Alarmlock Eagle 6000 Program

Enter Program Run jumper from terminals 3 and 6, hold 8 key 3 seconds
Exit Program Remove Jumper, press * and #
Move to Location Press [B] + 2 digit location
1 = scroll through digits
2 = Clears display
3 = Advances to next location

Zone 1
Zones 2 & 3
Zones 4 and 6
Zone 5
must be E/E
must be Follower
must be Instant
can be Instant Zone, Panic and/or Holdup

Report Options

B11 = User Code 1 (Master) ? ? ? ? (4-digits, can’t use 0)
B12 = User Code 2 ? ? ? ?
B13 = User Code 3 ? ? ? ?
B14 = User Code 4 ? ? ? ?
B15 = Entry Delay ? (x10 seconds)
B16 = Exit Delay ? (x10 seconds)
B17 = Enable 1 digit Arming ?
Note: Above sections can be accessed in User Programming. Press 8 for 3 secs then Master Code
B29 = Report on Alarm
  Report Enable Zns 1 to 4
  Report Enable Zns 5, 6 & Panic
Entry is F & 3
F
3
B45 = Misc Report Enable
  Fire/Duress, Fire Trouble
  Low Battery Trouble
Entry is 3 & _
3
_
B39 = Restores Enabled
  * = Blank this section
Entry is _ _ B49 = Misc Restores
  * = Blank this section
Entry is _ _

Report Codes

B21 – B26, B41 – B42 B31 – B36, B46 – B47
B21 – Zone 1
B22 – Zone 2
B23 – Zone 3
B24 – Zone 4
B25 – Zone 5*
B26 – Zone 6
B41 – No AC Trouble
B42 – Low Battery
3 1
3 2
3 3
3 4
0 2
3 6
_ _
7 8
B31 – Zone 1 Restore
B32 – Zone 2 Restore
B33 – Zone 3 Restore
B34 – Zone 4 Restore
B35 – Zone 5 Restore
B36 – Zone 6 Restore
B46 – AC Restore
B47 – Low Batt Restore
_ _
_ _
_ _
_ _
_ _
_ _
_ _

_ _

*Zone 5 is Police Panic * & #     _ _ = All Blank

Opening/Closings/Cancel

B43 – Closing Report _
B44 – Force Arm Report _
B48 – Opening Report D

Account Numbers

B51 = Last 4 of Account B52 = Last 4 of Account
Note: Last 4 of Account must be entered in both sections

Phone Numbers

B52 = Report Format Phone 1 _ 0 (Ademco Slow, 4/2+2300)
B53 = Receiver 1 Phone _ _ E 1 8 0 0 x x x x x x x (first 2 entries blank)
B55 = Receiver Format Phone 2 Leave Blank
B56 = Receiver 2 Phone Leave Blank

Misc Functions

Program these sections by adding 1 2 3 4 together for sum
1st section
Zone 1 = 1
Zone 2 = 2
Zone 3 = 4
Zone 4 = 8
2nd section
Zone 5 = 1
Zone 6 = 2
Not Used = 4
KP Panic = 8
Example: add 1 to 8 together to get total entered section
“088 – 089 Chime Time”, to program Zones 1 2 and 4 for
Chime, add 1 + 2 + 8 = D, enter in section 088, blank 089
B59 = Day Zone _ _ (Leave blank)
B61 = Priority Zone F 3 (By default this is F 3, leave alone)
B62 = Auto-Bypass ? ? (Leave alone)
B63 = Selective Bypass F F (Allows Bypassing of Zones
Note: if Smoke Detector on a Zone disable Selective Bypass for that zone
B64 = Group Bypass ? ?
Note: If a zone is enabled as Group Bypass it can be bypassed
            by pressing [B] key twice.
B65 = 24 hr Protection ? ? (Normally don’t program)
Note: If using Hold-Up buttons on a zone enable this option for that zone
B66 = Auto Reset F 3 (By default this is F 3, leave alone)
B67 = Abort Delay _ _ (Leave blank)
B68 = Alarm Output F 3 (Leave Alone)
B71 = 10ms Loop Response ? ? (Leave Alone)
B72 = 50ms Loop Response ? ? (Leave Alone)
B57 = Misc Options D _
Note: This just enables KP Panic on Zone 5 and Cancel Code

System Times

B73 = Output 1 Timout 1 (Siren Timout x5 minutes)
B75 = Line Seizure Time 2 (2 by default, leave alone)
B76 = Anti-Jam Time 3 (3 by default, leave alone)
B77 = Redial Delay Time 4 (4 by default, leave alone)
B78 = Abort Delay _ (no time, leave alone)
B79 = Wait for Handshake 7 (7 by default, leave alone)
B58 = Redial Attempts 9 _ (9 times, leave 2nd blank)