Apex Advantage Program

All wireless is old Apex stuff, Ademco 5800 sensors cannot be used
Enter Program Enter 9173 (Default)
Program Location Enter 3-digit location + 3-digit value (keypad speaks new data entered)
Clear Location Enter 3-digit location & press * or A
View Location Enter 3-digit location + # or H, keypad will speak what is in location
Exit Program Press 8 9 9 keypad will say “Exit Program Mode” or wait a few minutes
Defaulting Press SW1
until 1 beep defaults Master Code
until 5 beeps defaults Installer Code
until 10 beeps defaults Panel
Speak Version Enter 990
Not All Options are listed but should be enough to help most tech questions

Zone Programming

Location
166
167
168
Description
Total # of Wireless Zones
Total # of Hardwire Zones
House Code
Default
000 (none)
000 (none)
010 (House Code 10)
(must match Ademco 5700 series wireless sensor dip switches)
Location
001
002
003
004
005
006
007
008
009
010
011
012
013
014
015
016

080

Description
Zone 1 Definitions
Zone 2 Definitions
Zone 3 Definitions
Zone 4 Definitions
Zone 5 Definitions
Zone 6 Definitions
Zone 7 Definitions
Zone 8 Definitions
Zone 9 Definitions
Zone 10 Definitions
Zone 11 Definitions
Zone 12 Definitions
Zone 13 Definitions
Zone 14 Definitions
Zone 15 Definitions
Zone 16 Definitions
to
Zone 80 Definitions
Default
081 (Exterior Delay 1)
082 (Exterior Delay 2)
080 (Exterior Instant)
080 (Exterior Instant)
080 (Exterior Instant)
080 (Exterior Instant)
026 (Interior Follower)
026 (Interior Follower)
015 (Zone Disabled)
015 (Zone Disabled)
015 (Zone Disabled)
015 (Zone Disabled)
015 (Zone Disabled)
015 (Zone Disabled)
015 (Zone Disabled)
015 (Zone Disabled)

015 (Zone Disabled)

Options

015 = Zone Disabled
019 = Interior Instant
020 = Interior Delay 1
021 = Interior Delay 2
024 = 24 Hr Silent Panic
026 = Interior Follower
080 – Exterior Instant
081 = Exterior Delay 1
082 = Exterior Delay 2
085 = 24 Hour Fire
087 = 24 Hour Panic
089 = 24 Hour Medical

for more see page 9 in
the Installation Manual

Note: Hardwire Sensors MUST follow Wireless Sensors in Zone order, so if system has
10 wireless zones the first hardwired zone connected to zone terminal 1 would be zone 11
247 2-Wire Smoke Loop Options 000 (Zone Disabled) Enter 013 to enable
246 Bypass Options 004 (Zones auto-unbypass at disarm)
Note: To enable Force Arming program 007

Zone Voice Programming

To Program

  1. Press 920, keypad will say “Enter Zone” enter 2-digit zone number
  2. Enter 3-digit code for Word Definition, keypad will repeat it
  3. Enter next word, maximum of 4 words, if less than 4 end with H or # key to save and exit
To Hear Descriptions

  1. Press 930, keypad will say “Enter Zone” enter 2-digit zone number
  2. Keypad will speak current Voice Description, end with H or * key

Communicator Programming

Location Description Default Recommend
900 Enter Phone 1 (Press H or # twice when finished)
910 Speak Phone 1
905 Enter Account Number 1 (Press H or # twice when finished)
915 Speak Account Number 1
901 Enter Phone 2 to Central Station (Press H or # twice when finished)
911 Speak Phone 1
906 Enter Account Number 2 (Press H or # twice when finished)
916 Speak Account Number 2
437 Delay before Dialing Phone 1 (seconds) 002 002
438 Delay before Dialing Phone 2 (seconds) 002 002
440 Phone 1 format 000 (3/1) 008 (Contact ID)
442 Phone 2 format 000 (3/1) 008 (Contact ID)
443 Number of Dial Attempts Phone 1 008 008
444 Number of Dial Attempts Phone 2 008 008
960 Echo communicator activity through inside speaker (entering 960 enables/disables)

Downloading/Remote Options

Location Description Default Recommend
521 Answering Machine Over-ride Digit 011 (#) 011
642 Upload/Download Access Code 1st Digit 010 (*) 010
643 Upload/Download Access Code 2nd Digit 010 (*) 010
644 Upload/Download Access Code 3rd Digit 001 001
645 Upload/Download Access Code 4th Digit 002 002
546 Local Phone Access Code 1st Digit ( 1 to 4 digits ) 010 (*) 010
547 Local Phone Access Code 1st Digit ( 1 to 4 digits ) 011 (#) 011
548 Local Phone Access Code 1st Digit ( 1 to 4 digits ) 255 255
549 Local Phone Access Code 1st Digit ( 1 to 4 digits ) 255 255

Installer Code

Location Description Default Recommend
513 1st Digit of Installer Code 009 009
514 2nd Digit of Installer Code 001 001
515 3rd Digit of Installer Code 007 007
516 4th Digit of Installer Code 003 003

User Code Options

Location Description Default Recommend
115 Code 1 Options 250 250
116 Code 2 Options 000 (disabled)
117 Code 3 Options 000 (disabled)
118 Code 4 Options 000 (disabled)
119 Code 5 Options 000 (disabled)
120 Code 6 Options 000 (disabled)
121 Code 7 Options 000 (disabled)
122 Code 8 Options 000 (disabled)
123 Code 9 Options 000 (disabled)
124 Code 10 Options 000 (disabled)
125 Code 11 Options 000 (disabled)
126 Code 12 Options 000 (disabled)
127 Code 13 Options 000 (disabled)
128 Code 14 Options 000 (disabled)
129 Code 15 Options 000 (disabled)
130 Code 16 Options 000 (disabled)
131 Code 17 Options 000 (disabled)
132 Code 18 Options 000 (disabled)
133 Code 19 Options 000 (disabled)
134 Code 20 Options 000 (disabled)

146 Code 32 Duress 000 (disabled) 131 (duress)
000 Clears all Secondary Codes (No Value Required)

System Times

Location Description Default Recommend
100 Entry delay 1 (seconds) 020 030
101 Entry delay 2 (seconds) 020
102 Exit delay (seconds) 030 060
103 Alarm cut off and reset (minutes) 005 006
106 Fire Chirp (time between each chirp in seconds) 000 (disabled)
107 Hardwire Fast Loop Response (x32ms) 002
108 Hardwire Slow Loop Response (x32ms) 005
109 Duration for Voice Recognition of AC loss (minutes) 001 010
110 Time between Control Battery Testing (days) 000

Two-Way Digit Assignments

Location Description Default
222 Rearrange Keypad phone digits (001 changes default) 000
223 0 = Exit 2-way by going to keypad mode or hanging up 000
224 1 = Microphone #1 On 001
225 2 = Microphone #2 On 002
226 3 = Microphone #3 On 003
227 4 = Microphone #1 Off 004 factory
228 5 = Microphone #2 Off 005 Defaults
229 6 = Microphone #3 Off 006 Leave Alone
230 7 = High microphone sensitivity 007
231 8 = Normal microphone sensitivity 008
232 9 = All microphones on 009
233 * = Listen 010
234 # = Talk 011

Report Codes

Dialer Options 001 = Dial Phone 1
002 = Dial Phone 2
004 = Enable 2-Way Voice
008 = Dial Alternate Number if 1st choice fails
128 = Record this into Event Memory Log
??? Add together for value to program into Dialer Options
For 2-way use 133
For no 2-way use 129
Location Description Value
337 Exterior Instant zn Report Code 003
387 Dialer Option 133 (Dial Phone 1, Enable 2-Way)
338 Exterior Delay 1 zn Report Code 003
388 Dialer Option 133 (Dial Phone 1, Enable 2-Way)
339 Exterior Delay 2 zn Report Code 003
389 Dialer Option 133 (Dial Phone 1, Enable 2-Way)
340 Interior Instant zn Report Code 004
390 Dialer Option 133 (Dial Phone 1, Enable 2-Way)
341 Interior Delay 1 zn Report Code 004
391 Dialer Option 133 (Dial Phone 1, Enable 2-Way)
342 Interior Delay 2 zn Report Code 004
392 Dialer Option 133 (Dial Phone 1, Enable 2-Way)
343 Fire zn Report Code 001
393 Dialer Option 133 (Dial Phone 1, Enable 2-Way)
344 Panic Report Code 002
394 Dialer Option 133 (Dial Phone 1, Enable 2-Way)
345 Silent Panic Report Code 002
395 Dialer Option 133 (Dial Phone 1, Enable 2-Way)
346 Emergency Panic Report Code 005
396 Dialer Option 133 (Dial Phone 1, Enable 2-Way)
347 Follower Report Code 004
397 Dialer Option 133 (Dial Phone 1, Enable 2-Way)
348 Aux zn Type 1 & 2 Report Code 005
398 Dialer Option 133 (Dial Phone 1, Enable 2-Way)
349 Duress Disarm Silent Report Code 002
399 Dialer Option 133 (Dial Phone 1, Enable 2-Way)
350 Duress When Not Armed Report Code 002
400 Dialer Option 133 (Dial Phone 1, Enable 2-Way)
351 zn Restore After Activation Report Code 009
401 Dialer Option 129 (Dial Phone 1)
352 Transmitter Low batt Report Code 008
402 Dialer Option 129 (Dial Phone 1)
353 Transmitter Low batt Rest Report Code 009
403 Dialer Option 129 (Dial Phone 1)
354 zn trbl Report Code 008
404 Dialer Option 129 (Dial Phone 1)
355 zn trbl Restore Report Code 009
405 Dialer Option 129 (Dial Phone 1)
356 Blown Fuse Report Code 008
406 Dialer Option 129 (Dial Phone 1)
357 Blown Fuse Restore Report Code 009
407 Dialer Option 129 (Dial Phone 1)
358 Phone Line Restore Report Code 009
408 Dialer Option 129 (Dial Phone 1)
359 Open (Disarm) Report Code 011
409 Dialer Option 129 (Dial Phone 1)
360 Open (Disarm) After Activation Report Code 011
410 Dialer Option 129 (Disabled)
361 Close (Arm) Report Code 012
411 Dialer Option 129 (Dial Phone 1)
362 Close (Arm) with Open zn Report Code 012
412 Dialer Option 129 (Dial Phone 1)
363 Control Low batt Report Code 008
413 Dialer Option 129 (Dial Phone 1)
364 Control Low batt Restore Report Code 009
414 Dialer Option 129 (Disabled)
365 AC Fail Report Code 008
415 Dialer Option 129 (Dial Phone 1)
366 AC Restore Report Code 009
416 Dialer Option 129 (Dial Phone 1)
367 User Communicator Test Report Code 007
417 Dialer Option 129 (Disabled)
368 Auto Communicator Test Report Code 007
418 Dialer Option 129 (Dial Phone 1)
369 Cancel Report Code 000
419 Dialer Option 129 (Dial Phone 1)
370 zn Bypass Report Code 013
420 Dialer Option 129 (Disabled)
371 zn Unbypass Report Code 014
421 Dialer Option 129 (Dial Phone 1)
372 Day zn trbl Report Code 008
422 Dialer Option 129 (Dial Phone 1)
373 Day zn trbl Restore Report Code 009
423 Dialer Option 129 (Disabled)
374 Upload/Download Attempt Report Code 015
424 Dialer Option 129 (Disabled)
375 Program Mode Entry Report Code 015
425 Dialer Option 129 (Dial Phone 1)
376 Fail to Open Report Code 011
426 Dialer Option 129 (Dial Phone 1)
377 Fail to Close Report Code 009
427 Dialer Option 129 (Disabled)
378 LCD-HW Keypad trbl Report Code 008
428 Dialer Option 129 (Disabled)
379 LCD-HW Keypad trbl Restore Report Code 009
429 Dialer Option 129 (Dial Phone 1)
This is not a complete Programm Sheet!