Zones 9 Hardwired 22 Expansion (Wireless or Hardwired w/4208U)
Partitions 2
Downloadable Yes
Wireless Yes
Batteries
Main Panel
AC Transformer
Doors/ Windows/Motions
Smoke Detector
Keyfobs and Panics
12 volt rechargeable Gel-Cell inside main panel
is 16.5 Volts
3-volt Lithium (Panasonic CR123A)
2 9-volt Alkalines
2 3-volt Lithium (CR2025 or CR2430 Lithium)
Panic Buttons
Police Panic
Fire Panic
Medical Panic
– * and #
– 1 and *
– 3 and #
Status Press * if keypad shows NOT READY to view open zones
Arm Away 4-digit code + 2 (AWAY) to arm everything
Arm Stay 4-digit code + 3 (STAY) to arm everything but motions
Quick-Arm (If Enabled) # + 2 for AWAY, # + 3 for STAY
Instant Arm 4-digit code + 7 (INSTANT), also bypasses motions
Max Arming 4-digit code + 4 (MAX), arms everything including motions instant
Disarm 4-digit code + 1 (OFF)
Silence Alarm 4-digit code + 1 (OFF) twice to turn off siren and reset display
Bypass 4-digit code + 6 (BYPASS) + Zone (001, 002 003 etc)
(Keypad will beep and BYPASS + Zone will show on display)
Door Chimes 4-digit code + 9 (CHIME)
Reset Smoke 4-digit code + 1 (OFF) twice to turn off siren and reset smoke
(If this does NOT reset smoke detector set for service, smoke is bad)
Alarm Memory 1. Enter 4-digit code + # + 6 + 0, select 0 for Recent or 1 for Complete log
2. Select Partition (press 0 for all partitions)
3. Press 1 for previous log entries or 3 for next log entries
4. Press 8 to select catagory and 8 again for next entry
5. Press * to exit
Test Sensors 4-digit Code + 5 (TEST)
Keypad will beep every 3 minutes
Open sensors and keypad will sound
End test with 4-digit Code + 1 (OFF) key
(Wireless motions require no movement for 4 minutes prior to testing)
Setting Clock (some systems may not allow changing Clock)
1. Enter Master Code + # + 63, display will show current Time/Date
2. Enter correct (00 to 12) Hour then press *
3. Enter correct Minutes (00 to 59) then press *
4. Press any key from 0 to 9 to toggle AM and PM then press *
5. Enter correct Month (01 to 12) then press *
6. Enter correct Date (01 to 31) then press *
7. Enter correct Year (99 or 00 etc) then press *
2. Press * after cursor is in the Year setting to exit
Access Partition User Code + * and Partition (0, 1, 2 etc)
Go/NoGo test (Verify signal strength)
1. Installer code 5
2. Receiver gain is reduced by 50%
3. Keypad will beep 3 times to indicate signal reception
Display Zones Hold * for 5 seconds to view all zone descriptions
View Message Hold 0 for 5 seconds