone 1 Report Code (Sends 31) I_3*#_I (0 = Disabled, 1 to 15)
95# Zone 2 Report Code (Sends 32) I_3*#_I (0 = Disabled, 1 to 15)
96# Zone 3 Report Code (Sends 33) I_3*#_I (0 = Disabled, 1 to 15)
97# Zone 4 Report Code (Sends 34) I_3*#_I (0 = Disabled, 1 to 15)
98# Zone 5 Report Code (Sends 35) I_3*#_I (0 = Disabled, 1 to 15)
99# Zone 6 Report Code (Sends 36) I_3*#_I (0 = Disabled, 1 to 15)
100# Zone 7 Report Code (Sends 37) I_3*#_I (0 = Disabled, 1 to 15)
101# Zone 8 Report Code (Sends 38) I_3*#_I (0 = Disabled, 1 to 15)
102# Fire Panic Report Code I_1*#_I (Sends 19, 2nd digit in 165)
103# Police Panic Report Code I_2*#_I (Sends 29, 2nd digit in 165)
104# Medical Panic Report Code I_4*#_I (Sends 49, 2nd digit in 165)
105# Duress Report Code I_2*#_I (Sends 28, 2nd digit is User Number)
106# Open Report Code I_0*#_I (0 = Disabled, 1 to 15, if needed use 5)
107# Close Report Code I_0*#_I (0 = Disabled, 1 to 15, if needed use 6)
108# Bypass/Shunt Report Code I_0*#_I (0 = Disabled, 1 to 15)
109# Cancel Report Code I_0*#_I (0 = Disabled, 1 to 15)
110# Restore Report Code I_0*#_I (0 = Disabled, 1 to 15)
111# Supervisory Report Code I_7*#_I (0 = Disabled, 1 to 15)
112# Low Battery/Fuse Report Code I_7*#_I (2nd Digit in 162, sends 78)
113# Low Battery/Fuse Restore Code I_0*#_I (2nd Digit in 162, Disabled)
114# AC Fail Report Code I_7*#_I (2nd Digit in 161, sends 79)
115# AC Fail Restore I_0*#_I (2nd Digit in 161, Disabled)
116# Memory Error Report Code I_0*#_I (2nd Digit in 163, Disabled)
117# Test Report Code I_0*#_I (2nd Digit in 164, Disabled)
118# to 152# is Telephone 2 Options Do not Program
153# Return to Run Mode (Returns to Normal, Exits programming)
154# Not Programmed
155# Not Programmed
156# Default Panel I_0*#_I 0 = Disabled
1 = Default Panel
157# Listen In Telephone 1 I_0*#_I 0 = Disabled
1 = Listen In Module for Phone 1 Enabled
158# Listen In Telephone 2 I_0*#_I 0 = Disabled
1 = Listen In Module for Phone 2 Enabled
159# Line Seizure Hangup Time I_3*#_I 0 to 255 Seconds
160# Time Between Dial Attempts I_2*#_I 0 to 255 Seconds
161# Extended AC Report Code I_9*#_I (1st Digit in 114, sends 79)
162# Extended Batt/Fuse Report Code I_8*#_I (1st Digit in 112, sends 78)
163# Extended Memory Error I_0*#_I (1st Digit in 116, Disabled)
164# Extended Test Code I_0*#_I (1st Digit in 117, Disabled)
165# Extended Keypad Panic I_9*#_I (1st Digit in 102 to 104)
166# Parity Checksum 0, 1, 2 I_0*#_I 0 = No Parity Checksum
1 = Parity Checksum Enabled
167# Not Programmed
168# Telephone 1 Digit 1 I_1*#_I 11 = *
12 = #
13 = 3 Second Pause
14 = Wait for Dial Tone
15 = Ends Number
169# Telephone 1 Digit 2 I_8*#_I
170# Telephone 1 Digit 3 I_0*#_I
171# Telephone 1 Digit 4 I_0*#_I
172# Telephone 1 Digit 5 I_0*#_I
173# Telephone 1 Digit 6 I_0*#_I
174# Telephone 1 Digit 7 I_0*#_I
175# Telephone 1 Digit 8 I_0*#_I
176# Telephone 1 Digit 9 I_0*#_I
177# Telephone 1 Digit 10 I_0*#_I
178# Telephone 1 Digit 11 I_0*#_I
179# Telephone 1 Digit 12 I_15*#_I
180# Telephone 1 Digit 13 I_15*#_I
181# Telephone 1 Digit 14 I_15*#_I
182# Telephone 1 Digit 15 I_15*#_I
183# Telephone 1 Digit 16 I_15*#_I
184# Telephone 1 Digit 17 I_15*#_I
185# Telephone 1 Digit 18 I_15*#_I
186# Telephone 1 Digit 19 I_15*#_I
187# Telephone 1 Digit 20 I_15*#_I
188# Telephone 1 Digit 21 I_15*#_I
189# Telephone 1 Digit 22 I_15*#_I
190# Telephone 1 Digit 23 I_15*#_I
191# Telephone 1 Digit 24 I_15*#_I
192# Telephone 1 Digit 25 I_15*#_I
193# Telephone 1 Digit 26 I_15*#_I
194# Return to Run Mode (No Value Required)
195# Telephone 2 Digit 1 I_15*#_I 11 = *
12 = #
13 = 3 Second Pause
14 = Wait for Dial Tone
15 = Ends Number
196# Telephone 2 Digit 2 I_15*#_I
197# Telephone 2 Digit 3 I_15*#_I
198# Telephone 2 Digit 4 I_15*#_I
199# Telephone 2 Digit 5 I_15*#_I
200# Telephone 2 Digit 6 I_15*#_I
201# Telephone 2 Digit 7 I_15*#_I
202# Telephone 2 Digit 8 I_15*#_I
203# Telephone 2 Digit 9 I_15*#_I
204# Telephone 2 Digit 10 I_15*#_I
205# Telephone 2 Digit 11 I_15*#_I
206# Telephone 2 Digit 12 I_15*#_I
207# Telephone 2 Digit 13 I_15*#_I
208# Telephone 2 Digit 14 I_15*#_I
209# Telephone 2 Digit 15 I_15*#_I
210# Telephone 2 Digit 16 I_15*#_I
211# Telephone 2 Digit 17 I_15*#_I
212# Telephone 2 Digit 18 I_15*#_I
213# Telephone 2 Digit 19 I_15*#_I
214# Telephone 2 Digit 20 I_15*#_I
215# Telephone 2 Digit 21 I_15*#_I
216# Telephone 2 Digit 22 I_15*#_I
217# Telephone 2 Digit 23 I_15*#_I
218# Telephone 2 Digit 24 I_15*#_I
219# Telephone 2 Digit 25 I_15*#_I
220# Telephone 2 Digit 26 I_15*#_I
221# Missing Keypad Code Phone 1 I_0*#_I 0 = Disabled
222# Missing Keypad Code Phone 2 I_0*#_I 0 = Disabled
223# Extended Missing Keypad Code I_0*#_I 0 = Disabled
224# Communicator Test Timer Init I_0*#_I 0 = No Test Timer Re-initialization
1 = Test Timer Re-initializes after any Report
225# Inhibit Test xmissions I_0*#_I 0 = Test Reports made regardless of Panel Status
1 = Test Reports made only when system is Armed
226# Burg Dial Lockout (Swinger) I_0*#_I 0 = Dialer Lockout Disabled
1 = 1 Burg Alarm Report Per zone per Arm Period
Press * to exit