All wireless is Standard Ademco 5800 sensors, old Apex Wireless cannot be used |
Enter Program |
Press 9173 (Default) |
Enter Data |
Enter 4-digit location + New value |
Clear Location |
4-digit location + A |
Read Location |
4-digit location + H, keypad will speak what is in location |
Exit Program |
9899 keypad will say “Exit Program Mode” |
Defaulting |
Press SW1 until 1 beep defaults Master Code
until 5 beeps defaults Installer Code
until 10 beeps defaults Panel |
|
|
Zone Programming |
|
1. Enter 9940 |
2. “Enter 2-Digit Zone Number” |
(01 to 96) |
3. “Enter 3-Digit Zone Type” |
Exterior Instant |
= 000 |
Silent Panic |
= 008 |
Exterior Delay 1 |
= 001 |
Emergency |
= 009 |
Exterior Delay 2 |
= 002 |
Follower |
= 010 |
Interior Instant |
= 003 |
Aux Type 1 |
= 011 |
Interior Delay 1 |
= 004 |
Aux Type 2 |
= 012 |
Interior Delay 2 |
= 005 |
Day Zone |
= 013 |
Fire |
= 006 |
Step Arming |
= 014 |
Panic |
= 007 |
Button Device Type |
= 015 |
|
Disable Zone |
= 255 |
|
3. “Enter 3-Digit Zone Options 1” |
000 = No Option Below Selected (Default)
016 = Report to Central Station
064 = Display Open at Keypad
080 = Both options
000 = Neither Option |
4. “Enter 3-Digit Zone Option 2” |
000 = No Option Below Selected (Default)
001 = Partition 1
002 = Partition 2
003 = Partition 3
004 = Partition 4 (Add together if needed)
005 = Partition 5
006 = Partition 6
007 = Partition 7
008 = Partition 8
016 = Supress Speech/Beeps for Monitor
032 = Supress OPEN from being Spoken
064 = Supress Siren on Activation |
5. “Enter Enter Device Type” |
V (HARDWIRED) V
000 = 16 Hardwired Zone Input (on Main Board)
001 = 16-Zone Expansion Board
002 = 2-Wire Smoke Loop
021 = Phone Line Monitor
V (WIRELESS) V
025 = 5814 Mini Door Transmitter
003 = 5616 Wireless Door/Window Sensor
004 = 5816 Temp Low Temp Wireless Transmitter
005 = 5817 3-Input Wireless Alarm Transmitter (3 Loop Sensor)
006 = 5818 Recessed Door Wireless Transmitter
007 = 5819 3-Input Shock Wireless Transmitter
024 = 5819WHS Shock Sensor
012 = 5849 Wireless Shock / Glass Detector
011 = 5890 Wireless Motion Transmitter
018 = 5806 Wireless Smoke Detector
019 = 5807 Wireless Smoke Detector
020 = 5808 Smoke Detector
027 = 5809 Smoke Detector
V (BUTTON TYPE) V Each button uses 1 zone
008 = 5801 4-Button Portable Keyfob (Zone Type must be 015)
016 = 5802CP 1-Button Portable Panic (Zone Type must be 015)
009 = 5802MN 1-Button Portable Panic (Zone Type must be 015)
026 = 5802MN2 2-Button Portable Panic (Zone Type must be 015)
010 = 5804 4-Button Keyfob (Zone Type must be 015)
V (ZONE INPUT DEVICES) V
013 = Keypad Alert Activations (Zone Type must be 015)
015 = Local telephone 5 Zero Activation
016 = Loss of Phone Line Activation
017 = 5802CP 1 Button Portable Panic (Zone Type must be 015)
020 = X-10 ON/OFF Command
022 = TS-16 Temperature Sensor |
6. Press F2 if above values are correct, press H to start over |
7. System will ask Loop Number, enter 01 to 16 then press F2
For Hardwired devices enter Loop used on circuit board
For Wireless devices enter Loop used on Transmitter |
8. System will prompt for next Sensor or Serial Number of current device, enter serial from sticker |
9. If wireless Keyfob enter function of key
000 = Speak Time
005 = Speak Status
017 = Step Arming (press button for Stay, again for Away)
018 = Armed to Away
019 = Armed to Home
020 = Disarm
024 = Output Control 1
039 = Output Control 16 |
|
|
System Access Codes |
|
PC Access Code |
Location
Digit 1
Digit 2
Digit 3
Digit 4 |
Default
0495 010 (*)
0496 010 (*)
0497 001
0498 002 |
Program Mode Access Code |
Location
Digit 1
Digit 2
Digit 3
Digit 4 |
Default
0769 009
0770 001
0771 007
0772 003 |
Local Phone Access Code |
Location
Digit 1
Digit 2
Digit 3
Digit 4 |
Default
0784 010 (*)
0785 011 (#)
0786 255 (N/A)
0787 255 (N/A) |
Secured Callback Access Code |
Location
Digit 1
Digit 2
Digit 3
Digit 4 |
Default
0789 002
0790 005
0791 008
0792 000 |
|
|
Downloading Options |
|
Answering Machine Override Digit |
Location
0774 |
Default
011 (#) |
Number of Rings before Answering |
Location
0458 |
Default
010 |
|
|
System Option Automated Programming |
|
|
Locations |
Clear event memory log and long term memory |
9898 |
Enter Phone # for automatic download (From system Keypad only) |
9904 |
Enter Account # for automatic download (From system Keypad only |
9909 |
Speak automatic download Phone # |
9914 |
Speak automatic download account # |
9919 |
Initiate direct connect computer programming |
9952 |
Initiate unattended programming download |
9953 |
Initiate unattended event memory log upload |
9954 |
Speak software revision number |
9990 |
Set time/date (HH-Hour, MM-Minute, W-Day of week, MM-Month, DD-Day, YY-Year) |
9991 |
Set automatic arm/disarm times (Not permitted in a UL installation) |
9993 |
Speak time and date |
9996 |
Set automatic Event Memory Log upload time |
9997 |
|
|
System Options 1 |
|
Options – Enter Total |
Location |
Value |
Automatic time control of remote channels in AWAY mode |
002 |
Disarm before rearm |
|
004 |
Mute external Speaker (ext driver -off, int- adjustable) |
008 |
Access code before arm |
|
016 |
Speak pre-alarm instead of tone |
|
032 |
3 digit disarm code |
|
064 |
Echo system status with 1st digit of a user code |
|
128 |
|
Default |
0130 |
164 |
|
|
System Options 2 |
|
Options – Enter Total |
Location |
Value |
Automatic “force arm” (no second key press) |
|
004 |
No exterior instant exit delay |
|
008 |
No entry delay for Exterior Delay 1 in HOME mode |
016 |
Auto 96 hr clear long term memory and event memory log |
032 |
Zone trouble = zone activation when armed |
064 |
|
Default |
0131 |
000 |
|
|
System Options 3 |
|
Options – Enter Total |
Location |
Value |
Speak time remaining and end of exit delay |
|
001 |
Track activations and record in Long Term Memory |
002 |
Voice driver |
|
004 |
Enable split arming (Not permitted in a UL installation) |
008 |
Echo local phone speech to inside speaker |
|
016 |
Enable night mode |
|
032 |
Enable two-way voice call back (Do not use on a UL install) |
064 |
|
Default |
0132 |
039 |
|
|
System Options 4 |
|
Options – Enter Total |
Location |
Value |
Turn off Pre-alarm System trigger at disarm or alert |
064 |
Suppress Dialer during 2-way callback wait period |
|
128 |
|
Default |
0133 |
000 |
|
|
System Options 5 |
|
Options – Enter Total |
Location |
Value |
Speak auxiliary zone type |
|
001 |
Speak status immediately after local phone access |
|
002 |
Silence inside speaker in Home mode |
|
004 |
Speak zone description in Extended Monitor |
|
008 |
Disable force arming |
|
064 |
|
Default |
0134 |
009 |
|
|
System Options 6 |
|
Options – Enter Total |
Location |
Value |
Speak remote control menu (Do Not do on a UL installation) |
001 |
Speak time and date when time is requested |
|
002 |
Speak temp when time is requested (See “Using a TS-16”) |
004 |
Enable answer service override callback |
|
008 |
|
Default |
0135 |
003 |
|
|
System Times |
|
System Time Options |
Time Increment |
Location |
Default |
Entry delay 1 |
Seconds |
0136 |
020 |
Entry delay 2 |
Seconds |
0137 |
020 |
Exit delay (Not to exceed 60 seconds in a UL installation) |
Seconds |
0138 |
030 |
Alarm cut off and reset |
Minutes |
0139 |
005 |
Duration between fire chirps |
Seconds |
0142 |
000 |
Duration for recognition of AC power loss |
Minutes |
0153 |
001 |
Duration between spoken “Pre-alarm” cycles (000 = 3 seconds) |
Seconds |
0156 |
000 |
Fire siren tone duration before speech |
Seconds |
0158 |
005 |
Burglary siren tone duration before speech |
Seconds |
0159 |
005 |
Fire cut off and reset (Not permitted in a UL installation) |
Minutes |
0157 |
005 |
Number of 4 second samples to determine loss of phone line |
|
0456 |
006 |
Number of activations for swinger shutdown (000 Disables) |
|
0176 |
000 |
Time frame for swinger shutdown to occur |
Hours |
0177 |
024 |
Time frame for “answer after 1st ring” when
answering service override is activated |
Seconds |
0470 |
025 |
|
|
Bypass Options |
|
Option – Enter Total |
Location |
Value |
Open zones automatically bypassed at “force arm” |
|
001 |
Zones bypassed by “force arm” auto unbypassed at disarm |
002 |
Unbypass all bypassed zones automatically at disarm |
|
004 |
|
Default |
0243 |
000 |
|
|
Phone Access Options |
|
Option – Enter Total |
Location |
Default |
Number of rings for pickup (minimum 002, 000 disables) |
0458 |
010 |
Inactivity before auto hang up while user phone access |
0780 |
015 |
Inactivity before auto hang up/exit programming by phone |
0781 |
060 |
|
|
Communicator Programming |
|
|
Location |
Enter Phone #1 (Press H or # twice when finished) |
9900 |
Enter Phone #2 (Press H or # twice when finished) |
9901 |
Enter Account #1 |
9905 |
Enter Account #2 |
9906 |
Speak Phone #1 |
9910 |
Speak Phone #2 |
9911 |
Speak Account #1 |
9915 |
Speak Account #2 |
9916 |
Set Fail to Open/Close times |
9994 |
Set Communicator test times |
9995 |
Echo communicator activity through inside speaker |
9960 |
|
|
Communicator Options |
|
|
Location |
Default |
Delay before dialing after activation Phone #1 (000-disables) |
0437 |
002 |
Delay before dialing after activation Phone #2 (000-disables) |
0438 |
002 |
Off-hook time during listen-in before auto hang-up (000-256 sec) |
0453 |
120 |
Central Station handshake wait period |
0455 |
025 |
Two-way callback from central station wait period |
0461 |
002 |
Voice only and two-way callback wait period for a valid code |
0465 |
060 |
Maximum number of dialing attempts Phone #1 |
0449 |
008 |
Maximum number of dialing attempts Phone #2 |
0450 |
008 |
Touch tone (000) or pulse (001) dialing |
0454 |
000 |
Enable cellular backup (ignore dial tone) (001 – enabled) |
0466 |
000 |
|
|
Reporting Format Enter total Value |
|
Silent Knight Slow |
|
000 |
Silent Knight Fast |
|
001 |
Sescoa Fast (Radionics) |
|
002 |
Multiple Reports / Connection |
|
008 |
Voice Only |
|
032 |
|
|
Location |
Add above |
Phone #1 Default |
0441 |
010 |
Phone #2 Default |
0443 |
010 |
|
|
Reporting Options Enter total Value |
|
3/1 |
|
001 |
4/2 extended w/ zone ID |
|
002 |
4/1/1 |
|
004 |
Ademco Contact-ID (4 digit) |
|
008 |
|
|
Location |
Add Above |
Phone #1 Default |
0442 |
008 |
Phone #2 Default |
0444 |
008 |
|
|
Two-Way Voice Options |
|
Voice Only Options – Enter total |
|
Value |
One Digit Access |
|
016 |
Full User Code Access |
|
032 |
The 0 digit exits to keypad mode |
|
128 |
Two Way Callback Options |
One Digit Access |
|
001 |
Full User Code Access |
|
002 |
The 0 digit exits to keypad mode |
|
008 |
|
|
Location |
Total |
Default |
0464 |
008 |
|
|
Two-Way Digit Assignments |
|
|
Location |
Default |
0 Exit 2-way by going to keypad mode or hanging up |
0223 |
000 |
1 Microphone #1 On |
0224 |
001 |
2 Microphone #2 On |
0225 |
002 |
3 Microphone #3 On |
0226 |
003 |
4 Microphone #1 Off |
0227 |
004 |
5 Microphone #2 Off |
0228 |
005 |
6 Microphone #3 Off |
0229 |
006 |
7 High microphone sensitivity |
0230 |
007 |
8 Normal microphone sensitivity |
0231 |
008 |
9 All microphones on |
0232 |
009 |
* Listen |
0233 |
010 |
# Talk |
0234 |
011 |
Rearrange Keypad phone digits (001 to change from default) |
0222 |
000 |
|
|
Automatic Communicator Testing |
|
Choose to Report Daily, Weekly, or Monthly |
Location |
Value |
Report Daily |
0166 |
000 |
Report Weekly |
|
064 |
Sunday |
|
001 |
Monday |
|
002 |
Tuesday |
|
003 |
Wednesday |
|
004 |
Thursday |
|
005 |
Friday |
|
006 |
Saturday |
|
007 |
Enter Total (Example is Report on every Sunday) |
0166 |
065 |
Report Monthly |
|
128 |
Add the day of the month to use (valid days are 1-31) |
|
001 |
|
Default |
0166 |
129 |
|
|
Report Codes |
|
Dialer Options |
001 |
= Dial Phone 1 |
002 |
= Dial Phone 2 |
004 |
= Enable 2-Way Voice |
008 |
= Dial Alternate Number if 1st choice fails |
128 |
= Record this into Event Memory Log |
|
For 2-way use 133 ??? Add together for value to program into Dialer Options
For no 2-way use 129 |
Report Type |
Location |
Value |
Exterior Instant |
Central Station Report Code
Dialer Option |
0337
0387 |
003
133 |
Exterior Delay 1 |
Central Station Report Code
Dialer Option |
0338
0388 |
003
133 |
Exterior Delay 2 |
Central Station Report Code
Dialer Option |
0339
0389 |
003
133 |
Interior Instant |
Central Station Report Code
Dialer Option |
0340
0390 |
004
133 |
Interior Delay 1 |
Central Station Report Code
Dialer Option |
0341
0391 |
004
133 |
Interior Delay 2 |
Central Station Report Code
Dialer Option |
0342
0392 |
004
133 |
Fire |
Central Station Report Code
Dialer Option |
0343
0393 |
001
133 |
Panic |
Central Station Report Code
Dialer Option |
0344
0394 |
002
133 |
Silent Panic |
Central Station Report Code
Dialer Option |
0345
0395 |
002
133 |
Emergency |
Central Station Report Code
Dialer Option |
0346
0396 |
005
133 |
Follower |
Central Station Report Code
Dialer Option |
0347
0397 |
004
133 |
Auxiliary Zone Type |
Central Station Report Code
Dialer Option |
0348
0398 |
005
133 |
Duress Disarm Silent |
Central Station Report Code
Dialer Option |
0349
0399 |
002
133 |
Duress When Not Armed |
Central Station Report Code
Dialer Option |
0350
0400 |
002
133 |
Zone Restore After Alarm |
Central Station Report Code
Dialer Option |
0351
0401 |
009
129 |
Transmitter Low Battery |
Central Station Report Code
Dialer Option |
0352
0402 |
006
129 |
Transmitter Battery Restore |
Central Station Report Code
Dialer Option |
0353
0403 |
009
129 |
Zone Trouble |
Central Station Report Code
Dialer Option |
0354
0404 |
008
133 |
Zone Trouble Restore |
Central Station Report Code
Dialer Option |
0355
0405 |
009
133 |
High Current Trouble |
Central Station Report Code
Dialer Option |
0356
0406 |
008
133 |
High Current Restore |
Central Station Report Code
Dialer Option |
0357
0407 |
009
129 |
Phone Line Restore |
Central Station Report Code
Dialer Option |
0358
0408 |
009
128 |
Open (Disarm) |
Central Station Report Code
Dialer Option |
0359
0409 |
011
128 |
Open (Disarm) After Alarm |
Central Station Report Code
Dialer Option |
0360
0410 |
011
128 |
Close (Arm) |
Central Station Report Code
Dialer Option |
0361
0411 |
012
128 |
Force Arm |
Central Station Report Code
Dialer Option |
0362
0412 |
012
128 |
Control Low Battery |
Central Station Report Code
Dialer Option |
0363
0413 |
008
129 |
Control Battery Restore |
Central Station Report Code
Dialer Option |
0364
0414 |
009
129 |
AC Fail |
Central Station Report Code
Dialer Option |
0365
0415 |
008
129 |
AC Restore |
Central Station Report Code
Dialer Option |
0366
0416 |
009
128 |
User Communicator Test |
Central Station Report Code
Dialer Option |
0367
0417 |
007
129 |
Auto Communicator Test |
Central Station Report Code
Dialer Option |
0368
0418 |
007
128 |
Cancel |
Central Station Report Code
Dialer Option |
0369
0419 |
000
133 |
Zone Bypass |
Central Station Report Code
Dialer Option |
0370
0420 |
013
128 |
Zone Unbypass |
Central Station Report Code
Dialer Option |
0371
0421 |
014
128 |
Day Zone Trouble |
Central Station Report Code
Dialer Option |
0372
0422 |
008
128 |
Day Zone Trouble Restore |
Central Station Report Code
Dialer Option |
0373
0423 |
009
128 |
Upload/Download Attempt |
Central Station Report Code
Dialer Option |
0374
0424 |
015
129 |
Program Mode Entry |
Central Station Report Code
Dialer Option |
0375
0425 |
015
128 |
Fail to Open |
Central Station Report Code
Dialer Option |
0376
0426 |
011
128 |
Fail to Close |
Central Station Report Code
Dialer Option |
0377
0427 |
012
128 |
Zone Expander Trouble |
Central Station Report Code
Dialer Option |
0378
0428 |
008
128 |
Zone Expander Trble Restore |
Central Station Report Code
Dialer Option |
0379
0429 |
009
128 |
Zone Open |
Central Station Report Code
Dialer Option |
0380
0430 |
000
000 |
Zone Restore |
Central Station Report Code
Dialer Option |
0381
0431 |
000
128 |
Tamper |
Central Station Report Code
Dialer Option |
0382
0432 |
008
128 |
Tamper Restore |
Central Station Report Code
Dialer Option |
0383
0433 |
009
128 |
Receiver Supervision Trouble |
Central Station Report Code
Dialer Option |
0384
0434 |
008
128 |
Receiver Supervision Restore |
Central Station Report Code
Dialer Option |
0385
0435 |
009
128 |
Number of retires when dialing |
|
0246 |
008 |
|
|
Keypad Automated Programming Locations |
|
Option |
Location |
Clear user codes 2-32 |
0000 |
Clear keypad status |
9897 |
Enter Zone / TS16 / Area description |
9920 |
|
Enter remote control channel description |
9921 |
Speak Zone / TS16 / Area description |
9930 |
Speak remote control channel description |
9931 |
Download Words to Keypad |
9965 |
Speak a selected word |
9999 |
|
|
Keypad Option |
|
Option |
Value |
Display time in 24 hour format |
001 |
Default (standard time format |
000 |
|
|
Keypad Area Assignment |
|
Options – |
Enter Total Value |
Area 1 |
001 |
Area 2 |
002 |
Area 3 |
004 |
Area 4 |
008 |
Area 5 |
016 |
Area 6 |
032 |
Area 7 |
064 |
Area 8 |
128 |
Default |
000 |
|
|
User Code + Digit Functions |
|
User Code + Options |
Local phone/Keypads |
Function |
Remote Phone |
Function |
Function for User Code + 1 |
0178 |
000 |
0775 |
015 |
Function for User Code + 2 |
0179 |
001 |
0776 |
001 |
Function for User Code + 3 |
0180 |
013 |
0777 |
013 |
Function for User Code + 4 |
0181 |
014 |
0778 |
014 |
Function for User Code + 5 |
0182 |
004 |
0779 |
005 |
User Code + 6 Smoke Power Reset
User Code + 7 Change User Codes
User Code + 8 Speak Alert Memory
User Code + 9 Bypass Mode
User Code + 0 Communicator Test |
|
|
Extended Monitor Times (seconds) |
|
System Time Options Time Increment |
Location |
Default |
Time extended monitor displayed on keypad (000-continuous) |
0236 |
030 |
Time between speech/beeps w/extended monitor active (000-disable) |
0237 |
005 |
|
|
Zone Types – |
|
Enter Total for Extended Monitor A |
Location |
Value |
Exterior instant |
|
001 |
Exterior delay 1 |
|
002 |
Exterior delay 2 |
|
004 |
Interior instant |
|
008 |
Interior delay 1 |
|
016 |
Interior delay 2 |
|
032 |
Follower |
|
064 |
Auxiliary 1 and 2 |
|
128 |
|
Default |
0238 |
001 |
|
|
Extended Monitor Zone Type Assignment |
|
Enter Total for Extended Monitor B |
Location |
Value |
Exterior instant |
|
001 |
Exterior delay 1 |
|
002 |
Exterior delay 2 |
|
004 |
Interior instant |
|
008 |
Interior delay 1 |
|
016 |
Interior delay 2 |
|
032 |
Follower |
|
064 |
Auxiliary 1 and 2 |
|
128 |
|
Default |
0239 |
007
|
|