Alarmlock Eagle 8000DL Program

Enter Program 1. Hold 8 key for 3 seconds, keypad will beep
2. Enter 4 5 6 7 8 9, display should show dash
Move to Location 1. Press [S], display will show 3 dashs, enter 3-digit location
2. What is programmed in location will display, use 4 and 7 keys to change data
3. Once correct data displays press 2 to move to next location
Exit Program 1. Hold 8 key 3 seconds, keypad will flash and beep
2. Enter 4 5 6 7 8 9, display should return to normal
IF something gets screwed up power down then up, there is 30 seconds to get into program

Report Options
To program REPORT OPTIONS in locations 166 to 185 see below Diagram
Add location together and enter sum in location
Example: Enable Reporting for Zones 1 to 6, Keypad Panic, Fire, Duress, Fire Trle, AC Fail and Low Bat
1. Press B/A then 1 6 6 to move to Location 166
2. Add ZONE 1 (1) + ZONE 2 (2) + ZONE 3 (4) + ZONE 4 (8) = 15 or F, enter the F in location 166
3. Press 2 key to move to 167
4. Add Zone 5 (1) + Zone 6 (2) + Keypad Panic (8) = 11 (B), enter the B in location 167
5. Press 2 key to move to 168
6. Add FIRE ZONE (1) + AMBUSH (2) + FIRE TROUBLE (4) = 7, enter the 7 in location 168
7. Press 2 key to move to 169
8. Add AC FAIL (2) + LOW BAT (4) = 6, enter the 6 in location 169
166 – Report Enable Zns 1 to 4 I_F_I 168 – Fire/Duress, Fire Trouble I_7_I
167 – Report Enable Zns 5, 6 & Panic I_D_I 169 – AC Fail/Low Bat Trouble I_6_I
170 – 171 – Restores Enabled I_ _I_ _I 172 – 173 – Misc Restores I_ _I_ _I
(Blank out this section) (Blank out this section)
184 – 185 – Zone Restores I_ _I_ _I
(Blank out this section)

Report Codes
000 – 001 Zone 1 Report Code I_3_I_1_I 014 – 015 Keypad Panic I_2_I_1_I
002 – 003 Zone 2 Report Code I_3_I_2_I 016 – 017 Fire Panic/Smoke I_2_I_3_I
004 – 005 Zone 3 Report Code I_3_I_3_I 018 – 019 Hostage/Duress I_2_I_2_I
006 – 007 Zone 4 Report Code I_3_I_4_I 020 – 021 Fire Trouble I_7_I_6_I
008 – 009 Zone 5 Report Code I_3_I_5_I 022 – 023 Day Zone Trouble I_ _I_ _I
010 – 011 Zone 6 Report Code
(If Smoke on Zone 6 program 1 6)
I_3_I_6_I 024 – 025 Test Timer I_ _I_ _I
026 – 027 AC Failure I_7_I_9_I
028 – 029 Low Battery I_7_I_8_I
(I_ _I_ _I = Blank out Locations with 5 key)

Restore Codes
040 – 041 Zone 1 Restore I_ _I_ _I     056 – 057 Fire Panic/Smoke I_ _I_ _I
042 – 043 Zone 2 Restore I_ _I_ _I 058 – 059 Not Used I_ _I_ _I
044 – 045 Zone 3 Restore I_ _I_ _I 060 – 061 Fire Trouble I_ _I_ _I
046 – 047 Zone 4 Restore I_ _I_ _I 062 – 063 Not Used I_ _I_ _I
048 – 049 Zone 5 Restore I_ _I_ _I 064 – 065 Not Used I_ _I_ _I
050 – 051 Zone 6 Restore I_ _I_ _I 066 – 067 AC Trouble Restore I_ _I_ _I
(Blank out everything with 5 key) 068 – 069 Low Battery Restore I_ _I_ _I

Opening/Closings/Cancel
030 – 031 Closing User 1 I_ _I_ _I 070 – 071 Opening User 1 I_D_I_1_I
032 – 033 Closing User 2 I_ _I_ _I 072 – 073 Opening User 2 I_D_I_1_I
034 – 035 Closing User 3 I_ _I_ _I 074 – 075 Opening User 3 I_D_I_1_I
036 – 037 Closing User 4 I_ _I_ _I 076 – 077 Opening User 4 I_D_I_1_I
038 – 039 Force Arm I_ _I_ _I (These are Cancels, see also section 179)

174 – Select User Closings I_ _I_ _I 176 – Select User Openings I_ _I_ _I
(I_ _I_ _I = Blank out Locations with 5 key)

Account Numbers
Telephone Number 1 (Last 4 of Account must be entered in each section)
Group 1
100 – 103 Last 4 of Account
I_?_I_?_I_?_I_?_I
Group 2
104 – 107 Last 4 of Account
I_?_I_?_I_?_I_?_I
Opening/Closings
108 – 111 Last 4 Account
I_?_I_?_I_?_I_?_I
Telephone Number 2 (Blank These Sections Out with 5 key)
132 – 135 Last 4 of Account
I_ _I_ _I_ _I_ _I
136 – 139 Last 4 of Account
I_ _I_ _I_ _I_ _I
140 – 143 Last 4 Account
I_ _I_ _I_ _I_ _I

Phone Numbers
112 – 113 Report Format Phone 1 I_9_I_2_I
First Digit
Blank = Ademco/Silent Knight Slow
1 = Sescoa, Vertex, DCI, Franklin
2 = Radionics Fast
3 = Silent Knight Fast
4 = Radionics, DCI, Franklin Slow
5 = Universal Hi Speed
8 = 2300 Handshake (Add this to above numbers)
Second Digit
Blank = Extended or Single Digit
1 = Single Digit
2 = 2-Digit (4/2)
4 = Sumcheck
114 – 115 Receiver 1 Options I_ _I_ _I (Add 9 in 115 if 9 is needed to dial out)
116 – 131 Receiver 1 Phone (16 Digits) I_E_I_1_I_8_I_?_I_?_I_?_I_?_I_?_I_?_I_?_I_?_I
144 – 145 Report Format Phone 2 I_ _I_ _I (Leave these blank)
146 – 147 Receiver 2 Options I_ _I_ _I (Leave these blank)
148 – 163 Receiver 2 Phone I_N_I_O_I_T_I_ _I_U_I_S_I_E_I_D_I_ _I_ _I_ _I
269 Rings before Download I_A_I (10 rings until Answer)
270 – 285 Download Phone I_B_I_L_I_A_I_N_I_K_I_ _I_O_I_U_I_T_I_ _I_ _I

Misc Functions
To program sections 084 to 216 see below Diagram

Add location together and enter sum in location
Example: Program Zones 1, 3 4, 5 and 6 for Door Chime
1. Press B/A then B/A again then 8 8 to enter Location 088
2. Add Zone 1 (1) + Zone 2 (2) + Zone 4 (8) = 11 or B, enter B in location 088
3. Press 2 key to move to 089
4. Add Zone 5 (1) + Zone 6 (2) = 3, enter 3 in location 089
084 – 085 Swinger Shutdown I_F_I_3_I (Swinger enabled on all zones)
086 – 087 No EOL Zone Resistors I_ _I_ _I (Blank = No EOL, F 3 = EOL all zones)
088 – 089 Chime Zones 1 to 6 I_ _I_ _I (Turns on/off chimes per zone)
090 – 091 Never Arm I_ _I_ _I (Leave blank)
092 – 093 PIR Zone I_ _I_ _I (Program PIR zones here. also see 206 – 207)
096 – 099 Untimed Output to Lug E15 I_F_I_B_I (Normally not programmed)
164 – 165 KP Sounder on Alarm I_ _I_ _I (Leave blank)
186 – 187 Day Zone I_ _I_ _I (Leave blank)
188 – 189 Priority Zone W/Bypass I_ _I_ _I (Leave blank)
190 – 191 Priority Zone I_F_I_3_I (Default = F 3, leave alone)
192 – 193 Remove Auto-Bypass I_ _I_ _I (Leave blank)
194 – 195 Selective Bypass I_F_I_3_I (Default = F 3, leave alone)
196 – 197 Group Bypass I_?_I_?_I (any zone here will bypass by B/A key twice)
198 – 199 24 hr Protection I_ _I_D_I (Use if Hold-Up buttons on a zone)
200 – 201 Auto Reset I_F_I_D_I (Default = F D, leave alone)
202 – 203 Entry/Exit Delay 1 Zones I_?_I_?_I (Program which zones are Delay 1)
204 – 205 Entry/Exit Delay 2 Zones I_?_I_?_I (Program which zones are Delay 2)
206 – 207 Interior Follower Zones I_?_I_?_I (Program PIR zones here. also see 092 – 093)
208 – 209 Abort Delay per Zone I_ _I_ _I (Leave blank)
210 – 211 Burglary Output per Zone I_F_I_F_I (Unless using Silent Panic leave at F 3)
212 – 213 Timed Negative Output I_ _I_ _I (Leave blank)
214 – 215 7ms Loop Response I_ _I_ _I (Leave blank)
216 – 217 50ms Loop Response I_ _I_ _I (Leave blank)

User Codes
236 – 237 Hostage/Duress Code I_9_I_9_I
238 – 243 User Program Code I_1_I_2_I_3_I_4_I_5_I_6_I
Note: allows customer to change User codes, leave at default
If Changed Make a note on the account and on the panel.
244 – 249 Installer/Dealer Code I_4_I_5_I_6_I_7_I_8_I_9_I
(User Codes MUST be programmed at User Level, not in Programming)

Misc Options
Add each section, place total in box (Example: 1 + 4 + 8 = 13 or “D”) I_ _I = Blank Out with 5 key
078 I_4_I 178 I_2_I 182 I_6_I
1 = Desplay Day Zone/Reset
2 = Fail to Com on NTO Lug
4 = User 5 Quick Arm
8 = User 5 Report as User 1
1 = Touchtone Dialing
2 = Touchtone/Rotary Backup
3 = Backup Reporting
4 = Double Reporting
1 = Disable Fault Find
2 = Enable Keypad Panic
4 = Enable Comunicator Test
8 = Disable Bell Test

079 I_ _I 179 I_1_I 183 I_ _I
1 = User 5 Service Code
2 = Disable Day Zn Report
4 = Reserved
8 = Reserved
1 = Opening after Alarm
2 = Force Arm
4 = Status Report
8 = Split Report
1 = Disable any Bypass
2 = No Open Rep Alarm on Zn 6
4 = Incl Man Byp in Force Arm
8 = Reserved

080 I_ _I 180 I_2_I
1 = Direct KP Panic to Ambush
2 = Reserved
4 = Disable Callback Download
8 = Disable Function 6 Download
1 = Audible Test on Arming
2 = Auto-Reset after Timeout
4 = Power Up in Last State
8 = Sounder Output on E4 Lug

081 I_ _I 181 I_3_I
1 = Watch on With Group Byp
2 = Chime On with Group Byp
4 = Display Chime Zones
8 = Disable Display Bypass
1 = Pulsing Fire
2 = Reset Fire Zone
4 = Reserved
8 = Reset Tst Timer on Report

082 I_1_I
1 = Enable Download w/Ans Machine
2 = Remote Status LED on NTO Lug
4 = Reserved
8 = Reserved

System Times
E/E Times found by dividing desired time by 16
Enter 1st digit of resut in second box and 2nd digit of result in 1st box (wierd ain’t it?)
094 – 095 Sensor Watch I_ _I_ _I (Leave both blank, not used)
218 – 219 Exit Delay I_C_I_3_I (60 seconds)
220 – 221 Entry Delay 1 I_E_I_1_I (30 seconds)
222 – 223 Entry Delay 2 I_E_I_1_I (30 seconds)
224 – 225 Burg Timeout I_6_I_ _I (6 minutes, leave 2nd entry blank)
228 – 229 Fire Timout I_F_I_ _I (Unlimited, leave 2nd entry blank)
230 – 231 Chime Duration I_4_I_ _I (1/2 second Chime, leave 2nd entry blank)
232 – 233 Abort Delay I_ _I_ _I (Leave both blank, not used)
250 – 251 Test Timer I_ _I_ _I (Leave both blank, not used)