Ademco Vista 40 Trouble
bF | Long Range Radio trouble |
NO AC | AC Power Failure |
BAT | Backup Battery low |
BAT 01 – 63 | Zone has low battery (If 4 zones show at once likely Keyfob low battery) |
BAT 00 | Low Remote Keypad battery |
CHECK 01 – 63 | Wireless zone not communicating with panel |
CHECK 87 | 4285 Voice Module Trouble |
CHECK 97 | Short in Polling Loop |
CHECK 88 | Wireless Zones not communicating with 2nd Receiver |
CHECK 89 | 2nd Receiver Failure |
CHECK 90 | Wireless Zones not communicating with 1st Receiver |
CHECK 91 | 1st Receiver Failurel |
D1 or SYSTEM BUSY |
System in wait mode, if it stays on system has internal problem |
CA | Alarm was canceled, this is not a trouble |
CC | Panel is being downloaded by Tech Support |
EA | Exit Alarm, this is not a trouble, customer armed system left and didn’t close door before delay expired |
FC | Fail to Communicate |
E4 or E8 | More zones were programmed than wireless receiver is capable of |
OC | Open Circuit, bad keypad wire |
One Beep every 40 Sec |
System is in Test Mode (Press Code + 1 to exit Test Mode) |
Smoke Batteries |
Remove old batteries, hold Smoke test button 30 seconds, Insert new batteries |