Ademco Vista 21IP Sensors
Ademco 5816 Door / Window
![]() |
Ademco 5745 / 5845 Glassbreak
![]() |
Ademco 5849 Glassbreak
![]() |
Ademco 5850 (Intellisense) Glassbreak
![]() |
Ademco 5801 Keyfob / Panic
![]() |
Ademco 5804 Keyfob
![]() |
||
Zone Types | 21=Arm-Away | 22=Disarm |
20=Arm-Stay | 07=24 Hr Police | |
06= 24 Hr Silent Police |
Ademco 5827 Keypad
![]() |
Remove battery when changing switches! |
Note: older versions will work with 5700 wireless systems, new versions do not. |
House ID | Dip Switch | House ID | Dip Switch | ||||||||
1 | 2 | 3 | 4 | 5 | 1 | 2 | 3 | 4 | 5 | ||
1 | dn | dn | dn | dn | UP | 16 | UP | dn | dn | dn | dn |
2 | dn | dn | dn | UP | dn | 17 | UP | dn | dn | dn | UP |
3 | dn | dn | dn | UP | UP | 18 | UP | dn | dn | UP | dn |
4 | dn | dn | UP | dn | dn | 19 | UP | dn | dn | UP | UP |
5 | dn | dn | UP | dn | UP | 20 | UP | dn | UP | dn | dn |
6 | dn | dn | UP | UP | dn | 21 | UP | dn | UP | dn | UP |
7 | dn | dn | UP | UP | UP | 22 | UP | dn | UP | UP | dn |
8 | dn | UP | dn | dn | dn | 23 | UP | dn | UP | UP | UP |
9 | dn | UP | dn | dn | UP | 24 | UP | UP | dn | dn | dn |
10 | dn | UP | dn | UP | dn | 25 | UP | UP | dn | dn | UP |
11 | dn | UP | dn | UP | UP | 26 | UP | UP | dn | UP | dn |
12 | dn | UP | UP | dn | dn | 27 | UP | UP | dn | UP | UP |
13 | dn | UP | UP | dn | UP | 28 | UP | UP | UP | dn | dn |
14 | dn | UP | UP | UP | dn | 29 | UP | UP | UP | dn | UP |
15 | dn | UP | UP | UP | UP | 30 | UP | UP | UP | UP | dn |
31 | UP | UP | UP | UP | UP |
Ademco 5827BD Keypad
![]() |
Requires 5800TM Transmitter Module | |
If using 5128RF keypad the 5800TM module is not needed | |
If using 5881 or 5882 receiver the 5800TM is needed | |
Panel Programming |
1. Enter RF System type in *22 (1 = 5700 2= 5800) 2. Enter House Code in *24 (01 – 31) |
Keypad Programming |
1. Press * (Yellow light starts blinking) 2. Hold 1 and 3 for 3 seconds (Red & Green Lights start blinking) 3. * 8 + Master Code + # (Enters Master Code) 4. * 1 + Master Code + # (Enables Quick Arm) 5. * 9 + House Code + # 6. * 57 + # if using 5700 Receiver * 58 + # if 5800 7. * + # exits programming |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
|||||||||||||||||||||||||||||||||||||||||||||
Works ONLY with 5881EN Encrypted Receivers, will not work on older receivers or Lynx | |||||||||||||||||||||||||||||||||||||||||||||
Serial number on bottom sticker of watch, make sure tech writes it down in panel as a backup if lost | |||||||||||||||||||||||||||||||||||||||||||||
Operation Press Red SECURITY button then press function desired | |||||||||||||||||||||||||||||||||||||||||||||
Program | |||||||||||||||||||||||||||||||||||||||||||||
1. Hold Red SECURITY button for 8 seconds, Loop 1 programming begins | |||||||||||||||||||||||||||||||||||||||||||||
![]() (This shows Loop 1 is disabled) |
|||||||||||||||||||||||||||||||||||||||||||||
2. Press START/STOP to cycle through available commands (see list at bottom) | |||||||||||||||||||||||||||||||||||||||||||||
![]() (This shows Loop 1 is set for AWAY Arming) |
|||||||||||||||||||||||||||||||||||||||||||||
3. Press MODE to save selected command and move to next | |||||||||||||||||||||||||||||||||||||||||||||
4. Some commands support a delay from 0 to 15 seconds, cycle selections with | |||||||||||||||||||||||||||||||||||||||||||||
START/STOP then press MODE to save and move to Loop 2 | |||||||||||||||||||||||||||||||||||||||||||||
![]() (This shows Loop 1 is set for no sending delay) |
|||||||||||||||||||||||||||||||||||||||||||||
5. After programming all 4 loops display will show message duration, this is time in seconds signal will send, press START/STOP to cycle selections then MODE to save (bad areas may need longer time to send, good areas less) |
|||||||||||||||||||||||||||||||||||||||||||||
![]() (This shows send duration of 8 seconds) |
|||||||||||||||||||||||||||||||||||||||||||||
6. Press Red SECURITY button to exit programming | |||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||
*sorry don’t know what these commands do yet |
![]() |
![]() |
Available in Low (8 zones), Medium (16 zones) and High (up to 64 zones) |