Enter Program 5140 + 8 + 0 + 0 (Display should show 00)
or Power down then back up and press * and # within 1 minute
(If exiting programming you can re-enter within 1 minute by pressing * and #)
Exit Program 1. *98 OR 2. *99 if needing to re-enter programming later by Code + 8 + 00
Move to Location * + Location
View Location # + Location (Display will read off one digit at a time)

All Zone programming is done by # 93 menu, Click to go to section
ZONE PROG? 0 (No) for next menu, 1 (Yes) to enter this menu (Completed)
EXPERT MODE? 0 (No) for next menu, 1 (Yes) to enter this menu (Completed)
REPORT CODE PRG? 0 (No) for next menu, 1 (Yes) to enter this menu (Completed)
ALPHA PROG? 0 (No) for next menu, 1 (Yes) to enter this menu (Under Construction)
DEVICE PROGR? 0 (No) for next menu, 1 (Yes) to enter this menu (Under Construction)
OUTPUT PROG? 0 (No) for next menu, 1 (Yes) to enter this menu (Under Construction)
RLY VOICE DESCR? 0 (No) for next menu, 1 (Yes) to enter this menu (Under Construction)
CUSTOM INDEX? 0 (No) moves back to start, 1 (Yes) to enter this menu (Under Construction)

*00 Installer Code I_5_I_1_I_4_I_0_I

*08 Temporal Siren Pulse I_0_I 0 = No
1 = Yes

*09 Entry Delay I_0_I_2_I 00 to 15 x15 seconds (Partition-Specific)

*10 Exit Delay 1 I_0_I_4_I 00 to 15 x15 seconds (Partition-Specific)

*11 Entry Delay 2 I_0_I_3_I 00 to 15 x15 seconds (Partition-Specific)

*12 Exit Delay 2 I_0_I_4_I 00 to 15 x15 seconds (Partition-Specific)

*13 Bell 1 Timeout I_0_I_8_I 00 to 15 x2 minutes (Partition-Specific)

*15 Keyswitch Assignment I_0_I 0 = Keyswitch Disabled
1 = Partition 1
2 = Partition 2
9 = Silence Bell if Fire Present

*16 Bell 1 Arming Ding I_0_I 0 = Disable (Partition-Specific)
1 = Enable

*17 AC Loss Keypad Sounding I_1_I 0 = No
1 = Yes

*19 AC Randomize I_2_I 0 = No
1 = Randomize 10 – 40 minutes
2 = Randomize 6 – 12 Hours

*20 VIP Module Phone Code I_0_I_0_I I_1_I_1_I 1st Digit = 01 to 09
* 12 for #

*22 Keypad Panic Enable I_1_I I_1_I I_1_I
1st Digit = Zone 995
2nd Digit = Zone 996
3rd Digit = Zone 999
0 = Disabled (Partition-Specific)
1 = Enabled

*23 Multiple Alarms I_1_I 0 = No (Partition-Specific)
1 = Yes

*24 Ignore Expansion Zone Tamper I_0_I 0 = Enable Tamper for RF & RPM
1 = Ignore Zone Tampers

*25 LRR Burglary Trigger for ZType 8 I_0_I 0 = No
1 = Yes

*26 Intelligent Test Reporting I_0_I 0 = No
1 = No Report if other Reports Sent

*27 Test Report Interval I_0_I_2_I_4_I 000 = Disabled
001 to 999 Hours

*28 Power up in Previous State I_1_I 0 = No
1 = Yes

*29 Quick Arm I_1_I 0 = No (Partition-Specific)
1 = Yes

*30 Main Dialer TouchTone Dialing I_1_I 0 = No
1 = Yes

*31 PABX Access Code I_ _I_ _I I_ _I_ _I I_ _I_ _I I_ _I_ _I

*32 Primary Account Number I_0_I_?_I I_0_I_?_I I_0_I_?_I I_0_I_?_I (2 digit entries) (Partition-Specific)
Hex B = 11, C = 12, D = 13, E = 14, F = 15

*33 Primary Phone Number (12 digits) I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I End Phone with *
# + 11 = *, # + 12 = #, # + 13 = 2.5 second pause

*34 Secondary Phone Number I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I

*35 Download Phone Number I_1_I_8_I_0_I_0_I_7_I_6_I_2_I_7_I_8_I_3_I_1_I_ _I_ _I_ _I_ _I

*36 CSID Number I_1_I_5_I_1_I_5_I_1_I_5_I_1_I_5_I_1_I_5_I_1_I_5_I_1_I_5_I_1_I_5_I
(15’s Default CSID to Factory)

*37 Download Commands Enable I_1_I Dialer Shutdown
I_1_I System Shutdown
I_0_I Not Used
I_1_I Remote Bypass
I_1_I Remote Disarm
I_1_I Remote Arm
I_1_I Upload Programming
I_1_I Download Programming
0 = No
1 = Yes
*38 Prevent Zone Bypass I_0_I_0_I_0_I 000 = All zones bypassable (Partition-Specific)
001 to 032 = Zone 01 to 32

*39 Open/Close Report for Installer I_0_I 0 = No (Partition-Specific)
1 = Yes

*40 Open/Close Report for Keyswitch I_0_I 0 = No
1 = Yes

*41 Normally Closed Zones 3 to 8 I_0_I 0 = EOL Resistors
1 = Normally Closed

*42 Dial Tone Pause I_0_I 0 = 5 seconds
1 = 11 seconds
2 = 30 seconds

*43 Dial Tone Detection I_0_I 0 = Pause then Dial
1 = Wait for True Dial Tone

*44 Ring Detection Count I_1_I_5_I 15 = Answering Machine

*45 Primary Format I_1_I 0 = Ademco Lo
1 = Contact ID
2 = Ademco High Speed
3 = Ademco Express

*46 Low Speed Format (Primary) I_0_I 0 = Ademco Low Speed
1 = Sescoa/Radionics

*47 Secondary Format I_1_I 0 = Ademco Lo
1 = Contact ID
2 = Ademco High Speed
3 = Ademco Express

*48 Low Speed Format (Secondary) I_0_I 0 = Ademco Low Speed
1 = Sescoa/Radionics

*49 Checksum Verify
I_0_I
Pri
I_0_I
Sec
0 = No
1 = Yes
*50 Sescoa Radionics Select I_0_I 0 = Radionics
1 = Sescoa

*51 Dual Reporting I_0_I 0 = No
1 = Yes

*52 Standard/Expanded Report
for Primary
I_0_I Alarm/Fire Supv
I_0_I Restore
I_0_I Bypass
I_0_I Trouble
I_0_I Open/Close
I_0_I Low Bat/Walk Test
0 = Standard
1 = Expanded
*53 Standard/Expanded Report
for Secondary
I_0_I Alarm/Fire Supv
I_0_I Restore
I_0_I Bypass
I_0_I Trouble
I_0_I Open/Close
I_0_I Low Bat/Walk Test
0 = Standard
1 = Expanded
*56 Dynamic signaling delay I_0_I_2_I 00 to 15 x15 seconds

*57 Dynamic signaling priority I_0_I 0 = Telephone First
1 = Long Range Radio First

*58 Long Range Radio Enable CS#1 I_0_I Alarm
I_0_I Trouble
I_0_I Bypass
I_0_I Open/Close
I_0_I System
I_0_I Test
0 = Disable
1 = Enable

*59 Long Range Radio Enable CS#2 I_0_I Alarm
I_0_I Trouble
I_0_I Bypass
I_0_I Open/Close
I_0_I System
I_0_I Test
0 = Disable
1 = Enable

*64 Pager Installed I_0_I 0 = No
1 = Yes

*65 Pager Phone for Alarms (17 digits) I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I End Phone with *
# + 11 = *, # + 12 = #, # + 13 = 2.5 second pause

*66 Pager ID# for Alarms (10 digits) I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I End with *

*67 Pager Phone for Trouble (17 digits) I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I End Phone with *
# + 11 = *, # + 12 = #, # + 13 = 2.5 second pause

*68 Pager ID# for Trouble (10 digits) I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _IEnd with *

*69 Pager Phone for Bypass (17 digits) I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I End Phone with *
# + 11 = *, # + 12 = #, # + 13 = 2.5 second pause

*70 Pager ID# for Bypass (10 digits) I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I End with *

*71 Pager Phone for O/C (17 digits) I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I End Phone with *
# + 11 = *, # + 12 = #, # + 13 = 2.5 second pause

*72 Pager ID# for O/C (10 digits) I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I End with *

*73 Pager Phone for System (17 digits) I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I End Phone with *
# + 11 = *, # + 12 = #, # + 13 = 2.5 second pause

*74 Pager ID# for System (10 digits) I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _IEnd with *

*75 Pager Phone for Test (17 digits) I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I End Phone with *
# + 11 = *, # + 12 = #, # + 13 = 2.5 second pause

*76 Pager ID# for Test (10 digits) I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I End with *
*79 Zone Type Restore Enable Zone Types 1 to 8
I_0_I Zone Type 1 (Entry/Exit 1)
I_0_I Zone Type 2 (Entry Exit 2)
I_0_I Zone Type 3 (Perimeter)
I_0_I Zone Type 4 (Interior Follower)
I_0_I Zone Type 5 (Day/Night)
I_0_I Zone Type 6 (24 Hour Silent)
I_0_I Zone Type 7 (24 Hour Audible)
I_0_I Zone Type 8 (24 Hour Auxiliary)
0 = No Restoral Report
1 = Restoral Report
*80 Zone Type Restore Enable Zone Types 9 and 10
I_0_I Zone Type 9 (Fire w/o verify)
I_0_I Zone Type 10 (Interior w/Delay)
0 = No Restoral Report
1 = Restoral Report
*83 First Test Report Time I_0 I_0_I I_1_I_2_I I_0_I_0_I 00 ina all boxes = instant.
Day Hour Minutes Day 01 = Monday
*84 Swinger Shutdown I_0_I_4_I 00 = Disabled (Partition-Specific)
01 to 15 = 01 to 15 Alarms

*85 Enable Dialer Reports I_1_I Zone 995
I_1_I Zone 996
I_1_I Zone 999
I_1_I Duress
0 = Disable (Partition-Specific)
1 = Enable

*87 Entry Warning I_1_I 0 = 3 Beeps (Partition-Specific)
1 = Continuous

*88 Burglar Alarm Comm Delay I_0_I 0 = No Delay (Partition-Specific)
1 = 16 seconds

*89 Restore Report Timing I_0_I 0 = Instant
1 = At Bell Timeout
2 = At Disarm

*90 Secondary Account Number I_ _I_ _I I_ _I_ _I I_ _I_ _I I_ _I_ _I (2 digit entries)
Hex B = 11, C = 12, D = 13, E = 14, F = 15


To access Upper programming press *94, to return to lower programming press *99
the 1 isn’t part of location, to go to a Upper program location press * + 2-digits

1*17 Common Lobby Partition I_0_I 0 = Disabled
1 = Partition 1
2 = Partition 2

1*18 Affects Lobby I_0_I 0 = Does Not Affect Lobby (Partition-Specific)
1 = Affects Lobby (Disarms lobby and keeps from arming)

1*19 Arms Lobby I_0_I 0 = Does Not Arm Lobby (Partition-Specific)
1 = Arms Lobby

1*20 Exit Error Logic I_0_I 0 = No
1 = Bypass E/E & Interior Zones
faulted after Exit Delay

1*21 Exit Delay Reset I_0_I 0 = No
1 = Resets Exit Delay to 60 seconds
after Zone is Closed

1*22 Cross-Zoning Pair One I_ _I_ _I I_ _I_ _I
1*23 Cross-Zoning Pair Two I_ _I_ _I I_ _I_ _I
1*24 Cross-Zoning Pair Three I_ _I_ _I I_ _I_ _I
1*25 Cross-Zoning Pair Four I_ _I_ _I I_ _I_ _I

1*26 Enable Dialer Reports I_0_I_0_I 995 Panic Button A
I_0_I_0_I 999 Panic Button B
I_0_I_0_I 996 Panic Button C
I_0_I_0_I Macro selector Button D
00 = Used as Panic (Partition-Specific)
01 to 25 = Macro
1*28 RF TX Low Battery Sound I_0_I 0 = When Disarmed
1 = Immediate

1*29 RF TX Low Battery Report Enable I_0_I 0 = Disable
1 = Enable

1*30 RF RCVR Check-In Interval I_0_I_2_I 02 to 15 x2 Hours
1*31 RF Transmitter Check-In Interval I_0_I_2_I 02 to 15 x2 Hours

1*33 Touch Tone with Rotory Backup I_1_I 0 = Disable
1 = Enable

1*34 Comm Split Report Selection I_0_I 0 = No
1 = Alarms to Primary, others Sec.
2 = O/C/Test Secondary, others Pri.
3 = Fire alarms/troubles Primary, all Sec.

1*35 Access Dialer Enables I_0_I Trace
I_0_I Trouble
I_0_I Bypass
I_0_I System
I_0_I Alarm
0 = Disable
1 = Enable

1*42 Call Waiting Defeat I_0_I 0 = No
1 = Yes

1*43 Perm Keypad Backlight I_1_I 0 = No (Partition-Specific)
1 = Yes

1*44 Wireless Keypad Tamper Detect I_0_I 0 = Disable
1 = Lockout RF if tamper detected

1*45 – Exit Delay Sounder I_0_I 1 = Enable (Partition-Specific)
0 = Disable

1*47 Chime on Bell 1 I_0_I 0 = Disable (Partition-Specific)
1 = Enable

1*48 Wireless Keypad Assignment I_0_I 0 = Disable
1 = Partition 1
2 = Partition 2

1*49 Suppress TX Supervision Sound I_1_I 0 = Enable
1 = Disable

1*52 Send Cancel if Alarm + Off I_0_I 0 = No Restriction (Partition-Specific)
1 = Within Bell Timeout

1*53 Download Callback I_1_I 0 = Callback Required
1 = No Callback

1*56 50/60 Hz Clock Speed I_0_I 0 = 60 Hz
1 = 50 Hz

1*57 Enable 5800RF Global Arm I_0_I 0 = Disable
1 = Enable

1*58 Enable 5800RF Force Arm I_0_I 0 = Disable
1 = Enable

1*60 Zone 5 Audio Alarm Verification I_0_I 0 = Disable
1 = Enable

1*70 Event Log Types I_1_I Alarm
I_1_I Check
I_1_I Bypass
I_1_I O/C
I_1_I System
0 = Disable Logging
1 = Enable Logging

1*71 12/24 Hour Time Stamp Format I_1_I 0 = 12 Hour
1 = 24 Hour (Military)

1*72 Event Log Printer On-line Mode I_0_I 0 = Disable
1 = Enable

1*73 Printer Baud Rate I_0_I 0 = 1200 Baud
1 = 300 Baud

1*74 Relay Timeout XXX Min. I_0_I_0_I_0_I 0 to 127 x2 Minutes
Enter relay timeout desired for #80 Menu Mode
time-driven event relay command
numbers “04/09” and #93 Menu Mode
Output Programming output command “56.”

1*75 Relay Timeout YYY Sec. I_0_I_0_I_0_I 0 to 127 Seconds
Enter relay timeout desired for #80 Menu Mode
time-driven event relay command
numbers “05/10” and #93 Menu Mode
Output Programming output command “57.”

1*76 Access Control Relay I_0_I_0_I 00 to 96 (Partition-Specific)
Relay will be pulsed for 2 seconds
whenever code + [0] is pressed.

1*77 Log First Maint. Signal I_0_I 0 = Disable
1 = Enable


To access Upper programming press *94, to return to lower programming press *99
the 2 isn’t part of location, to go to a Upper program location press * + 2-digits

2*00 Number of Partitions I_1_I 1 = 1 Partition
2 = 2 Partitions

2*01 DST Start/End Month I_0_I_3_I I_1_I_1_I 00, 00 = Disable DST
Start End 01 – 12 = Month

2*02 DST Start/End Weekend
I_2_I
Start
I_1_I
End
1 to 7
1 = First
2 = Second
3 = Third
4 = Fourth
5 = Last
6 = Next to Last
7 = Third from Last
2*05 Auto-Arm Delay I_1_I_5_I 00 = Instant (Partition-Specific)
01 to 14 x4 Minutes
15 = No Auto-Arm

2*06 Auto-Arm Warning Period I_1_I_5_I 00 = Instant (Partition-Specific)
01 to 15 Minutes

2*07 Auto-Disarm Delay I_1_I_5_I 00 = Instant (Partition-Specific)
01 to 14 x4 Minutes
15 = No Auto-Disarm

2*08 Force Arm for Auto-Arm I_0_I 0 = Disable (Partition-Specific)
1 = Enable

2*09 O/C Reports by Exception I_0_I 0 = Disable (Partition-Specific)
1 = Enable

2*10 Allow Disarming Only During
Arming/Disarming Windows
I_0_I 0 = Disable (Partition-Specific)
1 = Enable

2*11 Allow Disarming Outside Window
if Alarm Occurs
I_0_I 0 = Disable (Only used if 2*10 is a 1)
1 = Enable

2*18 Enable Go To for Partition I_0_I 0 = Disable (Partition-Specific)
1 = Enable

2*19 Use Partition Descriptors I_0_I 0 = Disable
1 = Enable

2*20 Enable J2 Triggers for Partition I_0_I 0 = Disable (Partition-Specific)
1 = Enable

2*21 Enable Supervision Pulses
For LRR Trigger Outputs
I_0_I Fire
I_0_I Burglary
I_0_I Silent panic/Duress
I_0_I Supervision
I_0_I Trouble
0 = Disable
1 = Enable
2*22 Display Fire Alarms of Other I_0_I 0 = Disable (Partition-Specific)
Partitions 1 = Enable

2*23 Display Burglary & Panic Alarms I_0_I 0 = Disable (Partition-Specific)
of Other Partitions 1 = Enable

2*24 Display Troubles of Other I_0_I 0 = Disable (Partition-Specific)
Partitions 1 = Enable


To access Upper programming press *94, to return to lower programming press *99
the 3 isn’t part of location, to go to a Upper program location press * + 2-digits

3*00 Check or Trouble Display I_0_I 0 = Check Displayed
1 = Trouble Displayed

3*01 Check or Trouble Display I_0_I 0 = Check Displayed
1 = Trouble Displayed

3*12 Zone Type 18 Delay Use I_0_I 0 = No Delay Zone 18
1 = Use Delay in 3*16

3*13 Supervisory on Open and Short I_0_I 0 = Supv. on short/trouble on open
1 = Supv. on short or open

3*14 Waterflow Silence Option I_0_I 0 = Silence on Code + 1
1 = Silence on restoral

3*15 Alarm Bell Sound I_0_I Bell 1
I_0_I Bell 2
0 = Pulsed
1 = Steady

3*16 Delay for Zone Types 17 & 18 I_0_I_0_I 00 to 15 x2 seconds
(Waterflow & Fire Supervision)

3*17 Alt Function (Tamper) for Zone 6 I_0_I_0_I 0 = Disabled
1 = Enabled

3*18 Extended Delay for ZT 17 & 18 I_0_I 0 = Use Delay in 3*16
1 = Multiply 3*16 delay by 4

3*19 AUX in Alternate Function I_0_I 0 = Pins 5 & 9 function per 3*20
1 = Pins 5 & 9 as printer RXD & DTR

3*20 Trigger Outputs Selection I_0_I 0 = Lorra Full Connection
1 = Lorra Limited Connection/Keyswitch
2 = Lorra Fire Connection & 5140LED

3*21 Max # of Dialer Retries I_8_I 1 to 8 attempts

3*30 Dialer Selection I_1_I Main
I_1_I Backup
0 = Disabled
1 = Enabled

3*31 Backup Dialer Touch Tone/Rotary I_0_I 0 = Rotary
1 = Touch Tone

3*50 Zone Type Restore Enable
For Zone Types 16 to 18
16 = Fire w/Verification
17 = Fire Water Flow
18 = Fire Supervisory
I_1_I Zone Type 16
I_1_I Zone Type 17
I_1_I Zone Type 18
0 = Disabled
1 = Enabled

3*55 Reset Bell 1 After Second off I_0_I 0 = Disabled
1 = Enabled

3*56 Reset Bell 2 After Second off I_0_I 0 = Disabled
1 = Enabled

3*57 Bell 2/Aux Relay arm Ding I_0_I Bell 2
I_0_I Aux
0 = Disabled (Partition-Specific)
1 = Enabled

3*59 Bell 2/Aux Relay Chime Annunciation (Partition-Specific)
I_0_I Bell 2
I_0_I Aux
0 = Disabled
1 = Enabled

3*60 Bell 2/Aux Relay Timeout I_0_I_0_I Bell 2
I_0_I_0_I Aux
0 = Disabled (Partition-Specific)
1 = Enabled

3*61 Aux Relay Function I_0_I 0 = Trouble/Supervisory
1 = Alarm/Silenced by Code + OFF
2 = Smoke Detector Reset
3 = Battery Save
4 = Alarm, Silenced by
Code + # + 67

3*82 Enable Burg Features on Par 1 I_1_I 0 = Disable
1 = Enable

(Away, Stay, Max, Test, Instant, Chime Functions)
3*85 Enable Fire & System Zone Bypass I_1_I 0 = Not Enabled
1 = Only Installer can Bypass
2 = Only Installer & Master can Bypass
(For Zone Types 9, 16, 17 & 18 & Zones 70 to 77)